Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.9 L+₹3.1 L (7.62%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹44.9 L+₹4.1 L (10.0%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹44.9 L+₹4.1 L (10.2%)Rejected-AOC | L4 | Rejected-AOC Not being L1 |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
29 Sept 2022, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
SPL REPAIR FOR REPLACEMENT OF UNSV WATER PIPELINE, BOREWELL AT FEL,B COY,2-IN-ONE, PROVN OF DGSET OF CAPACITY 100KVA AGAINST BER ALONGWITH HARDSTANDING AND OPENSHED AT CDA OFFICE COMPLEX AND PROVN OF 25KVA GEN AT NAVYHOUSE UNDER GE(U)SECBAD
2022_MES_549871_1
GE(U)/SEC/TOKEN/37 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
120 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹93,000
Yes
6 May 2023
3 Sept 2022
6 Oct 2022
3 Sept 2022
29 Sept 2022
17 Sept 2022
Amount
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out in hard/dense soil for removing/laying of pipe line complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Taking up or down steel tubing laid in trenches, on wall/in floor, in plinth protection of Bldg including segregation of serviceable pipes and keep in safe custody for reuse, complete with all fittings and connections of the following sizes:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Refixing of old steel tubing after cleaning and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia Notes for item No 5.01 to 5.05 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing after cleaning and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:- Note : Rate quoted by the contractor are deemed to be inclusive of all kind of fittings, bends, flange, thread cutting, scaffolding, , roof / wall drilling as required for crossing / passing of pipes etc as required for proper fixing of pipe
20 mm dia
25 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- Note : Rate quoted by the contractor are deemed to be inclusive of all kind of fittings, bends, flange, thread cutting etc as required for proper fixing of pipe
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia Notes for item No 7.01 to 7.05 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:- Note : Rate quoted by the contractor are deemed to be inclusive of all kind of fittings, bends, flange , thread cutting, scaffolding , roof / wall drilling as required for crossing / passing of pipes etc as required for proper fixing of pipe
20 mm dia
25 mm dia Notes for item No 8.01 to 8.02 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI / DI / GI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, GI fittings, Joints and Earth work shall be measured and paid separately under relevant items of this schedule.
50 mm Dia
80 mm Dia
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with brass ball valve , screwed both ends for GI pipes including making necessary arrangements and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore Make for item No 10.01 to 10.04 : Zoloto / RAMCO/Kartar
Construction of valve chamber of size 1200 x 1200 mm (Internal size) 900 mm deep with 200mm thick PCC block masonry walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys (Godrej/Shell), MS handles and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, for passing of GI Pipe of dia up to 80mm and other required materials in co-ordination with the concerned authorities complete all as specified and as directed. Note : GI Pipe will be measured and paid separately under relevant items.
M&L Cement Concrete 1:3:6 Type C2 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Use and Waste of Formwork (if required), complete all as specified and as directed.
M&L Cement Concrete 1:2:4 Type B2 (40mm Graded Stone Aggregate) as in Side Wall of Cable Duct, etc., complete all as specified and as directed.
Cutting the existing road straight by manual, depth not less than 0.75 meter and width as required for pipes up to 100 mm dia and refill the same with excavated soil up to 80 % road portion and 20 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
Cutting the existing building plinth protection by manual, depth and width as required for replacement of GI /any kind of pipes up to 50 mm dia and refill the same with excavated soil up to 80 % plinth portion and 20 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) and making good of all disturbed surface complete all as specified and directed.
Material and labour for deilling vertically from average ground level for 200 mm dia bore hole in any type of strata including HARD ROCK by mud flash rotary ring including cost of drilling shall be done by mud flash rotating equipment bore shall be unsealed at least for 48 hours to the entire depth of bore holes, depth of bore hole from 0 to 100 meters depth including sub soil complete and removal of drilled/board materials to a distance not exceeding 50 mtr, spreading leveling and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as directed. Note : Quoted rates inclusive of drilling initial 6 m of suitable dia for fixing of 150 mm dia column pipe
All as per item No 17 here-in-before but depth of bore hole exceeding 100 meter depth below ground level and upto 200 meter.
All as per item No 17 here-in-before but depth of bore hole exceeding 200 meter depth below ground level and upto 300 meter.
Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water.
Supply, install, Testing and Commissioning of Borewell Submersible Pumpset of 3.0 HP - 12 Stage V4 series , IP68 , Insulation Class " B" Power : 3.0 H.P. ( 2.20 K.W.), Voltage : 160-240 Volt Phase : Single Phase Head Range :30 to 120 Meter Flow rate : 92 to 53 L.P.M. Outlet : 38 mm Material : Housing & Shaft -Stainless Steel , Impeller : Noryl, NRV/Suction : Cast Iron Bore size: 100mm and above Bore Dia Winding : Copper Motor type : water filled Note: Quoted rates inclusive of reducers/ sockets, nutbolts, nipple etc as required for fixing of pumps with GI/HDPE Column pipes Make Kirloskar Model KS4E-3012 (1PH) or equivalent from CG / CRI/KSB as approved by GE.
Supply , install , Testing and Commissioning of Borewell Submersible Pumpset of 5.0 HP - 20 Stage, IP68, Insulation Class " B" Power : 5.0 H.P. ( 3.75 K.W.), Voltage : 160-240 Volt Phase : Single Phase Head Range :30 to 120 Meter Flow rate : 154 to 88 L.P.M. Outlet : 38 mm Material : Housing & Shaft -Stainless Steel , Impeller : Noryl, NRV/Suction : Cast Iron Bore size: 100mm and above Bore Dia Winding : Copper Motor type : water filled Note: Quoted rates are deemed to be inclusive of reducers/ sockets, nutbolts, nipple etc as required for fixing of pumps with GI/HDPE Column pipes Make : Kirloskar Model KS4E-5020 (1PH) or equivalent from CG / CRI/KSB as approved by GE.
Supply, installation, Testing and commissioning of CPRI approved pump starter electric control panel board POWDER COATED, for out door use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.00 mm thick angle iron legs of size 50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for single phase, 240 Volts, 50 C/S 2 wire system, with cable entry provision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly powder coated complete all as including necessary PCC work of height 500 cm from the ground level complete all as specified and directed of the following (Leg of the panel should not be less than 0.75 M and size of the panel should not be less than (70CmX70CMX30CM)) :-
Supply, installation, Testing and commissioning of CPRI approved pump starter electric control panel board POWDER COATED, for out door use, DOUBLE door (BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.00 mm thick angle iron legs of size 50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for single phase, 240 Volts, 50 C/S 2 wire system, with cable entry provision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly powder coated complete all as including necessary PCC work of height 500 cm from the ground level complete all as specified and directed of the following (Leg of the panel should not be less than 0.75 M and size of the panel should not be less than (70CmX70CMX30CM)) :-
Supply , installation, Testing and commissioning of CPRI approved pump starter electric control panel board POWDER COATED, for outdoor use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.00 mm thick angle iron legs of size 50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for three phase, 240 Volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly powder coated complete all as including necessary PCC work of height 500 cm from the ground level complete all as specified and directed of the following (Leg of the panel should not be less than 0.75 M and size of the panel should not be less than( 80CmX70CMX30CM)) :-
Supply and laying water proof submersible flat cable PVC sheathed multistranded copper conductor 3 core 4 sqmm 1100 volts grade laid between submersible pump and control panel
Supply & Fixing PVC pipe 6 kg/cm2 of size 180 mm dia heavy duty screwed and socketed type to borewell confirming to IS complete all as specified and directed. Make : Sudhakar or equivalent as approved by GE
Supply & Fixing PVC pipe 6 kg/cm2 of size 250 mm dia heavy duty screwed and socketed type to borewell confirming to IS complete all as specified and directed. Make : Sudhakar or equivalent as approved by GE
Supply & lowering HDPE heavy duty coloumn pipe in bore well af ter fixing with submersible pup sets of internal dia 40mm PN 16kq/Sqmm including necessary fixing arrangement with submersible motor, and necessary clamp for supporting at the top portion of bore well complete all as d specified and directed. Make : Sudhakar or equivalent as approved by GE. Note: Quoted rates are deemed to be inclusive of lowering of pipe in bore well, necessary connection with MOTOR by using GI fittings, clamps, nut bolts etc as required of heavy duty, 2 sets of clamps for supporting of pipes at the TOP and including provision of fixing of NRV
Supply and installing column pipe heavy duty GI 50 mm dia 3 m long including long heavy duty sockets complete all as specified and directed. Note: One length of 3 m pipe and socket to be considered as one unit . Quoted rates are deemed to be inclusive of lowering the pipes in the bore wells including necessary arrangements
Yield test for the bore well by continuously pumping for 016 hours to determine safe pumping yield.
Testing of water for portability both bacteriological and chemical analysis from approved Govt laboratory complete all as directed
S&F gun metal non return valve 50 mm dia, complete all including making necessary arrangement
Supply, Install, Testing and Commissioning of Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg Backfill compound to provide maximum contact between the electrode and Back Fill Compound. The earthing pit cover should be factory built (size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed
S&F galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete all as specified and as directed.
S&F submersible pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 6 HP motor relay range 9-14 Amps complete all including necessary connections complete all as directed. Make L&T model number ss97756 or equivalent from SIEMENS/ABB/SCHNEIDER as approved by GE.
S&F submersible pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 10 HP motor relay range 13-21 Amps complete all including necessary connections complete all as directed. Make L&T model number ss95983 or equivalent from SIEMENS/ABB/SCHNEIDER as approved by GE.
M&L for flushing of existing borewells of any size upto 150 Mtrs depth with drilling compressor mounted on truck including surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of water samples for chemical and bacteriological tests and complete all as specified and directed .
M&L for removing submersible pump motor set of capacity up to 7.5 HP stuck inside the borewell of depth up to 100 meter by flushing the existing borewells of any size with drilling compressor mounted on truck at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till removing of the stuck motor and then clear the bore by using Rod drilling using Bore well drilling machine from any kind of obstruction, reinstall the motor and coloumn pipe , necessary electric connection and testing complete all as specified and directed . Note : Rate quoted by the contractor is deemed to be inclusive of Flushing by using suitable compressor, rod drilling for clearing of bore well, Removing the submersible pump set stuck inside the bore well and reinstall the same after repair including removing and refixing of coloumn pipe, electrical connections, testing etc as required.
Supply, transportation and safe delivery to Site, unloading, safe storage, installation, testing and commissioning of silent Diesel engine driven Generating Set, AC, 415 Volt, 3 Phase 4 wire 50 Hz, 1500 RPM of capacity 100 KVA, Engine as per IS : 10001/10002 and Alternator as per IS : 13364 with Accoustic enclosure, AMF Panel comprising of the following and testing complete all as specified and as directed by Engineer-in-Charge Make: Kirsloskar Green Model No KG1-100 WS or equivalent model of caterpillar /Cummins as approved by GE. (a) DIESEL ENGINE : Four cylinder, Liquid cooled, Naturally aspirated and developing 156 BHP @ 1500 RPM, vertical engine, electric start, compression ignition, 4 stroke designed to run continuously @ 1500 RPM confirming to IS 10002, ISO 3046, BS : 5514 standards with an overload capacity of 10 % for one hour in every 12 hrs operation, DG set to comply with CPCB-II norms and shall comprise the following accessories Make : Kirloskar Green, Engine Model No. 4K1080TA G2 or its equivalent model viz. equivalent technical specifications in other makes as specified here in above as approved by GE):-
(a) Radiator cooling system with fan (b) Micro fuel pump with electronic governor (c) Dry tube Air cleaner (d) Lubricating Oil filter (Spin on type) (e) 12 Volts Electric Starting system (f) Battery Charging Alternator (g) Stop solenoid (h) Lub Oil Pressure Gauge (j) Water Temperature Gauge (k) Ammeter Battery Charging (l) K Cool Super Plus Coolant (m) First Fill of Lub Oil (n) Safety Shut Down system for Low Lube Oil (o) Air valve and drain plug arrangement
(B) ALTERNATOR Alternator suitable for continuous operation rated at 1500 RPM, 415 Volts, 3 Phase, 4 wire system, 50 Hz, 0.8 PF in SPDP enclosure, self excited and self regulated, brushless, foot mounted in single/ double bearing construction on end shields conforming to IS 4722, BS EN 60034-1 and will be suitable for tropical condition. Make of Alternator : STAMFORD / CATERPILLAR / LEROY SOMER /KIRLOSKAR ELECTRIC / KIRLOSKER GREEN/CUMMINS (C) ACOUSTIC ENCLOSURE: The acoustic enclosure shall be designed and manufactured confirming to relevant standards suitable for outdoor installation exposed to weather conditions, and to limit noise level of <75 db (A) at a distance of 1 metre from the enclosure as per CRCB II norms. The enclosure shall be fabricated out of FRCA sheet of thickness not less than 2.0 mm thick and shall be powder coated. (D) CONTROL PANEL : CONTROL PANEL ALONG WITH SUITABLE CONTROLLER AND MCCB4 pOLE 25 ka ADJUSTABLE TYPE TO BE PROVIDED INSIDE CANOPY (E) AMF CONTROL PANEL SUITABLE FOR OUTDOOR INSTALLATION WITH BY PASS ARRANGEMENT : Supply, Installation, Testing and commissioning of AMF (Automatic Mains Failure) panel suitable for generating set of capacity 100 KVA factory made, fabricated out of CRCA sheet (3.00 mm thick) of min size 1.675 M X 1.300 M X0.50 M, totally enclosed, dust , damp and vermin proof free standing floor mounted type and front operated, degree of protection required will be IP-55 conforming to IS 2147 with and including necessary foundation (Minimum height of the base of the panel board should not be less than 0.45 Meter) having the following features / facilities:-
Supply, lay and connecting by using lugs of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty, 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core, complete all as specified and directed. Make : KEI/Polycab/Havells/Gloster
Supply , lay and connecting by using lugs of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty, 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5core, complete all as specified and directed. Make : KEI/Polycab/Havells/Gloster
Supplying and laying unreinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all as specified and directed by Engr-in-Charge.
Spreading riddled earth ( after preparation of excavated earth) in Cable duct for cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge Note:- Punned thickness 18 CM( 6.25 CM below cable and 11.75 cm above cable) will be measured for payment purpose. The earth removed during excavation to be used as riddled earth after crushing and sieving. Quoted rate inclusive of all arrangement as mentioned.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Excavation in post holes (or similar holes ) each nexc 0.5 cum getting out returning filling in hard/ dense soil.
M&L PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified and directed.
Material and labour for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation / bed concrete.
M&L Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar 1:6 complete
M&L for 100 mm thick cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in sub base or sub floors finishing the surfaces even and rough to receive the topping layer complete all as specified and directed.
M&L for 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) finishing the surfaces even complete all as specified and directed.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces
M&L Three coats of white wash including preparing new surfaces plastered or unplastered
S&F steel work in tubular trusses / poles (unframed) including purlins, rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and directed.
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including ridge complete all as specified and directed.
M&L Two coats of synthetic enamel paint on steel surfaces of any description, over 10cm in width or girth, over a coat of primer including preparation of new surfaces all as specified
Supply, install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wire engine as per IS : 10001/10002 conforming to CPCB Norms II, and alternator as per IS : 13364 of capacity 25 KVA/ 20 KW at site complete with control panel having meters, sound proof canopy etc including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure :- AC Generator should be suitable for ambient conditions at Secunderabad and confirming to IS. Make : Engine : CUMMINS/CATERPILLAR/KIRLOSKAR GREEN Alternator : STAMFORD / CATERPILLAR / LEROY SOMER / KIRLOSKAR GREEN / CROMPTON GREAVES Battery : EXIDE / AMAR RAJA / AMCO or as per manufacturer specification.
(Note :- The capacity of generator set shall be net after all de-rating factor as per relevant IS design) (a) Alternator :- Standard design alternator rated at (20 KW) net output at site after considering all de-rating factors, site conditions and at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 %.
(b) Diesel Engine :- Vertical diesel engine of suitable capacity, water cooled, closed circuit as per BS-649 or IS-1002 direct injuction type . Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running 24 hrs continuously with 10% over loading for 01 hour in every 12 hours as per BS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection and equipped with all standard fitting as per manufacture's recommendations and mounted on common base frame with following Specifications :-
(i) Fly wheel with housing :- Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturer's instructions "(ii) Cooling system :- (a) Mounted radiator with fan & belts & guard, rubber hoses and thermostat. (b) Cooling water pump centrifugal type . " (iii) Governer :- Electronic Governer. (iv) Electric Starting System :- Electric Self starter, 12 volts DC (12 volt, 100 AH battery 1 No's) charging alternator as per manufacturer's design, copper leads with lugs of adequate size complete with initial charging of maintenance free battery 1x12 volt 100 AH capacity. Make :- Exide or as per manufacturer's specification as approved by GE.
(v) Generator Monitoring Panel :- Comprising of following :- (a) Microprocessor based genset controller for metering, monitoring, governing and protection (b) Engine protection for low lub oil pressure, high coolant temperature (Alarm & Shutdown) (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency (Alarm & Shut down) (vi) Accessories :- AVM Pads built or separately mounted to manufacturer base frames. (vii) Coupling Arrangements :- Fixed coupling, flywheel to suit fixed coupling and fly wheel housing. (viii) Exhaust System :- Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbetos rope of suitable size all as directed. (ix) Fuel Tank :- Daily service fuel tank of capacity suitable for 12 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturer's design.
(e) Civil Works:- All civil works related to foundation, installation of panel and equipment and depth of foundation shall be minimum 300mm with antivibration pads, or as recommended by the manufacturers. Cables from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:- (i) The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department. (ii) The testing of Genset for continuous 12 Hours shall be done by an officer detailed by accepting officer after installation at site No load - 1/2 Hour 25% load - 1/2 Hour 50% load - 1 Hour 75% load - 1 Hour 100% load - 8 Hours 110% load - 1 Hour
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
POWER CONSTRUCTION COMPANY
L and S ENTERPRISES
sree venkateswara enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .