Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | L1 | Accepted-AOC Being l1 Bidder | |
| 2 | L2₹8.0 L+₹1,909 (0.24%)Rejected-AOC SAMANNWYA PALLY SURI BIRBHUM PIN 731101 | SURI | BIRBHUM | WEST BENGAL | 731101 | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹8.0 L+₹2,185 (0.28%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹15,927
Closing Date
24 Feb 2020, 5:00 pmClosed
Executive Engineer,PWD,Birbhum Electrical Division
Laldighipara, P.O. Suri Dist. Birbhum. Pin. 731101 Near Suri Sadar Hospital
Installation of proper illumination system for both inner side and outer side for newly constructed gangway of Rampurhat Govt. Medical College and Hospital, Rampurhat, Birbhum Electrical.
2020_WBPWD_272190_1
BIRED/45/e-Q (1st call) of 2019-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Gangway, Rampurhat
Please refer Tender documents.
8 documents required · 8 mandatory
₹15,927
12 Mar 2020
14 Feb 2020
27 Feb 2020
14 Feb 2020
24 Feb 2020
14 Feb 2020
Amount
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Fort Gloster]
4 Core 10 Sq. mm [ NS ]
3 Core 10 Sq. mm [ NS ]
4core70sqmm [ NS ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Laying of cable upto 35 sqmm in underground trench as per GS for the following numbers of Cables.
1 No Cable [ 1(a)/ F- 2 ]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
1 No Cable [2(b)/F-1 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4 Core 10 Sq. mm [7(a)/F4 & 8(b) /F5]
3Core 10 Sq. mm [7(b)/F4 & 8(b) /F5]
4 Core 70 Sq. mm [7(a)/F4 & 8(b) /F5]
4 Core 185 Sq. mm [7(a)/F4 & 8(b) /F5]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
40mm dia [11(c)/F-6]
Fixing only single/twin fluorescent light fitting fixed with 2 nos “L” type MS clamp by welding, in the metal structure.
Supply of 4 Ft. 20 Watt single/twin LED light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips)
a. Single LED fittings (Philips cat No TMC 501 1XT-LED 22W P3241) with 1no. Essential LED tube 1200mm 20W865 T8 IND I – 2100lm (Polycarbonate body)
a. Double LED fittings (Philips cat No TMC 501 2XT-LED 22W P3242) with 2nos Essential LED tube 1200mm 20W865 T8 IND I – 2100lm (Polycarbonate body)
Supply & Fixing of 90W LED street light fittings complete with all accessories. [CROMPTON, Cat No. LSTN-120-CDL-A] [NS]
Supplying & Fixing bulk head light fitting (Philips Make) [WT202W LED6S NW PSU S2 PC]
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properlyProviding CC (6:3:1) base block (around the pole) dimension 0.6x0.6x0.76 mt. above ground level, incl. S & F 25cmx25cmx10cm CI Loop box.
Supply of 7 mtrs long GI octagonal pole with GI arm bracket as per dimension top dia 70 mm bottom dia 130 mm section I length 700 mm thick 3mm blank plate (225*225*6)mm PCD 225 mm including foundation accesorries(Makr-Utkarsh/Bansal/skipper/c.g.)
Design, Manufacture, testing, supply and commissioning of the following outdoor type Distribution Feeder Pillar box conforming to Indian Standard IS : 5039-1969 with latest amendments Suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. Supply and shall be suitable for short circuit fault of 31 MVA at 415 Volt. The dimension of the body is --1400 (H) X 750 (W) X 400 (D) mm.The body will be fabricated with 5mm thick MS plate, MS angle ( 50X50X6) & MS Flat ( 50X6 ).The Base Plate will be made by 10 mm thick MS Plate.The top of the box will be fitted with a sloping canopy made out of 5 mm thick sheet steel.It will have a set of water proof double hinged door at the front with suitable locking arrangement ( Godrej Type ) and provision for manual locking arrangement.A hylam sheet of 10mm thick of suitable size will be fitted.Adequate ventilation by means of louvers with wire mesh shall be provided on both sides and at the top and bottom of both sides of LT pillars.The inside will be painted by 1 coat of Redled / zinc chromate and the outside will be painted by 2 coats of synthetic enamel paint over 1 coat of Redled / zinc chromate.The Enclosure shall provide Degree of protection IP -43 in accordance with IS : 2147 -1962 with its latest ammendment.The Feeder box will contain the following switches and accessories .4 way PBDB with 1 nos of 63 A MCB Isolator and 12 nos of 40 A MCB (Legrand)[Cat No-- 14/D-10,6/D-5 & 7/D-6].Electromechanical Timer with battery backup - 2 No. (Make - ABB/ Havells/ L&T).415V, 63A, 4 Pole AC operated Power Contactor - 1 No. (Make - ABB/ Havells/ L&TInstallation of the above pillar box with brick foundation of size as per direction by EIC with hard jhama cement morter soaling at bottom 300mm below GL & 450mm above GL neatly plastered & neat cemented finish incl. painting by best quality 2 coats of synthetic enamel paint over 1 coat of RO primer as per direction of the EIC.
Supplying & Fixing sheet metal loop box (16 SWG) of the following sizes(in mm ) in the metal structure by welding, incl. S & F of 3 nos copper bar fixed on hard rubber chair.
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. Incl Supply & Fixing of polythene pipe
3 x (1.5 sqmm)
2 x 2.5sq mm + 1 x 1.5sq mm
Charges for shifting of 50KVA DG set by hiring Hydra from one place to other. ( 700 mtr )
Installation, Testing and Commissioning of shifted 50 KVA DG set incl serving and inter connection incl supply & pouring fuel.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe[ 2(b)/G-1 ]
Connecting the equipments body to earth busbar including S & F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [ 5(d)/G-3 ]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required4(a)/G-2 ]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil [ 1(b)/G-1 ]
Supply of Hot Dipped Galvanised(Z+) Wiremesh cable Tray with wire dia from 3.9 mm to 5.9 mm for depth 30mm & width 100mm of trays including supports. It shall be manufactured with a longitudinal 'T'welded safety edge. Trays shall be constructed with 50 mm / 100 mm mesh configuration. Accessories for coupling and making 'T's and bends CE25/CE30 screw based system combination must be used and mounting accessories are required of same finish of same manufacturer as per the site requirement (celing/wall mounted). Trays should comply standard EN ISO14 61: at least 550 hrs. of SST. The deflection of cable tray must be within 1/200-th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire cable trays must be designed with an optimum span of 1.5 mtr., taking into account the maximum load carring capacity as authorised by the manufacturer. Assembly with fire ressitant properties must have an E30/E90 certificate. The loading capacities of the brackets and the hanger torques must be tested in accordance with the standard IEC 61537. No hot work for trays is allowed at site. MAKE: LEGRAND (CABLOFIL)/ COPE/ LEVITON/ PANDUIT
Terms and conditions:- 1. Rates should be quoted in words as well as in figures Inclusive of all taxes, duties and delivery charges. 2. Manufacturer’s Test Certificate should be produced During delivery/ Commissioning. 3. All materials, equipments and accessories for the Genset must be as per the latest relevant I.S.S. 4. All equipments must be warranted for a period of 12(Twelve) months from the date of commissioning. 5. Price variation clause will not be accepted. 6. Terms of payment:- as per PWD norms. . 7. Conditional offer specially in deviation to the above clauses is liable to cancellation.
NOTE: 1.The Agency must procure the materials from the manufacture /OEM or from their authorised sales channel so that the standard warranty/support of the manufacture /OEM becomes applicable to the products to be delivered and installed by them 2.Documents that authenticates such procurement from the manufacture /OEM or from their authorised sales channel and standard warranty/support should be sent from the e-mail of the manufacture /OEM /authorised sales channel to the e mail of Engineer -in charge and hard copy of it to be submitted during execution of work/submission of Bill. 3. If any refurbished material is supplied and installed , Panel action will be will be takena as per existing rules.
MS K. K. GHOSH and CO.
RIK ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .