Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 1 SHAKTI NAGAR JAMMU JAMMU KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 197 2ND FLOOR S S ELITE 10TH CROSS C B I ROAD R T NAGAR BANGALORE BANGALORE KARNATAKA 560032 | BENGALURU URBAN | KARNATAKA | 560032 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹29.3 L
EMD Value
₹60,000
Closing Date
16 Feb 2026, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Supply, Installation, Testing Commissioning of Fire Alarm System and Fire Extinguishers for Govt. Nursing College, Akhnoor, Jammu
2026_PWDJK_302462_1
MHDJ/e-NIT 352 of 2025-26
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
45 days
Govt. Nursing College, Akhnoor
AS PER E NIT
2 documents required · 2 mandatory
₹1,000
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹60,000
7 Apr 2026
6 Feb 2026
17 Feb 2026
6 Feb 2026
16 Feb 2026
10 Feb 2026
6 Feb 2026 - 16 Feb 2026
Supply of 1 Loop Analogue Addressable Fire Alarm Control Panel expandable up to 4 Loop, loop current 500mA maximum per loop, dual flash based microprocessor, supports to connect 240 addressable devices one each loop via fully digital communication protocol, equipped with a white backlit display (240x64 pixel resolution) graphical LCD Display with at least 6 lines of information, 200 fire zones (soft zones), fully programmable via alphanumeric keypad or configuration software, dedicated USB and RS-232 serial port for direct or PC connection. 5500 events storage, loop current 500 mA, panel shall be equipped with in-built millimeter for live monitoring of loop current, earth voltage, loop voltage etc., installer's logo application, can be networked to compatible addressable panels and repeater panels by adding a network card, features battery charger status and temperature, supports programmable cause / effect on outputs, panel housing meets IP30 ingress protection classification.
Supply of Intelligent Analogue Optical Smoke Detector with advanced optical chamber and smoke inlet design to provide resistance to entry of dust to provide immunity to false alarms, programmable multiple smoke sensitivity level setting, bi-directional in-built short circuit isolator to protect against cable faults, dual bi-color LED's with 360o view of status, auto-addressable/electronically addressed, utilizes fully digital communication addressable protocol with high noise rejection. Approved by LPCB for EN 54-7 & EN 54-17 standard.
Supply of Intelligent Analogue Class-P Heat Detector with two thermal sensitivity level, the two level corresponds to rate-of-rise (ROR) A1R Class (most sensitive) and Class BS (least sensitive), thermal alarm threshold for ROR A1R Class 58oC and BS Class 78oC, bi-directional in-built short circuit isolator to protect against cable faults, dual bicolor LED's with 360o view of status, auto addressable/ electronically addressed, utilizes fully digital communication addressable protocol with high noise rejection. Approved by LPCB for EN 54-5 & EN 54-17 standard.
Supply of Standard Detector Base for mounting the compatible addressable detectors.
Supply of Intelligent Sounder Interface Module allows connecting conventional Sounder or Sounder Beacon to addressable loop, with in-built short circuit isolator, allows for two stage alarm capability, addressed through auto and manual options. Approved by LPCB for EN 54-17 & EN 54-18 standard.
Supply of Intelligent Analogue Multi-Criteria (combination of smoke and heat) Detector with special algorithms to utilize information from both smoke and heat sensing elements to ensure high level of immunity to false alarms without compromising genuine alarm sensing performance, programmable multiple smoke sensitivity level and 9 modes of operation, bi-directional in-built short circuit isolator to protect against cable faults, dual bicolor LED's with 360o view of status, auto addressable/ electronically addressed, utilizes fully digital communication addressable protocol with high noise rejection. Approved by LPCB for EN 54-5, EN 54-7, & EN 54-17 standard.
Supply of Single Loop Driver Card designed for use with compatible analogue addressable panels, provides control and connection/communication to maximum 240 addressable device per loop.
Supply of Intelligent Analogue Manual Call Point with resettable operating element, with in-built bidirectional short circuit isolator. Bi-Color LED for local indication of device status, single action operation, reset to normal condition using special reset key, clearly visible alarm flag in the activated state. Approved by LCPB for EN 54-11 standard.
Supply of Mounting Accessories like back box for detectors, devices & cable glands, etc.
Supplying and laying of 2C x 1.5 Sq.mm PVC insulated copper conductor armoured cable encased inside (by providing and laying) 1.5” dia PVC insulated conduit/pipe along with fittings and fixtures. Complete Job includes cost of material (PVC conduit, Cu Cable). labour and transportation.
P/F of wall mounted automatic Fire Extinguishers ABC type of capacity 6 Kg using two heat sensing quartzoid bulb with valves for detection & extinguishing of fires, Wall Mounted Automatic Fire Extinguisher Powder Based (as per IS 4308) Automatic, Mild Steel, Hose Length 500 millimeter, Quartzoid bulbs temperature rating 68 degree Celsius, Pressure Testing-PED Certificate/ CE Marking to PED 2014/68/EU, Annexure 3 (Module H) from EU Notified Body.
P/F of Stored Pressure Water Mist Based Fire Extinguishers 6 liter Capacity. Bs En Standard Based Portable Fire Extinguishers, Conformity to Standard "EN 3-7 + A1: 2007 & EN 3-8;2006 with latest amendment, Weight of Filled Portable Fire Extinguisher (kg) 10.438, Suitable for Class -A fire ratings as per EN 3-7 13A, Fire Rating for Class -F 75F,Operating Temperature (-30° C≤ N >=60° C ), Warranty for the Complete Product 5 year, Operating Temperature (+5° C to + 60° C), Service Pressure 15 bar, Burst Pressure 112 bar, Minimum Discharge Time (seconds) required as per EN Standard 12 second, Shelf Life (Life Cycle) of the Fire Extinguisher 10 Years, Marine Equipment Directive (MED) Approved CE Certification from EU Notified Body, CE Identification Number of the Notified Body (Must Declare),CE 1128, Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification Test Report No 1329b, Issue: 04, Test Report Date 20.07.2018 Name of the Lab BRE Global Ltd.
P/F Water Mist & CAF High Pressure 50 Ltrs. Trolley (As per EN 1866-1:2007-08), working Pressure 31 Bar, Air Bottle Capacity 6 Litre 300 Bar Pressure, Approved By PESO (Petroleum and explosive safety organization),Fire extinction - suitability with standard AFFF 6% confirming to IS 4989 or UL 162 standards Class – A Fires, Class – B Fires, Class – B Polar Solvent Fires, Live Electrical fires - 1000 V as per EN 3-7:2004+A1:2007 Tested for 35 kV, Certification from NABL accredited Lab and any Central Govt. Lab. (tested in Indian condition) as per EN 1866-1:2007-08. Test report shall be enclosed along with the offer, The product should be PED certified to PED 2014/68/EU, ANNEXIII (MODULE H), The supplier should have a license from PESO for refilling & storage of high pressure gas cylinders.
stage.html
html • 0.03 MB
cancelled_1.pdf
pdf • 0.08 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
BOQ_981540.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .