Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC BALIJAN PANIHARA GAON PO DINJOY CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹10.7 L+₹1.8 L (20.6%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹11.2 L+₹2.3 L (25.4%)Rejected-Finance SUDHA RANI VILA GROUND FLOOR 65 NASKAR PARA ROAD KOLKATA 700041 | KOLKATA | KOLKATA | WEST BENGAL | 700041 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.2 L+₹3.3 L (37.6%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L4 | Rejected-Finance Other than L1 | |
| 5 | L4₹12.2 L+₹3.3 L (37.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
12 Oct 2021, 6:00 pmClosed
GE (AF) Mohanbari
Garrison Engineer AF Mohanbari Mohanbari Post Dibrugarh Assam 786012
REPAIR AND MAINTENANCE TO EXTERNAL WATER SUPPLY DG SETS SECURITY LIGHTS STREET LIGHTS BUILDING SECURITY LIGHTS FIRE ALARM AND DEDUCTION SYSTEM AND OTHER CONNECTED E M NATURE OF WORK AT ALG ALONG AND WALONG UNDER GE (AF) MOHANBARI 2ND call
2021_MES_461174_2
8001/317/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Mohanbari
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Mohanbari
₹20,000
Yes
2 Nov 2021
18 Sept 2021
14 Oct 2021
18 Sept 2021
12 Oct 2021
25 Sept 2021
Amount
Routine maintenance consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc for efficient functioning including provision of all consumables items like cotton, waste cloth, kerosene oil etc for repair. Maintenance will be carried out all as specified for various capacity DG Sets here-in-after and as directed. (a) Cleaning, dusting of DG set including motor starter and control panel etc. (b) Checking clearance of suction and exhaust valves and adjust if required (c) Checking of rubber seal, gasket and hosepipe (d) Tightening of all nut bolts. (e) Greasing of all points. (f) Checking of any leaking in fuel and oil lines. (g) Cleaning of fuel tank by taking out the dirt and sludge, cleaning the tank thoroughly. (h) Adjusting valve tappet clearence/timing. (i) Injector pressure test cleaning and repairing, tightining fasteners and making lubrication leak proof. (j) Repair/rewiring of broken/damaged control panel connection including measuring instruments, indicators, engine protection devices etc. Note : (i) DHPP (N) required at the time of maintenance/testing will be issued under Sch "B" 'Free for filling'. (ii) Labour charges for dismantling/taking down of old unserviceable spare parts as and when required is deemed to be included in unit rate quoted. (iii) Labour charges for dismantling/taking down and refixing of old serviceable spare parts as and when required is deemed to be included in unit rate quoted. (iv) Routine maintenance carried through OEM/OEM authrised Dealers only and certification of OEM to be produced complete.
DG set of Capacity 320 KVA DG Set Make: Kirloskar (Koel Green)
DG set of Capacity up to and including 15 to 35 KVA Make: Kirloskar (Koel Green)
Supply and fixing of the following spare parts of 320 KVA DG set. Make Kirloskar (koel Green)
Air Filter
Fuel Filter
fan belt
fuel pipe (inlet and outlet pair)
nozzle valve
Supply and fixing of the following spare parts of 35 KVA DG set. Make Kirloskar (koel Green)
Air Filter
Fuel Filter
fan belt
fuel pipe (inlet & outlet pair)
Lube Oil pipe
water temp gauge
Supply and filling Lubricant Engine Oil 15W40 complete all as specified and directed by the Engineer-in Charge. Make : Castrol / Volvoline/Servo/HP
Supply and filling Hydraulic governer oil suitable to Kirloskar Koel Green DG sets complete all as specified and directed by the Engineer-in Charge. Make : Castrol / Volvoline/Servo/HP
Supply and topping heavy duty concentrate/Antri freeze type coolant in radiator assembly, suitable to Kirloskar Koel Green DG sets complete all as specified and directed by the Engineer-in Charge. Make : Castrol / Volvoline/Servo/HP
Material and labour for conditioning of battery 12 Volt, upto 180 AH, to drain out distilled water and Acid, taking out damaged lead plates complete for replacing with new lead plates of suitable weight & size including supplying and filling fresh lead acid , distilled water, microporus seperater and testing for satisfactory functioning etc complete all as specified and directed by the Engineer-in Charge
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp with impact and corrosion resistant, IP 65/66 protection including assembling of complete fitting and its testing before and after mounting or erection etc for proper functioning and taking down existing complete all as specified and directed by Engineer-in-charge.
Taking down existing unservicebale service main / sub main wiring complete all as specified from electric poles to service brackets, wall etc. including removing of unserviceable wiring complete all as specified and directed by the Enginner-in- Charge
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FR cable of size 4.0 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FR cable of size 4.0 sq mm including 20 mm dia PVC conduit medium grade exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified and directed by the Engineer-in Charge
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FR cable of size 6.0 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FR cable of size 6.0 sq mm including 20 mm dia PVC conduit medium grade exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified and directed by the Engineer-in Charge
Supply and fixed in repairs TPN (4 pole) power contactor type MCX-22, 100 Amps 415 Volts 50 Hz AC supply etc complete all as specified and directed by the Engineer-in Charge
Supply and fixed in repairs MCB TPN 40 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixing in replacement of MCCB 4 Pole, 63 Amps, 18 KA breaking capacity, 415Volts, AC 50 Hz, with overload and thermal tripping features, Icu 100% complete all as specified and as directed. Note: Any minor addition and alteration shall be made in paneal board if required during execution of work shall be carried out by the contractor without any extra cost to Government and rate quoted shall be deemed inclusive and no extra claim shall be entertained at later stage. etc complete all as specified and directed by the Engineer-in Charge
Supply and fixing in replacement of MCCB 4 Pole, 100 Amps, 18 KA breaking capacity, 415Volts, AC 50 Hz, with overload and thermal tripping features, Icu 100% complete all as specified and as directed. Note: Any minor addition and alteration shall be made in paneal board if required during execution of work shall be carried out by the contractor without any extra cost to Government and rate quoted shall be deemed inclusive and no extra claim shall be entertained at later stage. etc complete all as specified and directed by the Engineer-in Charge
Dismantling of existing old unserviceable thermostat of Geyser of 50/35/25 Liters and Supply and fixing new thermostat with specifications to match with the existing one, including refixing all connections, testing for functionality etc. complete all as specified and directed by Engineer-in-charge
Dismantling of existing unserviceable plug top of Geyser of 50/35/25 Liters and Supply and fixing 15 Amp, 3 Pin, 230V, 50 Hz plug top with all connections and acessories complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair PVC Connection pipe 15 mm dia 60 cm ( hot and cold) long heavy duty with two Nos brass chromium plated union complete all as specified and directed by Engineer-in-charge
Dismantling of existing unserviceable heating element from geyser of 50 litre capacity and Supply and fixing new heating element of 2.0 kw 230 volt, testing for its functionality and refixing all electrical and water connections complete all as specified and directed by Engineer-in-charge
Dismantling of existing unserviceable heating element from geyser of 25 litre to 35 litre capacity and Supply and fixing new heating element of 1.5 kw 230 volt, testing for its functionality and refixing all electrical and water connections complete all as specified and directed by Engineer-in-charge
Supply and fixed in repairs 15 Watts LED bulb minimum lumen 1500 only etc complete all as specified and directed by the Engineer-in Charge
Supply and fix in replacement of LED light fitting 1 x 18 watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge
Supply and fix in replacement of LED light fitting 1 x 20 watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge
Material and labour for checking of ceiling fans after taking down the fan carefully from any position and removing from site to workshop, rewinding of fan coil after removing the blades with super quality, super enameled copper wire of suitable gauge and heat varnishing and refixing the same in original position including greasing of bearings & other moving parts and replacement of 2.5 mfd capacitor and testing complete all as specified and directed by Engineer-in-charge
Material and labour for servicing of Indoor and Outdoor unit of Split type AC of capacity 1.5 TR by means of electric blower and water under pressure cleaning & Washing of condensing Coil/ Cooling Coil by Soap Solution or recommended chemical, oiling and greasing of Moving parts such as blower motor etc complete all as specified and directed by the Engineer-in Charge
Supply and charging refrigeration gas R-22 for Split AC complete all as specified and directed by the Engineer-in Charge
S K ENTERPRISE
R K CHAKRABORTY AND CO
M/s Shiva Technical Enterprise
M/s PRABIR ENTERPRISE
kabitaconstruction
KP GHOSH AND CO
M/S RK Trading
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .