| Sl No | Description | Qty | Unit | Horizon Construction L6 | S Y Itkar Construction and Company L1 | Sayili Enterprises L4 | SUN Enterprises L3 | Sarkar Enterprises L9 | A K ENTERPRISES L5 | AMW Construction and developers L7 | AAK ENTERPRISE L2 | M/S CDRATHOD INFRATECH PRIVATE LIMITED L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out Any Kind Of Soil soil and disposal of surplus excavated soil within a lead of 50 m complete all as specified and directed by engineer incharge. | 10 | Cum | 198 ₹1,980 | 350 ₹3,500 | 170 ₹1,700 | 500 ₹5,000 | 750 ₹7,500 | 210 ₹2,100 | 299 ₹2,990 | 120 ₹1,200 Lowest | 150 ₹1,500 |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out Ordinary Rock and disposal of surplus excavated soil within a lead of 50 m complete all as specified and directed by engineer incharge. | 12 | Cum | 450 ₹5,400 | 350 ₹4,200 | 300 ₹3,600 | 1,200 ₹14,400 | 2,500 ₹30,000 | 240 ₹2,880 | 650 ₹7,800 | 299 ₹3,588 | 200 ₹2,400 Lowest |
| 3.00 | Excavating in post holes in soft /loose soil (or similar holes) each n exc 0.5cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n exc 25cm complete all as specified and directed by engineer incharge. | 10 | Each | 99 ₹990 | 60 ₹600 | 35 ₹350 Lowest | 500 ₹5,000 | 150 ₹1,500 | 90 ₹900 | 110 ₹1,100 | 250 ₹2,500 | 50 ₹500 |
| 4.00 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil. complete all as specified and directed by engineer incharge. | 100 | Sqm | 27 ₹2,700 | 80 ₹8,000 | 37.5 ₹3,750 | 50 ₹5,000 | 70 ₹7,000 | 60 ₹6,000 | 29 ₹2,900 | 25 ₹2,500 Lowest | 40 ₹4,000 |
| 5.00 | Demolition of Cement Concrete (Unreinfocement) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by engineer incharge. | 10 | Cum | 99 ₹990 Lowest | 150 ₹1,500 | 350 ₹3,500 | 500 ₹5,000 | 600 ₹6,000 | 360 ₹3,600 | 449 ₹4,490 | 1,150 ₹11,500 | 150 ₹1,500 |
| 6.00 | M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation filling & mass concrete complete all as specified and directed by engineer incharge. | 5 | Cum | 4,230 ₹21,150 | 2,200 ₹11,000 Lowest | 2,800 ₹14,000 | 5,000 ₹25,000 | 3,100 ₹15,500 | 2,400 ₹12,000 | 3,450 ₹17,250 | 4,500 ₹22,500 | 3,200 ₹16,000 |
| 7.00 | M&L precast cement concrete 1:3:6 type C-1 ( using 20mm graded stone aggregate ) block masonry with solid blocks exc10 cm thick in width and setting in cement mortar (1:6) complete all as specified and directed by engineer incharge. | 10 | Cum | 6,300 ₹63,000 | 6,000 ₹60,000 | 5,200 ₹52,000 | 5,500 ₹55,000 | 3,500 ₹35,000 Lowest | 4,500 ₹45,000 | 5,949 ₹59,490 | 5,500 ₹55,000 | 5,500 ₹55,000 |
| 8.00 | Supply only integral water proofing liquid admixture for concrete and mortar, ISI marked complete all as specified and directed by engineer incharge. | 2 | Ltr | 198 ₹396 | 150 ₹300 | 150 ₹300 | 100 ₹200 | 90 ₹180 | 75 ₹150 Lowest | 345 ₹690 | 100 ₹200 | 100 ₹200 |
| 9.00 | S&F Mild steel Rolled sections as in Compound girders and stanchions, Column ,gusset plate ,lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices,clit etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc(including welding & Bolteded connction where required). Fe 410-W (Gde E-250) quality B complete all as specified and directed by engineer incharge. | 2,800 | Kg | 108 ₹3,02,400 | 89 ₹2,49,200 Lowest | 115 ₹3,22,000 | 118.37 ₹3,31,436 | 120 ₹3,36,000 | 99 ₹2,77,200 | 110 ₹3,08,000 | 121 ₹3,38,800 | 110 ₹3,08,000 |
| 10.00 | S&F Mild steel for Rolled sections (tubular section) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, including welding 7 bolted connection) Fe 410-W (Gde E-250) quality B complete all as specified and directed by engineer incharge. | 600 | Kg | 108 ₹64,800 | 89 ₹53,400 Lowest | 116 ₹69,600 | 120 ₹72,000 | 125 ₹75,000 | 114 ₹68,400 | 102 ₹61,200 | 121 ₹72,600 | 110 ₹66,000 |
Tender Value
₹30.7 L
EMD Value
₹61,360
Closing Date
18 Sept 2025, 6:00 pmClosed
GE (P) NDA KHADAKWASLA
GE (P) NDA KHADAKWASLA
ADDN/ ALTERATION TO TT SHED IN ATT AREA AT NDA KHADAKWASLA UNDER GE (P) NDA KHADAKWASLA
2025_MES_727080_1
8159/E8
Open Tender
Civil Works
Item Rate
GE (P) NDA KHADAKWASLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(P) NDA KHADAKWASLA
₹61,360
Yes
5 Feb 2026
21 Aug 2025
22 Sept 2025
21 Aug 2025
18 Sept 2025
4 Sept 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out Any Kind Of Soil soil and disposal of surplus excavated soil within a lead of 50 m complete all as specified and directed by engineer incharge.
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out Ordinary Rock and disposal of surplus excavated soil within a lead of 50 m complete all as specified and directed by engineer incharge.
Excavating in post holes in soft /loose soil (or similar holes) each n exc 0.5cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n exc 25cm complete all as specified and directed by engineer incharge.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil. complete all as specified and directed by engineer incharge.
Demolition of Cement Concrete (Unreinfocement) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by engineer incharge.
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation filling & mass concrete complete all as specified and directed by engineer incharge.
M&L precast cement concrete 1:3:6 type C-1 ( using 20mm graded stone aggregate ) block masonry with solid blocks exc10 cm thick in width and setting in cement mortar (1:6) complete all as specified and directed by engineer incharge.
Supply only integral water proofing liquid admixture for concrete and mortar, ISI marked complete all as specified and directed by engineer incharge.
S&F Mild steel Rolled sections as in Compound girders and stanchions, Column ,gusset plate ,lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices,clit etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc(including welding & Bolteded connction where required). Fe 410-W (Gde E-250) quality B complete all as specified and directed by engineer incharge.
S&F Mild steel for Rolled sections (tubular section) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, including welding 7 bolted connection) Fe 410-W (Gde E-250) quality B complete all as specified and directed by engineer incharge.
S&FPre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by engineer incharge.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550Mpa (AZ-150) as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by engineer incharge.
M&L for RCC Type C-2 1:3:6 (40mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts(including caps and bases) complete all as specified and directed by engineer incharge.
M&L for Hardcore of gauge n exc. 63mm,brocken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by engineer incharge.
M & L for Rolling and consolidating formation surfaces in cutting by power roller of capaity exc 8 tonne & n.exc. 12 tonne complete all as specified and directed by engineer incharge.
M & L for PCC 1:3:6 type C2 (Using 40 mm graded stone aggregate) 100 mm thick Cement concrete in sub-floors, sub-bases, floors and pavings etc including necessary formwork complete all as specified and directed by engineer incharge.
M&L for PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) 70 mm thick Cement concrete in sub-floors, sub-bases, floors and pavings etc including necessary formwork complete all as specified and directed by engineer incharge.
M&L for Moorum filling in floors or pavings, laid in layers n exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and directed by engineer incharge.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar(1:4) complete all as specified & as directed by Engineer-in-charge
S&F factory made 100% SOLID WOOD PLASTIC COMPOSITE (WPC) door frame of size 90 mm X 45 mm made from wood plastic composite (single extruded process) material with density 780 kg /cbm .The door frame shall be fixed to the wall using 65/100 mm long M S Screws through the frame by using PVC fasterners . A minimum of 4 nos of screws to be provided for each vertcal member & minimum 2 nos for horizontal member etc. complete as per specifications and as directed by Engineer-In-Charge.
S&F factory 28 mm thick factory made three layer rigid PVC/WPC door shutter made 100% solid PVC flush shutter 28 mm thick , made from co - extruded three layer rigid PVC foam sheet ( single extruded) with density not less than 600 kg /Cbm outer layer 1 mm thick should be of rigid PVC with density of not less than 1400 kg/cbm manufactured by an ISO 9001-2015 certified company as per manufacturers specification & drawing complete all as specified and directed by engineer incharge.
S&F 100mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-12 complete all as specified and directed by engineer incharge.
S &F 125mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed by Engr-In-Charge.
S & F 125 mm Size of Brass handles, cast type, polished bright complete all as specified and directed by engineer incharge.
Use and waste of form work to sides of concrete foundation, footings, base of column, sides and soffit of plinth beam ,Floor beam,rough finished Dressing with oil, white-wash, soft soap or other approved substance to prevent adhesion .complete all as specified and directed by Engr-In-Charge.
Use and Waste of form work to sides of column, pillars , post , struts, pier rough finished.Dressing with oil, white-wash, soft soap or other approved substance to prevent adhesion complete all as specified and directed by Engr-In-Charge.
Use and Waste of form work to Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. rough finished. Dressing with oil, white-wash, soft soap or other approved substance to prevent adhesion complete all as specified and directed by Engr-In-Charge.
M&L TMT bars 10mm and over dia cut to length bent to shape required incl cranking, bending, spirally for columns hooking ends binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engr-In-Charge.
M&L for TMT bars 5 mm dia and over as in stirrups spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. complete all as specified and directed by Engr-In-Charge.
M&L for RCC (Design mix) M-25 using 20mm graded aggregate as in Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-In-Charge.
M&L for RCC (Design mix) M-25 using 20mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-In-Charge.
M&L for RCC (Design mix) M-25 using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-In-Charge.
M&L for rendering 15mm thick in CM (1:4) Ext Wall on other than fair faces of brick/concrete work finishing even & smooth without using extra cement. complete all as specified & as directed by Engineer-In-Charge
M&L for rendering 15mm thick in CM (1:6) Internal Wall on other than fair faces of brick/concrete work finishing even & smooth without using extra cement complete all as specified and directed by engineer incharge.
M&L preparation of old steel surfaces of any description , n. exc.10cm width or girth & aplying two coats of synthtic enamel paint, complete all as specified & as directed by Engineer-In-Charge.
M&L Preparation of new steel Surfaces of any description, exc 10cm in width or girth, not otherwise described and applying two coats of Synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by engineer incharge.
M&L for preparation on newly plastered wall surface and appplying two coats of cement base paint over a coat of alkali resistant primer (External paint), complete all as specified and directed by engineer incharge.
M&L for preparation on old plastered wall surface and appplying two coats of cement base paint over a coat of alkali resistant primer all complete all as specified and directed by engineer incharge.
M&L for Preparing new plastered surfaces of walls applying two coats of distemper oil bound over 3mm thick wall care putty on wall complete all as specified and directed by engineer incharge.
M&L for preparation of old painted surfaces of wall by completely removing existing treatment by scrapping , cleaning , washing with water etc , and applying Two coats of oil bond distember including filing the surface with crack filler wherever required complete all as specified and directed by engineer incharge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in hard dense soil. complete all as specified and directed by engineer incharge.
Spreading and levelling including watering and as ramming as required of Any kind of soil / ordinary rock in layers n exc. 25 cm thick complete all as specified and directed by engineer incharge.
M&L for taking down old unserviceable copper/aluminium point wiring of any type (light, fan, socket or power) surface conduit/ casing capping complete, including fixture and fittings such as switches/sockets, ceiling roses, pendants, regulators, light fitting etc.and making good disturbed surfaces of walls, floors, beams, trusses etccomplete all as specified and directed by engineer incharge.
M&L for point wiring (Concealed wiring) of any length using approved colour coding as per IS, with multi stranded copper conductor of size 1.5 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS-H cable 1100 volts grade in and including PVC rigid conduits heavy duty, medium grade, ISI marked (Min 20mm dia ) (size of conduit shall be according to maximum numbers of wires permissible to be drawn as per IE Rule) with valid CML No, totally concealed in wall/floor and surface conduit/casing capping along roof /ceiling including all accessories as required complete including GI Metal Flush boxes of min thickness 1.0 mm with modular frame/cover plate of suitable size for mounting modular switches/sockets etc. and PVC insulated multi stranded FRLS-H copper conductor of size 1.5 Sqmm single core cable (Green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed by engineer incharge for the following:-
One light point controlled by one switch one way type
One 3 pin 5 Amps socket outlet point on Same board
All as per item No 44 above but with 2.5 sqmm copper conductor FRLS-H (multistrand), 1100 volts grade PVC insulated, ISI marked unsheathed cable in and including concealed PVC conduit, heavy duty ,ISI marked, medium grade with valid CML No not less than 20 mm dia with all fitting & accessories as required and including PVC insulated ISI marked, unseathed, FRLS-H copper conductor cable of size 2.5 sq mm (Green Colour) as earth conductor and connecting to common earth dolly for one three pin socket outlet 15 Amps complete all as specified and as directed by engineer incharge
Note for Item Sr No 44.01, 44.02 and 45;- (i) The cutting in chases and pointing in brick wall/Stone Wall/ any type of wall /beam and providing wire mesh over chase cutting before cement plastering to avoid development of cracks on surface of wall shall be done by contractor without any extra cost. (ii) The making good of distrubed surfaces, matching with adjoining /existing finishes shall be done by contractor without any extra cost. (iii) The contractor shall make the surface good after flushing the sunken boxes as existing without any extra cost (iv) The contractor shall provide circuit wiring of 3 x 2.5 Sqmm FRLS-H copper wire from DB to switch board and rate for the same is deemed to be included in unit rate of item. (v) The length of Point Wiring for light points shall be of suitable length as per site requirement and according to location of fittings as directed by Engr in Charge. The cost of this is deemed to be included in the cost of work and nothing extra on this account is admissible. (vi) The cost of Blanking plate for switch board as per site requirement is deemed to be included in the cost of work and nothing extra on this account is admissible.
M&L for point wiring (Surface wiring) of any length using approved colour coding as per IS, with multi stranded copper conductor of size 1.5 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS-H cable 1100 volts grade, in and including PVC rigid conduits heavy duty, heavy grade (HMS), White colour, ISI marked (Min 20mm dia , size of conduit shall be according to maximum numbers of wires permissible to be drawn as per IE Rule)) with valid CML No. through surface conduit along roof /ceiling/beam/trusses (conduit to be fixed on truss by providing clamps etc ) including all accessories as required complete including Modular PVC surface boxes with modular frame/cover plate of suitable size for mounting modular switches/sockets etc. and PVC insulated multi stranded FRLS-H copper conductor 1.5 Sq.mm single core cable (Green colour) as earth conductor and connecting to common earth dolly all as specified and directed by E in Charge for the following:-
One light point controlled by one switch one way type
One 3 pin 5 Amps socket outlet point on Same board
One 3 pin 5 Amps socket outlet point on independent board
All as per item No 46 above but with 2.5 sqmm copper conductor FRLS-H (multistrand), 1100 volts grade PVC insulated, ISI marked unsheathed cable in and including concealed PVC conduit, heavy duty ,ISI marked, medium grade with valid CML No not less than 20 mm dia with all fitting & accessories as required and including PVC insulated ISI marked, unseathed, FRLS-H copper conductor cable of size 2.5 sqmm (Green Colour) as earth conductor and connecting to common earth dolly all as specified and directed for one three pin socket outlet 15 Amps.
Note for Item Sr No 46.1, 46.02 and 47 - (i) Making good of distrubed surfaces, matching with adjoining /existing finishes shall be done by contractor without any extra cost. (ii) Contractor shall make the surface good after fixing the PVC Surface boxes as existing without any extra cost (iii) Contractor shall provide circuit wiring of 3 x 2.5 Sqmm FRLS-H copper wire from DB to switch board and rate for the same is deemed to be included in unit rate of item. (iv) Length of Point Wiring for light points shall be of suitable length as per site requirement and according to location of fittings as directed by Engr in Charge. The rate of the same shall be deemed to included in quoted rates. (v) Contractor shall provide Blanking plate for switch board as per site requirement without any extra cost to department.
S&F modular switch, one way, 6 Amps, one module, white colour, 240 V complete all as specified and as directed by engineer incharge.
S&F modular socket 6 Amps 2/3 pin, two module, white colour, 240 V, complete all as specified and as directed by engineer incharge.
S&F modular switch, one way, 16 Amps, one module, white colour, 240 V complete all as specified and as directed.
S&F modular socket 6 Amps /16 Amps 2/3 pin two module, white colour , complete all as specified and as directed by engineer incharge.
S&F ceiling rose, 3 terminals / PVC / Polycarbonate, isolated body complete all as specified and as directed by engineer incharge.
S&F LED Tube light fitting 24 watt, surface / wall mounted LED batten housing made of aluminium extrusion with high efficient LED`s, opal diffuser, IP 20, with system efficacy of 100 lm/W , colour temp 6500 K, 50 Hz, 240 V complete including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to connector of light fittings, incl 2 x PVC mounting box for fixing of lightcomplete all as specified and as directed by engineer incharge Make - Halonix Cat Part No- HLB-03-24-CW-AL-SQ or Luker - LUMOS PRIMO Aluminium tube set-LT5M24 or techno commercial equivalent model in makes as per Appendix 'C'
S&F LED tube light 36 W, corrosion resistant luminaire with polycarbonarte housing and opal diffuser, IP 65 and with system efficacy of 120lm/w, Color temp 6500k complete including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to connector of light fittings complete all as specified and as directed by engineer incharge Make - Halonix Cat Part No - HLB-04-36-CW or techno commercial equivalent model in makes as per Appendix 'C'
S&F LED Flood lights , 150W, High performance floodlight luminaire with pressure die-cast aluminium housing, toughned glass with direct PC lens, IP 66, Potted driver with SPD, with system efficacy min 120 lm/W, 6000k Color temp, intregral type including of all fixing arrangement to fix light fitting on TT Shed by providing nut bolts, other accessories including welding all as per site requirement complete all as specified and as directed by engineer incharge Make - Halonix Cat part No - HLFLD-ML27-150-CWDL-R-P or techno commercial equivalent model in makes as per Appendix 'C'
Note for Item Sr No. 53 to 55 here - in - before : - The contractor shall arrange his own T & P for mounting / fixing of light fittings in TT shed with mounting height upto 9.0 mtr without any extra cost to the department.
S&F LED Security light fittings 30 Watt with PDC aluminium housing with energy efficient LEDs, Direct modular IP Lens, IP 66 with potted driver and with system efficacy of min 125 lm/watt complete with all accessories such as MS flat iron clamp - 02 Nos , nut, bolts, GI pipe mounting bracket min 32 mm dia of length upto 1.5 mtr etc, prewired, connecting light fitting to light source (ceiling rose) with sheathed three core flexible copper wire in PVC flexible pipe of 15 mm dia complete all as specified and as directed by engineer incharge. Make - Halonix cat part no - HLSLD-09-30-CWL-R or techno commercial equivalent model in makes as per Appendix 'C'
S&F DB Box, in sheet metal enclosure DB VTPN, MCCB DB VTPN 4 way, double door with MCCB as incomer (Suitable for mounting a 100 Amp MCCB) and suitable for SP/TP DB outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 150 Amp fully insulated copper bus bar for each phase, with 2 Neutral bar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, reversible door provision, including blanking plates and circuit identification labels, including flushing and fixing DB box neatly in wall / solid block wall including copper lugs/thimbles duly crimped for connection complete all as specified and as directed by engineer incharge. Make- Legrand Cat Part No. 5077 46 Model: (Ekinox-3) or techno commercial equivalent model in makes as per Appendix 'C' Note: (i) MCCB and DB box shall be of same make. (ii) MCCB shall be measured & paid seperately
S&F MCCB with Thermal - magnetic release of 63 Amps, 3 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting as per IS-13947 & IEC 60947-2 including all accessories like spreader terminals and face barriers including making all electrical connections by providing lugs of suitable size complete all as specified and as directed by engineer incharge. Note: (i) MCCB and DB box shall be of same make.
S&F MCB SP 6 to 32 Amps 240V, 10 KA breaking capacity, C curve as per IS/EC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and as directed by engineer incharge.
M&L for Earthing complete with galvanised steel pipe electrode, 40mm bore medium grade, 2.5 metres length, buried directly and preferably vertically in ground in bore of 150 mm dia, 3 mtr depth in any type of soil/ soft/ hard/ disintergrated rock/ hard rock and connected with earthing lead of 4mm dia galvanised iron or steel wire (all as shown in Plate No. 2 to the earthing test point all as specified and indicated including 15 mm dia GI medium grade pipe for protection of GI wire to the extent of 7.5 metres as earthing lead including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth electrode, including PCC chamber of size 300 x 300 x 300 made up of PCC 1:3:6 type C1 & MS angle iron 25 x 25 x 5 mm frame embeded in copping of earth pit of PCC 1:2:4 with MS sheet cover of 3 mm thick with lifting and locking arrangement and painted with two coats of yellow colour over one coat of red oxide primer, 20 mm dia medium grade G.I. watering Pipe along the pipe electrode upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement included earth work/boring in any type of strata and testing complete all as specified and as directed by engineer incharge. Note :- (i) The cost of earth protection pipe & earthing lead wire upto and including 7.5 m length is deemed included in the quoted rate and nothing extra on this account. (ii) The cost of all T&P for drilling of bore at site in any type of strata for placing/ buried the GI pipe earth electrode below ground deemed to be included in quoted rate of work and nothing extra on this account is admissible.
Supply of Pedestal fan metal body of sweep 600mm, aerodynamically designed three metallic blades, min air delivery 270 CMM, 1440RPM, with double ball bearing, adjustable upward / downward tilt mechanism height upto 1650 mm with 60 Degree oscillation, thermal overload protection motor, corrosion resitance, all as directed by Engr - in - charge. Make - Havells FHACPSTSCL24 Turboforce 1440 rpm Pedestal Fan or techno commercial equivalent model in makes as per Appendix 'C'
AAK ENTERPRISE (BID ID -3421428)
SUN Enterprises (BID ID -3422829)
Sayili Enterprises (BID ID -3422519)
A K ENTERPRISES (BID ID -3422703)
Horizon Construction (BID ID -3421867)
AMW Construction and developers (BID ID -3429363)
M/S CDRATHOD INFRATECH PRIVATE LIMITED (BID ID -3422545)
Sarkar Enterprises (BID ID -3428572)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .