APO C3
MRPU, DAE, SHASTRI BHAVAN, NUNGAMBAKKAM, CHENNAI 600 006
LABORATORY INDICATORS, CONTROLLERS,CALIBRATORS AND PUMPS AS PER TECHNICAL SPECIFICATIONS
2022_DPS_723505_1
DPS/MRPU/4/3/7377
Open Tender
Electronic Components And Devices
Supply
210 days
SO, DPS STORES IGCAR, KALPAKKAM, CHENGALPETTU DIST
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1.7 L
Yes
16 Dec 2022
16 Nov 2022
16 Dec 2022
16 Nov 2022
15 Dec 2022
16 Nov 2022
Laboratory Digital Low Pressure Controller and indicator _range1 with accessories. 1. Instrument pressure range - Required range : 0 to 25 mbar (Gauge pressure) (Upper Range from 25 mbar to maximum of 75 mbar acceptable) 2. Performance parameters 2.1 Note: Performance evaluation of offered pressure controller will be based only on following calibration range as per 2.1.1 & calibration span as per 2.1.2 as mentioned below. 2.1.1 Calibration range: 0 to 25 mbar 2.1.2 Calibration Span: 25 mbar. 2.3 Precision: Shall be within 0.06% reading + 0.06 % Calibration Span including combined effect of linearity, repeatability, hysteresis and temperature effects throughout the operating temperature range. i.e. Calibration span = 25 mbar as per the specification annexure.
Laboratory Digital Low Pressure Controller and indicator _range2 with accessories. 1. Instrument pressure range: Required range : 0 to 700 mbar (Gauge pressure) (Upper Range from 700 mbar to maximum of 2.0 bar acceptable) 2. Performance parameters 2.1 Note: Performance evaluation of offered pressure controller will be based only on following calibration range as per 2.1.1 & calibration span as per 2.1.2 as mentioned below. 2.1.1 Calibration range: 0 to 700 mbar 2.1.2 Calibration Span: 700 mbar. 2.2. Precision: Shall be within 0.01 % of Calibration Span including combined effect of linearity, repeatability, hysteresis and temperature effects throughout the operating temperature range. i.e. Calibration span = 700 mbar as per the specification annexure.
Laboratory Digital Pressure Indicator with accessories. 1. Type of Indicator: Pressure indicator with different type of ranges and pressure modules for calibration lab. 2. Application: For Calibration laboratory 3. No. of Sensors: 4 nos. (Minimum two nos. pressure modules shall be only in-built and for balance two nos. may be external type but they should supply with necessary hardware and software etc. 4. Instrument pressure ranges: Sensor 1 Range: 0 to 25 mbar (Upper Range from 25 mbar to maximum of 75 mbar acceptable) Sensor 2 Range: 0 to 350 mbar (Upper Range from 350 mbar to maximum of 450 mbar acceptable) Sensor 3 Range: 0 to 700 mbar (Upper Range from 700 mbar to maximum of 2 bar acceptable) Sensor 4 Range: 0 to 7 bar (Upper Range from 7 bar to maximum of 20 bar acceptable) as per the specification annexure.
Digital pressure manometer cum loop calibrator_range1 with accessories. 1. Type: Compound pressure 2. Pressure sensing element: Sensor shall be Piezoresistive, capacitance, silicon resonant,etc Sensor with Temperature compensation. And sensor module shall be inbuilt/external type. 3. Range: +/- 25 mbar (Max range up to +/- 75 mbar acceptable) 4. Calibration range: +/-25 mbar 5. Precision: Shall be within ±0.06 % of FS* (see note-1) or better (including combined effect of repeatability, hysteresis) at temp compensation range. as per the specification annexure.
Digital pressure manometer cum loop calibrator_range2 with accessories. 1. Type: Compound pressure 2. Pressure sensing element: Sensor shall be piezoresistive, capacitance, silicon resonant,etc Sensor with Temperature compensation. And sensor module shall be inbuilt/external type. 3. Range: +/- 350 mbar (Max range up to +/- 750 mbar acceptable) 4. Calibration range: +/-350 mbar 5. Precision: Shall be within ± 0.05 % of FS* (see note-1) or better (including combined effect of repeatability, hysteresis) at temp compensation range. as per the specification annexure.
Digital pressure manometer cum loop calibrator_range3 with accessories. 1. Type: Compound pressure 2. Pressure sensing element: Sensor shall be Piezoresistive, capacitance, silicon resonant, etc Sensor with Temperature compensation. And sensor module shall be inbuilt/external type. 3. Range: -0.7 to + 6.0 bar(Max range up to -1 to 10 bar acceptable) 4. Calibration range: -0.7 to + 6.0 bar 5. Precision: Shall be within ±0.035 % of FS* (see note-1) or better (including combined effect of repeatability, hysteresis) at temp compensation range. as per the specification annexure.
Vacuum generation pump with accessories. • Vacuum generation range : 0 to -0.8 bar (Max pump range -1.0 bar to +4.0 bar is acceptable) • Type: hand operated • Pressure Media: Air • Material of Construction : Aluminum / SS • Pressure adjustment: Course as well as fine adjustment shall be provided. as per the specification annexure
High pressure generation pump with accessories. • Pressure generation range: 0 to +20 bar (Max pump range up to -1 to +35 bar is acceptable) • Type: hand operated • Pressure Media: Air • Material of Construction : Aluminum/ SS • Pressure adjustment: Course as well as fine adjustment shall be provided with separate knob/hand wheel. as per the specification annexure.
VALVE VISION
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .