Closing Date
27 Dec 2021, 11:00 amClosed
Executive Engineer
Ranbir Club Sangrur
Boring and installing 200mm id depth 150 mtr BGL with REVERSE Rotary rig against failed tw Providing and Installing New Pumping Machinery Rising main 110mm od and refitting of C.I delivery main 100 mm id and Cholorinator etc. complete in all respect
2021_WSS_79248_1
WSSD/2021-22/71
Open Tender
Civil Works
Item Rate
90 days
Sangrur
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹22,000
27 May 2022
14 Dec 2021
27 Dec 2021
14 Dec 2021
27 Dec 2021
14 Dec 2021
Amount
TUBEWELL
Drilling of 500 mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site complete in all respect.
up to 150 mtr
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness
Supplying, fixing of lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
200mm Steel Strainer (slot size 0.75mm) 6.30 mm thickness
Supplying, fixing and lowering of Stainless Steel Socket as per IS: 8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore complete in all respect
200 mm internal diameter
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect.
200 mm internal diameter
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Drilling of 9” trail bore with hand boring machine including rate for electric logging ( electric Logging shall be carried out by contractor up to full depth) complete in all respect. Water sample of water wearing strata which are suitable for pumping out water shall be tested for physically & chemically analysis heavy metal & uranium. The rates for testing will be separate paid against Tube well relevant item of this bid. cared
Collection of water samplbe from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect
200 mm internal diameter
Supplying & fixing of ball plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
(c) 200mm internal diameter (weight 33.6 kg per metre) 6.40 mm thickness
Supplying & fixing of M.S. Clamp of size 150mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Development of stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from dust, dirt or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per acual length of pipe)
Ceiling of unpotable strata.
Testing of water sample for Heavy metal/Uranium from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, uranium etc.)
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc. Complete in all respect
Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respect.
Providing and fixing sanitary seal, clasy seal and sterilization of well on completion of tubewell as per BIS: 2800: 2019 complete in all respact
Providing Local sand
PUMPING MACHINERY
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 351 LPM against a head of 74 mtr 10.00 BHP" along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including M.S. Column Pipe of suitable size 80mm=53 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable 4.00 mm2 = 100 mtr. (reputed make) complete in all respects as per standard Specifications.
Credit of only old machinery & Coulmn pipe , Submersible cable & Panal board propty of department
RISING MAIN (Tubewell to OHSR & bye pass)
Providing, Laying, fixing & jointing of P.V.C pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specificationa. (110 mm o/d 10 kg cm2 pipe)
C.I.FITTING OUTSIDE PUMP CHAMBER
Dismantling & Reinstalling 100 mm dia delivery main (from Tubewell to duck foot bend including cost of C.I D/F Pipes, D/F Sluice Valves, D/F NRV, V-Notch & Specials as C.I. Bends , Tail Piece, Tees etc. inside the Pump Chamber as per standard design complete in all respects as per Annexure A12-2 & Drawings D-12 & D-17.
CHLORINATOR
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering Syatem, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressurSe upto 7 kg.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications.
GURSHARAN SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .