Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹11.8 L+₹1.5 L (14.0%)Rejected-AOC 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L2 | Rejected-AOC Reject | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted category c (i) | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted category c (i) |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
7 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
Kanjoli Line GE Bharatpur pin 321026
REPAIR/MAINTENANCE OF COOLING APPLIANCES AND ALLIED SERVICES UNDER GE BHARATPUR
2021_MES_439935_2
8030/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Bharatpur
As per tender docu
7 documents required · 7 mandatory
₹500
GE Bharatpur
₹28,000
Yes
4 Sept 2021
16 Jun 2021
9 Jul 2021
16 Jun 2021
7 Jul 2021
20 Jun 2021
17 Jun 2021 - 19 Jun 2021
60 days
Amount
Taking out and Servicing of window type air conditioner cap-1.5TR/ 2.0TR incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting the same complete all as specified and as directed
Taking out and servicing of split type air conditioner cap- 1.5/2.0 Ton incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete all as specified and as directed
Shifting of AC of any type of AC capacity 1.5/2.0 Ton including taking out brackets, pipe line and fixing insulating pipelines including brazing of copper tubes, testing/commissioning complete, the shifting of service connection and voltage stabilizer to the new location complete all as specified and as directed Note: The rates shall also include transportation, civil work and making good to the disturb surfaces.
Labour only for attending complints for repairsand rectification of window/split AC of any capacity i.e. leakage in copper tubes, compressor, condensor unit & checking of capacitor ( Running & Starting) ,cleaning of filters, checking of thermostat,checking of regfrigerant pressure and filling refrigerant gas , including noting the complaints in compliant register complete all as directed by Engineer - in - Charge.(Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter) Note:- 1.The complaints shall be attended and the defetcs shall be rectified by experiened ref mechanic with adequate No of helpers as directed by Engineer-in-charge 2. supply items shall be measured and paid separetely under respective item. 3.The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. 4.In case , after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. 5.All T&P required for attending the Complaints shall be provided by the contractor.
Supply only following items for window/ Split AC of any capacity: (a) Compressor for AC Capacity- 1.5 Ton for window/split AC (as per site requirement) as per existing make or any other make mentioned In Appx.
Compressor for AC Capacity- 2.0Ton for window/split AC (as per site requirement) as per existing make or any other make mentioned In Appx.
Refrigerant R-22/410/134a (suitable as per requirement)
Starting Capacitor 80-100 / 100-120 MFD, Make : TESLA/ Godrej or Equivalent make approved by GE. as mentioned in Appx
Running Capacitor 36 MFD/ 45 MFD, Make : TESLA/ or Equivalent make approved by GE. as mentioned in Appx
Fan blade of blower as per sample or directed
Screen filter of air conditioner of cap - 1.5 / 2.0 TR as per existing make.
Front PVC grill as per existing size/model for window type AC cap 1.5 TR/ 2 TR
Strainer alongwith capillary tube suitable for 1.5 Ton capacity window type air conditioner . Make : RANUTROL or Equivalent make approved by GE
Starting relay suitable for window and split type AC. Make: SRIRAM or Equivalent make approved by GE
Thermostatic switch suitable for split type AC 1.5/2.0 Ton capacity of existing make.
Fan motor with fan blade unit suitable for 1.5 Ton capacity window type air conditioner of existing make.
Condenser's fan motor with blade suitable for split type air conditioner
Electronic panel board / PCB of Airconditioner cap- 1.5TR/2TR .
Plastic water drain hose pipe, 15mm dia and 2mm thick of wall for spit type AC .
Remote control operating device for Window/Split type AC of 1.5/2.0 Ton with 02 Nos of pencil battery of existing make.
Aerofoam NBR rubber insulation tube of dia 5/8" for split type AC upto 2.0 Ton for insulation of copper tubes .
Display for split type AC upto 2.0 Ton
Pencil batteries for remote of split/window AC.Make: duracell
Copper tubes of size 4/8, 1/2 inch
Copper tubes of size 3/8,5/8, 1/4 inch (Note for Srl item No 5 to 5.2 here in before: Fixing shall be measured and paid under respective item)
Labour only for attending complints for repairsand rectification of Electric Water cooler of any capacity i.e. leakage in copper tubes, compressor, condensor unit & checking of capacitor ( Running & Starting) , checking of regfrigerant pressure and filling refrigerant gas, cleaning of water cooler body , including noting the complaints in compliant register complete all as directed by Engineer - in - Charge.(Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter) Note:- 1.The complaints shall be attended and the defetcs shall be rectified by experiened ref mechanic with adequate No of helpers as directed by Engineer-in-charge 2. Supply only item shall be measured and paid separetely under respective item. 3.The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. 4.In case , after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. 5.All T&P required for attending the Complaints shall be provided by the contractor.
M & L for painting of water coolers of Cap - 150/150 Ltrs by cleaning old deteriorated exterior surface and necessary prepartion of surface by scrapping rust, grease, dirt etc before applying two coats of synthetic enamel paint of Make : Asian Paints Ltd ( Ist quality) or equivalent of approved colour by using spray painting technique to match with existing colour at existing location complete all as specified and directed by Engr in charge.
Ditto all as per Srl Item No 7 here in before but of Water cooler capacity 80/40 Ltrs.
Supply only following items for electric water cooler of any capacity: (a) Compressor unit for water cooler 150/150 Ltrs of existing make or any other make apporved by GE mentioned in Appx.
Compressor unit for water cooler 80/40Ltrs of existing make or any other make apporved by GE mentioned in Appx.
Refrigerant Gas R-134a/R-22 (suitable as per requirement)
Condenser fan motor with fan blade for water cooler of any Cap of existing make or any other make apporved by GE mentioned in Appx.
Capacitor 25/35 MFD, ISI marked.
Thermostat with knob as per existing size and make.
Relay with overload protection assembly
Magnetic rubber gasket as per existing size and make
Drain water tray of stainless steel by brazing/soldering the joints, vent pipes, outlet etc as per existing size and make
Pencil type strainer alongwith capillary tube suitable as per existing size and make.
Float valve PVC 15mm bore, heavy duty. (Make: Prayag, Surya) (Note : Fixing shall be measured and paid under respective item)
Supply and fixing in replacement of chromium plated push cock size 15 mm suitable or as per existing for water cooler of any cap, type and make complete all as specified and directed by Engr in charge. Make: Liberty/Onida/CSON
Supply and fixing in replacement of PVC flexible pipe size 40 mm dia with necessary clamping with jubli clips for drain water tray as per existing suitable for water cooler complete all as specified and directed by Engr in charge.
Replacement of PVC connection of size 15 mm dia 450mm long rayon branded pipe with brass CP nuts and nylon washers complete all as specified and directed by Engr in charge.
Labour only for attending complints for repairsand rectification of Refrigerator/Deep freezer of any capacity i.e. leakage in copper tubes, compressor, condensor unit & checking of capacitor ( Running & Starting) checking of regfrigerant pressure and filling refrigerant gas , including noting the complaints in compliant register complete all as directed by Engineer - in - Charge.(Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter) Note:- 1.The complaints shall be attended and the defetcs shall be rectified by experiened ref mechanic with adequate No of helpers as directed by Engineer-in-charge 2. supply only item shall be measured and paid separetely under respective item 3.The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. 4.In case , after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. 5.All T&P required for attending the Complaints shall be provided by the contractor.
Supply only following items for Refrigerator/Deep freezer of any capacity: (a) Compressor unit for Regrigerator of cap 165-195Ltrs of existing make or any other make apporved by GE mentioned in Appx.
Compressor unit for Regrigerator of cap 200-300Ltrs
Compressor unit for Regrigerator/Deep freezer of cap 300-400Ltrs
Rrefrigerant Gas R -22/R-134a (suitable as per requirement)
Starting relay suitable for existing refrigerator. Make: SRIRAM or equivalent make approved by GE
Thermostatic switch auto defrost type with knob suitable for existing refrigerator
Bulb inside the refrigerator suitable for existing refrigerator
Magnetic rubber door gasket suitable for existing refrigerator
Push type door switch suitable for existing refrigerator
Door lock with two keys suitable for existing refrigerator
Overload protector suitable for refrigerator . Make: INDFOSS/DANFOSS or equivalent make approved by GE
Strainer pencil type alongwith capillary tube suitable for refrigerator as per existing capacity
Ice tray suitable for refrigerator complete all as specified and directed by Engr in charge.
Egg /lemon tray suitable for refrigerator complete all as specified and directed by Engr in charge.
Vegetable tray suitable for refrigerator complete all as specified and directed by Engr in charge.
Electronic PCB for 320 Ltr refrigerator (Note : Fixing shall be measured and paid under respective item)
Labour only for attending complints for repairsand rectification of desert cooler of any capacity i.e. checking of desert cooler fan motor, submersible pump, socket point, PVC connections,Fan blade, wooden chips etc including noting the complaints in compliant register complete all as directed by Engineer - in - Charge.(Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter) Note:- 1.The complaints shall be attended and the defetcs shall be rectified by experiened ref mechanic with adequate No of helpers as directed by Engineer-in-charge 2. Supply only item shall be measured and paid separetely under respective item 3.The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. 4.In case , after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. 5.All T&P required for attending the Complaints shall be provided by the contractor.
M&L for cutting burnt winding of fan motor of size upto 450mm sweep and rewinding with super enamelled copper winding wire and replacing gun metal bush shaft.complete all as specified and directed by Engr-in-charge
M&L for painting of desert cooler inner and outer surface with spray gun using one coat of red oxide and two coat of anti corrosive synthetic enamaled paint of approved brand as directed by Engr-in-charge
Supply only following items for desert cooler of any capacity: (a) Fan Motor copper wound 18/20" sweep, 3 Speed single phase 230V AC supply complete with Blade (Make: Khaitan/Crompton Greaves/Bajaj/Cool Home/Marathon)
MS Bracket with mounting ring of cooler fan motor and mounting clamps/legs of existing size/model
PVC submersible Pump complete single phase 230V AC supply for desert cooler, 1 meter head or suitable to existing desert cooler. Make: Khaitan/Crompton Greaves/ Bajaj/ Summercool
Side panel/shutter made out of 20 SWG GI sheet as per existing design and approved including handles (2 Nos.) duly welded / riveted
Bottam tank made out of 20 SWG GI sheet as per existing unserviceable tank
Top of the Desert Cooler made of 20 gauge GI Sheet riveted /bolted to match with existing.
PVC water distribution cup with PVC elbow and pipe for any size of cooler
Capacitor cap- 4 MFD, suitable for desert cooler as per existing size. Make: L&T/Epco/Khaitan
Piano switch 5 amps one way
3 pin plug top 5 Amp. Make
1.5 Sqmm copper conductor wire for internal wiring
Float valve PVC 15mm bore, heavy duty. (Make: Prayag, Surya)
PVC connection 45 cm long. (Make: Prayag)
PVC connection 60 cm long. (Make: Prayag)
Wooden chips of suitale size for 03 side shutters of desert cooler (Note : Fixing shall be measured and paid under respective item)
Supply & Fixing plywood 6mm thick with white mica sheet duly fixed in windows with screws for ventilation opening for desert cooler as per existing size complete all as specified and directed by Engr in Charge.
M&L for fixing and grouting of MS Stand (adjustment type) suitable for desert cooler of cap 3000/4000CFM made out of angle iron section of size 50 x 50 x 6 mm complete with two coats of synthetic enammled black paint over a coat of red oxide primer all as specified and directed by Engr in Charge.
Replacement of PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 2.5 sqmm.
Replacement of 3 pin plug top 15 Amp. Make : ANCHOR complete all as specified and directed by Engr in charge.
S&F brass stop cock Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore pipes complete all as specified and directed by Engr in charge
S&F brass stop cock Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 20 mm bore pipes complete all as specified and directed by Engr in charge.
S&F in replacement GI pipe, 15 mm bore, medium grade, ISI marked with fittings laid in trenches or fixed to walls, ducts, floors etc incluiding necessary excavation and earth work complete for desert cooler/water cooler connections all as specified and directed by Engr in charge. (Make: Surya/Prakash/Tata/Jindal)
Ditto all as per Srl Item No 24 here in before but of 20mm bore
S&F sheet metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 volts. Make- L&T, Havells, Legrand complete all as per specified by Engr-in-charge.
S&F in repair voltage stabilizer suitable for window/split type AC, 2. Ton capacity, Rated Amps-15 Amps, voltage variation range between 130 to 300 volts Model VGB 500 Make: V -Guard
S&F in repair voltage stabilizer suitable for Window/ split type AC, 1.5 Ton capacity, Rated Amps-12 Amps, voltage variation range between 130 to 300 volts Model VGX 400 Make: V -Guard
S&F in repair voltage stabilizer suitable for Deep freezer /Refrigerator /water cooler of capacity up to 600 Ltrs, Rated Amps-6 Amps, voltage variation range between 100 to 300 volts Model: VEW 150 make: V-Guard
M&L submain wiring complete with 4 Sqmm single core multi standred copper conductor PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable fire resistant for earth continuity conductor in and including drawn through PVC cassing caping size not less than 20 mm dia with all PVC conceren accessories in surface or ceiling complete all as specified and as directed (Note: 02 runs of 4 Sqmm of copper conductor , 01 run of earth continuity conductor & PVC Cassing caping shall be measured as one length only)
S&F in repair battery charger of 24 Volts 20 Amp suitable for charging batteries upto 250AH with ammeter display an crocodile connector 2Ft in lentgh . Model BC-A31 mak: Magic power ( Nibco)
Uma engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .