| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.9 L+₹1.3 L (2.84%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance High Rate Quoted | |
| 3 | L3₹57.8 L+₹13.2 L (29.5%)Rejected-Finance | L3 | Rejected-Finance High Rate Quoted |
Tender Value
₹49.1 L
EMD Value
₹98,300
Closing Date
13 Dec 2023, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Provn of 01 Soakage well and 01 Septic Tank near bldg No. P-77 (Cook house), Addition/alteration of rewiring of conference hall and senior secondary block in Bldg No. P-78 and Spl repair to UG cable network and LT Panels near APS at Bikaner Mil Stn u
2023_MES_628380_1
CA No CWE BKN-Token No. 45/2023-2024
Open Tender
Civil Works
Item Rate
270 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (N) Bikaner
₹98,300
Yes
24 Jan 2024
15 Nov 2023
20 Dec 2023
15 Nov 2023
13 Dec 2023
29 Nov 2023
15 Nov 2023 - 20 Nov 2023
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and as directed.
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule.
Supply only integral water proofing compound (ISI marked) complete all as specified & as directed.
M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed. Note : Brick work under this item shall be carried out in sewage disposal work (i.e. manholes) and area drainage work (i.e. drains).
M&L for mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and directed. Note : Supply only integral water proofing compound shall be measured and paid for separately.
M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified.
M&L for 150mm bore reinforced concrete pipe, class NP2, laid and jointed complete with collars, laid and jointed on concrete bed complete including testing, complete all as specified & as directed. Note :- Excavation & earthwork shall be measured and paid separately.
M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and as directed.
M&L for cutting into existing manholes/Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, reforming benching as required and finishing surface even & smooth for 150mm bore pipe complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
M&L for construction of Septic Tank for 100 users, brick construction, complete, all as specified and shown on drawings (BTD-016 Sheet No. 1/3 to 3/3).
M&L for construction of Soak Well for 100 users, brick masonry, complete, all as specified and shown on drawings (BTD-830 Sheet No. 1/1).
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for Modular point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular switches, sockets, regulators etc with and including modular cover plates with frame of requisite module, complete all as specified and as directed. Notes : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for modular metal flush boxes of requisite module and modular cover plates with frame of requisite module of colour as approved by GE.
All as per serial item No. 20.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 20.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 20.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
All as per serial item No. 20.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F Modular switch 1 way 6A, 1 module, complete all as specified and as directed.
S&F Modular switch, 1 way 16 Amp, 1 module, complete all as specified and as directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F Modular Fan step regulator, 120 Watt - 2 module, complete all as specified and as directed.
Taking down of serviceable and refixing after LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
Taking down of serviceable and refixing after LED light fitting, 2 feet, 5 Watt, 230 Volts, AC decorative type with driver holder and LED lamp and accessories and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
Taking down of serviceable LED 600x600mm, 35/36 watt, 220 volt, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size and refixing the same position after repair complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, fixed as in repair complete all as specified and as directed.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, IP-43 protection, IK-09 with metal door, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, VTPN, DB, vertical load line, 4 way, 415 Volts, fitted with and accessories, including taking down old existing unserviceable DB with fixtures of any type complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 12 way, 240 Volts, fixed as in repairs, complete all as specified and as directed.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, fixed as in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed as in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed as in repairs, complete all as specified and as directed.
S&FS&F MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep, keeping side to store in safe custody for painting of ceiling fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
M&L for taking down carefully existing serviceable circulator fan of any sweep and re-fixing / hanging the same after proper cleaning and connecting up with and including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto ceiling rose, complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with Four runs of 10 sqmm (nominal area) size main cable & Two run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 32mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 04 runs of 10 sqmm size main cable, 02 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 240 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for cable jointing kit for 1100 Volt cable for indoor/outdoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volt cable for indoor/outdoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed.
M&L for Boring of holes of 80mm bore under road, pavement, hard standing, (minimum 1.0m below) etc by trench less technology using necessary machine / manually without disturbing the top surface suitable for passing the GI protection pipe / cables, complete all as specified and as directed.
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for earth continuity conductor or main earthing lead fixed to wall or batten or recess or chesses or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop galvanized iron strip 32mm x 6mm buried in ground, fixed as in repair, complete all as specified & as directed. Note : Excavation & earthwork shall be measured & paid for separately under respective items of this Schedule.
Supply, installing, commissioning and testing factory made and tested (CPRI type test certified) LT Feeder Pillar Box cubical type (KIOSK) of size as per IS specification, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz AC supply system, protection class IP-53, dust & vermin proof for outdoor use, made out of CRCA sheet 3.15 mm thick, powder coated inside & outside of flint grey shade (RAL-7032), double door (front & rear) machine pressed, both side opening in two shalves with provision of rubber beading and locking system, including copper bus bar of 800 Amp capacity, 4 strip in colour code mounted on porcelain insulator, bus bar chamber shall be provided with inspection cover for each MCCB/cubical switch shall have the independent opening, locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sides and panel shall be mounted on angle iron frame and legs made from angle of size 50x50x5 mm including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size but not less then 6 sqmm with proper ferrule & cable glands for each entry of cable, including danger notice sticker, comprising & including the following accessories complete all as specified and as directed including taking down old unserviceable LT Panel. Note :- All switch gear shall have following specification :- (a) communication, Trip history, LCD- Indication of measurement and information, Adjustable over load from 40% to 100%, Inbuilt ground fault protection 20% to 100% Adjustable neutral overload protection 50% to 100%, Adjustable current inbalance protection available 30% to 70%, Provision of thermal memory : ON/OFF (b) MCCB 400 Amp 36 kA, 4 Pole, Ics=100% Icu with built in protection functions for overload, short circuit current adjustable type microprocessor release based complete with spreader link and extendable ON/OFF rotary handle – 01 No. (Incomer). Make : ABB/Siemens/ Schneider/C&S (Description of serial item No. 57.00 contd....)
(Description of serial item No. 57.00 contd....) (c) MCCB 200 Amp 36 kA, 4 Pole, Ics=100% Icu with built in protection functions for overload, short circuit current adjustable type microprocessor release bases complete with spreader link and extendable ON/OFF rotary handle – 03 Nos (Outgoing) Make : ABB/Siemens/ Schneider/C&S. (d) MCCB 100 Amp 36 kA, 4 Pole, Ics=100% Ics with built in protection functions for overload, short circuit current adjustable type microprocessor release bases complete with spreader link and extendable ON/OFF rotary handle - 05 Nos (Outgoing). Make : ABB/Siemens/ Schneider/C&S. (e) LED frequency meter CI 0.2 (f) Three Phase Voltmeter CI 0.5 Input voltage measurement range 50-520 (g) Three phase Ammeter CI 0.5 with CT copper wound CT Coil (h) LED Indicator lamps (RYB) & bakelite fuse showing - 01 Set Note : Foundation/platform shall be in PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate (Foundation not less than 450mm above the ground level and not less than 300mm below the ground level) including necessary form work & 10mm thick cement plaster on exposed surfaces in CM 1:4 duly applied with three coats of white wash and quoted rate shall deemed inclusive of same.
Supply, installing, commissioning and testing factory made and tested (CPRI type test certified) LT Feeder Pillar Box cubical type (KIOSK) of size as per IS specifications, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz AC supply system, protection class IP-53, dust & vermin proof got outdoor use, made out of CRCA sheet 3.15 mm thick, powder coated inside & outside of flint grey shade (RAL-7032), double door (front & rear), machine pressed, Both side opening in two shalves with provision of rubber beading and locking system, including copper bus bar of 600 Amp capacity, 4 strip in colour code mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers for each MCCB/cubical switch shall have the independent opening, locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sides and panel shall be mounted on angle iron frame and legs made from angle of size 50x50x5 mm including internal wiring with PVC insulated stranded copper conductor FRLS cable of appropriate size but not less than 6 sqmm with proper ferrule & cable glands for each entry of cable, including danger notice sticker, comprising & including the following accessories complete all as specified and as directed including taking down old unserviceable LT Panel. Note :- All switch gear shall have following specification :- (a) communication, Trip history, LCD- Indication of measurement and information, Adjustable over load from 40% to 100%, Inbuilt ground fault protection 20% to 100% Adjustable neutral overload protection 50% to 100%, Adjustable current inbalance protection available 30% to 70%, Provision of thermal memory : ON/OFF (Description of serial item No. 58.00 contd....)
(Description of serial item No. 58.00 contd....) (b) MCCB 315 Amp 36 kA, 4 Pole, Ics=100% Ics with built in protection functions for overload, short circuit current adjustable type microprocessor release based complete with spreader link and extendable ON/OFF rotary handle – 01 No (Incomer). Make : ABB/Siemens/ Schneider/C&S (c) MCCB 200 Amp 36 kA, 4 Pole, Ics=100% Ics with built in protection functions for overload, short circuit current adjustable type microprocessor release based complete with spreader link and extendable ON/OFF rotary handle – 02 Nos (Outgoing). Make : ABB/Siemens/ Schneider/C&S (d) MCCB 100 Amp 36 kA, 4 Pole, Ics=100% Ics with built in protection functions for overload, short circuit current adjustable type microprocessor release based complete with spreader link and extendable ON/OFF rotary handle – 1 No (Outgoing). Make : ABB/Siemens/ Schneider/C&S. (e) LED frequency meter CI 0.2 (f) Three Phase Voltmeter CI 0.5 Input voltage measurement range 50-520 (g) Three phase Ammeter CI 0.5 with CT copper wound CT Coil (h) LED Indicator lamps (RYB) & bakelite fuse showing - 01 Set. Note : Foundation/platform shall be in PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate (Foundation not less than 450mm above the ground level and not less than 300mm below the ground level) including necessary form work & 10mm thick cement plaster on exposed surfaces in CM 1:4 duly applied with three coats of white wash and quoted rate shall deemed inclusive of same.
Supply, installing, commissioning and testing factory made and tested (CPRI type test certified) LT Feeder Pillar Box cubical type (KIOSK) of size as per IS specification, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-53, dust & vermin proof for indoor use, made out of CRCA sheet 3.15 mm thick, powder coated inside & outside of flint grey shade (RAL-7032), double door (front & rear), machine pressed, Rear side opening in two shalves with provision of rubber beading and locking system, including copper bus bas of 300 Amp capacity, 4 strip in colour cod mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers for each MCCB/cubical switch shall have the independent opening, locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sides and panel shall be mounted on angle iron frame and legs made from angle of size 50x50x5 mm including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size but not less than 6 sqmm with proper ferrule & cable glands for each entry of cable, including danger notice sticker, comprising & including the following accessories complete all as specified and as directed including taking down old unserviceable LT Panel. Note :- All switch gear shall have following specification :- (a) communication, Trip history, LCD- Indication of measurement and information, Adjustable over load from 40% to 100%, Inbuilt ground fault protection 20% to 100% Adjustable neutral overload protection 50% to 100%, Adjustable current inbalance protection available 30% to 70%, Provision of thermal memory : ON/OFF (Description of serial item No. 59.00 contd....)
(Description of serial item No. 59.00 contd....) (b) MCCB 200 Amp 36 kA, 4 Pole, Ics=100% Ics with built in protection functions for overload, short circuit current adjustable type microprocessor release based complete with spreader link and extendable ON/OFF rotary handle – 02 Nos (Incomer). Make : ABB/Siemens/ Schneider/C&S (c) MCCB 63 Amp 36 kA, 4 Pole, Ics=100% Ics with built in protection functions for overload, short circuit current adjustable type microprocessor release based complete with spreader link and extendable ON/OFF rotary handle – 05 Nos (Outgoing). Make : ABB/Siemens/ Schneider/C&S. (d) LED frequency meter CI 0.2 (e) Three Phase Voltmeter CI 0.5 Input voltage measurement range 50-520 (f) Three phase Ammeter CI 0.5 with CT copper wound CT Coil (g) LED Indicator lamps (RYB) & bakelite fuse showing - 01 Set. (h) Onload change over switch 200 Amps, 4 Pole - 01 Nos. Note : Foundation/platform shall be in PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate (Foundation not less than 450mm above the ground level and not less than 300mm below the ground level) including necessary form work & 10mm thick cement plaster on exposed surfaces in CM 1:4 duly applied with three coats of white wash and quoted rate shall deemed inclusive of same.
M&L for cable route indicator made of pre cast reinforced cement concrete 1:2:4 (20mm graded crushed stone aggregate), type B-1 of size 50cm x 5cm x 100cm and all finished surfaces duly marked with ‘DANGER/1.1 KV cable’ embossing on two sides of the route indicator and letters painted with thick approved colour, burried in ground for a depth 45cm including necessary excavation and PCC complete all as specified and as directed. Notes : (i) These shall be fixed along the route of cable at 30 meter interval & on every turning & cable joint as directed. (ii) PCC and earth work for fixing cable route indicator deemed to be including this items.
M/s Rohit Construction Co.
V.K. Infra Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .