| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.9 L+₹25,948.60 (1.10%)Rejected-Finance 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹24.7 L+₹1.0 L (4.39%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹25.0 L+₹1.3 L (5.40%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹25.7 L+₹2.0 L (8.37%)Rejected-Finance 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L5 | Rejected-Finance Being L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Jan 2024, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT AND IMPROVEMENT OF LT PANEL INCL LT SWITCH GEAR, EARTHING, TIMER PANEL, LT POLES, POLE BOX, OUTDOOR STREET LIGHTS, FLOOD LIGHTS, AREA LIGHTS, LT DISTR NETWORK AND CONNECTED ITEMS AT MD/OTM ACCN OF GFA, OVL, NVL, 71 INF BDE, CARRIAPPA
2023_MES_619595_2
GE/EM/LKO/EXT(ELECT)/T-38 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹60,000
Yes
29 Jan 2024
14 Dec 2023
8 Jan 2024
14 Dec 2023
6 Jan 2024
21 Dec 2023
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm using excavated suitable soil complete all as specified.
Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
M&L for providing dry river sand as in sand cushioning to under ground cable of any descreption including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose any punned thickness of sand will be considered.)
M&L for laying well burnt old size bricks, sub class "B" bricks, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
M&L for cutting of road / path / hardstading / concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
M&L for cement concrete type C2 1:3:6 (40mm graded stone aggregate) as in foundation / filling of cutting of roads / path / hardstanding and mass concrete all as specified by Engr-in-charge.
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregates for coping of pole etc including necessary form work and demolition of old coping complete all as specified and as directed by Engineer-in-Charge.
Deployment of manpowe / tools for Boring / drilling (Horizontly) manually / mechanically under existing road max 10 M in width) suitable for passing tubing 40 to 100 mm bore complete all as specified and directed by Engineer in Charge
S&F 80 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
S&F 50 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
S&F 40 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
Material & Laying, jointing and testing in replacement of LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including taking out old LT UG cable complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 13 above but of size 16 Sqmm 4 core
All as per item No 13 above but of size 25 Sqmm 4 core
All as per item No 13 above but of size 35 Sqmm 3.5 core
All as per item No 13 above but of size 50 Sqmm 3.5 core
All as per item No 13 above but of size 95 Sqmm 3.5 core
All as per item No 13 above but of size 120 Sqmm 3.5 core
All as per item No 13 above but of size 240 Sqmm 3.5 core
M&L for Earthing in replacement complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor / wall all as described in electric plate No 3 of SSR Part I complete all as specified and directed and testing on completion.
Earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing.
M&L for disconnecting the existing cable from Panel / Pole, preparing the end for jointing Supply and fix cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 / 4 core 10 to 16 Sqmm
All as per item No 23 above but size 25 to 50 Sqmm
All as per item No 23 above but size 70 to 120 Sqmm
All as per item No 23 above but size 150 to 185 Sqmm
All as per item No 23 above but size 240 to 300 sqmm
Supply & Fix in replacement twin core, 6 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.
Supply & Fix in replacement twin core, 10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.
Supply & Fix connecting and testing in replacement MCCB 63 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply & fix connecting and testing in replacement MCCB 100 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply & fix connecting and testing in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply & fix connecting and testing in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply & fix connecting and testing in replacement MCCB 200 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply & fix connecting and testing in replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply & fix connecting and testing in replacement MCCB 400 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply & fix connecting and testing in replacement MCCB 630 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply and fix in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz, complete with sheet metal enclosure of 1.6 mm thick MS sheet factory made with powder coat paint including connecting with existing system with existing cablling network including making good disturbed surfaces complete all as specified and directed. Note : The cost of suitable size fastner / Nut bolts required at site for fixing of cubical is deemed to be included in the quoted rate by the contractor.
Supply and fix in replacement MCB 20 Amp 2 pole 10 KA, 250 volts 50 Hz, complete with sheet metal enclosure of 1.6 mm thick MS sheet factory made with powder coat paint including connecting with existing system with existing cablling network including making good disturbed surfaces complete all as specified and directed. Note : The cost of suitable size fastner / Nut bolts required at site for fixing of cubical is deemed to be included in the quoted rate by the contractor.
Supply drawing, connecting and testing in replacement 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
M&L for Preparation of old painted surfaces of LT steel tubular pole 9 mtrs long and applying one coat aluminium paint from bottom to top and painting up to 1.5 mtr height from top of PCC coping with synthetic enamel paint one coat in black and Yellow / white alternate strip including re writing pole numbering in 8 cm height with one coat synthetic enamel paint complete all as specified & directed by Engineer –in-Charge.
M&L for Preparation of old painted surfaces of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour complete all as specified and directed.
Supply, installing, testing and commissioning in replacement factory made, CPRI approved, powder coated LT Panel board (Dimention of Cubical / enclosure not less than 1700 mm x 1200 mm x 600 mm), cubical compartmentalized, out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50 x 50 x 6 mm thick MS angle iron frame work, the cubical have bottom channel of size 75 x 40 mm duly powder coated, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 36 KA, with microprocessor release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole ,320 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 01 Nos (ii) MCCB 4 pole ,200 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 01 Nos (iii) MCCB 4 pole ,125 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 01 Nos (iv) MCCB 4 pole ,160 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 01 Nos (v) MCCB 4 pole ,100 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 01 Nos
(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
All as per item No 43 above but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 05 Nos
All as per item No 43 above but comprising with following:- Size - 1200x800x500 mm (a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 03 Nos
Supply and installed steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300 x 300 x 6mm thick at bottom, welded at the centre with through hole of 14mm dia at a height of 300 mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer with writing number including excavation upto required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 5 mm thick in 1:3 cement mortar complete all as specified and directed.
M&L for out door type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm) made out of 3.15 mm thick MS sheet and MS angle section 50 x 50 x 6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 400 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three. (d) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Dismetling and taking down old / unsv ACSR conductor any size from pole complete all as specified and directed.
S&F ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin / shackle insulators with aluminium binding wires and required jumpering connection all as dercted. Note :- Size of aluminium conductor as per site requirement will be directed by Engineer-in-Charge.
Dimentling and taking down old / unsv insulator of any type any size from pole / stay complete all as specified and directed.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100 mm height and 65 mm dia for 1100 volts grade all as specified and directed.
S&F shackle type, porcelian vitreous white, brown or green insulator including galvanised mild steel straps, washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
S&F Loop type insulator, porcelian vitreous brown of size 65 x 90 mm and clearence hole 16 mm all as specified and directed.
Dismantling of existing old damage PCC pole of any description complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB DP 40 Amps including taking down old and unserviciable.
Taking out LT UG aluminium conductor cable of size 16 Sqmm to 35 Sqmm 4/3.5 core 1100 Volt grade for fault checking and relaying same cable in same trenches including excavation, returning filling, taking out brick cable cover & sand cushning, relaying same cable cover and sand cushion complete all as specified & directed.( Straight through joint will be measured & paid seperatly.
Taking out LT UG aluminium conductor cable of size 50 Sqmm to 70 Sqmm 3.5 core 1100 Volt grade for fault checking and relaying same cable in same trenches including excavation, returning filling, taking out brick cable cover & sand cushning, relaying same cable cover and sand cushion complete all as specified & directed.( Straight through joint will be measured & paid seperatly.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core 16 Sqmm XLPE armoured aluminium conductor cable.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core 25 to 50 Sqmm XLPE armoured aluminium conductor cable.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core 70 Sqmm XLPE armoured aluminium conductor cable.
Supply and fix MCB SP, 6 to 32 Amps including taking down old and unserviciable.
S&F in replacement wheather proof pole mounting PVC junction box, base and door of junction box made out of SMC having outside dimention 333 x 233 x 120 mm, inside dimention 300 x 200 x 105 mm, single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10 Amp -1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing / painting of danger notice of size not less than 10 cm x 7.5 cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge.
Eco Creations
M/s A.K Construction
MTR GROUP & COMPANY
M/S SHIVA CONSTRUCTION
Prime power system
OM NAMAH SHIVAY ENTERPRISES
Unnati Engineers
ANKIT SHIP REPAIRERS AND SUPPLIERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .