| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹67,000
Closing Date
23 Jan 2023, 4:00 pmClosed
Project Manager E
Sanat Ghar Bemina
Electrification work at SAM Degree College Budgam
2023_SICOP_202092_1
14- SICOP PME of 2022-23 dated 10.01.2023
Open Tender
Miscellaneous Works
Item Rate
30 days
Sanat Ghar Bemina
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
Project Manager E
₹67,000
Yes
11 Feb 2023
10 Jan 2023
24 Jan 2023
10 Jan 2023
23 Jan 2023
10 Jan 2023
Amount
Wiring for the following light points &exhaust fan points with 1.5Sqmm PVC insulated copper wires of approved make in concealed or surface mounted PVC conduit including providing and fixing of 6 Amp single pole switch of approved quality in modular grid plate and GI box and Earthing of fixtures and the outlet box with 1.5sqmm PVC insulated copper wire a) One light controlled by 6 Amp Switch
Wiring for 240 volts single phase and neutral 16 amps switched socket outlet with 2 x 2.5sqmm PVC insulated copper wire in concealed or surfaced mounted PVC conduit including providing and fixing of 16amp 3 pin switched socket in G.I boxes with modular grid plate and earthing the third pin of socket outlet with 1sqmm PVC insulated copper wire complete as required
Wiring for 240 volts single phase and neutral 16 amps switched socket outlet with 4sqmm PVC insulated copper wire in concealed or surfaced mounted PVC conduit including providing and fixing of 16amp 3 pin switched socket in G.I boxes with modular grid plate and earthing the third pin of socket outlet with 1.5 sqm PVC insulated copper wire complete as required
Wiring for ceiling fan /wall fan point same as above in item No1 but controlled by electronic stepped regulator and 6amp control switch.
Wiring for 230v ac 5- pin 3 x 6 amp socket out let for light duty power with 230v ac 6 amp sp switch on same modular grid plate with 2x2.5 sqmm PVC insulate copper wire of approved make and earthing the third pin of socket outlet with 1 sqmm PVC insulated copper wire complete as required
Wiring for 230v ac, 5pin 6 amps socket outlets for light duty power with 2x1.5sqmm PVC insulate copper wire of approve make with modular grid plates and earthing the third pin of socket outlet with 1.5 sqmm PVC insulated copper wire completes as required
Wiring for circuits for light/fan/exhaust fans/AC, s etc with following size PVC insulated 1100v Grade multi strand copper conductor wire, green insulated multi strand copper conductor for earth wire in the existing conduits complete including connections all the three wires for phase, neutral and earth shall have to be taken to switch board and then distributed further. (Without Conduits) a) 2x2.5Sq.mm + 1x1.5 Sq.mm
2x1.5sqmm
2x6sqmm +1x4sqmm
Supplying installation testing and commissioning of pre wired industrial socket including 32-amp SP MCB complete with connection as required
Supplying and fixing of following size dia PVC conduit including cost of junction boxes, bends, elbows, sockets, tees etc. laying in slab cutting, chases and making good or surface mounted including all fixing hardware as required. a) 25mm dia
35mm dia
Supplying installation testing and commissioning of pre wired 15 watt led light complete with connection as required
Supplying installation testing and commissioning of pre wired ceiling fan complete with connection as required
Supplying installation testing and commissioning of exhaust fan complete with connection as required a. 200mm
Supplying and fixing following way, Prewired TP&N PPI Distribution Board of Sheet Steel for 415 Volts on surface/Recess complete with Ready to use DBs - Provided with 100A insulated phase bus-bars, neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identification labels. The D.B should be IK-09 Compliant. (The Cost of D.B is without MCB’s) (IP Rating-43) A) 6-way (8 Module Incomer), (2+2+2 incomer DP RCCB), (4+4+4) SP MCB's O/G's)
Supplying and fixing of following size mcb’s complete with connection as required make Schneider. a) 6–32-amp SP
40-amp TPN
63 amp TPN
Design, fabrication, assembling, supply, installation, testing and commissioning of LT main panel out door canopy type suitable for 415 V 3 phase 4 wire power supply system panel shall be fabricated out of 1.6mm thick CRC sheet powder coated free stand, having front doors mounted on angle iron pedestal and necessary wiring and other penal accessories comprising of the following Incomers A) 320 amp 4 pole 36ka MCCB B) Spreaders links & phase barriers C) 400 amp TPN alu BAS BAR D) Digital multifunction meter E) Indication lumps Out goings F)100Amp 4p MCCB 36ka 3 no G)Speeders links and phase barriers H)63 Amp TPN 3 no
Wiring for sub main circuits with following size PVC insulated 1100v Grade multi strand copper conductor wire, green insulated multi strand copper conductor for earth wire in the existing conduits complete including connections all the three wires for phase, neutral and earth shall have to be taken to distribution board from main penal board. (Without Conduits) a) 4x25 Sqmm+ 10 Sqmm
b) 4 x 10 sqmm+6 Sqmm
Supplying laying of following 1100-volt grade XLPE insulated PVC sheeted aluminum conductor arromed cable as per specification in existing trenches cable trays ducts over bed of sand clamps including fixing bolts connecting testing and commissioning a) 185 sqmm 3.5 core
SITC of I/O module complete box Rj-45 socket and front plate complete with connection on socket side(computer point)
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recess as required (for internet and CCTV)
SITC of 24 port patch penal complete as required
Supply installation testing and commissioning of enterprises level layer 2 switch, fully manageable ,(24port ) 10/100/1000 Rj45 ports, (4) SFP ports, (2) combo 10-100-1000 ports and external RPS connector, complete as per specifications as desired by
Supplying and fixing of 12u network rack fully loaded complete as required
Supplying and fixing of 1 meter patch cord complete as required.
SITC of micro processor based intelligent addressable two loop main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimium 4000 events history login the non volatile memory (EPROM) power supply unit (230 +/-5%V.50Hz) 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to have seamless integration with analog/digital voice. Honeywell notifier, Simens, Apolo or approved make
SITC of intelligent analog addressable photo thermal detector complete with mounting base complete as required.
SITC of intelligent addressable programmable sounder complete as required.
SITC of addressable manual call point complete as required
Supply and drawing of 2 C x 1.5 sqmm Un armoured cable.
Supplying and Fixing of following sizes of PVC conduit along with Accessories in surface / recess including painting in case of surface conduit, cutting the wall and making good the same in case of recessed conduit as required . 25mm dia.
M/S ZAIRE INDUSTRIES
M/S BLUE STAR ELECTRICAL AND MECHANICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .