| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 CrAccepted-AOC YOGESHWARI NAGARI RING ROAD AMBAJOGAI | AMBAJOGAI | BEED | MAHARASHTRA | ₹44.8 Cr Quoted ₹45.3 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹46.1 CrRejected-AOC | ₹46.1 Cr | L2 | Rejected-AOC Reject |
| 3 | L3₹47.2 CrRejected-AOC HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹47.2 Cr | L3 | Rejected-AOC Reject |
| 4 | L4₹47.5 CrRejected-AOC THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹47.5 Cr | L4 | Rejected-AOC Reject |
| 5 | L5₹49.5 CrRejected-AOC | ₹49.5 Cr | L5 | Rejected-AOC Reject |
Tender Value
₹45.0 Cr
EMD Value
₹22.5 L
Closing Date
30 Mar 2021, 6:55 pmClosed
Executive Engineer Public Works Division Beed
Executive Engineer Public Works Division Beed
Construction of Extension of 200 Bed District Hospital at Beed Tq. and Dist. Beed
2021_PWR_663653_1
PWD_Beed/14/2020-21
Open Tender
Civil Works
730 days
BEED
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,360
₹22.5 L
Chief Engineer,Public Works Region,Aurangabad
24 Aug 2021
15 Mar 2021
1 Apr 2021
15 Mar 2021
30 Mar 2021
15 Mar 2021
19 Mar 2021
Amount
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 Metre including removal and disposal of top organic soil not exceeding 150 mili metre in thickness.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 Metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift from 1.50 metre to 3.0 metre) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 Metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift upto 1.50 metre) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 Metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift from 1.5 to 3.0 metre.) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 Metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift from 3.0 to 4.5 metre.) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 Metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift from 4.5 to 6.0 metre.) By Mechanical Means
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 Cement Mortor diametre about 30 -60 centi metre deep at 15 centi metre centre to centre as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.
Filling in plinth and floors with approved excavated material in 15 centi metre. to 20 centi metre layers including watering and compacting etcetera complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 centi metre to 20 centi metre including watering and compaction etcetera complete.
Shifting & disposing of excavated material up to lead of 10 km. as directed by engineer in charge.
Providing soling using 80 mili metre size trap metal in 15 centi metre layer including filling voids with Crushed sand/grit, ramming, watering etcetera complete.
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etcetera as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etcetera complete.
A) Ground Floor
F) Fifth Floor
Providing and fixing in position Thermo Mechanical Treated (TMT) - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetera as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 mili metre to 450 mili metre section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etcetera as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
A) Ground Floor
F) Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetera columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/ pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for Reinforced Cement Concrete canopy as per detailed designs and drawings including steel centering, formwork, laying/ pumping, compacting and roughening the surface if special finish is to be provided and curing etcetera complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A) Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/ pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
F) Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and applying two coats of protective membrane over the cured concrete surface like Reinforced Cement Concrete footings, columns, plinth beams etcetera which will be submerged under soil so as to protect the same. Apply two pack coal tar epoxy system of Sunepoxy Coaltar of approved make & approved by Engineer in charge, having solid content ranges from 80-100%, Tack free time 4-6 hrs. Recoat after 16-24 hrs. Mix Part A and Part B of Sunepoxy Coaltar of approved make & approved by Engineer in charge in 1:1 ratio with slow speed stirrer and apply the same on a clean Reinforced Cement Concrete surface by brush. Allow to set for 8-10 hours and apply the second coat. The rate to include for application at all levels to various Reinforced Cement Concrete elements to the satisfaction of the EIC etcetera complete.
Providing & Supplying corrosion inhibiting admixture in concrete to protect steel bars for all concrete in every part Polyalk CP 293 of approved make & approved by Engineer in charge migrating, non-nitrite based corrosion inhibiting admixture shall be added at a dose of 3 Kilograms per Cubic Metre of concrete. The admixture should protect both cathodic and anodic sites and have been accredited by Indian Roads Congress, recommended for use by Ministry of Road Transport & Highways and should have a 4 year track record of use in both the Gulf Region and Indiametre Admixture should have evaluated test reports demonstrating a corrosion rate of zero coulombs after 9 test cycles as per ASTM G 109 when tested from a research institution NBA accredited Grade A and internationally ranked among top 5 research institutions in the world in Annual Survey conducted by Georgia Institute of Technology ranking of research institutions. PH of admixture should be alkaline in nature, specific gravity of 0.99 – 1.1, colour : brownish. The contractor must intimate the engineer in charge prior to addition in concrete for recording. If the admixture is put in the concrete mix at the batching plant, a written record of the amount of admixture used shall be supplied to the engineer. The engineer must ensure that the specified dosage of admixture is added in the concrete mix. (Material Cost Analysis only)
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in Cement Mortor 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etcetera complete.
Providing Second class fly ash brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mili metre diametre / two hoop iron strips 25 mili metre x 1.60 mili metre at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing fly ash brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetera Complete
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying damp proof course 50 mili metre thick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etcetera complete.
A) Ground Floor
Providing water proof bedding for flooring of Bath and Water Closet 25 mili metre thick in Cement Mortor 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing & laying water proof treatment of terrace slab with Brick Bat Coba in all position with an average thickness of 150 mili metre consisting specialised materials as per the manufactures specifications and covering 10 years guarantee on court fee stamp paper including all lead, lift, etcetera complete.
F) Fifth Floor
Providing and laying Hyperplas Aluminium or equivalent polymeric multiple monolithic five layer water proofing flexible, pliable and high tensile strength membrane (3 Kilogram/Square Metre) which is comprise of top with "V" shape embossed 40 micron Aluminium foil to bear thermal expansion and avoiding delamination & consist of centre core of 90 micron thick High Molecular High density Polyethylene film (HMHDPE) which is protected on both the side with polymeric mix. Applying the membrane by thermofusing to roof & parapet after applying thin film of hot blown bitumen 85/25 or 90/15 grade @ 1.2 Kilogram/Square Metre maximum as per surface condition or Hyperplas primer @ 250 grams/Square Metre as per site condition on the surface to be treated with 10 centi metre overlapping including finishing etcetera complete and covering guarantee of 7 years on stamp paper of Rs. 100/- and as directed by Engineer-in-charge. (Prior permission of S.E.in writing is necessary before inclusion of this item in estimate).
Providing and fixing 20 to 25 mili metre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mili metre depth, filling the joints with 6 mili metre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etcetera complete. (excluding Cement concrete 1:3:6 base concrete )
Providing and fixing 20 to 25 mili metre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mili metre between rough shahabad and Reinforced Cement Concrete walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mili metre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etcetera complete. (excluding Cement concrete 1:3:6 base concrete)
Providing internal cement plaster 12 mili metre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mili metre thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mili metre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing & applying Dezzly texture paints of Hammer/Screetech on the external plastered surface of approved quality etc. complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 mili metre thickness to previously plastered surface / or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing fine cement finish 1.5 mili metre thick over green plaster surface including scaffolding curing etcetera complete.
A) Ground Floor
Providing patti/ band 75 mili metre wide on plastered surface 12 mili metre to 15 mili metre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etcetera complete.
A) Ground Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centi metre width at the junction of Reinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /Burnt Brick Masonry and or tying by binding wire etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and applying one pack bonding coat between concrete members like Reinforced Cement Concrete slabs, columns, beams, chajjas, pardis etcetera and cement mortar plaster using Hack Aid Plast of approved make & approved by Engineer in charge. Clean the concrete surface thoroughly to remove dust, dirt, grime, deshuttering oils and rub down to a clean surface. Apply Hack Aid Plast of approved make & approved by Engineer in charge by spray on the entire concrete surface. Provide a lean cement - sand dash coat over the same. Allow the dash coat to set for around 24 hours. Further plastering as per specifications can continue.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying chequered tiles of approved quality of size 30 centi metre x 30 centi metre, confirming to corresponding Indian Standard for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetera complete.
A) Ground Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centi metre x 30 centi metre and Confirming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying ceramic tiles having size 30 centi metre x 45 centi metre confirming to corresponding Indian Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying vitrified matt fininsh tiles having size 590 mili metre to 605 mili metre x to 605 mili metre of 8 to 10 mili metre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying vitrified matt finish tiles having size 590 mili metre to 605 mili metre x to 605 mili metre of 8 to 10 mili metre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for dado & skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing machine cut machine polished 18 mili metre to 20 mili metre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mili metre to 20 mili metre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mili metre thickness of having a strength of 400 Kilogram/Square Centi Metre of approved quality and shape on a bed of crushed sand of 25 to 30 mili metre thick including skirting joints and cleaning etcetera complete. (using 100% crushed sand)
A) Ground Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mili metre thick for door frame/ dado/ window boxing etcetera On Cement Mortor 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing Full-round Moulding ( Full Moulding ) to 18 mm to 20 mm thick granite stone including fine polishing and cleaning etc. complete.Spec. No. : As directed by Engineer-In- Charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and preparing kitchen otta up to 75 centi metre width,made up from 30 mili metre thick and 75 centi metre high vertical support for kadppa at 1 metre centre to centre of 25 mili metre thick both side polished kadappa middle shelf and bottom of 20 mili metre thick one side polished kadappa with facia patti of 20 x 50 mili metre kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etcetera complete.
A) Ground Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1 mili metre Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etcetera) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etcetera washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge.
F) Fifth Floor
Providing and fixing false ceiling of 10 to 12 mili metre thick decorative boards of fibrous plaster of paris including scaffolding if necessary all architectural work like mouldings, cornices, coves, domes, cups as per detailed drawings and three coats of spray painting to boards etcetera complete. (excluding frame work, runners and mild steel suspenders).
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 mili metre x 40 mili metre weighing 0.39 Kilogram/ metre at 60 centi metre centre to centre and fixed with ( 15 x 15 mili metre) flanges weighing 0.119 Kilogram/ metre suspended on 6 mili metre diametre mild steel rod weighing 0.22 Kilogram/ metre fixed on wall and beams including rounding of the edges with aluminium T of 50 mili metre x 40 mili metre weighing 0.39 Kilogram/ metre etcetera including all labour etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15 mili metre Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15 mili metre, suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated Galvanised Iron channel 32 with 15 mili metre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mili metre and 600 mili metre Cross Tees with a web height of 32 mili metre and a load carrying capacity of 7 Kilograms/ Square Metre with a minimum pull out strength of 100 Kilograms. The T Sections have a Galvanizing of 90 grams per Square Metre and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 mili metre x 40 mili metre x 5 mili metre with oil painting, etcetera complete
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and Fixing 30 mili metre thick BOTH SIDE PRELAMINATED SOLID PANEL Polyvenyle Chloride DOOR SHUTTER consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 mili metre for styles and 15 x15 mili metre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Polyvenyle Chloride 'C' channel made from 5 mili metre(+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30 mili metre thickness 70 mili metre width out of which 50 mili metre shall be flat and 20 mili metre shall be tapered in 45 angle on either side forming stiles ; and 5 mili metre thick ,95 mili metre wide Polyvenyle Chloride sheet out of which 75 mili metre shall be falt and 20 mili metre shall be tapered in 45 on the inner side to form top and bottom rail and 115 mili metre wide Polyvenyle Chloride sheet out of which 75 mili metre shall be falt and 20 mili metre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mili metre(+/0.25) thick Polyvenyle Chloride strip of 20 mili metre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mili metre(+/0.25) thick Polyvenyle Chloride sheet to be fitted inside the Mild Steel frame welded/ sealed to the styles and rails with 5 mili metre(+/0.25) x 30 mili metrePolyvenyle Chloride sheet beading on either side and joined together with solvent cement adhesive etcetera ,10 mili metre thickness (5 mili metre(+/0.25) x 2 nos ) 20 mili metre wide cross Polyvenyle Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos Mild Steelpowder coated but hinges of size 100 mili metre x 25 mili metre x 2 mili metre using 32 mili metre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 mili metre size steel screws including fixture fasting. Complete as per direction of engineer in charge .
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing 34 mili metre thick moulded door shutter consisting of solid core single leaf flush door of 30 mili metre thickness lipped with 15 mili metre( 5 mili metre x 3) thick x 30 mili metre width on one style and top rail and 10 mili metre(5 mili metre x 2) thick x 30 mili metre width on other style and bottom rails. The inner panels laminated with 2 mili metre thick termite proof, water proof and fire resistant moulded Polyvenyle Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mili metreplain and /or pre lam Polyvenyle Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Polyvenyle Chloride lipping etcetera as per direction of Engineer in charge and manufacturers specification and drawing etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing waterproof and termite proof flush door single leaf 35 mili metre thickness decorative types of exterior grade finished with 1.50 mili metre thick formica on both side with or without glazing or exposed faces of flush doors covered with well seasoned Teak Wood batten finished with melamine polish, flush door should be reputed brands as a like green ply/Royal with decorative lock of Indian Standard Institute mark and specification, Flush door must be recoated both side by wood guared/ATT in presence of site engineer before use all necessary beeds moulding and lipping stainless steel fixture and fastening with stainless steel handle on both side with door stoper etcetera complete ad directed by Engineer in charge. Prior approval of sample and brand by Executive Engineer in necessary before use.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mili metre with lock plate of 3.15 mili metre thickness reinforced with 35 x 35 x 5 mili metre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 mili metre and 3.15 mili metre respectively with hold fast arrangements, Mild Steel Bracket plate 300 x 300 x 3.15 mili metre minimum size and shape with square bar, suspension shaft of minimum 32 mili metre diametre, hood cover of Mild Steel sheet not less than 0.9 mili metre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etcetera complete. (Indian Standard 62481979) (With mechanical gear)
A) Ground Floor
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mili metre minimum size, crossings of Mild Steel flats of size 18 x 5 mili Metre or E section for runner of minimum 40 x 6 mili metre size for flange, Mild Steel flat for top runner of minimum size 40 x 12 mili metre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mili metre maximum spacing of vertical channels be 100 mili metre enclosed gate position and clear space of 150 mili metre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etcetera complete. (Indian Standard 105211983).
A) Ground Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick S.T. 136 with solar facor less than 0.5 and VLT in excess of 35% with all required screws and nuts etc, complete. With powder coating without box
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick S.T. 136 with solar facor less than 0.5 and VLT in excess of 35% with all required screws and nuts etc, complete. With powder coating with box
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Sliding Window- 3 Track (2 Glass shutter + 1 flymesh) of approved make with DGU, providing and fixing of Sliding Window- 3 Track (2 Glass shutter + 1 flymesh ). For details refer to Specifications. As directed by Engineer in charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75 mili metre, 3.18 mili metre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mili metre x 44.5 mili metre x 3.00 mili metre thick top rails 47.62 x 44.45 mili metre x 3.00 mili metre thick, vertical style 47.62 x 44.45 mili metre, 3.00 mili metre thick and for shutter plain glass panes 5 mili metre thick for top panels and 12 mili metre thick both side laminated phenol bonded particle board panels for bottom panels etcetera, Indian Standard Institute mark, heavy duty, Hydraulic floor spring of 150 Kilogram capacity, having heavy duty concealed lock, necessary beading, glazing clips, Polyvenyle Chloride gaskets, 250 mili metre length aluminium tower bolts, 150 mili metre diametre pad handle, etcetera as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetera complete
A) Ground Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 mili metre, 3.18 mili metre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mili metre x 44.5 mili metre x 3.00 mili metre thick top rails 47.62 x 44.45 mili metre x 3.00 mili metre thick, vertical style 47.62 x 44.45 mili metre, 3.00 mili metre thick and for shutter plain glass panes 5 mili metre thick for top panels and 12 mili metre thick both side laminated phenol bonded particle board panels for bottom panels etcetera, Indian Standard Institute mark, heavy duty, Hydraulic floor spring of 150 Kilogram capacity, having heavy duty concealed lock, necessary beading, glazing clips, Polyvenyle Chloride gaskets, 250 mili metre length tower bolts, 150 mili metre diametre pad handle, etcetera as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetera complete
A) Ground Floor
Providing and fixing in position extruded aluminium partitions having frame made out of extruded tubular section of size 65 mili metre x 40 mili metre with 12 mili metre thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 129231990, laminated on both sides, Novateak or equivalent with aluminium glazing clips of size 12 mili metre x 12 mili metre(conical) as per drawing etcetera complete.
A) Ground Floor
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing in position anodised (as per Indian Standard 1868/1982) Aluminium fixed staggered ( Z Type) Ventilator with aluminium rectangular pipe 63 mili metre x 38.10 mili metre x 1.22 mili metre at weight 0.650 Kilogram/Running Metre, Aluminium angle of size 15 mili metre x 15 mili metre x 1 mm,aluminium channel of 9 mili metre sizes, stainesless steel mosquito net of 304 Grade, 4 mili metre thick float glass per detailed drawing and as directed by Engineer in charge etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mili metre x 1.22 mili metre box type, 5 mili metre thick sheet glass louvers, of approved quality etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
a) Door Frame: Providing Frames for Lead Lined Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 140 X 70 mili metre with 45 mili metre thick two layered 3 mili metre Lead Line Sheets with 10 mili metre overlap from either side & spray quoted with 2 coats of In tumescent paint of minimum 200 micron, with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10 mili metrex4 mili metre concealed in the groove of the Frame for fire and hot and cold smoke sealing, etcetera complete as per direction of Engineer in Charge
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
b) Shutter: Providing of 57 mili metre thick asbestos free composite, 'TUFWUD' brand - 3 criteria - fire, heat and smoke check Lead Lined Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2 x 9 mili metre Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x30 mili metre with 30 mili metre thick infill of ceramic fibre (density 128 Kilograms/CMetric Tonne) vermiculite mix, 3 mili metre thick Lead Sheet on one side faced & 3 mili metre Fire retardant High Density Fibreboard, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of Intumescent paint of minimum 300 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10 mili metrex4 mili metre concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing aluminium grill diamond mesh type DG202 of 7.5 mili metre thick including fixing in position anodised aluminium frame section of 80 x 38 mili metre x 1.22 mili metre size box, cutting to the required size with all wastage, labour, lead lift etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing 40 mili metre diameter and 1.5 mili metre thick Stainless steel hand railing in Stainless Steel 304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etcetera complete
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing Stainless steel Railing of 304 grade with 50 mm dia Post at 1.00 Mtr center to center, and 25 mm dia hollow pipe in 4 (four) rows horizontally on other side only, includes pipe of approved quality as per detailed drawing including, buffing, fabricating, fixture and fastening, finishing the corner smooth and necessary welding etc complete as directed by Engineer in charge, as per drawing attached.As directed by Engineer in charge. page no. 79 DSR I.No. 324
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing in position extruded coloured aluminium composite fixed glass panels double glass unit having frame made out of extruded tubular section of size 34 millimetre x 42 millimetre (or as required size in proportionate weight) of average thickness 2 millimetre and weight 0.726 kilogram/metre (or as required) mechanically assembled at corners with glazing, beeding of average 0.26 kilogram/metre or required weight including 5.50 millimetre thick clear glass and 6 millimetre green colrex glass with U section of aluminium for 3.18 millimetre thick and weight of 0.38 kilogram/metre with neoprene (rubber) gasket etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing in position structural glazing faces of building made out of colour anodized alluminium frame curtain wall of 63 mm x 57 mm x 2.2 mm thick including toughened reflective glass 5mm thick of panel 600 x 900 x 1200 mm size. The item shall include toughened coloured reflective glass 5 mm thick water proofing silicon sealent G.E. winsil 10/20 G.E. ultra glaze including alluminium fixtures S3 screws and nut bolt, scaffolding MS. angle cleats & frame of 65 mm x 65 mm x 6mm & scaffolding etc. complete minimum 20% area of structural glazing shall be openable for openable panels aluminium hinges. wind stays and locking arrangements & alluminium angels or tee section of required size as directed by engineer incharge.
A) Ground Floor
B) First Floor
Providing and fixing 6.00 mm polycorbonate multiwall ultra violet protected sheet for roofing over fabricated steel structure as per detailed design, perforated CRC steel along perimeter including fixing the polycarbonate sheet with aluminium angle and flat anodised and dyed as per approved shade including all water proofing materials, nut bolts, hardware, labour and safty grill of 16 mm dia. M.S. bars fixed with help of M.S. flat and angles over the opning complete Incuding allscafolding etc. as per required.
F) Fifth Floor
Providing expansion joints in reinforced cement concrete framed structure (interior columns) with plain premoulded filler with Confirming to Indian Standard 1838,1961, 25 mili metre thick with 75 mili metre wide and 1 mili metre thick stainless steel plate finishing etcetera complete as directed
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing expansion joints in R.C.C. framed structure (exterior column) with plain premoulded filler 25 mm thick with 75 mm wide and 1 mm thick stainless steel plate and finishing etc. complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing expansion joints in R.C.C. framed structure (at floor level) with plain premoulded filler 25 mm thick with 75 mm wide and 1 mm thick stainless steel plat and finishing etc. complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
Providing expansion joints in R.C.C. framed structure (at Terrace level) with premoulded filler 25 mm thick with 40 mm wide and 1 mm thick stainless steel plate as required, bitumen poured filler and finishing etc. complete as directed.
F) Fifth Floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 mili metre thick Mild Steel sheet fan hook box of size 180x100 mili metre with required depth with holes or notches as required, bottom and top sides of 1.6 mili metreS. sheet fixed with 3.5 mili metre diametre round headed screws together with 12 mili metre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. complete. Spec. No. : As directed by Engineer in charge.
Dismantling the R.C.C. work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. Spec. No. : As directed by Engineer in charge.
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast Reinforced Cement Concrete rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated Polyvenyle Chloride casing pipe wrapped around with netlon mesh including 300 mili metre thick sidefilling around outside of Reinforced Cement Concrete rings (annular space) with 40 mili metre size boulders including filling of recharge pit up to 0.5m depth with 25-75 mili metre clean washed gravels from bottom up followed by 0.5m depth of 10-25 mili metre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etcetera) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etcetera) media layer including covering with Reinforced Cement Concrete slab, manhole frame & cover, Polyvenyle Chloride rungs, Polyvenyle Chloride end-caps, fittings etcetera including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Boring/drilling bore well of 300 mili metre diametre for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized Polyvenyle Chloride medium well-casing pipe of 150 mili metre dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etcetera all complete, for all depths, as per the direction of Engineer in charge.
Providing and fixing screw down 15 mili metre diametre wheeled stop tap of brass including necessary sockets/union nut complete
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32 mili metre diameter Poly Venyle Chloride flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etcetera complete as directed by Engineer in charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and constructing Brick Masonry Inspection Chamber 90 centi metre x 45 centi metre x 90 centi metre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete Cover medium duty 140 Kilogram with frame etcetera complete.
Providing soak pit of size 120 centi metre x 120 centi metre x 120 centi metre including excavating and filling with brick-bats.
Providing and fixing 15 centi metre x 10 centi metre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and fixing in position Unplastisized Polyvenyle Chloride ultra violet stabilized 110 mili metre outer diameter cowl dome confirming to Indian Standard-4985 including making joints with solvent cement etcetera complete
F) Fifth Floor
Providing and fixing 450 mili metre x 550 mili metre size superior type Belgium mirror with 16 mili metre diametre nickel plated towel rod etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing 75 mili metre diametre stabiliser pipe/ Poly Venyle Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetera complete
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing 100 mili metre diametre stabiliser pipe/ Poly Venyle Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing, laying and fixing Poly Venyle Chloride pipe of 110 mili metre diametre with fittings such as bends, tees, reducers, clamps, etcetera including necessary excavation, trench filling etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters
F) Fifth Floor
Providing and fixing on walls/ ceiling/ floor 15 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing on walls/ ceiling/ floor 25 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing on walls/ ceiling/ floor 32 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing on walls/ ceiling/ floor 50 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete.
F) Fifth Floor
Providing and laying in trenches 50 mili metre dai. CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A) Ground Floor
Providing and laying in trenches 25 mili metredai. CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A) Ground Floor
Providing and fixing 10 centi metre Polyvenyle Chloride nahani trap with grating etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing C.P. wall mixer with provision for overhead shower with 115 mili metre long bend pipe and wall flange of approved make including necessary sockets/union nut etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etcetera complete."
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing C.P. Towel ring square jaquar make continental of standard category like Jaquar make (standard series) or equivalent good quality, including fixing at desired location, including required no. of screws, all materilas, labour, lead, lift, all taxes, finishing, cleaning etc. complete. As directed by Engineer in Charge
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing 100 mili metre diametre chromium plated brass showers rose to 15 mili metre diametre supply pipe including necessary bend and socket complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing white european type wall-hung pan, of size 350 mili metre x 355 mili metre x 570 mili metre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung Water Closet, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 mili metre diametre C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing Orissa Pan of size 580x445x260 mili metre with approved make flush valve including trap, Cast Iron soil and vent pipe upto outside face of wall including 100 mili metre diametre Cast Iron plug, bend and necessary pipe connection, etcetera complete. As directed by Engineer in charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing white glazed earthenware Wash Hand Basin of 45 centi metre x 30 centi metre size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including Polyvenyle Chloride waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing Table top white wash basin of size 120x635x405 mili metre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including Stainless Steel bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing Poly Venyle Chloride Rain water pipes of 110 mili metre outer diameter and having wall thickness of 2.2 to 2.7 mili metre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyle Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 mili metre to 40 mili metre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Venyle Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 mili metre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mili metre thick fixed on Black Kadappa Framework, etcetera Complete as directed by Engineer in charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 mili metre incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing C.P. Toilet rack 24" with lower hanger jaquar made continental of standard category like Jaquar make (standard series) or equivalent good quality, including fixing at desired location, including required no. of screws, all materilas, labour, lead, lift, all taxes, finishing, cleaning etc. complete. As directed by Engineer in Charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing 15 mili metre diametre Polyvenyle Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etcetera complete
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing wind operated stainless steel ventilater system for varius sizes etc. complete.
Providing and fixing C.P. soap dish (polyurethane) jaquar make continental of standard category like Jaquar make (standard series) or equivalent good quality, including fixing at desired location, including required no. of screws, all materials, labour, lead, lift all taxes, finishing, cleaning etc. complete. As directed by Engineer in Charge.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Providing and fixing screw down for 25 mili metre diametre wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 40 mili metre diametre wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 50 mili metre diametre wheeled stop tap of brass including necessary sockets/ union nut complete.
Providing and fixing black kadappa stone as shelves 25 mili metre thick machine polished, extending the polish upto 20 centi metre width on lowerside, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etcetera complete.
A) Ground Floor
B) First Floor
C) Second Floor
D) Third Floor
E) Fourth Floor
F) Fifth Floor
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 Metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift from 1.50 metre to 3.0 metre) By Manual Means
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetera including bailing out water, Steel centering formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etcetera complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
Providing and fixing mild steel grill work for windows, ventilators etcetera 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etcetera as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etcetera and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etcetera complete.
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
Spreading hard murum/ soft murum/ gravel or kankar for side width complete
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etcetera complete.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means -Grading I (Using Screening Type B (11.2 mm) Aggregate)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate)
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate (VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mili metre,, cement content not to be less than 150 Kilogram/ Cubic Metre, Optimum Moisture Content (OMC)to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etcetera complete.
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a Tilting type Concrete Mixer as per approved mix design, admixtures, spreading, laying compacting and finished in a continuous operation without paver machine, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.
Excavation for foundation in earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed etcetera complete. (By Manaual Means) a) Upto 1.50 metre lift Normal Rate
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centi metre to 20 centi metre thick including hand packing and compacting etcetera complete.
Providing and laying in situ / ready mix cement concrete of M-10 proportion with trap/ granite/ quartzite/ gneiss metal in foundation including necessary form work, compacting and curing etcetera complete. (with reversible drum type mixer with SCADA with fine aggregates of required specifications (Natural sand / VSI sand finely washed etcetera )
Providing cast in situ / ready mix M-20 grade cement concrete for head walls of Cross Drainage Work / retaining walls etcetera including necessary form work, compaction, finishing and curing etcetera complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA
Providing and laying cement concrete pipe of IS 458:2003 NP-3 class of 900 mili metre diameter in proper line, level and slope etcetera complete.
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & laying HMS PVC conduit 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 1x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 1x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. Note: Add Rs 57/- for additional two module box with double mounting plate if required.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting 16 to 32 A DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected.
Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Providing & erecting 4 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB Rate 4552+20% of 4552=5462.40
Supplying and erecting submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s.A.C. supply, having delivery head from 36 to 18 m and discharge from 400 to 1000 Itrs. per minute (Max efficiency at 29 m head & 680 Itr discharge) & pipe of Suction 75 mm/Delivery 65 mmdiameter erected with necessary H type clamps as per specification no. WP-OSP
Supplying and erecting square / round shaped CRCA /die-cast aluminium powder coated housing LED panel ( slim edge-lit) light suitable for 13W to18W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting bulkhead fitting suitable for upto LED upto 12W fixed on wall. As per specification no. FG-IDF/BHF
Supplying and erecting LED street light fitting suitable above 26W to 36W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG-ODF/FLS2.
Supplying and erecting street light Wall bracket made from 25 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB
Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22/E-27 base.
Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22/E-27 base.
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting storage type horizontal / vertical water heater 15 litres capacity with BEE 5 star rating high impact resistance engineering plastic body on wall / loft complete duly tested and marking sr. no. and date of erection. specification no. AP-WH/STWH
Supplying and erecting ISI mark midget type 3.0 Ltr instant type water heater of ABS plastic body 3 kW, heating element 230/250 Volts 50 cycle AC supply with inlet and outlet, thermostatic control and thermal cutoff with 3 core PVC flexible wire leads complete duly tested and marking sr. no. and date of erection.
Providing fibre reinforced pvc flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1set of 2 nos) complete.
Supplying, erecting, testing and commissioning self-contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres/hr and storage capacity 80 litres with partially stainless steel body complete. specification no. APWCR/ WC
Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water 7 to 8 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply.
Supplying, installing, testing and commissioning of 1400 VA to 1600 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. AP-INV (Without batteries)
Supplying & erecting on line UPS pure sine wave of 2 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS
Supplying and erecting 12 V/150Ah tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete
Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
Supplying and erecting four pole metal clad ON LOAD change over switch 415V, 40A erected on angle iron / GI frame complete.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 ways, on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting and marking enclosure single pole and neutral distribution board (SPNDB) one way for SPMCB 1 no on iron/ GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete.
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles) on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) , on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB of 200A,415V capacity with short circuit rating 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB Rate 9054+20% of 9054=10864.80
Providing & erecting 4 Pole MCCB of 315/400A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB Rate 16330+20% of 16330=19596
Providing & erecting 4 Pole MCCB of 800A, 415V capacity with short circuit rating 50 kA ,(Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB Rate 31716+20%of 31716=38059.20
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 2 ways four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB.(Excluding MCCB'S)
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 6 ways four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S) (Panel no 2)
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 8 ways Four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S)
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 400A, 8 ways four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S) (Panel no 1)
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 250A incoming and 2 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cable way and DB complete.
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete.
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete.
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 250A incoming and 12 way outgoing or 400A incoming and 6/8 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete.
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided MS box for 400A complete.
Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 4 pole above 630A upto 800A MCCB complete. (Set of 8)
Supplying and erecting SS enclosure for MCCB suitable for 125A to 200A MCCB complete.
Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 4 pole upto 100A MCCB complete. (Set of 8)
Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 4 pole above 100A upto 250A MCCB complete. (Set of 8)
Supplying and erecting GI sheet 1.6 mm (16 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 1100 V. 3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, a.c. Submersible/centrifugal pump set for 7.5 to 10 HP consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc
Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Making trench of suitable width and depth in soft soil for laying provided LT cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. CW-EXNCTR
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying and erecting ISI mark GI pipe 65 mm. dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting 65 mm dia. gun metal sluice valve at position with necessary materials complete.
Supplying and erecting non return valve 65 mm dia in position made of gun metal complete.
Providing ,Erecting ,Commisioning of LED Surgical Lights of Modelno Intensity: 80,000 + 80,000 Lux ±10% Size of Light Field: 12-30 cm Color Temperature: 4000-5000 K Color Rendering Index: 93 RA LED Life: >50000 Hrs Number of LED: 57 + 57 Diameter of Light: 500mm x 2 Brightness Control: Capacitive Touch Panel Power Supply: 220V/50Hz AC Color of LED: White & Yellow (Double Colour) Focusing: Adjustable TMI HEX CT 3+3
Providing ,Erecting ,Commisioning of LED Surgical Lights of Modelno Intensity: 140000 Lux ±10% Size of Light Field: 12-30 cm Color Temperature: 4000-5000 K Color Rendering Index: 93 RA LED Life: >50000 Hrs Number of LED: 95 Diameter of Light: 500mm Brightness Control: Capacitive Touch Panel Power Supply: 220V/50Hz AC Color of LED: White & Yellow (Double Colour) Focusing: Adjustable TMI HEX CT 5
Providing ,Erecting ,Commisioning of LED Surgical Lights of Modelno. Intensity: 90,000 Lux ±10% Size of Light Field: 12-30 cm Color Temperature: 4000-5000 K Color Rendering Index: 93 RA LED Life: >50000 Hrs Number of LED: 63 Diameter of Light: 500mm Brightness Control: Capacitive Touch Panel Power Supply: 220V/50Hz AC Color of LED: White & Yellow (Double Colour) Focusing: Adjustable
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.
Supplying, erecting & terminating XLPE armoured cable 3 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 200 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 200 mm dia. complete as per specification no. FF-VL/BFV
Supplying and erecting cast iron double flange NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 200 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting 100 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying & erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ
Supplying, installing, testing and commissioning FR, XLPE armoured cable 8 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning remote response indicators complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main single stage pump, of 2400 LPM at 76 m head centrifugal type, 75 HP (55 kW) 3 phase, 415 volt, 50Hz or of suitable HP complete as per specification no. FF-MFP/SSC
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 105 m head 20 HP (15 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP .
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of booster pump of 450 LPM at 35 m head 7.5 HP (5.5 KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/BP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and installing G.I.pipe above ground of C class ERW of size 80/75 mm dia with necessary fittings as per specification No. FF-PP
Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
Supplying & installing One piece moulded HDP / Fibre water tank.for -ve suction only, having capacity 1000 ltrs.fitted with necessary accessories complete as per specification No.FF-FFA/PT
Supplying, erecting, testing and commissioning of 15 mm (½") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 40 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 32 mm dia with necessary fittings complete as per specification no. FF-PP
Supply & Istallating flexible drop (Sprinkler Dropper) with stainless steel braided or unbraided corrugated hose,sprinkler reducer, light weight bracket,caring bar etc with necesaary materail
Supplying & installing gun metal ball valve of size 50 mm
Supplying & erecting flow switch of size 150 mm dia complete as per specification no. FF-VL/GV
Supply & Istallating of Sprinkler Alarm 150 mm Valve with water motor gong bell and trims as required pressure gauges, drain valves,ball valves, check valves, strainers etc.Alarm valve shall be UL Listed.
Diesel driven main fire pump suitable. 2280 LPM @ 70 mtr horz. end suction back pull out pump model in Bronze fitted construction ( Code 02 ) running at 1800 rpm bare shaft along with accessories like fabricated MS base frame & coupled to radiator cooled engine along with silencer , 12 V starting arrangement & other standard accessories.
Supply, Installation, Testing and Commissioning of Addressable manual call point complet address switch with necessary materail as per specifications
Supply, Installation, Testing and Commissioning of Addressable Hooter complete with wall mounting arrangement with necessary materail as per specification
Supply, Installation, Testing and Commissioning of Analogue addresable photoelectric type smoke detector with mounting base, LED, Address switch complete as per specifications.
Supply, Installation, Testing and Commissioning of Isolator Module complet address switch with necessary materail as per specifications
Supply, installation, testing & commissioning of 4 loop fire alarm panel 159 intelligent Opal detectors per loop,159 modules (AV, MCP, input/output interface modules) per loop, 2 programmable outputs – monitored for open and short circuits,2 programmable inputs, 4 soft keys programmable to the needs of the user Advanced Cause and Effect programming, Cable entry through punched holes - no need to knock out blanks,Custom logo on quiescent screen Day/Night mode configurable for site specific requirements,Class change facilities, Loop auto-learn function,Backlit buttons and on screen help for user guidance, CPD approved by LPCB (BRE),6 line text repeater for event control.
Supply, installation, testing & commissioning Repeater Panel. Silence, Mute, Reset, Accept, Evacuate and Test Controls. For use with DX control panels only use a 24 Vdc supply. For use with ZX control panels use a 24 Vdc supply and an RS485 card.
Ajaydeep Infracon Pvt Ltd
Harsh Constructions Pvt Ltd
Shubham EPC Private Limited
K H CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf