Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.8 LAccepted-AOC | ₹76.8 L | L1 | Accepted-AOC OK |
| 2 | L2₹77.0 LRejected-AOC | ₹77.0 L | L2 | Rejected-AOC OK |
| 3 | L3₹77.8 LRejected-AOC N A | ₹77.8 L | L3 | Rejected-AOC OK |
| 4 | L4₹79.1 LRejected-AOC JHARKHAND | ₹79.1 L | L4 | Rejected-AOC OK |
| 5 | L5₹81.1 LRejected-AOC AT KANDSAR P O BAHIMAR P S KATKAMSANDI DIST HAZARIBAG JHARKHAND | NA | NA | 835201 | ₹81.1 L | L5 | Rejected-AOC OK |
Tender Value
₹96.0 L
EMD Value
₹1.9 L
Closing Date
16 Feb 2026, 5:00 pmClosed
EE RDSD HZB
EE RDSD HZB
Construction of PCC Road Drain Culvert and Guard Wall From Arahara TP 5 Tawar chowk house of Tuleshwar Mahto to house of Dineshwar Mahto via Hiraman Mahto Under Block Barkagaon
2026_RDSPL_110197_1
RDSPL/SD/HZB/37/2025-26
Open Tender
Civil Works
181 days
Barkagaon hazaribagh
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.9 L
11 May 2026
10 Feb 2026
17 Feb 2026
10 Feb 2026
16 Feb 2026
10 Feb 2026
Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 1.5mm cement punning including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. S.O.R. Item No.(5.7.2+5.7.11) (B.C.D.)
Providing Tuck Pointing in cement on stone masonary (1:3) cement on brick work with clean coarse sand of F.M. 1.5 including S.O.R. Item No.5.7.10 (B.C.D.)
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. S.O.R. Item No.5.6.3 (B.C.D.)
Clearing of grass and removal of rubbish up to a distance of 50 m outside the periphery of the area as per Technical Specification Clause 201 S.O.R. Item No. (2.02)
Excavation for roadwork in Ordinary Rock with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m SOR No RDD 3.07
Construction of Subgrade and Earthen Shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300.2 with 1000M lead as per Technical Specification Clause 303.1 SOR No RDD 3.18
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tablea 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.41 SOR No RDD 3.20 Case-I
Granular sub-base with Close Graded Material (Table:400-1) Plant Mix Method (Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401) SOR No RDD 4.01 B (iii)
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with approve grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing SOR No RDD 6.02
Direction and Place Identification Signs with size more than 0.9 sqm size Board.(Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area exceeding 0.9 sqm fixed over back support frame of min 40 x 40 x 5 mm Angle mounted on two nos. of mild steel circular pipe 65 NB, 3.2mm thickness and 4.5m meter total height firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) SOR No RDD 8.06
Sand Filling in foundation trenches as per drawing & technical specification S.O.R. Item No.12.03 (RDD)
Stone masonry work in cement mortar 1:3 in foundation complete as per drawing and technical specifications. Random Rubble masonry (coursed/uncoursed) SOR No RDD 12.07
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. Grade-M15 S.O.R. Item No.12.08 A Case-I (RDD)
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. Grade-M15 S.O.R. Item No.12.08 A Case-ii (RDD)
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. RCC Grade M20 using batching plant, transit mixer & manual placing S.O.R. Item No. 12.08 C case-ii
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specifications Random Rubble Masonry (Coursed/uncoursed) SOR No.13.04 (RDD)
Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications PCC Grade M15 using batching plant & concrete pump SOR No.13.05 AP (RDD)
Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications PCC Grade M-20 using batching plant & concrete pump SOR No.13.05 B(P) (RDD))
Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications SOR No.13.06 (RDD)
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment , wing wall/ returen wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications. SOR No.13.08 (RDD)
Back filling behind abutment, wing wall, return wall complete as per drawing and technical specifications Granular Material SOR No.13.09 A (RDD)
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification RCC Grade M25 Using Batching Plant, Transit Mixer and Concrete Pump Height upto 5M SOR No.14.01 B Case-i (RDD)
Providing and laying cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. SOR No.14.02 (RDD)
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 all complete job.SOR No.16.09 (RDD)
Cement (Lead 35 KM)
Sand (Lead 08 KM)
Stone chips (Lead 28 KM)
Stone Dust (Lead 28 KM)
Boulder (Lead 28 KM)
Bricks (Lead 08 KM)
Steel (Lead 35 KM)
Goods & Services Tax (G.S.T.) - 18%
Labour Cess - 1%
Please Enable Macros to View BoQ information
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
Tender_Documents.pdf
Tender Documents • 1.07 MB
BOQ_148985.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid