Tender Value
₹10.6 L
EMD Value
₹21,175
Closing Date
1 Sept 2026, 5:00 pm6d left
Amit Rathi
DIV Rewari
Annual Maintenance Estimate of Master Water Supply Scheme in U/E Narnaul .
2026_HBC_543390_1
2026261EAEB2 A144 49C8 B8A5 320C66D77832258HSV
Open Tender
Civil Works
Works
60 days
Narnaul
2 documents required · 2 mandatory
₹590
₹21,175
Yes
25 Aug 2026
25 Aug 2026
2 Sept 2026
25 Aug 2026
1 Sept 2026
25 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [1.LB007] LB007. Chowkidar | 120 | Per day | 838 | ₹1,00,560 |
| 2 | [1.LB008] LB008. Beldar | 120 | Per day | 838 | ₹1,00,560 |
| 3 | [1.LB042] LB042. Pump Operators | 180 | Per day | 838 | ₹1,50,840 |
| 4 | [1.LB044] LB044. Electrician | 60 | Per day | 838 | ₹50,280 |
| 5 | [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) | 150.4 | Sqm | 113 | ₹16,995.2 |
| 6 | [14.51.2]Hire charges for Hydraulic excavator/Loader like JCB/Pock lain, Hitachi etc with all accessories having bucket capacity 2. Hire Charges for excavator 0.40 to 0.75 cum bucket capacity | 12 | Per day | 7,421 | ₹89,052 |
| 7 | [20.11.3]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 3. 150 mm i/d | 2 | Each | 5,746 | ₹11,492 |
| 8 | [20.114.3]Supplying erection, testing of fully
automatic electric control panel board for
T/Wells in Pump Chamber consisting of
MS sheet of thickness 14 gauge duly
painted box type floor mounted made of
angle Frame containing 1 no. fully
automatic air brake starter suitable for
Motor of the following capacity, Min
switch of suitable range with HRC fuse, 1
no. volt meter (0 to 500 volts), 1 No.
Amp. Meter of 0 to 100 amp. 3 sets of
indicating lamp capacitor of suitable
capacity and 1 no. single phase preventers
with the timer switch including wiring in
panel board and suitable electric energy
meter wiring in Electric Control Panel
Board complete in all respect as per
specification given in Schedule No. II,
Including MCB, suitable, Capacitor,
Wooden Box etc as per site
requirement complete in all respect. 3. 20 HP Motor | 2 | Each | 23,190 | ₹46,380 |
| 9 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm) | 2 | Each | 2,054 | ₹4,108 |
| 10 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA | 2 | Each | 10,809 | ₹21,618 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
BOQ_622904.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].