| 1 | L1₹68.7 LAccepted-AOC B 4 47 BUDHYAPARK BBD PALLY P O P S KALYANI DIST NADIA PIN 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L1 | Accepted-AOC L1 | |
| 2 | L2₹68.7 L+₹2,612 (0.04%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹69.0 L+₹27,166 (0.40%)Rejected-AOC NISCHINTAPUR BUDGE BUDGE SOUTH 24 PARGANAS | L3 | Rejected-AOC L3 | |
| 4 | L4₹69.0 L+₹29,609.60 (0.43%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
7 Apr 2022, 12:00 pmClosed
Executive Engineer (AM), Malda-II (AM) Division
Executive Engineer (AM), Malda-II (AM) Division, Madhabnagar, Mokdampur, Malda, Administrative Building (1st Floor), Mokdampur-732103, Malda.
LAYING OF WTA, CONSTRUCTION OF PUMP HOUSE, INTERNAL WIRING OF PH AND SUPPLY OF MATERIALS ON TURNKEY BASIS AT RADHANAGAR CHIKNI MAJOR RLI SCHEME UNDER RATUA (A-M) SUB-DIVISION WITHIN MALDA -II (A-M) DIVISION UNDER CORE SECTOR 21-22 PROGRAMME.
2022_WRDD_369714_1
WRDD/EEAM /MLD-II /NIT -83e/21-22
Open Tender
CIVIL AND ELECTRICAL WORKS
Item Rate
90 days
Ratua
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.4 L
3 Jun 2022
14 Mar 2022
11 Apr 2022
15 Mar 2022
7 Apr 2022
15 Mar 2022
Amount
A. PROCUREMENT OF MATERIALS a. UPVC and P.V.C. PIPES & ACCESSORIES
315 mm. dia P.V.C. pipe Class- I ( with a loose matching coupler) marking IS No. 4985/ 1988 with latest amendments with free solvent cement.
200 mm. dia P.V.C. pipe Class- I ( with a loose matching coupler) marking IS No. 4985/ 1988 with latest amendments with free solvent cement.
140 mm. dia P.V.C. pipe Class- I ( with matching coupler ) marking IS No. 4985/1988 with latest amendments with free solvent cement.
140 mm. dia P.V.C. pipe class-II ( with a loose matching coupler) marking IS No. 4985/ 1988 with latest amending with free solvent cement.
200X200X200 mm dia P.V.C. Equal Tee I.S.I. with free solvent cement.
140X140X140 mm dia P.V.C. Equal Tee I.S.I. with free solvent cement.
315 mm.. dia ( IS. No. 10124/ 88 Part- 8 with latest amendment) F.T.P.
200 mm.. dia ( IS. No. 10124/ 88 Part- 6 with latest amendment) F.T.P.
140 mm. dia ( IS. No 10124/88 Part- 6 with latest amendment) F.T.P..
200 X 140 mm dia.P.V.C. Reducer (Class-II) with free solvent cement.
160 X 140 mm dia.P.V.C. Reducer (Class-II) with free solvent cement.
200 mm. dia 60 degree ( IS. No. 10124/88 Part- 8 with latest amendment ) bend
140 mm. dia 90 degree (IS. No. 10124/ 88 Part- 8 with latest amendment) bend
140 mm. dia 60 degree ( IS No. 10124/ 88 Part- 8 with latest amendment ) bend
200 mm. dia IS. NO. 10124/ 88 Part- 4 with latest amendment End cap.
140 mm. dia IS. NO. 10124/ 88 Part- 4 with latest amendment End cap.
Extra Coupler for 315 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988, Part- II with free solvent cement.
Extra Coupler for 200 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988, Part- II with free solvent cement.
Extra Coupler for 140- mm. dia P.V.C. pipe (extra) I.S 10124/ 1988, Part- II with free solvent cement.
150 mm dia P.V.C.Flexible Hose as per IS 15265
Extra Solvent cement I.S. 14182-1994 with latest amendments
b. M.S / G.I. ACCESSORIES
G.I. Quadrupped Set and Inlet & Outlet Pipe Fittings
150 mm. dia I.S.I. mark and specification, Pn- 1.4 CI sluice valve
C.I. Foot valve ( 150 mm. dia) heavy duty flange type W/t. 28 Kg + 5% IS: 4038/1986 with latest amendment ISI marked (FlangeType).
150 mm dia CI Alfa-Alfa Valve as per specification (IS)
G.I 150 mm dia 90º M.S bend (With priming arrangement) ISI mark
G.I 150 mm dia 90º M.S bend both end flanged as per IS Specification
G.I 150 mm dia E.R.W. Pipe with flange
150 mm dia M.S. Hose Clamp
150mm dia. Nipple one end groved & other end threaded/ both end groved
Foundation Bolt (M.S/G.I.)
For Distrubution Chamber
For Electro motor Pump Sets
Nuts & Bolts (G.I/MS)
Foot valve Lather washer 150mm.dia
Compresed Asbestos fibre jointing for Quadruped & Tripod set( for raised surface of Flange as per IS-6392) 500mm.dia(Table-5)
Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to I.S. 638/79 with ISI mark with latest ammendments ( for raised surface of Flange as per IS-6392)
300 mm.dia( Table-11)
300mm.dia( Table-5)
200mm.dia( Table-11)
200mm.dia( Table-5)
150mm.dia( Table -17)
150mm.dia( Table -5)
80 mm.dia(Table-17)
Supply and transportation of 150 mm dia. C.I. Tail Piece with Flange adopter one side groved and other and flanged Over all length (175+15) mm with 7 now groves
Supply Sal wood sleeper 0.6X0.15X0.25 m
CI Non Return Valve flanged ends & swing type with side by-pass arrangement conforming to IS 5312(Part-1/2004 with latest ammendments
B. SUPPLY OF ELECTRICAL MATERIALS
200A,500V A.C.T.P&N Main switch(Fuse gripType) IS:13947(Pt-III)/93
63A,500V A.C.T.P&N Main switch(Fuse gripType) IS:13947(Pt-III)/93
380/415 V 3Ph 50Hz Oil immersed starter IS:-13947(pt-4/Sec-I)/93 for 15-25HP
20 HP Electro-Motor Pumping Sets with chasis 18 mtr Head
200 A Bus Bar Chamber
200 Amp Cut out
4 inch Round protection type Ammeter MIAC range 0-50Amps IS:1248/68
4 inch Round protection type Voltmeter MIAC range 0-500 V IS:1248/68
C. LAYING OF WTA, CONSTRUCTION OF P/H AND INTERNAL WIRING OF PH
Construction and laying of WTA includs trench cutting , laying of different diameter of PVC Pipe , treanch filling , Construction of Spout Chamber include earth cutting sand filling brick works , Construction of Distribution Chamber includes of C.C and RCC works , Construction of Pump House , Internal Wiring etc . Rates is inclusive of all taxes ( Details schedule is attached in Sheet 2)
SAMAR KUMAR DAS
MAMONI ENTERPRISE
MANIK CHOUDHURY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .