Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Improvement and development of electrical installation at toilets near Supreme Court , Lotus Temple road and near Nizamuddin Puzzle Parking for AI Summit 2026 Under Central Zone.
2026_MCD_265059_1
EE(Elect.)/CNZ/2025-26/56-03
Open Tender
Electrical Works
Percentage
5 days
AI Summit
Please refer Tender documents.
2 documents required · 2 mandatory
₹177
₹2,100
9 Mar 2026
2 Feb 2026
3 Feb 2026
2 Feb 2026
3 Feb 2026
2 Feb 2026
Supply of 1.5.sq .mm ISI mark ,FRLS PVC insulated, single core copper conductor cable.
Supply of 2.5.sq .mm ISI mark ,FRLS PVC insulated, single core copper conductor cable.
Supply of 4 .sq .mm ISI mark ,FRLS PVC insulated, single core copper conductor cable.
Supply of 25 mm dia. ISI marked ,PVC conduit
3 mm thick phenolic laminated sheet
Supply of S.P. 5/6 amps, one way switch, piano type ISI marked
Supply of S.P. 15/16 A, one way switch, piano type ISI marked
Supply of 3 pin 5/6 amps socket outlet, piano type ISI marked
Supply of 6 pin 15/16 & 5/6 amps socket outlet, piano type ISI marked
Supplying of 6 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity.
Supplying of 40 A, 2 pole isolator.
2+6 way, SPN, single door, MCB DB
Supply of 10" (250mm) sweep 1250 rpm exhaust fan Fresh Air type complete with shutter ,blades etc as required
Repair/Rewinding of existing 1.0 HP mono block pumpset including replacement of parts like gun metal bush /bearings, condenser, impellar etc to make the pump functional as required.
SITC of single phase monoblock pumpset complete with all accessories workable of 240 Volts 50 Hz AC supply (a) 1 HP (0.75 KW) single phase pumpset head from 12-30 metre suction and delivery 25X25 mm.
Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD <10%,P.F.≥0.95,IP20, CRI >80, Flicker free,(flicker shouldbebelow5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trademark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).CRCA Sheet Body (Thickness > 0.50 mm) 18-22 watt
Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD <10%asperIEC61000-3-2,P.F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMI-EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT3000°K/4000°K /5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5year OEM warranty. System lumen efficacy 105 <120lm/Watt output.LM79&LM80Testreport from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 50 watt
Supply of XLPE insulated PVC sheathed Al. Conductor Un-Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*4 sqmm
Providing 1 nos Skilled Labour/wireman for day to day maintenance of all CTs/PTs under central zone for the period of one day.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.76 MB
Tendernotice_2.pdf
PDF • 12.40 MB
Tendernotice_3.pdf
PDF • 0.10 MB
BOQ_307717.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .