Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC CHOLADHARA JORAHAT 785001 ASSAM | JORHAT | ASSAM | 785001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹51.4 L+₹4.5 L (9.62%)Rejected-Finance VILL JAMALPUR P O NAYA MAHMMADPUR DISTT BHOJPUR ARA PIN 802163 | ARA | BHOJPUR | BIHAR | 802163 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹88,680
Closing Date
5 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
UPGRADATION OF EXTERNAL ELECTRICIAL SUPPLY IN CSD DEPOT NARANGI UNDER GE GUWAHATI
2022_MES_562193_1
GE/GUW/64/8282 OF 2022-23
Open Tender
Civil Works
Item Rate
120 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹88,680
Yes
14 Jan 2023
9 Nov 2022
7 Dec 2022
9 Nov 2022
5 Dec 2022
23 Nov 2022
9 Nov 2022 - 16 Nov 2022
Amount
Excavation in trenches not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables, pole foundation, etc and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5m in depth and not exceeding 3 m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables, pole foundation, etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand,(approved source) as per standard practice with proper compaction complete all as specified and directed.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 50 sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 150 sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 300 sqmm 3½ core complete all as specified and as directed.
S&F in repair 150 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid in trenches, road crossing, drain crossing, under floor or fixed to iron structures/poles complete all as specified and directed.
Dismantling of ACSR or AAC conductors of any description complete all as directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete complete all as directed.
S&F VTPN DB, MCCB incomer,4 ways double door, IP-43 IK 09 in 200Amps rated bus bars,earth bar,neutral links, complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces complete all as specified and as direct.
Dismantling/taking down insulators of any type or size complete complete all as directed.
M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and as directed.
S&F fixed thermal and fixed magnetic 4 Pole MCCB 125 Amps, 415 Volt, 16 KA complete all as specified and directed.
S&F Digital time switch (having Latitude/Longitude precise to the minute with time zone) , 240 Volts, Single phase, 20Amps rating with contactor fitted inside encloser complete complete all as per manufacturers instruction and as directed.
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6 mm thick, buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to Earth Lead Wire 4.0 mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, earthing complete all as specified and as directed.
Supply, installing, commissioning and testing of factory made LT Panel board, TPN, 415 Volts, cubical type, floor mounted, outdoor type, suitable for 415 volts AC, CPRI approved factory made, double door, dust and vermin proof IP 54, fabricated out of CRCA sheet of not less than 3.15mm thick with 2mm thick for internal compartment dully powder coated tand supported by 50 mm x 50 mm x 6 mm MS angle iron frame with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alloy aluminum busbar suitable for carrying of current 400 Amps with suitable connections from MCCB;s outgoing to main busbar shall be carried out with TPN copper busbar of suitable rating and connection from main busbar to out going MCCB;s (intake point) will be carried out with TPN copper busbar as per MCCB rating dully insulated and colour coded heat shrinkable sleeves and shall be rigidly mounted on suitable size of bridge insulators including necessary earth work and PCC foundation(type C2, 1:3:6) of minimum 0.35meter height positioned and fixed with suitable nuts, bolts, washers etc. to MC pedestal and dismantlinf the existing unserviceable panel box complete all as specified and directed and comprising of the following :- (a) MCCB 400 Amps, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rapturing capacity 36 KA-01 Nos(Incomming) (b) MCCB 100 Amps, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rapturing capacity 25 KA-06 Nos(Outgoing) (c) 3 Phase digital multi function meter, model A, Class 1, 5 Amps with relay Vega Series: 01 Nos (d) Indicating Lamp 240 Volts LED type: Set of three
Supply, installing, commissioning and testing of factory made LT Panel board, TPN, 415 Volts, cubical type, floor mounted, outdoor type, suitable for 415 volts AC, CPRI approved factory made, double door, dust and vermin proof IP 54, fabricated out of CRCA sheet of not less than 3.15mm thick with 2mm thick for internal compartment dully powder coated tand supported by 50 mm x 50 mm x 6 mm MS angle iron frame with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alloy aluminum busbar suitable for carrying of current 315 Amps with suitable connections from MCCB;s outgoing to main busbar shall be carried out with TPN copper busbar of suitable rating and connection from main busbar to out going MCCB;s (intake point) will be carried out with TPN copper busbar as per MCCB rating dully insulated and colour coded heat shrinkable sleeves and shall be rigidly mounted on suitable size of bridge insulators including necessary earth work and PCC foundation(type C2, 1:3:6) of minimum 0.35meter height positioned and fixed with suitable nuts, bolts, washers etc. to MC pedestal and dismantlinf the existing unserviceable panel box complete all as specified and directed and comprising of the following :- (a) MCCB 200 Amps, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rapturing capacity 16 KA-01 Nos(Incomming) (b) MCCB 63 Amps, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rapturing capacity 10 KA-06 Nos(Outgoing) (c) 3 Phase digital multi function meter, model A, Class 1, 5 Amps with relay Vega Series: 01 Nos (d) Indicating Lamp 240 Volts LED type: Set of three
J K CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .