please refer BOQ
2020_PWDJK_103850_1
e-NIT No.EDJ/59 of 2020-21 Dated 08-09-2020
Open Tender
Electrical Works
Item Rate
Distric Hospital Samba
please refer to NIT
3 documents required · 3 mandatory
₹1,000
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹1.8 L
Yes
28 Sept 2020
8 Sept 2020
25 Sept 2020
9 Sept 2020
24 Sept 2020
9 Sept 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in partially laid surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly and having ROHS certification. The earthing pit should be covered with PVC cover.
Providing and laying of 25 x 5 mm copper strip from copper rod up-to the main panel.
Supplying and fixing of 600 mm x 600 mm size recessed mounted LED Luminaries 36 watt. having minimum 3600 Lumens with minimum lumens efficiency 115 Lumens/watt.
Supply, installation, testing & commissioning of pre-wired Recess /Surface Mounted LED Ceiling Light 12 W including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture CRCA housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16% & voltage input range 140-270 V with Shot circuit & overloading protection circuit off
SITC of pre-wired Surface Mounted Bulk Head Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required .
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply.
Ceiling fan 1200 mm sweep alongwith rod upto 1'-6" long
Exhaust fan 300 mm
OUTGOINGS MCCB 63Amps 4 P 36 KA Microprocessor based with (Icu=Ics=100%)(2 Nos) MCCB 125 Amps 4 P 36 KA Microprocessor based with (Icu=Ics=100%)(2 Nos) MCCB 25 Amps 4 P 36 KA Microprocessor based with (Icu=Ics=100%)(1 Nos) MCCB 100 Amps 4 P 36 KA Microprocessor based with (Icu=Ics=100%)(5 Nos) MCCB 160 Amps 4 P 36 KA Microprocessor based with (Icu=Ics=100%)(3 Nos) MCCB 250 Amps 4 P 36 KA Microprocessor based with (Icu=Ics=100%)(2 Nos) MCCB 320 Amps 4 P 36 KA Microprocessor based with (Icu=Ics=100%)(2 Nos) DP MCB 63 A 10 KA "D CURVE".(1 Nos) Indicating Lamps ON OFF TRIP( 17 Nos) Isolation Transformer of suitable Capacity for Control Wiring Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick.
OUTGOINGS MCCB 16 Amps 3 P 25 KA with Adjustable TMR (Icu=Ics=100%)(1 Nos) MCCB 25 Amps 3 P 25 KA with Adjustable TMR(Icu=Ics=100%)(2 Nos) MCCB 50 Amps 3 P 25 KA with Adjustable TMR (Icu=Ics=100%)(5 Nos) Indicating Lamps ON OFF TRIP( 8 Nos) Capacitor Duty Contactor 25 A (5 Nos) Capacitor Duty Contactor 12.5 A (2 Nos) Capacitor Duty Contactor 5 A (1 Nos) Capacitor 10 KVAR H.D 440 V Gas Filled(2 Nos) Capacitor 25 KVAR H.D 440 V Gas Filled(5 Nos) Capacitor 5 KVAR H.D 440 V Gas Filled(1 Nos) APFCR 8 Stages Auto Manual Switch(1 Nos) Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal)
Supplying and Laying of 1 No. PVC/XLPE insulated and PVC Sheathed /XLPE Power Cable of 1.1 KV Grade of Following Sizes in the existing RCC/Hume/DWC/Stone ware/Metal Pipe/Cable Tray as Required.
3.5C x 300 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
3.0C x 185 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
3.5C x 95 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
3.5C x 50 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
4C x 25 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
4C x 16 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5C x 300 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
3.5C x 185 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
3.5C x 95 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
3.5C x 50 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
4C x 25 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
4C x 16 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required
MS Anil Kumar Kapahi Contractor
M/S Om Prakash Sharma & Sons
M/S REAL TECK ENGINEERING
uttam chand
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .