Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹32.4 L+₹2.6 L (8.80%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹37.4 L+₹7.6 L (25.6%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹45.9 L+₹16.1 L (54.1%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L4 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | national engineering L3 | M/S TRADE LINK L4 | M/S NANCY ENTERPRISES L1 | EESSI L2 |
|---|---|---|---|---|---|---|---|
| 1.00M & L for Pre - insulated MS pipe, Class 'C' having minimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge GI/AL cladding complete suitable for above ground as per sizes shown including taking down the old pipes. The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of -50 Degree Celcius to 120 Degree Celcius. Note :- The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589 having minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia and minimum 7mm thick MS sheet for pipes of 400 mm dia and above. | |||||||
| 1.01 | 150 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding. | 200 | RM | 3,600 ₹7,20,000 | 5,000 ₹10,00,000 | 2,000 ₹4,00,000 Lowest | 2,300 ₹4,60,000 |
| 1.02 | 125 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding. | 200 | RM | 3,100 ₹6,20,000 | 4,500 ₹9,00,000 | 1,900 ₹3,80,000 Lowest | 2,060 ₹4,12,000 |
| 1.03 | 100 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding. | 230 | RM | 2,600 ₹5,98,000 | 3,300 ₹7,59,000 | 1,800 ₹4,14,000 Lowest | 2,000 ₹4,60,000 |
| 1.04 | 80 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding. | 300 | RM | 2,100 ₹6,30,000 | 2,550 ₹7,65,000 | 1,700 ₹5,10,000 Lowest | 1,800 ₹5,40,000 |
| 1.05 | 50 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding. | 150 | RM | 1,600 ₹2,40,000 | 2,000 ₹3,00,000 | 1,600 ₹2,40,000 | 1,200 ₹1,80,000 Lowest |
| 2.00Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings (elbows, tees, reducers, sockets, u trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system complete including taking down the old pipes for nominal diameters of pipe as indicated below: | |||||||
| 2.01 | 25 mm dia pipe with Insulation thickness 19 mm | 220 | RM | 350 ₹77,000 Lowest | 500 ₹1,10,000 | 1,200 ₹2,64,000 | 500 ₹1,10,000 |
| 2.02 | 32 mm dia pipe with Insulation thickness 19 mm | 200 | RM | 450 ₹90,000 Lowest | 600 ₹1,20,000 | 1,000 ₹2,00,000 | 560 ₹1,12,000 |
| 2.03 | 40 mm dia pipe with Insulation thickness 19 mm | 160 | RM | 525 ₹84,000 Lowest | 700 ₹1,12,000 | 900 ₹1,44,000 | 600 ₹96,000 |
Tender Value
₹44.6 L
EMD Value
₹89,260
Closing Date
11 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 138 WE
CWE, HQ 138 WE
SPECIAL REPAIR TO CENTRAL HEATING SYSTEM AT CESR UNDER GE 865 EWS
2025_MES_714174_1
138WE/L-79/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per tender documents
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹89,260
Yes
7 Aug 2025
13 Jun 2025
18 Jul 2025
13 Jun 2025
11 Jul 2025
27 Jun 2025
Amount
M & L for Pre - insulated MS pipe, Class 'C' having minimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge GI/AL cladding complete suitable for above ground as per sizes shown including taking down the old pipes. The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of -50 Degree Celcius to 120 Degree Celcius. Note :- The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589 having minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia and minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
150 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding.
125 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding.
100 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding.
80 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding.
50 mm with 50 mm dia PUF thicknes and 24 gauge Al cladding.
Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings (elbows, tees, reducers, sockets, u trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system complete including taking down the old pipes for nominal diameters of pipe as indicated below:
25 mm dia pipe with Insulation thickness 19 mm
32 mm dia pipe with Insulation thickness 19 mm
40 mm dia pipe with Insulation thickness 19 mm
Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (PN-16 rating), strainers, gauges etc for condensor water circulation as per specifications including taking down existing valves. Insulation thickness of valves should be equal to the Insulation of PUF and GI cladding of pipe section as specified. Butterfly Valve (Insulated Valves) with CI body SS disc nitrile sheet & O ring, complete with fittings, nuts, bolts & gaskets.
150 mm dia Butterfly Valve
125 mm dia Butterfly Valve
100 mm dia Butterfly Valve
80 mm dia Butterfly Valve
40 mm dia Butterfly Valve
20 mm dia Butterfly Valve
Supply and fixing and replacement of chilled/hot water fan coil unit (FCU) vertical type floor mounting 2.5 TR capacity complete all as specfied and directed by Engr-in-Charge. Make: Carrier / Voltas / Blue Star or equivalent approved make as approved by GE
Supply and fixing and replacement of chilled/hot water fan coil unit (FCU) wall mounting 2.0 TR capacity complete all as specfied and directed by Engr-in-Charge. Make: Carrier / Voltas / Blue Star or equivalent approved make as approved by GE
Supply and fix in replacement of Inlet/outlet forged brass ball valve 20 mm with Y stainer for FCU, hot water for 25 to 90 degree temperature as per existing, including MS / GI nipple of size 3/4 inch, necessary welding work and cutting the existing rusty unserviceable MS/GI nipple complete all as specified and/ or as directed by Engr-in-Charge.
Supply and fix in replacement of Inlet/outlet forged brass ball valve 15 mm with Y stainer for FCU, hot water for 25 to 90 degree temperature as per existing, including MS / GI nipple of size 3/4 inch, necessary welding work and cutting the existing rusty unserviceable MS/GI nipple complete all as specified and/ or as directed by Engr-in-Charge.
EESSI (BID ID -3347230)
national engineering (BID ID -3347152)
M/S TRADE LINK (BID ID -3346185)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .