Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC BEING LOWEST TENDER | |
| 2 | L2₹37.7 L+₹9.3 L (32.8%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹39.4 L+₹11.0 L (38.9%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹47.4 L+₹19.0 L (67.0%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO CONTRACTOR NOT ENLISTED IN PARTICULAR CATEGORY c (i) |
| Sl No | Description | Qty | Unit | SUPER COOL L1 | ANAND REFRIGERATION L4 | p.chinnasamy L2 | PRIYA ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | |||||||
| 2.00 | S&F in replacement of condensor fan motor 2 HP capacity suitablr for 75 TR AC palnt complete all as specifed and directed by Engr-In-Charge. | 2 | Each | 18,000 ₹36,000 Lowest | 25,000 ₹50,000 | 19,500 ₹39,000 | 26,000 ₹52,000 |
| 3.00 | S&F in replacement of timer suitable for 75 TR AC plant complete all as specifed and directed by Engr-In-Charge. | 1 | Each | 3,400 ₹3,400 Lowest | 6,800 ₹6,800 | 4,800 ₹4,800 | 6,500 ₹6,500 |
| 4.00 | S&F in replacement of contactor SP 12 to 40 AC suitable for condensor of 75 TR AC plant complete all as specifed and directed by Engr-In-Charge. | 4 | Each | 9,000 ₹36,000 | 7,000 ₹28,000 | 6,650 ₹26,600 Lowest | 7,200 ₹28,800 |
| 5.00 | S&F in replacement of MCB 3 pole 63 Amps complete all as specifed and directed by Engr-In-Charge. | 5 | Each | 650 ₹3,250 | 3,300 ₹16,500 | 2,475 ₹12,375 | 500 ₹2,500 Lowest |
| 6.00 | S&F in replacement of MCB 3 pole 16 Amps suitablr for fan condensor complete all as specifed and directed by Engr-In-Charge. | 2 | Each | 1,000 ₹2,000 Lowest | 2,620 ₹5,240 | 1,965 ₹3,930 | 2,150 ₹4,300 |
| 7.00 | S&F in replacement of MCCB 4/3 pole , 250 Amps AC supply , 50 Hz complete all as specifed and directed by Engr-In-Charge. | 1 | Each | 19,000 ₹19,000 Lowest | 40,000 ₹40,000 | 34,200 ₹34,200 | 41,500 ₹41,500 |
| 8.00 | S&F in replacement of MCCB 4/3 pole ,150 Amps AC supply , 50 Hz complete all as specifed and directed by Engr-In-Charge. | 2 | Each | 9,000 ₹18,000 Lowest | 26,500 ₹53,000 | 30,200 ₹60,400 | 27,800 ₹55,600 |
| 9.00 | S&F in replacement of fuse (TSK 250) complete all as specifed and directed by Engr-In-Charge. | 2 | Each | 2,500 ₹5,000 Lowest | 7,000 ₹14,000 | 4,758 ₹9,516 | 6,800 ₹13,600 |
| 10.00 | S & F in replacement of temprature gauge 0-50 degree C with flare nut complete all as specified and as directed. | 4 | Each | 1,750 ₹7,000 Lowest | 5,500 ₹22,000 | 3,852 ₹15,408 | 6,000 ₹24,000 |
Tender Value
Refer Docs
EMD Value
₹59,900
Closing Date
14 Jul 2025, 6:00 pmClosed
GE AF SULUR
KANGEYAPALYAM
REPAIR/ MAINT OF AIRCONDITIONING UNITS INSTALLED AT FMS AND OTHER CERTAIN LOCATION AND ATTENDING COMPLAINTS INCLUDING CERTAIN MISC E/M WORKS AT AF STN SULUR
2025_MES_716238_1
8768/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer to tender document
7 documents required · 7 mandatory
₹500
GE AF SULUR
₹59,900
Yes
20 Sept 2025
23 Jun 2025
16 Jul 2025
23 Jun 2025
14 Jul 2025
7 Jul 2025
25 Jun 2025 - 4 Jul 2025
Amount
SCHEDULE A BOQ
S&F in replacement of condensor fan motor 2 HP capacity suitablr for 75 TR AC palnt complete all as specifed and directed by Engr-In-Charge.
S&F in replacement of timer suitable for 75 TR AC plant complete all as specifed and directed by Engr-In-Charge.
S&F in replacement of contactor SP 12 to 40 AC suitable for condensor of 75 TR AC plant complete all as specifed and directed by Engr-In-Charge.
S&F in replacement of MCB 3 pole 63 Amps complete all as specifed and directed by Engr-In-Charge.
S&F in replacement of MCB 3 pole 16 Amps suitablr for fan condensor complete all as specifed and directed by Engr-In-Charge.
S&F in replacement of MCCB 4/3 pole , 250 Amps AC supply , 50 Hz complete all as specifed and directed by Engr-In-Charge.
S&F in replacement of MCCB 4/3 pole ,150 Amps AC supply , 50 Hz complete all as specifed and directed by Engr-In-Charge.
S&F in replacement of fuse (TSK 250) complete all as specifed and directed by Engr-In-Charge.
S & F in replacement of temprature gauge 0-50 degree C with flare nut complete all as specified and as directed.
S&F in replacement of butterfly valve size 150 mm with rubber gas kit complete all as specified and as directed.
S&F in replacement of butterfly valve size 100 mm with rubber gas kit complete all as specified and as directed.
S&F in replacement of butterfly valve size 75/80 mm with rubber gas kit complete all as specified and as directed.
S&F in replacement of butterfly valve size 50/65 mm with rubber gas kit complete all as specified and as directed.
S&F in replacement of balancing valve size 150 mm all as specified and directed by Engr-in-Charge.
S&F in replacement of water flow switch make donforce all as specified and directed by Engr-in-Charge.
S&F in replacement of `V' belt size B-67 complete all as specified and as directed.
S&F in replacement of Display board of chiller unit suitable for 75TR AC plant complete all as specified and as directed.
S&F in replacement of PCB of any type of chiller unit suitable for 75TR AC plant complete all as specified and as directed.
S&F in replacement of micro processor computer control of any type suitable for 75TR AC plant complete all as specified and as directed.
S&F in replacement of water temp sensor suitable for 75TR AC plant complete all as specified and as directed.
S&F in replacement of pressure gauge 0-230 PSI all as specified and as directed.
S&F in replacement of 'Y' stainer size 150 mm including gas kit and welding , soldering & insulation for leak arrest all as specified and as directed.
S&F in replacement of 'Y' stainer size 75 mm including gas kit and welding , soldering & insulation for leak arrest all as specified and as directed.
S&F in replacement of 'Y' stainer size 50 mm including gas kit and welding , soldering & insulation for leak arrest all as specified and as directed.
S&F in replacement of bellow size 100 mm including gas kit and welding , soldering & insulation for leak arrest all as specified and as directed.
S&F in replacement of primary & secondry bellow size 150 mm including gas kit and welding , soldering & insulation for leak arrest all as specified and as directed.
S&F in replacement of temprature sensor 32 degree to 110 degree C for AHU all as specified and as directed.
M&L for taking down unsv PCB control panel of any type and size of AC plants and bring it to service center for repair than tesiting and refixing in same position up to staifaction level working condition all as specified and directed by Engr-In-Charge.
S&F in replacement of fuse 63 A all as specified and as directed.
S&F in replacement of AHU pre filter 287x430x50 mm all as specified and as directed.
S&F in replacement of AHU pre filter 430x430x50 mm all as specified and as directed.
S&F in replacement of AHU pre filter 595x490x50 mm all as specified and as directed.
S&F in replacement of AHU pre filter 490x490x50 mm all as specified and as directed.
S&F in replacement of DP switch for AHU all as specified and as directed.
S&F in replacement of siflon all as specified and as directed.
M & L for dismantling burnt out three phase, 50 C/S capacity 10 HP motor for rewinding with same guage, weight and same number of turns of super annealed copper wire including paper/tape of approved quality and varnishing with Class I varnishing compound including heating and re-assembling the motor, testing and commissioning after repair including replacement of worn out bearing complete all as specified.
All as per item above but motor capacity 7.5 HP.
All as per item above but motor capacity 5 HP.
All as per above but induction motor capacity 5 HP
Taking down old unserviceable scroll type compressor of capacity 15 TR including supply and replacement of same capacity of compressor of Make Emerson Climate Technologies or equivalent make for AC plant .
M & L for leak testing of AHU unit cooling coil after pumping down the complete system, isolating the cooling coil from both ends and charging the dry nitrogen gas for pressure leak test, after detecting leak point, release the nitrogen gas, repairing the leak point but means of soldering/brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerent, testing and commissioning up to satisfactory cooling performance of 75TR capacity at FMS. Note: (i) Refrigerent gas shall be mesaured and paid separately as supply only. (ii) Nitrogen gas required deemed to be inclusive in the quoted rate.
M&L for Cleaning / servicing the cooling coil of AHU AC plant by pressure air method with using air blower and cleaning the cooling coil with cleaning the solution, cleaning the AHU base tray completely , including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter replacement of V-belt ( if required) of 11000 CFM capacity at FMS complete all as specified and as directed.
All as ditto as per item No : 42 here in before but 6600 CFM at FMS
All as ditto as per item No : 42 here in before but 5500 CFM at AHU No 2, AHU No 3 & AHU No 5 in FMS
All as ditto as per item No : 42 here in before but 3800 CFM at FMS
Supply only refrigeration gas R 22 in manufacturer sealed cylinder. NOTE:- (i) Gas to be supplied in manufacturer sealed container. (ii) Empty containers will be returned to contractor .
Attending compliants of central/package AC of any capacity, rectification of minor deffects and complaints replacement of spare parts and brings to normal working condition all as per directed and specified by Engr-in-charge. Note :- Major spare parts measured and paid separately
S & F in replacement of Single Phase Preventer suitable for up to 30Hp motor starter all as specified & directed. Make: Minic
Supply & fix replacement of current transformer 100/5 Amps ratio at main panel all as specified & directed.
Supply & fix replacement of ammeter with ratio of 100/5 Amps & all as specified & directed.
Supply and Fixing in replacement of Air cooled condensor out door type with tank and copper tube for discharge line unit assembly including all connected items capacity 5 to 10 TR all as specified and directed Make: Blue star
M&L Providing insulation on and around suction and discharge copper tube of size 3/8"/ 5/8" with 6mm thick flexible thermocol heat resistance duly wrapped with sticking tape and finally covered with flexible PVC conduit of 50mm bore complete including taking down existing damaged one all as specified and as directed.
Supply and fix in repair Blower fan motor 3 phase 750 W suitable for AC plant 1 x 10 to 1x 15TR capacity at signal section of existing make/ brand of defective components or any reputed suitable make as approved by the Engineer-in-Charge.
Supply and fix in repair AHU Blower motor with blower set of existing make suitable for the 3X15 TR precision type AC plant at various location complete all as specified and as directed.
Taking down old unserviceable scroll type compressor of capacity 10 to 12 TR including supply and replacement of same capacity of compressor of Make Emerson Climate Technologies or equivalent make for AC plant at location : TRCL
Dismantling existing damaged ducts and Supply, assembly and erection of 24 gauge GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, hanging rod, Gasket and appropriate sealant on longitudinal joints etc complete all as specified and as directed.
M&L in repairs duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation suitable for 40 mm as specified and including the following:- (a)Cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (c) Sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
S&F in replacement of grills/diffusers of size 630X630 mm for supply air duct made out of CRCA sheet 1.2mm thick, with perforation duly powder coated etc adjustable type(with flow regulating arrangement) all as directed.Make : Microflow ,3C Air Equipments, Deepak cooling control.
Supply and fix in replacement of Galvanised steel, volume control damper/parallel Blade Dampers for rough air system balance with closer control at the individual grills or diffusers for supply air complete all as specified and as directed. Make : Microflow, 3C Air Equipments, Deepak cooling control.
Taking down old unserviceable outdoor condenser coil from existing unit and Supply and fix new outdoor condenser coil of same Model suitable for the AC plant 5 TR to 12 TR complete all as specified and as directed.
Supply and fix in repair condenser fan motor unit of outdoor of AC plant 1 x 12 TR capacity at complete all as specified and as directed.
Supply and fix in repair condenser fan motor unit of outdoor unit of AC plant 1 x 13 TR capacity at block complete all as specified and as directed.
Supply and fix in repair condenser fan motor unit of outdoor unit of AC plant 1 x 10 TR capacity at block complete all as specified and as directed.
Supply and fix in repair condenser fan motor unit of outdoor unit of AC plant 1 x 5TR capacity at complete all as specified and as directed.
Supply and fix in repair condenser fan motor unit of outdoor unit of AC plant 3 x 16.5 TR capacity at transmitter complete all as specified and as directed.
Supply and fix in repair condenser fan motor unit of outdoor unit of AC plant 1 x 15 TR capacity at CRRW/ SEW of existing make/ brand of defective components or any reputed suitable make as approved by the Engineer-in-Charge.
Supply and fix in repair condenser fan motor unit of outdoor unit of AC plant 2 x 7.5 TR capacity at TRCL complete all as specified and as directed.
Supply and fix in replacement of contactor 3 Phase 415 Volt suitable for AC plant of capacity 3 x 16.5 TR at Opera-I complete all as specified and as directed.
S&F water pressure cut out 230 volt including taking down existing one complete all as specified and as directed. Make Indfoss or equivalent.
Supply and fix in repair Blower fan motor suitable for AC plant 1 x 8.75 TR at T-51 of existing make/ brand of defective components or any reputed suitable make as approved by the Engineer-in-Charge.
S&F in repair strainer of package type ac plant of capacity 1 x 12TR with ISI mark complete all as specified and as directed.
Supply and fix in replacement of contactor 3 Phase 415 Volt suitable for AC plant of capacity 3X45TR at Rotable Div and 2 x 7.5 TR at TRCL complete all as specified and as directed. Make-Siemens, ABB, Schneider, L&T.
Supply only Refrigerant gas R – 407 C as and when required for AC plants of various capacity following capacity complete all as specified and as directed:-
Taking down unserviceable MCCB, supply and fixing MCCB 63 Amps 16 KA 4 pole 415Volts including connection using suitable size of aluminium lugs complete all as specified and as directed. Make : L&T, ABB, Schneider
Taking down unserviceable MCCB, supply and fixing MCCB 100 Amps 25 KA 4 pole 415Volts including connection using suitable size of aluminium lugs complete all as specified and as directed. Make : L&T, ABB, Schneider
Taking down unserviceable MCCB, supply and fixing MCCB 125 amps 25 KA 4 pole 415Volts including connection using suitable size of aluminium lugs complete all as specified and as directed. Make : L&T, ABB, Schneider
M&L for takingdown of unsv FRP tank from existing cooling tower by dismantaling of fan hub assembly. Finns, water nozels . Chiller pump. Gate valves and base from than Supply, errection & fixing of FRP cooling tower size/capacity suitable for 60 TR with new finns and nozeels including water pump connections all as specified and directed by Engr-in-Charge.
M&L for takingdown of unsv FRP tank from existing cooling tower by dismantaling of fan hub assembly. Finns, water nozels . Chiller pump. Gate valves and base from than Supply, errection & fixing of FRP cooling tower size/capacity suitable for 30 TR with new finns and nozeels including water pump connections all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of fan hub assembly suitable for 60 TR capacity cooling tower with proper nut bolt and fixing all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement of fan hub assembly suitable for 30 TR capacity cooling tower with proper nut bolt and fixing all as specified and directed by Engr-In-Charge.
p.chinnasamy (BID ID -3357686)
PRIYA ENTERPRISES (BID ID -3355718)
ANAND REFRIGERATION (BID ID -3357414)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .