Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹11.0 L
EMD Value
₹14,000
Closing Date
3 Mar 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC UPPTCL GREATER NOIDA
400 KV SUB STATION PALI GAUTAM BUDH NAGAR GREATER NOIDA
ELECTRCIAL WORK
2023_UPTCL_778378_1
VERY SHORT TERM T-62/2022-23ETC/GN
Open Tender
Electrical Works
Item Rate
10 days
KHURJA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ELECTRICITY 400 KV SUB STATION GREATER NOIDA
₹14,000
6 Mar 2023
25 Feb 2023
3 Mar 2023
25 Feb 2023
3 Mar 2023
25 Feb 2023
Amount
Dismantling, Carriage and erection of 132/33 KV 63 MVA Transformer at 220 KV Sub-Station Khurja. Dismantling of emulsifier system of damaged/burnt 63MVA Transformer by cutting of gas cutter and its shifting and proper stacking near safe place at 220 KV Substation Khurja.
Drain out of defective 63 MVA Transformer oil upto required level in empty oil drums/Oil tanker by the help of centrifuging machine at 220KV Sub-Station Khurja (Centrifuging machine shall be arranged by the contractor).
Complete dismantling the accessories of defective 63 MVA, 132/33 KV Transformer at 220KV Sub-Station Khurja after opening of jumpers, removal of earthing and opening of cables & cable connection, removal of all radiators, conservator tank, oil pipe lines, bushings, etc. to complete the jobs satisfactorily includingBlanking, nuts and bolts shall be provided by the department. All other T&P shall be arranged by the contractor at his own cost.
Shifting of main tank of defective 63MVA, 132/33 KV Transformer from plinth to safe place, approximate 20mtrs distance including turning of tank, if required including all T&P and all other works required to complete the job satisfactory.
(A)Additional shifting 95Mtr, 1 Job for every 5Mtr.
Shifting/ Dragging of new 63MVA 132/33KV Transformer from existing place to near loading place at 220 KV Sub-Station Sahibabad distance up to 20Mtr.
Loading of new 63MVA 132/33 KVTransformer main tank along with accessories, like oil filled drums, conservator tank, cooling fan etc, making the wooden sleeper plate-form jacking the T/F tank up to trailer height placing the rail under T/F tank and shifted up on trailer, removed the rail under T/F tank and proper tightening the main tank with trailer bad with the help of steel rope and turn buckle at 220KV Substation Sahibabad.
Carriage of new 63MVA 132/33 KV Transformer tank from 220KV Sub-Station Sahibabad to 220 KV Sub-Station Khurja along with all accessories by Pvt. Truck / Trailer. (Distance upto=100Km)
Unloading of main tank of new 63MVA 132/33 KV Transformer loaded on Trailer jacking the tank for packing the rail under the T/F tank and shifting it to wooden platform, Removing the rail under the T/F tank on wooden sleeper, lowering the tank towards ground by slowly and removing the wooden sleeper under the tank and unloading of various Transformer accessories of above new 63MVA 132/33 KV T/F like oil filled drums, bushing conservator tank, cooling fan etc. from Truck/ Trailer site at 220KV S/S Khurja.
Shifting/dragging of new 63MVA 132/33 KV Transformer from unloading place to plinth upto20mtrs distance including turning of Transformer if required including all T&P and other works to complete the job satisfactory.
Additional shifting 20Mtr, 1 Job for every 5Mtr.
(A) Complete, erection of new 63MVA 132/33 KV Transformer by erection of radiator, conservator tank, bushing with its turrets (if available) connecting of all oil pipe line, erection of cooling fans, making control cables connection, Buchholz relay etc. for completing the work, topping of T/F oil and final oil filling in tank, radiator, conservator tank and all other associates work for completion of work.
Placement of new RTCC panel (after dismantling of old RTCC panel) of this new 63MVA T/F in control room 1st floor at 220KV S/S Khurja including its Termination & fitting and laying of control cable if required as per site requirement and its connections.
Centrifuging of complete T/F oil in T/F by connecting centrifuging pipes circulating the T/F oil through PVT. centrifuging machine and taking the BDV value of the oil periodically till the required value is achieved. Approx19KL
Earthing of main tank of new 63MVA T/F by using M.S. flat 50X6 / 75X10 mm size, it’s jointing with already laid earth mat / Deltas. Neutral bushing support for its earthing work.
Making of Delta earthing for new 63MVA 132/33 KV Transformer as per UPPTCL Norms.
Jumpering of new 63MVA T/F from HV with single Moose/Zebra/ Panther and LV Side with Double Zebra/Moose /Panther complete up to 33KV Main Bus.
Dismantlingof 03 Nos 132KV LA by cutting of earthing strip opening of jumpers and structures (ALP) etc. Re-erection of 03Nos 132KV LA along with structure for complete the job satisfactory.
Installation of high velocity automatic water spraying system for 63 MVA T/F-1 including laying of fire direction water pipeline valves Quartzoid, HVWS nozzles along with all material complete as per details.Supply & laying above ground as required of different size GI pipe ‘B’ class Jindal/Tata-make for fire detection water pipe line as per IS specification (IS Code-1239) as per drawing enclosed complete with elbow tee socket reducer nuts and bolts with detail as below with anticorrosive treatment or painting as where required along with fabrication & fixing of L & U shape support with associated work to complete the job in all respect. (A) 65 NB
Supply & installation of 80 NB MS Pipe B class Jindal/Tata make for making support running of water/air pipe line including providing flange on bottom & its proper grouting with fastener as where required.
Supply & installation of flanges as per IS-1538 of different size as per drawing work include proper butt welding with pipe & proper packing and coupling with Nus & Bolt and fastener as required. (A) 80 NB
Supply & installation & commissioning of high velocity water spray nozzles flow capacity 305 Kg/Cm2 spray angle.
Supply & installation & commissioning of Quartzite bulb detectors (QBD) operator as 76 C0 sensing at rated temperature for actuation of the element 10/12 sec.
Supply & laying above ground of different size old & used including modification as required GI pipe B class (provided by the deptt.) for fire detection/water pipe line as per drawing enclosed complete with elbow tee socket reduce (provided by deptt.) with anticorrosive terminate or painting as where required along with fabrication & fixing of L&U shape support with associated work to complete the job in all respect. (A) 65 NB
Re installation of old & used including modification as required of 80 NB MS pipe B class (provided by deptt.) by for making support running of water air/pipe line including providing flange on bottom & its proper grouting with fastener nut bolt with anticorrosive treatment or painting as where required.
Re installation & commissioning of old & used high velocity water spray nozzles flow capacity 3.5 kg./cm2 spray core angle 90 (provided by deptt.)
Re installation & commissioning of old & used of Quarzoid bulb detectors (QBS) operate at6 760 C sensing at rated temp for actuation of the element 10/12 sec. (provided by deptt.)
Re installation & commissioning of 150 NB Deluge valve as per requirement of transformer which includes servicing of related fitting like 150 NB T-Strainer 2 No. gate valves another related parts of deluge valve.
Meena Elect & Engg. Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .