Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.9 LAccepted-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC L bidder | |
| 2 | L2₹65.7 L+₹82,952 (1.28%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹68.5 L+₹3.6 L (5.48%)Rejected-Finance AT PO PS NEAR INDIAN OIL PETROL PUMP WARD NO 03 CHANDRASEKHARPUR BHUBANESWAR MCD DIST KHURDA ODISHA | BHUBANESWAR | KHURDA | ODISHA | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | - | Rejected-Technical Not enlisted in eligible category as per NIT | |
| 5 | Rejected-Technical | - | Rejected-Technical Enlisted in eligible category but for maintance and repair only |
Tender Value
₹62.5 L
EMD Value
₹1.2 L
Closing Date
8 Nov 2022, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
PROVISION OF FIRE ALARM SYSTEM IN GANDHI BLOCK, MAIN BLOCK, VCC, VVIP AT CDM SECUNDERABAD AND PROVN OF FIRE FIGHTING SYSTEM FOR SERVER ROOM IN IT CENTRE AT CDM SECUNDERABAD UNDER GE (UTILITY) SECUNDERABAD
2022_MES_547939_1
CWE (S)/ UTILITY /TOKEN - 13 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
Secunderabad
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (Utility) Secunderabad
₹1.2 L
Yes
20 Dec 2022
26 Aug 2022
15 Nov 2022
26 Aug 2022
8 Nov 2022
26 Oct 2022
Amount
Supply, Installation, Commissioning and testing of Clean Agent Storage cylinder, high pressure seamless carbon steel cylinder, Test Pressure @ 300/ 250 bar, working pressure @ 200 bar and diameter 356 mm, PESO Approved, Capacity -100 Ltrs, HFC-227 complete all as specified and directed.
Supply, Installation, Commissioning and testing of Clean Agent Storage cylinder, high pressure seamless carbon steel cylinder, Test Pressure @ 250 bar, working pressure @ 150 bar and diameter 267 mm, PESO Approved, Capacity - 80Ltrs,, HFC-227 complete all as specified and directed.
Supply, Installation, Commissioning and testing of Valve assembly (Brass), safety burst disc and a safety cap, Inlet & outlet port for actuation hose connection for operation during multi cylinder system to operate the inline master and slave cylinders, Valve DN 42 complete all as specified and directed.
Supply, Installation, Commissioning and testing of Pressure Gauge cum Switch for monitoring the cylinder pressure, Pressure Gauge with Switch 60 Bar N/O complete all as specified and directed.
Supply of HFC 227 ea Gas (1,1,1,2,3,3,3 Hepta flouro propane), Zero ODP, Stored Pressure 25BAR complete all as specified and directed.
Supply, Installation, Commissioning and testing of Electric Control Head (Solenoid actuator) used for releasing the GAS, Electrically operated, Voltage range 24VDC, Ambient Temperature 55 Degree Celsius, Protection class IP65, Mounted over the cylinder valve, Electrical Actuator M42 complete all as specified and directed.
Supply, Installation, Commissioning and testing of Manual (Mechanically Operated) Control Head (Brass) to operate the system, pulling the mechanical lever with help of Stainless Steel wire and Manual Pull station, Mounted over the Solenoid actuator, Manual Release complete all as specified and directed.
Supply and installation of Manual Pull Station along with glass covered box(M.S) complete all as specified and directed.
Supply and fixing of Stainless Steel Wire 1.5 mm dia complete all as specified and directed.
Supply and fixing of Wire Sleeve (Steel wire runs into the aluminum conduit via a system of pulleys provided at each bend). OD 10 mm ID 8 mm.Complete all as specified and directed
Supply and fixing of Corner Pulleys used to change the pipe directions and smooth running of SS wire complete all as specified and directed.
Supply and fixing of End of Line for Stainless Steel Wire and End of Line for Gas Flooding System complete all as specified and directed.
Supply, Installation, Commissioning and testing of Flexible discharge Hose, route the HFC227ea Agent from the storage cylinders to the discharge pipe by a flexible rubber hose with wire braided reinforcements. This hose is connected to the discharge outlet of HFC227ea cylinder valve and terminates at the system pipe or discharged manifold, Discharge Hose (Min) complete all as specified and directed.
Supply, Installation, Commissioning and testing of Brass discharge nozzles designed to provide the proper flow rate and distribution of HFC227ea agent to total flood hazard area : 180 / 360 degree, End connection, female thread type (NPT/BSPT), Gas discharge nozzle -50 NB,360 Degree complete all as specified and directed.
Supply, Installation, Commissioning and testing of M S Container Strap for mounting and fixing the Agent containers to the wall, C Channel Dia 232 complete all as specified and directed.
Supply, Installation, Commissioning and testing of Conventional Gas Release Panel with battery back up and cross zoning facility, Fire Extinguishing Control Panel complete all as specified and directed. Specifications as under:- Power : 220-240 VAC 50 Hz Wire size : 1.5 Sq mm with 600V insulation Battery (Lead Acid only) Charging Voltage : 28 VDC Charging Current : 0.5 Amps (max) System Quiescent Current : 100mA Initiating Device Circuit (Zone Circuit) All Zone are class B wiring Normal Operating Voltage : 14-21 VDC Alarm Current : 15-30mA Short Circuit Current : 40mA Maximum Loop resistance : 50 ohms Maximum End-of-line Resistor : 4.7K. 1/4watt Standby Current : 6.8mA (2.4mA for detectors) Releasing agent circuit Operating Nominal Voltage : 24 VDC Solenoid output : 0.75A End-of-line Resistor : 4.7K. 1/4wall (for solenoid output) Remote outputs 1 Form C relay for fire, Fault and Cross Zoning Contact Rating : 2A@ 30 VDC & 0.5A @125VAC 24 VDC Power For remote devices (optional) Operating Voltage : 24 VDC. 300mA Max Supervised 1No Operating Nominal Voltage 24 VDC Operating Current 0.75A (Max) End-of-line Resistor 4.7K. 1/4watt Non-Supervised 2 Nos Operating Nominal Voltage 24 VDC Operating Current 0.3A (Max) End-of-line Resistor 4.7K. 1/4watt Dimension- (400W x 300H x 100D ) Color - Red/White Construction- 18 Gauge (1.22mm) CRCA sheet with powder coated finish IP Rating- IP50 Cable Entry- 09 x o 19mm Knockout in top of the cabinet Weight Weight- 7 Kg 24 VDC Output for Monitor Module End of line Resistor 2 Zone gas Release Panel 2 Zone Gas Release Panel
Supply, Installation, Commissioning and testing of Manual Release Switch. The Manual Call Point operates as electrical emergency hold device for gas extinguishing systems, (CF_HM/5/11/18/02) MANUAL CALL POINT / BLUE/CONV/STOP complete all as specified and directed.
Supply, Installation, Commissioning and testing of Manual Abort Switch. The Manual Call Point is used as electrical activation device for gas extinguishing systems, (CF_HM/1/11/17/02), MANUAL CALL POINT / YELLOW/CONV/HAND complete all as specified and directed.
Supply, Installation, Commissioning and testing of Conventional Optical Smoke Detector with double dust trap chamber design, optimized performance using internal algorithm, central LED for 360 degree status Visibility, complete all as specified and directed.
Supply, Installation, Commissioning and testing of conventional detector Mounting Base for Smoke and heat detectors, complete all as specified and directed.
Supply, Installation, Commissioning and testing of Conventional Rate of Rise Heat Detector, heat alarm threshold temperature 58 degrees celcius, central LED for 360 degrees status visibility, complete all as specified and directed.
Supply, Installation Commissioning and testing of internally Conventional Sounder Beacon (Banshee) Red c/w shallow base (CF-BANSHEE EXCEL LITE) complete all as specified and directed.
Supply and laying of 2 Core x 1.5 Sq.mm Copper, Armoured control power Cable for Voltage grade 1100 volts complete all as specified and directed.
Supply and fixing of C.S./M.S. Seamless Pipe fittings (forged screwed/socket weld upto 50NB) and M.S. supports viz, angle, channel, plates clamps etc, as per ASTM A-106, SCH-40, Pipe Fittings and Supports for HFC-227 Systems complete all as specified and directed.
Notes for item No 1 to 24 : (i) Make : Ceasefire or equvivalent make of Reliance / Zeco Wizmart / Notifier/ Safex/ Flame guard indus / Nitin/ Vimal fire control Pvt Ltd / Agni/ Indian Fire Equipment systems/ Classic fire Protection/ HD Fire products. (ii) Contractor has to submit the design of fire fighting, prepared by authorised OEM and duly vetted by Govt approved Fire Safety Officer and take prior approval from Engr-in -charge
Supply, Installation, Commissioning and testing of Ceasefire 10 Kg Ceiling Mounted Fire Extinguisher, Clean Agent HFC- 236 FA, Zero ODP, Stored Pressure Type, Pressure Gauge, Gross Weight 14.8 Kg, empty Weight 4.8 Kg, Can Height 316MM, Diameter 300MM, Discharge Time less than 10 Secs, Auto discharge mechanism on temperature rise, applicable on fire Class A,B,C and electrically started Fire, Can Construction : Deep drawn and CO2, Mig welded, Valve Construction: Forging and Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 2.0 MM, Helium Leak Detection Tested and 6 Years Warrantycomplete all as specified and directed. Make : Ceasefire - Product Code CF-000771 or equivalent as approved by GE
Design,supply, installation, testing and commissioning of fire detection and alarm system consisting of followings
Supply , Commissioning and testing of Wireless PowerG Smoke and Heat Detector : Cover range- 01 to 100 cubic meters, Dimensions - 125 x 63mm (5 x 2.5in), Battery Life - 3 years (typical use), Battery Type - 3 AAA batteries (included), Weight - 243g (8.75oz), Operating Temperature - 4.4°C to 37.8°C (40°F to 100°F), Operating Environment - Indoors
Supply , Commissioning and testing of Wireless PowerG Powermaster 30, Supports 64 wireless Zones, Up to 32 keypads, 32 keyfobs, 8 sirens, 4 repeaters, 1 wired zone, 1 wired siren. Supports Zone wise SMS and Voice Calls up to 4 phone numbers.Arming and Disarming through SMS/Call. Built-in Keypad, Battery and Power Supply. Built-inSiren of 85dB, 1 PGM. Supports 3 Areas, 1 Common Area. Two way Talk/Communication / Control - Arm/Disarm/Trouble/Status over GSM/Landline .
Supply ,commission and testing of Wireless PowerG Siren Strobe : Battery Type - s independent Lithium H/5A,3/6V,3 F. Weight Including Battery - 970g (340oz), Operating temperature - -33°C to 70°C (-24.4F°to158°F), Operating Environment - Out door, Dimensions - 295*186*63mm . (11.63*7.31*2.5In)
Make for item No 27.1 to 28 : Ceasefire//Honeywell or techno commercial equivalent as approved by GE. Note For item No 26.1 to 27 : Quoted Rates shall be deemed to be inclusive of the following :- (i) Detailed Design for installation of the wireless heat / smoke detectors, siren and control panel as per the site condition . (ii) Necessary Electric connection for Wire Less Control Panel. (iii) Testing of Complete System after Installation as per PS clause to be done by authorised rep of manufacturer till completion of defect liability period and test report to be submitted duly signed by User, JE, AGE and GE. (iv) Warranty for all the items for two years (v) Make of detector , control panel and siren to be same . (vi) Quoted rates shall be deemed to be inclusive of all arrangements required for installation and proper functioning of Detectors, Siren and Control Panel.
S&F for 10 Ltrs high pressure water mist caf fire extiguisher back pack of following specification Make: CF-000981SF OF CEASEFIRE/ASKA or equivalent make as approved by GE Technology - High Pressure Water Mist & CAFS Capacity (size) - 10 Ltrs. (As per EN 3-7 :2004+A1:2007) Working Pressure -31 Bar Water cylinder Capacity - 10 liters Water Cylinder construction -Aluminum Alloy Water Cylinder Working pressure - 31 Bar Water Cylinder external paint - The cylinder should be of red color with powder coating. The paint should confirm to IS:5:2007 Shade 538 Back pack harness - 1. The harness system shall be made out of synthetic fire resistant material confirming to IS 15758(Part4) and shall provide minimum stress and fatigue to the wearer. 2. The system shall be designed ergonomically. 3. Shall provide maximum maneuverability to the wearer. 4. The back plate shall be constructed from a strong, carbon composite material 5. Shall be rigid, anti-static and highly resistant to impact, chemicals, flames and high temperatures. Air Bottle Capacity - 2 liters/200 bar Air Bottle - construction - Mild Steel
item No.28 contd... Air Bottle - markings - 1. Chief Controller of Explosives/model number/serial number / year of manufacture/Chief Controller of Explosives approved valve with built in pressure gauge 2. The serial number on the cylinder shall match with the Air Bottle - Universal cylinder holder - Shall hold 2 liters to 6 liters capacity cylinders.Air Bottle – pressure gauge - EN (European Standards) pressure gauge. Air Bottle - operation - Shall be able to operate easily while hand held as well as when used as back pack Air Bottle - propellant- Compressed normal air Air Bottle - certification - PESO (Petroleum and explosive safety organization) Approved Portability - Hand Held & Back Pack Total weight Filled - Not more 26 kg (Water Bottle filled & Air bottle 02 liters / 200 bar air filled) Operating/Working pressure - 31 Bar Operating - temperature - Minimum +5 degree to maximum +60 degree Celsius Gun - construction - Stainless Steel Body Gun - weight without hose - Should be 800 gm. ± 2% Hose Length - Minimum 1.3 Meter Gun - Belt - Heat retardant (tolerating up to 150 degree Celsius) and acid resistant, synthetic fiber belt, Long enough to adjust depending Jet - Lancing Distance - 13.2 meters.
item No.28 contd... Jet - Discharge duration-Continuous and at full throttle - 40 to 42 seconds Consumption of extinguishing agent - 0.23 to 0.25 liters per second Water Bottle - Pressure release mechanism to decompress the water bottle - Pressure release mechanism to decompress the water bottle shall be provided for fast refilling Device operation - Shall be suitable for both left and right hand operations Fire extinction suitability - Class – A Fires Class – B Fires Class – B Polar Solvent Fires Live Electrical fires - 1000 V as per EN 3-7:2004+A1:2007 Tested for 35 kV System Test : Electrical Test Certificate - With details of test methods - Tested from ERDA as per EN 3-7:2004+A1:2007 for Dielectric test Product Certificates: Certification from NABL accredited Lab and/ or any Central Govt. Lab. (tested in Indian condition) as per EN 3-7:2004+A1:2007 (tested within last 5 years). Test report shall be enclosed along with the Fire Rating Certificates with standard AFFF 6% foam: For Class A - Minimum 55 A Fire Rating Certificates with standard AFFF 6% Foam: For Class B - Minimum 233 B
item No.28 contd... PED certification - The product should be PED certified to PED 2014/68/EU, ANNEXIII(MODULE H) Warranty - 6 Years ( Subject to maintainance) Spare parts support - For 10 years PESO Licence - The supplier should have a licence from PESO for refilling & storage of high pressure gas cylinders.
Saiansh Associates
Textel Technologies Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .