Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.9 L+₹23,757.50 (1.10%)Rejected-Finance | L2 | Rejected-Finance OTHER THEN LOWEST BIDDER | |
| 3 | L3₹27.5 L+₹5.8 L (26.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THEN LOWEST BIDDER | |
| 4 | L4₹29.3 L+₹7.6 L (35.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THEN LOWEST BIDDER | |
| 5 | L5₹31.0 L+₹9.3 L (42.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THEN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | KRISHNA ENGINEERING ENTERPRISES L4 | VIKAS ENTERPRISES L3 | narayan construction L2 | NATIONAL TRADING COMPANY L1 | M/S BHATT TRADERS L6 | MEELU ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | B/R PORTIONS :- Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed. | 8 | Cum | 100 ₹800 | 100 ₹800 | 5 ₹40 Lowest | 100 ₹800 | 20 ₹160 | 5 ₹40 Lowest |
| 2.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tile to store and rubbish off the premises complete all as specified and directed. | 225 | Sqm | 40 ₹9,000 | 10 ₹2,250 | 5 ₹1,125 Lowest | 5 ₹1,125 Lowest | 20 ₹4,500 | 5 ₹1,125 Lowest |
| 3.00 | Dismantling wall/ceiling board (fibre, pulp, insulation, etc) or insulation board, slabs/ blankets, of any thickness, including cover fillets complete all as specified and directed. | 150 | Sqm | 50 ₹7,500 | 10 ₹1,500 | 5 ₹750 | 5 ₹750 | 20 ₹3,000 | 1 ₹150 Lowest |
| 4.00 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed | 225 | Sqm | 15 ₹3,375 | 10 ₹2,250 | 1 ₹225 Lowest | 10 ₹2,250 | 20 ₹4,500 | 1 ₹225 Lowest |
| 5.00 | 4mm thick E-board (Classic) including fixing of frame work made of special section MS galvanised sheet with zink coating cellular intro painting and consisting of angle cleats of size 25mm wide 1.6mm thick with flag fixing to the ceiling with dash fastner 12.5mm x 40mm long or with 2mm dia GI wire or fixed with bolt in GI channel main 35x25x0.5mm thick and cross runner 25x25x0.5mm for fixing E-board of size 600x600x4mm thick including fixing of E-board with ceiling section and parimeter of channel 25x25x1mm thick,27mm high flange of 20mm to 30mm long extra including appying two coat of distemper oil emulsion, complete all as specified and directed. | 150 | Sqm | 800 ₹1,20,000 | 800 ₹1,20,000 | 700 ₹1,05,000 | 480 ₹72,000 Lowest | 1,200 ₹1,80,000 | 900 ₹1,35,000 |
| 6.00 | PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 50mm thick as in plinth protection finished fair & even laid in alternate bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed. | 40 | Sqm | 250 ₹10,000 | 280 ₹11,200 | 180 ₹7,200 | 160 ₹6,400 | 50 ₹2,000 Lowest | 333 ₹13,320 |
| 7.00 | Chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with grey cement mixed with pigments, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed | 50 | Sqm | 950 ₹47,500 | 850 ₹42,500 | 900 ₹45,000 | 800 ₹40,000 | 500 ₹25,000 Lowest | 1,050 ₹52,500 |
| 8.00 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed. | 50 | Sqm | 200 ₹10,000 | 300 ₹15,000 | 200 ₹10,000 | 120 ₹6,000 | 50 ₹2,500 Lowest | 400 ₹20,000 |
| 9.00 | Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles, over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. | 200 | Sqm | 1,000 ₹2,00,000 | 980 ₹1,96,000 | 800 ₹1,60,000 | 800 ₹1,60,000 | 670 ₹1,34,000 Lowest | 999 ₹1,99,800 |
| 10.00 | Non skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exc 0.11Sqm but n exc. 0.18Sqm in vertical surfaces such as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles,fixed over and including 10mm thick plaster in CM (1:4), complete all as specified and directed. | 25 | Sqm | 1,000 ₹25,000 | 980 ₹24,500 | 800 ₹20,000 | 820 ₹20,500 | 400 ₹10,000 Lowest | 999 ₹24,975 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Jan 2026, 6:00 pmClosed
GE 881 EWS, C/O 56 APO
GE 881 EWS, C/O 56 APO
REPAIR TO FLOORING, WALL PANELING, ROOF SHEET, WINDOW AT MENDHAR BG UNDER AGE B/R-I AND REPAIR / MAINT OF LT OVER HEAD CONDUCTOR, UNDER GROUND CABLE, LT PANEL AND ALLIED ACCESSORIES UNDER AOR OF AGE B/R-II
2025_MES_746312_1
GE/PNH-89/2025-26
Open Tender
Civil Works - Others
Item Rate
120 days
GE 881 EWS, C/O 56 APO
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE 881 EWS
₹80,000
Yes
25 Feb 2026
27 Dec 2025
22 Jan 2026
27 Dec 2025
19 Jan 2026
11 Jan 2026
B/R PORTIONS :- Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tile to store and rubbish off the premises complete all as specified and directed.
Dismantling wall/ceiling board (fibre, pulp, insulation, etc) or insulation board, slabs/ blankets, of any thickness, including cover fillets complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed
4mm thick E-board (Classic) including fixing of frame work made of special section MS galvanised sheet with zink coating cellular intro painting and consisting of angle cleats of size 25mm wide 1.6mm thick with flag fixing to the ceiling with dash fastner 12.5mm x 40mm long or with 2mm dia GI wire or fixed with bolt in GI channel main 35x25x0.5mm thick and cross runner 25x25x0.5mm for fixing E-board of size 600x600x4mm thick including fixing of E-board with ceiling section and parimeter of channel 25x25x1mm thick,27mm high flange of 20mm to 30mm long extra including appying two coat of distemper oil emulsion, complete all as specified and directed.
PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 50mm thick as in plinth protection finished fair & even laid in alternate bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
Chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with grey cement mixed with pigments, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed
75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed.
Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles, over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
Non skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exc 0.11Sqm but n exc. 0.18Sqm in vertical surfaces such as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles,fixed over and including 10mm thick plaster in CM (1:4), complete all as specified and directed.
15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces, chajja, suspended work etc & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
10mm thick rendering in CM 1:6 on other than fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement, complete all as specified.
Applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces of wall complete all as specified and directed.
Preparation of new plastered or unplastered surface of wall including cornices ,pilaster etc. and applying two coats of oil bound distemper over and including chalk whiting primer, complete as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
Dismantling mild steel work of any description complete all as specified and directed.
Dismantling of timber scantling 40sqcm and over in section, as in any position, complete all as specified and directed.
Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws as specified.
Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleatsetc Fe 410W(Gde E-250), quality 'A' complete all as specified and directed.
Mild steel work as in wind ties for roof including securing bolts, including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-250 Gde E-165 all as specified and directed.
2nd class hard wood in scantling, clean sawn fixed in repairs in any position to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store, complete all as specified and directed.
Taking down shutters of any description not exceeding 1sqm each, complete all as specified and directed
Taking down chowkats or frames n exc 1.50 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkhats or frames with shutters exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutters from frame) complete all as specified and directed.
1st class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
35mm thick 2nd class hardwood plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered paticle board medium density, wood patilcle board with commercial face veneers complete all as specified and directed.
30mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered or rounded, mitred and rebated shash bars, any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters , supplied & fitted to chowkats as specified and directed.
Mild steel butt hinges, medium weight, cold rolled,100mm long, complete all as specified and directed.
Mild steel butt hinges, medium weight, cold rolled,75mm long, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section of size 100mm and fixed, complete all as specified and directed.
Aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed.
Aluminium alloy handles, cast type, anodised of size 100mm and fixed, complete all as specified and directed.
250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.
Preparation of new or previously untreated surfaces of wood over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Figured glass pin headed type, 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed.
Preparation of new or previously untreated steel or iron surfaces not exceeding 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Plain cement Concrete 1:3:6 type-C1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts ,plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed.
Preparation of old plastered or unplastered wall surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots etc and applying one coat of white wash on walls including cornices, pilasters etc, complete all as specified and directed.
Preparation of old plastered or unplastered wall surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots etc and applying one coat of cement base paint on walls and AC sheet roof surfaces (any tint) , complete all as specified and directed.
E/M Portion:- Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc for shafts, wells,cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in hard / dense soil, complete all as specified.
Excavation in trenches not exceeding 1.50m wide and exceeding 1.50m in depth for foundation etc for shafts, wells,cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and exceeding 1.5m depth and getting out in hard / dense soil, complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed.
DWC HDPE pipe for protection of power cable (orange in colour) of size 100 mm dia complete with fittings and including cutting, jointing and clamping all as specified and directed.
DWC HDPE pipe for protection of power cable (orange in colour) of size 80 mm dia complete with fittings and including cutting, jointing and clamping all as specified and directed.
DWC HDPE pipe for protection of power cable (orange in colour) of size 80 mm dia complete with fittings and including cutting, jointing and clamping all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 3.5 core, cross sectional area 185 Sqmm, all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 3.5 core, cross sectional area 120 Sqmm, all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 3.5 core, cross sectional area 95 Sqmm, all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 3.5 core, cross sectional area 70 Sqmm, all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 3.5 core, cross sectional area 50 Sqmm, all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 3.5 core, cross sectional area 35 Sqmm, all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 4 core, cross sectional area 25 Sqmm, all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 4 core, cross sectional area 16 Sqmm, all as specified and directed.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, 2 core, cross sectional area 10 Sqmm, all as specified and directed.
Steel tubular poles, swaged type, 410-SP-31, 9m long with 300x300x6mm thick MS base plate continuously welded to pole with MS sheet 2mm thick plug welded at top, bolts, nuts and screws all as specified including two coats of black bituminous paint internally throughout and externally for embedded portion and two coats of aluminium paint over a coat of red oxide primer on exposed surfaces including painting up to 1.5 mtr height from ground level or above coping with two coats of synthetic enamel paint in 30cm strip, alternate black & yellow starting with black at ground level, including taking down unsv PCC poles, complete all as specified and directed.
Dismantling cross arms of MS channel or angle section etc complete and setting aside for reuse all as specified and directed.
Cross arms, bracing, supports clamps and back plates, fabricated from structural steel sections incl nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed incl one primer, one under coat and one finishing coat of aluminium paint with and including preparation of steel surfaces, complete all as specified and directed
Pin type porcelain vitreous white brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade all as specified and directed.
Shackle type porcelain, vitreous white, brown or green insulator for working pressure 1100 volts grade, 115mm dia, 100mm height including galvanized mild steel straps of 31x3mm size, 12mm dia insulator bolts, washers and nuts complete all as specified.
Stay assembly for electric pole complete with accessories as shown in electrical plate No. 1 of SSR Pt-I and drg using stay rod of 16mm dia fixed in replacement, complete all as specified. Note : Excavation,earthwork, PCC and loop type insulator shall be measured and paid separately.
Supply and replacement in repair of galvanised stay stand, size 7/3.15 mm for connecting stay assembly with MS clamp on poles complete all as specified and directed.
Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 90x140mm, clearance of hole 25.5mm complete all as specified and directed.
Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed.
Material and labour in replacement of ACSR conductor of adequate size and type including stretching, fixing and binding to insulator on OH/ HT/LT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified and directed. Note:- The weight of the conductor shall be determined as stipulated in Preamble (b) on page 384 of SSR-2010 Part II
Cutting /Trimming/ Chopping of tree trenches along the overhead lines upto 3 m from electric lines clearance on both sides of overhead lines and disposing off the cut tree/ branches site to a distance not exc. 50 m and clearing the site as directed by Engr-in-Charge. Note:- Contractor is supposed to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6" dia at his own arrangement and cost.
Re-streching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire complete all as specified and directed. (Old conductor shall be reused where required for repairing broken length of conductor as directed by E-in-C) Note:- Five line together will be measured as one span from pole to pole.
Painting to poles including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height , spray painting with two coat of synthetic enamel paint of 1st quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching rubbing complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft / loose soil, P.C.C 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer,charcoal and testing on completion including dismantling unserviceable earthing complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600x 600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron earth lead strip 32x6mm by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 40mm bore including GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including taking down old unsv earthing, complete all as specified and directed.
Supply annd fixing in repairs GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc all as specified.
Supply annd fixing in repairs GI pipe light grade 80 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc all as specified.
Material and labour in replacement of MCCB 3 pole 63 Amps 415 Volts with breaking capacity 16KA, Ics=75% Icu complete all as specified and directed.
Material and labour in replacement of MCCB 3 pole 100 Amps 415 Volts with breaking capacity 16KA ,Ics=75% Icu complete all as specified and directed.
Material and labour in replacement of MCCB 3 pole 160 Amps 415 Volts with breaking capacity 36KA complete all as specified and directed by E-in-C.
Material and labour in replacement of MCCB 3 pole 200 Amps 415 Volts with breaking capacity 36KA complete all as specified and directed by E-in-C.
Material and labour in replacement of MCCB 3 pole 250 Amps 415 Volts with breaking capacity 36KA complete all as specified and directed by E-in-C.
Material and labour in replacement of MCCB 3 pole 400 Amps 415 Volts with breaking capacity 36KA complete all as specified and directed by E-in-C.
Material and labour in replacement of thimble aluminium 400 Sqmm suitable for LT XLPE cable complete all as specified and directed by E-in-C.
Material and labour in replacement of thimble aluminium 185 Sqmm suitable for LT XLPE cable complete all as specified and directed by E-in-C.
Material and labour in replacement of thimble aluminium 120 Sqmm suitable for LT XLPE cable complete all as specified and directed by E-in-C.
Material and labour in replacement of thimble aluminium 95 Sqmm suitable for LT XLPE cable complete all as specified and directed by E-in-C.
Material and labour in replacement of thimble aluminium 70 Sqmm suitable for LT XLPE cable complete all as specified and directed by E-in-C.
Material and labour in replacement of thimble aluminium 50 Sqmm suitable for LT XLPE cable complete all as specified and directed by E-in-C.
Material and labour in replacement of thimble aluminium 35 Sqmm suitable for LT XLPE cable complete all as specified and directed by E-in-C.
Material and labour in replacement of thimble aluminium upto 25 Sqmm suitable for LT XLPE cable complete all as specified and directed by E-in-C.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
Plain Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation of poles or Struts and mass concrete, all as specified directed.
Supply and fixing in repairs LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing in repairs LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing in repairs LED street light fitting 75 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing in repairs LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
tender89.pdf
Tender Documents • 1.20 MB
BOQ_835691.xls
BOQ • 5.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .