Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-Finance G 2 BIDHAN NAGAR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L1 | Accepted-Finance ok | |
| 2 | L2₹13.0 L+₹63,954 (5.18%)Rejected-Finance | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹13.7 L+₹1.3 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹13.9 L+₹1.6 L (12.6%)Rejected-Finance | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹14.9 L+₹2.6 L (20.8%)Rejected-Finance 2 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
10 May 2022, 1:00 pmClosed
Executive Engineer Paschim Med. Elecl. Div. PWDte
Office of the Executive Engineer, Paschim Medinipur Electrical Division, P.W.Dte. Paschim Medinipur.
Special repairing of the E.I. work for renovation of Female surgical and Female Medicine ward at Kharagpur SDH, Paschim Medinipur.
2022_WBPWD_377154_1
WBPWD/EE/PMED/NIQ-04/e-Q /2022-2023
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
kharagpur, Paschim Medinipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,000
17 May 2022
19 Apr 2022
12 May 2022
19 Apr 2022
10 May 2022
27 Apr 2022
Amount
Dismantling the existing wiring, Light fitting with all allied accessories carefully & submitted to the concern section office/ authority and providing temporary arrangement as par direction of E.I.C.
Supplying and fixing 415V FP 63A Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make- Havells/ L&T )
S & Delivery of following size 1.1kv grade xlpe insulated Al/A cable. (Make- Policab/ havells/ Gloster/ KEI)
a) 4 Core 95 sqmm XLPE Al/ armoured cable. (Feeder piller to existing femail surgical ward LT panel)
b) 4 Core 35 sqmm XLPE Al/ armoured cable.
c) 4 Core 16 sqmm XLPE Al/ armoured cable. (For emergency power backup for Pump Room)
d) 2 Core 6 sqmm XLPE Al/ armoured cable. (for sequrity light control)
Laying of following armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
a) 4 Core 95 sqmm XLPE Al/ armoured cable.
b) 4 Core 16 sqmm XLPE/PVC armoured cable
c) 2 Core 6 sqmm XLPE Al/ armoured cable.
Supplying & fixing of following dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
a) 50 mm dia
b) 32mm dia
Laying of following 1.1kv grade XLPE insulated AL/A cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
a) 4 Core 35 sqmm XLPE armoured cable.
b) 4 Core 16 sqmm XLPE Al/ armoured cable.
c) 2 Core 6 sqmm XLPE Al/ armoured cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables for following XLPE/PVC armoured cable.
a) 4 Core 95 sqmm XLPE/PVC armoured cable.
b) 4 Core 35 sqmm XLPE/PVC armoured cable
c) 4 Core 16 sqmm XLPE Al/ armoured cable.
d) 2 Core 6 sqmm XLPE Al/ armoured cable.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
a) 4 Core 95 sqmm XLPE/PVC armoured cable.
b) 4 Core 35 sqmm XLPE/PVC armoured cable
c) 4 Core 16 sqmm XLPE Al/ armoured cable.
d) 2 Core 6 sqmm XLPE Al/ armoured cable.
Supplying and fixing double door 6 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING :- Supplying and fixing 415V 80A FP MCB Isolator on din rail of existing DBs and necessary connection - 1 No. OUTGOING :- Supplying and fixing 240V, 16A/32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection- 18 Nos. (Make: Siemens (8GB32202RC06)/ Schneider/ Legrand)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
a) 20mm dia
b) 25mm dia
Cutting Channel of size (40 mm x 40 mm/ 43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge following size Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire
b) 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes incl. S& F bakelite / perspex top cover by Brass screws, flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works.
a) 100 mm x 100 mm x 65 mm.
b) 150 mm x 100 mm x 65 mm.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- Finolex/ Policab/ Havells/ RR kabel/ KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
a) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (from TPNDB to SPNDB)
b) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC (for1ph ac machine/ )
c) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC(for 15A power plug,computer board& Power board)
d) 3 x 22/0.3 (1.5 sqmm) ( 2X5A & Gr control)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2.5sqmm
b) 4sqmm
c) 6sqmm
Supplying and fixing 250 V, 6-10A per way, (2+12)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP MCB Type Isolator, 12 no. 6-16A SPMCB) (Make: Siemens (8GB32102RC14)/ Schneider/ Legrand)
Supplying and fixing 250 V, 6-10A per way, (2+8)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP MCB Type Isolator, 8 no. 6-16A SPMCB) (Make: Siemens (8GB32102RC10)/ Schneider/ Legrand)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- Finolex/ Policab/ Havells/ RR kabel/ KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 8 mtr
Average run 10 mtr
Average run 12 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. On board.
Supply & Fixing 240 V, 2 nos. 6A plug socket with separate 2 nos. 6 A Piano key type switch, on sheet metal switch board embedded in wall incl. S & F 175x100x65mm size MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 1 nos. 20A plug socket & 1no 6A socket with separate 1 nos. 20 A & 1 no 6A Piano key type switch, on sheet metal switch board embedded in wall incl. S & F 200x150x65mm size MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 1 nos. 20 A Piano key type switch, on sheet metal switch board embedded in wall incl. S & F 100x100x65mm size MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (for controlling compound light)
Supply & Fixing 240 V, 25 A, Modular type starter (Make- Schneider/ Legrand/ Crabtree) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make- Schneider/ Legrand/ Crabtree), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make- Schneider/ Legrand/ Crabtree) & necy. Connections.
Supplying & Fixing sintex make PVC waterproof type 1 phase looping cable box conceal/ surface on wall size 200x150x100 mm deep having one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, incl. earthing attachment.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
S&F of 230v following size A.C. ceiling fan complete with blades, canopy, fork, rubber, bush etc. including S&F connecting wire for down rod up to 30cm including painting the rod with approved paint and making necessary connection as required.(Make -Orient- summer breeze/ Crompton- high speed)
a) 1400 mm sweep
S&F following heavy duty industrial type exhaust fan with louver shutter heavy gauge to be fixed on wall with necessary cutting of wall etc. and mending good the damages.(Make- EPC, Heavy duty).
S & F 250 V 50 HZ 18" (450 mm) high flo oscillating type metal body Wall Bracket fan operated by pull cord switch with inbuilt regulator (Make -Orient, model- Tornado Wall-II/ Crompton)
Fixing single/twin 4' LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. incl. s&f 1200mm 22W master LED tube.
Supply & Delivery of single LED tube fittings (Make- Havells, cat no- REGALBATTENT8UPTO1X22WSSBSWH incl. 1 nos. LED tube cat no-PHOTONULTRAE2.01213T8SSTL20WLED865SPC/ Wipro/ Philips.)
Supply & Delivery of twin LED tube fittings (Make- Havells, cat no- REGALBATTENT8UPTO2X22WSSBSWH incl. 2 nos. LED tube cat no-PHOTONULTRAE2.01213T8SSTL20WLED865SPC/ Wipro/ Philips.)
S & F of 1200mm 22W master LED tube. With fixing on existing fittings incl necessary connection as require. (Havells, cat no- -PHOTONULTRAE2.01213T8SSTL20WLED865SPC/ Wipro/ Philips.)
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
S & F of following LED surface mounted downlight with ABS housing & PC Opal diffuser with integral electronic LED driver ( for hospital corridor portion)
Make Havells cat no-GLOWDLS15WLED830S / Wipro/ Philips.
Make Havells cat no-GLOWGENXDLS18WLED857S / Wipro/ Philips.
Supply & Fixing of following outdoor LED light fitting complete with all accessories to be fixed/projected from the wall of the building/existing pole incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting.
Make- havells cat no- ENDURAOMNIPLUSSL110WLED757SASYTOPC// Wipro/ Philips.) for main gate entry , Emergency & for security light of Hybrid CCU DG location)
(make havells cat no-ENDURAOMNIPLUSSL90WLED757SASYTOPC// Wipro/ Philips.) for security light of back side of Hybrid CCU
S&F following length down rod (14 SWG) for celing fan fixing & necy. PVC insulated wire and painting etc. as required by 2 x 22/0.3 (1.5 sqmm) stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC).
Supply & Fixing 9W LED lamp on existing holder point. (Make- Philips/ Bajaj/ Crompton/ Havells)
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supply & Delivery of Concealed split Room Air Conditioner 2.0 Ton capacity having the following specification : Compressor Type: Rotary, Rated Cooling Capacity (Watts): 7032, Rated Power supply: 230V, 50Hz, Air volume for indoor unit(CFM): 800, Nano Platium filter, powerful cool and wide & long airflow Air Sleep Cooling Technology, LCD remote control, Electronic metal housing box, 12 hour on and off timer, auto restart, Refrigerant-R410A. [Make- Hitachi, model no- Hitachi Wired Pac Concealed or eqv. make of Carrier/ Daikin/ Mitsubshi Electric.
Supply & Delivery of (I) Electric cable (II) Copper pipe 3/8" / 1/2" for liquid as required (III) Copper pipe 5/8" / 1/4" for suction as required (IV) Insulation foam 3/8" / 1/2" for liquid as required (V) 5/8" / 1/4" for suction as required (VI) Drain pipe of PVC for dranage connection installation of split A.C. both indoor and outdoor unit
Installation of Concealed Split type Room Air Conditioner by fixing out-door unit on MS angle iron frame made of 40x40x6mm. angle & intermediate with 25x6 mm. flat grouted on wall/roof and in-door unit with suitable fixing arrangement and painting.
Taken down the existing AC celing fan and refixing the same after Washing, cleaning the fans complete with blade, canopy, down rod etc by soap water solution as to G.S.
Opening the fans part by part, cleaning the same by kerosene oil and greasing properly as require
S & F fan jum nut &split pin etc.
Bobin insulator
Fan condencer ( 2.5 mf)
S & F additional safety arrangement of ceiling fan by stranded GI strain wire of suitable guage with one end fixed at RC clamp with special type socket/nut bolts thimble which throughly crimped with the strain wire and the wire passing through down rod and also other end connected with armature spindle by its exsisting jam nut hole with special arrangement ( approved by EIC ). The langth of the strain wire as mention below also considering any type of work required i.e. enlarging the existing hole by file etc. to complete the job incl. installation as per direction of EIC. 6" to 48"
S & F of Glow sign board rectangular in safe by angle irin structure having 10'x3'x6" deep to be fabricated by 40x40x6 mm thick MS angle with MS flat by 25x6mm as supporting. The structure to be enclosed by ai sheet of 20SWG as per requre. The front to be covered by facia unbreakable poly carbon having 2.5 mm thick. This shall be pasted computarised with opted matter as recommended by the authority concerned. The facia should be fixed by 1"x1" heavy guage al angle/channel as reqd incl. s&f by 6x 20W LED tube light fittings (Make- Havells/ Philips/ Wipro) incl. necessary connection. Painting should be done as per GS in three side of the board. The back side should be of three pieces hinged type door fixed with railway type locking arrangement. Internal circuit wiring by 3x1.5sqmm cu wire and 6aDPMCB fixed on DIN rail in the housing of the glow sign board (at Emergency)
The Glow Sign board is t be fixed on roof making PCC works dully plastered and net cemented by two places providing two nos 40x40x6mm thick 5' long vertical supports and 40x40x6mm thick 6' long two nos diagonal supports, base plates dully grouted by PCC works plastered and net cemented.
S &L of 3x 1.5 sqmm pvc cu wire through polythine pipe concealed in wall as to GS from existing loop box to Glow Sign Board.
Feeder Pillar Box for TPN SFU:- Supply & Erectioning Outdoor type Feeder Pillar Box made of 3.15 mm thick CRCA Sheet with Trapezoidal top cover ( 5 mm thick ) for accomodating 1 no. 415V, 315A TPN SFU with Sheet Steel enclosure( 315A SFU should be supplied by the department), The piller box having hinged type one side door with locking arrangement. It will erected on 20 " brick foundation(Above GL) finished with neat cement plaster, Piller box should have 2 ( Two) coat of enamel paint powder coated over RO Primer with mechaical locking arrangement,
Connecting the equipments to earth busbar including S & F GI (Hot Dip) 4 SWG wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
NAYEE DISHA PROJECTS
KORUNAMOYEE ENTERPRISE
ROY CHOWDHURY AND CO
MAHESWAR ELECTRICAL INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .