| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹17.1 L+₹1.7 L (11.3%)Rejected-Finance BANK COLONY MATHASAHI MOTIGANJ BALASORE BALASORE ODISHA 756003 | BALESHWAR | ODISHA | 756003 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹17.7 L+₹2.4 L (15.5%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹18.4 L+₹3.1 L (20.1%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹18.8 L+₹3.5 L (22.7%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Chandipur
GE I R and D Chandipur, Post- Chandipur, PIN-756025
CERTAIN REPAIR TO CENTRAL AND PACKAGE TYPE AIRCONDITIONING PLANTS AT PXE TECH AREA CHANDIPUR
2021_MES_428341_1
8608/CDP
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandipur
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE I R and D Chandipur
₹30,000
Yes
30 Mar 2021
5 Mar 2021
25 Mar 2021
5 Mar 2021
24 Mar 2021
19 Mar 2021
60 days
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
Disconnection and taking out unserviceable electric motor of capacity 20 HP from compressor unit, 3 pahse, 415 volts of any make and type, Transportation to out side workshop for necessary repair/rewinding, dismantling of complete motor assembly, taking out burnt winding cleaning of core and rewiding with supper enamel copper wire of appropriate gauge/size and weight /turn as per existing including providing insulation materials, varnising , heating all as directed, repalcement of worn out bearings and carrying out painting by two coats of (1st quality) synthetic enameled paint over the existing painted surface after preparation, transporting the repaired compressor motor to the installation refixing to its original position with compressor through belt and pully with proper alignment, testing and commissioning comprete all as directed.
All as per Item No. 1 here-in-before but for 15 HP motor, 3 phase, 415 Volts.
All as per Item No. 1 here-in-before but for 10 HP motor, 3 phase , 415 Volts.
All as per Item No. 1 here-in-before but for 7.5 HP motor, 3 phase , 415 Volts.
All as per Item No. 1 here-in-before but for 3 HP motor, 3 phase, 415 Volts.
All as per Item No. 1 here-in-before but for 0.75 HP motor, 3 phase, 415 Volts.
Dismantling and taking down electric motor assembly and transporting to workshop and carry out servicing / maintenance of motor unit of capacity 60 HP including following works :- (a) Opening of electric motor and cleaning / remvoing dust from armature and field coil. (b) Cleaning of used / old lubricated substances drive/non drive end bearings. (c) Cleaning and checking of stator/rotor unit. (d) Checking and tightening of coupling bolts and replacement of rubber inserts. (e) M&L for carrying out heat varnishing with varnish solution of best quality for field and armature coil and kept in heating chamber for 48 hours for drying properly. (f) Reassembling complete motor and carrying out testing at workshop and transportation to installation and coupling with compressor/pumping set including necessary alignment, cable connections all as specified and directed. (g) M&L for replacement of bearings. (h) M&L greasing and replacement of rubber coupling.
All as per Item No.7 here-in-before but for cpacity of electric motor 20 HP.
All as per Item No.7 here-in-before but for cpacity of electric motor 15 HP.
All as per Item No 7 here-in-before but for cpacity of electric motor 7.5 HP.
All as per Item No 7 here-in-before but for cpacity of electric motor 3 HP.
Dismantling the monoblock pump of capacity 10 HP including disconnecting inlet,out let connections and machining gland cap etc. replacing worn out ball bearing,impeller, filling of gland packing, Fan Cover,greasing and reassembling the pump at its original location including connections testing all as specified and directed by Engr-in-charge.
All as per Item No.12 here-in-before but for pump of capacity 7.5 HP.
Carrying out cleaning and descaling of iron deposited in inside and outside of condenser shell and tube by using acid solution or other chemical recommended by manufacturer manual of the respective plant, complete with satisfactory of capacity 1 x 40 TR Central AC Plant at Auditorium as specifed and directed by Engineer-in- Charge. Note : All equipments & Chemical has to be arranged by Contractor. No extra charge has to be provided by the Department.
All as per Item No.14 here-in-before but for capacity 1 x 85 TR at Ballistic Centre AC Plant.
Supply and Replacement of Micro filter / Cadillac Air Filter of sizes 608 mm x 608 mm x 50 mm with taking out old unserviceable Air Filter with repair/replacement of rusted and wornout GI chanels for properly holding/fixing of micro filters all as specified and directed . Note:-Repair/replacement cost of GI chanels will be included in unit rates.
Supply and Replacement of Micro filter / Cadillac Air Filter of sizes 630 mm x 508 mm x 50 mm with taking out old unserviceable Air Filter with repair/replacement of rusted and wornout GI chanels for properly holding/fixing of micro filters all as specified and directed . Note:-Repair/replacement cost of GI chanels will be included in unit rates.
Supply and Replacement of Pre- Micro filter / Cadillac Air Filter of sizes 508 mm x 508 mm x 50 mm with taking out old unserviceable Air Filter with repair/replacement of rusted and wornout GI chanels for properly holding/fixing of micro filters all as specified and directed . Note:-Repair/replacement cost of GI chanels will be included in unit rates.
Taking down unserviceable outdoor unit and supply and replacement of Fin and tube type Condenser of 5.0 TR capacity,air cooled package type AC.plant Condensing Unit including necessary repair/fabrication of base plate and connection all as specified and directed.
Taking down defective screw type compressor unit of capacity 85 TR ( Make- Carrier ),Central type AC plant at Ballastic Centre and carry out the following repair/Replacement of compressor oil,Drier core filter,internal/External oil filter, Packing Gaskets with other necessary repair works and re-assemble at its original position and testing all as directed. Note:- The spare parts to be measured and paid separately under Supply only items.
Supply only Screw Compressor Oil including taking down, Make- Carrier,Cat part No-2000988.
Supply only Drier core/ filter including taking down, Make- Carrier,Cat part No-2000797
Supply only Internal oil filter including taking down, Make- Carrier,Cat part No-2001972
Supply only External oil filter including taking down, Make- Carrier,Cat part No-2000144
M & L for Carry out Painting of Chiller Compressor unit, Compressor motor and structure by rubbing and cleaning of rusted area complete including with Condenser, water pipe line and Chiller pipe lines on outer surface of Central Chiller type AC plant of cap 3x40TR / 3x 85 TR with two coats of synthetic enamel paint all as specified and directed.
M & L for Carry out Painting of AHU unit of Central Chiller type AC plant of cap 40 TR/85 TRby rubbing and cleaning of rusted area including exposed duct lines inside the AHU Room, with two coats of synthetic enamel paint all as specified and directed.
M & L for Carry out Painting of Outdoor unit/Condensing unit both outer and inner surface of Package AC plant of cap 17 TR by rubbing and cleaning of rusted area with two coats of synthetic enamel paint all as specified and directed.
M & L for Carry out Painting of both outer and inner surface of Package AC plant of cap 10 TR by rubbing and cleaning of rusted area with two coats of synthetic enamel paint over one coat of primer all as specified and directed.
Supply & charging of Refrigerant (R-22) in AC plant at Auditorium, Ext. AP Lab with detecting the leak in the whole system by charging Nitrogen gas and vaccumize the same for proper leak proofing the unit and charging of adiquete antimoist in the system all as specified and directed. Make : Mafron/Floron/Refron. Note:- Quantity of Nitrogen gas used for leak testing and Antimoist for absorbing of moisture are included in the unit rates
Supply & charging of Refrigerant (R-407) in AC plant at Ayudh Bhawan & AP Lab . with detecting the leak in the whole system by charging Nitrogen gas and vaccumize the same for proper leak proofing the unit and charging of adiquete antimoist in the system all as specified and directed. Make : Mafron/Floron/Refron. Note:- Quantity of Nitrogen gas used for leak testing and Antimoist for absorbing of moisture are included in the unit rates
Supply & charging of Refrigerant ((R-134) in the AC plant at Ballistic Cente with detecting the leak in the whole system by charging Nitrogen gas and vaccumize the same for proper leak proofing the unit and charging of adiquete antimoist in the system all as specified and directed. Make : Mafron/Floron/Refron. Note:- Quantity of Nitrogen gas used for leak testing and Antimoist for absorbing of moisture are included in the unit rates
Supply&Replacement of Switch disconnector fuse unit open exicution type with 3 Nos rated HRC fuse for rated current 415 Volt TPN 200 Amps including taking down. Make : L&T/ Siemens
Supply&Replacement of 'V' Belt of size B-55 including taking down. Make :Fenner / Dunlop /Sonal/PIX
Supply & Replacement of 'V' Belt of size B-66 including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply & Replacement of 'V' Belt of size B-72 including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply & Replacement of' V' Belt of size A-32 including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply & Replacement of 'V' Belt of size SPA - 850 LdEL including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply & Replacement of HRC Fuse link type (HF) of capacity 32 Amps,415 volts including taking down. Make : C&S, Havells, L&T
Supply & Replacement of HRC Fuse link type (HF) of capacity 63 Amps,415 volts including taking down. Make : L&T/C&S, Havells,
Taking out old unserviceable Shaft bearings of AHU (Air handling unit), replace with new one as per existing size & shape and refix at its origional position with proper alignment of complete AHU unit at ballistic centre AC Plant of cap 85 TR complete all as specified and directed by Engr-in-Charge.
Supply only Air break power contactor of 3TS 3300.0A.8K Ac 3 , 415 V, 50 Hz. Make - Siemens or Equivalent as directed by Engineer - in - Charge.
Supply only Air break power contactor of 3TS 3110.0A.8K Ac 3 , 415 V, 50 Hz. Make - Siemens or Euivalent as directed by Engineer - in - Charge .
Supply only Air break power contactor of 4 way, 3TF 3010.0A.8K , Le/ac 1 -20 Amps, Le/Ac - 3 - 9 Amps , 415 V. Make - Siemens or Euivalent as directed by Engineer - in - Charge .
Supply only Power contactor of 3 pole 3 way, 3TF 3200.0A.8K Ac 3 , 415 V, 50 Hz , Coil Voltage - 220V, Le/Ac 01- 3 Amps, Le/Ac - 3 - 16 Amps. Make - Siemens or Euivalent as directed by Engineer - in - Charge .
Supply only Auxilary Contact 3TX 4010-02-01 NO, Make - Siemens or Equivalent as directed by Engr - in - Charge.
Supply only Auxilary Contact 3TX 4001-2A-01 NC, Make - Siemens or Equivalent as directed by Engr - in - Charge.
Supply only Over Load Relay 3UW5002-1F, Range 3.2 - 5 Amps, Maximum Fuse rating for main circuit- 16 Amps, Make - Siemens or Euivalent as directed by Engr - in - Charge.
Supply and Replacing of Microprocessing Unit of Package unit of capacity 17.0 TR at Ayudh Bhawan/ A.P.Lab AC plant, PXE.Chandipur including taking down old U/S.PCB.
Supply only power Contactor MNX - 12, Coil Voltage 240V with Add on Block MNX - A upto 415V, 50 - 60 Hz. Cat No - CS94108. Make - L&T / Standard/C&S.
Supply only 3 Pole Power Contactor MNX - 18, Coil Voltage 240V with Add on Block MNX - A upto 415V, 50 - 60 Hz. Cat No - CS94100. Make - L&T / Standard/C&S.
Supply only 3 Pole Power Contactor MNX - 25, Coil Voltage 240V with Add on Block MNX - A upto 415V, 50 - 60 Hz. Cat No - CS94110. Make - L&T / Standard/C&S.
Supply & Replacement of Square size Digital type Volt meter Size-95x95 mm ,0 to 480 VAC . Cat No - DM 1210 of Schneider or Equivalent of L&T/Standard
Supply & Replacement of Square size Digital type Ampere meter Size-95x95 mm ,0-500 Amp . Cat No - DM 1110 of Schneider or Equivalent of L&T/Standard
S&F Oil seal and "O ring" of shaft of 40TR cap Voltas make compressor including taking down. Cat Part No-050465 of Make:- Voltas
Taking out old unserviceable Shaft bearings of AHU(Air handling unit), replace with new one as per existing size & shape and refix at its origional position with proper alignment of complete AHU unit of 40 TR AC plant cap all as specified and directed by Engr-in-Charge.
Repair /Replacement of Outdoor unit Fan motor stand made of MS plate of existing size and gauge including necessary nuts,bolts and washers complete with anti corrision painting suitable for air cooled condensing unit of package AC plant of cap 17.0 TR including taking down old Unserviceable stand all as specified and directed
S&F switch disconnector fuse unit open exicution type with 3 Nos rated HRC fuse for rated current 415 Volt,50 Hz, TPN 32 Amps including taking down. Make : Standard/Havells/ L&T/ C & S.
S&F of 8 way connector 60 Amps,600 volts including taking down, Make:- Nipun/Standard/C&S.
S&F of 12 way connector 60 Amps,600 volts including taking down, Make:- Nipun/Standard/C&S.
Supply and filling compressor oil in compressor with sealed container including drain out old unserviceable compressoir oil. (Make - Freezal 68 / Vidol 68)
M&L for Taking down cooling tower fan motor assembly for repair/replacement of components, repairing the damage cooling tower body at certain portion made with FRP sheet by replacing new FRP sheet and replacing all rusted jointing nuts, bolts complete and refixing on original position, testing complete all as directed by Engr – in - Charge.Model No- CM-6 of central AC Plant of cap 40 TR. Note :- Cost of components shall be measured and paid separately.
Supply only PVC Sill Fills 600 mm x 300 mm x 150 mm
M & L for Fabrication of Holder for the PVC Fills.
Supply only PVC Nozzles for Cooling Tower
Supply only Fan Blade for Cooling Tower fan motor.
Supply and fixing of Danfos make Scroll Compressor 8.5TR, 3 phase 415V icluding Gas Charging , Vacuumisation, leak Testing etc complete all as directed.
Supply and replacement of Start/Stop button push switch 23 Amps,3 phase of package type AC plant panel board with taking down old one all as per existing and specified and directed.Make - L&T / Standard/BCH
Supply and replacement of Butterfly valve of size 150mm dia pipe with taking down old one all as specified and directed
M&L, in replacement, Water pressure gauge 0-7 kg/cm.sq to be fitted on water pipe line.
Repair/Maintenance of LT indoor type Panel board of AC plant of capacity 3x85 TR with repair/replacement of necessary Unserviceable Spare parts like Overload relay,Contactor etc with taking down old unserviceable spare parts. Carry out Painting of both outer and inner surface of Panel after rubbing and cleaning of rusted area, with two coats of synthetic enamel paint over one coat of primer all as specified and directed . Note:-spare parts will be measured and paid separately in specified items and materials like screws,nuts,bolts,washers,link clips,terminal clips, insulation Tape etc will be included in unit rates.
Repair/Maintenance of LT Indoor type Panel board of AC plant of capacity 3x40 TR with repair/replacement of necessary Unserviceable Spare parts like Overload relay,Contactor etc with taking down old unserviceable spare parts. Carry out Painting of both outer and inner surface of Panel after rubbing and cleaning of rusted area with two coats of synthetic enamel paint over one coat of primer all as specified and directed . Note:-New spare parts will be measured and paid separately in specified items and materials like screws,nuts,bolts,washers,link clips,terminal clips, insulation Tape etc will be included in unit rates.
Repair/Maintenance of LT Indoor type Panel board of AC plant of capacity 3x10TR with repair/replacement of necessary Unserviceable Spare parts like Overload relay,Contactor etc with taking down old unserviceable spare parts. Carry out Painting of both outer and inner surface of Panel after rubbing and cleaning of rusted area with two coats of synthetic enamel paint over one coat of primer all as specified and directed . Note:-New spare parts will be measured and paid separately in specified items and materials like screws,nuts,bolts,washers,link clips,terminal clips, insulation Tape etc will be included in unit rates.
Repair /Maintenance of LT Indoor type Panel board of AC plant of capacity 3x17 TR with repair/replacement of necessary Unserviceable Spare parts like, overload relay,Contactor etc with taking down old unserviceable spare parts. Carry out Painting of both outer and inner surface of Panel rubbing and cleaning of rusted area with two coats of synthetic enamel paint over one coat of primer all as specified and directed . Note:-New spare parts will be measured and paid separately in specified items and materials like screws,nuts,bolts,washers,link clips,terminal clips, insulation Tape etc will be included in unit rates.
Repair /Maintenance of LT Indoor type Panel board of DG Set of capacity 160 KVA with repair/replacement of necessary Unserviceable Spare parts like MCCB,Overload relay,Contactor etc with taking down old unserviceable spare parts. Carry out Painting of both outer and inner surface of Panel rubbing and cleaning of rusted area with two coats of synthetic enamel paint over one coat of primer all as specified and directed . Note:-New spare parts will be measured and paid separately in specified items and materials like screws,nuts,bolts,washers,link clips,terminal clips, insulation Tape etc will be included in unit rates.
Repair /Replacement of Outdoor unit Fan motor stand made of MS plate of existing size and gauge including necessary nuts,bolts and washers complete with anti corrision painting suitable for air cooled condensing unit of package AC plant of cap 17.5 TR .
Supply and replacement of Oil pump of screw compressor ,LS-159000,Level Switch-20-VAP/N HR-12BA--011-EE,GEMS-P/N166570 with GEMS Sensors all as specified and directed. Make-Carrier
Supply and replacement of Digital type Display board for Package AC plant with senssor all as specified and directed by Engr-in-Charge.
Supply and replacement of Solinoid valve ,CE type ASC,24 volts,50-60Hz ,18 VA ,ED-100%,IP 65 with connecting cable and necessary connections all as specified and directed,Make/model-VDE 0580 of ALCO CONTROLS/ CARRIER or equivalent.
Supply and replacement of Water Pressure Switch for Chiller water with senssor all as specified and directedby Engr-in-Charge.
M/SNeelachal Enterprises
KRISHNA ENTERPRISES
M/s R.C REFRIGERATION
ELECTRO COMMERCIAL CO
jlenterprise
Shree Mahavir Associates
chauhan syndicate
Bidder Name
DS ENTERPRISES
KRISHNA ENTERPRISES
M/s R.C REFRIGERATION
Shree Mahavir Associates
chauhan syndicate
ELECTRO COMMERCIAL CO
M/SNeelachal Enterprises
jlenterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .