| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2.7 L
EMD Value
₹5,410
Closing Date
1 Feb 2025, 6:00 pmClosed
EE Civil Pune
BSNL Civil Division Pune, First Floor Carrier Building, MHS Pune 01
Miscellaneous Civil maintenance works to TE Bldg at Model Colony and MKR , Pune
2025_BSNL_224688_1
e-08/EEC(P)/BSNL/2025/29
Open Tender
Civil Works
Item Rate
60 days
Model Colony Shivajinagar Pune
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
ACCOUNTS OFFICER (Cash) BSNL, Pune
₹5,410
4 Feb 2025
24 Jan 2025
4 Feb 2025
24 Jan 2025
1 Feb 2025
24 Jan 2025
Amount
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) a) 300x16 mm
Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) a) 250x20x6 mm
Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) a) 200 mm weighing not less than 240 grams
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 300x16 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. a) Single rubber stopper
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : a) In 75x75 mm deep chase
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : a) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. a) With cement mortar 1:4 (1cement: 4 coarse sand).
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. a) 10 litre capacity - White
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm / 40mmdia
Providing and fixing uplasticised PVC connection pipe with brass unions : a) 45 cm length i) 15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Removing aluminium partition/false Ceiling including dismembering and seperating members like aluminium pipe, beadings, glass, prelaminated board, grid, fastener, suspenders, grills, door closer/floor spring, door shutter etc. and stacking the material as directed by the Engineer-in-charge.
Erecting/re-fixing aluminum partition with available material at required location and floor and size as per the site requirement including washing/cleaning of old aluminium material (pipes, doors, glazing clips etc.), cutting and joining to required size and shape and fixing at locations using new screws, cleats, neoprene gasket, rubber beading etc. complete and as per the directions of Engineer in charge.
Fixing aluminum door shutters with available material at required location and floor and size as per the site requirement including washing/cleaning of old aluminium material (pipes, doors, glazing clips etc.), cutting and joining to required size and shape and fixing at locations using new screws, cleats, neoprene gasket, rubber beading etc. complete and as per the directions of Engineer in charge. a) size upto 1.20M x 2.10M
Dismantling broken 40mm rigid PVC pipe upto 10Mtr length including cutting and fixing good portion of pipe upto 1.80M length and making hole in brick masonry including making good with cement mortar etc. complete and as per the directions of Engineer in charge.
Repairs to PVC flushing cisterns by removing defective and unserviceable components and replacing with new component as specified and making the cistern operational complete as directed by Engineer-in-charge. a) PVC Handle knob.
b) P.V.C flusher
c) P.V.C float valve .
Removing all plants grown on building upto Four storey height building with jhoola/ladder including taking proper precautions, safety etc, applying acid and filling the holes by cement mortar etc complete as directed by the Engineer in charge.(measurements shall be taken as One Job per Building)
Repairing the wooden flush door by removing the same from position carefully and carrying out the necessary repairs by replacing the unserviceable hinges if any & making it in operational condition and refixing the same at original position and as direction of Engineer in charge ( Note- cost of hinges will be paid in relevant item). a) Door shutter area below 3 Sqm
Repairing the wooden flush door without removing it from its position by keeping it in its position and carrying out the necessary repairs, fastening the hinges with old or new screws if required making it in operational condition etc all complete and as direction of Engineer in charge (Note- Rate inclueds cost of new screws if required ) a) Door shutter area below 3 Sqm
Cleaning of chocked drainage lines in kitchen, bathroom and water closet from inside of staff quarters including removal of all type of blockage and disposal of same, all as per the direction of Engineer-in-charge. a) From European Water Closet (WC).
Cleaning of terrace by brooming, removing leaves/grass and any other material lying on terrace and disposal of material etc. complete as directed by the Engineer-in-charge. (Only in Area as per instructions from the SDE Civil)
Attending leakages in PVC water tank including disconnecting, emptying the tank and reparing by PVC welding and replacing in position, making all connections, checking etc complete as directed by Engineer in charge. Capacity 2001 lit to 5000 lit
Repairs to top layer of existing water proofing treatment as detailed below: (a) Dismantling the top layer of damaged waterprrofing treatment, cleaning the surface with wire brush, broom and applying bonding coat as per the manufacturer specifications etc (b) Applying a base coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (c) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:3 (1 cement :3 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. All above operations to be done in order and as directed and specified by the Engineer-in-Charge.
Providing & fixing PTMT plumbing fixtures of standard make, Prayag, Prince or equivalent ncluding all required neecessary fittings, screws etc. complete as directed by Engineer in charge. a) Bib Cock/Stop Cock
b) Pillar Cock
Repairs to arrest lekage from floor/Nahani trap inlets in Bath room/Wash basin/Urinal/Kitchen by cutting all type of floor of size 300 x 300 mm x 300mm deep around inlet gratings to get access to the mouth of PVC/CI trap, sealing the joint using epoxy sealant putty, providing 100mm or 75mm single piece PVC SWR pipe (matching to inlet size of existing floor trap) upto 300mm length from inlet of trap to the flooring top, refilling the pit with cement concrete 1:2:4 mixed with water proofing compound including disposal of rubbish to the municipal dumping ground all as per direction of Engineer-in-charge.
Disposal of waste / malba by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km, complete as per directions of Engineer-in-Charge. (trip of one brass ie 2.83 Cum)
Transportation of Aluminium partition material (pipes, doors, glazing clips etc.) from exchanges where it is avaialble, to the exchange where it is to be refixed under DGM (West) jurisdiction exchanges, within PMC limit, including necessary loading ,unloading, shifting from & to any floor, making list of material in duplicate and handing over the material to competent authority etc as per direction of Engineer in charge.
Providing and applying Two coats of “Dr. Fixit Raincoat”, Asian Paint Hydrolock or equivalent over one coat of primer of “Dr. Fixit Primeseal", Asian Paint Primeseal or equivalent on external wall surface (prone to leakage due to heavy rain) etc. all complete as per manufacturers specifications in following sequence of operations. a. All new cement-sand renderings /concrete surfaces should be allowed to age 6 to 8 weeks before surface b. Surface for treatment must be thoroughly cleaned of all laitance, loose material, oil, grease, etc. by mechanical means such as wire brushing & shot blasting . c. Finally vacuum cleaning of all loose solids and liquids can be done, if required. d. All surface cracks upto 5 mm width and above should be filled separately (to be paid under different item), e. Prime the surface with Dr. Fixit Primeseal diluted with potable water by volume in 2:1 ratio (2 parts primer and 1 part water) and allow it to dry for 2 to 3 hours f. Use Raincoat directly from the container (Stir contents well before use), Apply two neat coats of Raincoat without dilution by brush or roller at a time interval of 5-6 hours on rain lashing walls, chajjas and parapet walls. g. Allow the coated surface to air cure fully for 7 days.
Dismantling G.I. pipes (external work) including plugging the dead end & taking out the pipes, stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : a) 15 mm to 40 mm nominal bore
Providing and fixing APVC pipes, including all APVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step APVC solvent cement and testing of joints complete as per direction of Engineer in Charge. a) 32 mm nominal outer dia. pipes.
Providing and fixing APVC Union in APVC pipe line, including cutting and fixing with cement solvent etc complete (New work) a) 32 mm nominal outer dia. pipes.
Providing and fixing APVC Brass MTP/FTP fittings in APVC pipe line, including cutting and fixing with cement solvent etc complete (New work) a) 32 mm nominal outer dia. pipes.
Extra for arranging Jhulaa/Ladder to carry out plumbing work to 12m-15m height from ground level including labour for holding Jhulla/ladder and plumber etc. Complete as per direction of Engineer-in -Charge.
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure jetting sewer cleaning machine including skilled operator for cleaning and partial de-silting of manholes and de-chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth.
Credit for the recovered items after dismantling or replacing the damaged items etc. a) GI pipes
N K CONSTRUCTION (BID ID -814525)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .