Tender Value
₹1.8 L
EMD Value
₹3,700
Closing Date
2 Jun 2026, 1:00 pmClosed
Executive Engineer (Elect)-I
OFFICE OF THE Ex. ENGINEER (ELECT)-I, SHAHDARA (N) ZONE, KeshavChowk, Delhi-110053
AMC of Tubewells installed in various Permanent Pumping stations under EEE-I Shahdara ( North ) Zone.
2026_MCD_278801_1
EE(E)-I/Sh.N/MCD/26-27/TC-10/3
Open Tender
Electrical Works
Percentage
365 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹3,700
18 Jun 2026
26 May 2026
2 Jun 2026
26 May 2026
2 Jun 2026
26 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of following size of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS :694/210 etc. rqd. 3x2.5 sq.mm with voltage grade 1100 volts. | 160 | Meter | 98 | ₹15,680 |
| 2 | Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd. | 3 | Each | 8,256 | ₹24,768 |
| 3 | Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells installed at various Municipal Parks Cost for one Tube wells with submersible pump set etc of rating upto 1/1.5 HP for one year | 4 | Each | 9,989 | ₹39,956 |
| 4 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.(a)40 Amp. | 3 | Each | 472 | ₹1,416 |
| 5 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. | 4 | Set | 5,958 | ₹23,832 |
| 6 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | 20 | Meter | 313 | ₹6,260 |
| 7 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as
required. | 30 | Each | 50 | ₹1,500 |
| 8 | Supply lowering and fixing following size of G.I Pipe (M-Class) i/c cutting threading on both side etc. ISI marked etc as reqd. 32 mm (Nominal Bore). | 40 | Meter | 324 | ₹12,960 |
| 9 | Supplying and fixing following size of G.I. Socket as reqd. 32 mm dia | 10 | Each | 165 | ₹1,650 |
| 10 | Supplying and fixing following size of G.I. Union as reqd. 32 mm dia | 3 | Each | 377 | ₹1,131 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
GCC2024.pdf
Tender Documents • 9.36 MB
Conditions_Tubewells.pdf
Tender Documents • 0.20 MB
Circular_1.pdf
Tender Documents • 2.39 MB
BOQ_325489.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .