| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L1 | Accepted-AOC QUOTED AMOUNT IS REASONABLE | |
| 2 | L2₹50.3 L+₹1.9 L (4.01%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹53.6 L+₹5.2 L (10.8%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹58.5 L+₹10.1 L (20.8%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹59.0 L+₹10.6 L (21.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | SANJEEV ENTERPRISES L2 | RUCHIKA ENGG.WORKS L4 | Singh Associates L3 | Iconic Engineers L5 | Saini Enterprises L1 | Flint India L6 | M P TYAGI ENGINEERS AND CONTRACTORS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling compressor of central AC plant for overhauling complete with connected copper pipe line and loading unloading mechanism & pump down the existing refrigerant in separate cylinder, disconnecting of electric motor of compressor, refrigerant line, gauges pipe and carry out the general over hauling of compressor, compressor model:- SMC/4/100, Make:- Accel (R-22) including replacement of springs, aluminium washer packing, screw, lath work, cleaning detergent, cotton waste, changing of compressor oil etc and cleaning the suction filter, oil filter, replacing the defective parts compete system for safe guard the gas with self pumping down system or with total recovery unit system incld. following operation complete all as specified & directed.
(i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure/ leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any.
(ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any.
(iii) Charging of complete system with R-22 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi....
(iv) Measure the inlet and outdoor temperature of Chiller unit for performance checking and maintaining temp. as per require site.
(v) Testing & commissioning of compressor after completion. Note:-
(a) Spares of compressor shall be measured and paid separetely under respective item of this schedule (Sr No. 1.01 to 1.19).
(b) Any minor items required for overhauling except described here-in-after shall be supplied by the contractor with out any extra cost to the deptt and the rates for the same shall deemed to be included in the quoted rates. | 6 | Each Job | 20,000 ₹1,20,000 | 15,000 ₹90,000 | 10,000 ₹60,000 | 5,000 ₹30,000 Lowest | 18,000 ₹1,08,000 | 20,000 ₹1,20,000 | 2,99,999 ₹17,99,994 |
| 1.01 | Supply only in replacement PISTON with PIN & Rings- 04 Nos (ACCEL Part No. ASL1018R) complete all as specified and directed. SMC/4/100, | 6 | Each set | 4,000 ₹24,000 | 3,200 ₹19,200 | 2,200 ₹13,200 | 1,600 ₹9,600 Lowest | 3,000 ₹18,000 | 2,225 ₹13,350 | 4,999 ₹29,994 |
| 1.02 | Supply only in replacement cylinder with suction valve -04 Nos(R-22) (ACCEL Part No. ASL1019A) complete all as specified and directed. SMC/4/100, | 6 | Each set | 3,000 ₹18,000 | 4,500 ₹27,000 | 1,450 ₹8,700 Lowest | 6,400 ₹38,400 | 2,000 ₹12,000 | 7,363 ₹44,178 | 4,999 ₹29,994 |
| 1.03 | Supply only in replacement OIL pump (ACCEL Part No. ASL1011A) complete all as specified and directed. SMC/4/100, | 2 | Each | 7,500 ₹15,000 | 11,000 ₹22,000 | 1,350 ₹2,700 Lowest | 5,300 ₹10,600 | 4,000 ₹8,000 | 7,976 ₹15,952 | 4,999 ₹9,998 |
| 1.04 | Supply only in replacement Discharge valve assembly (R-22) (ACCEL Part No. ASL1020 A) complete all as specified and directed. SMC/4/100, | 3 | Set | 4,000 ₹12,000 | 1,500 ₹4,500 | 1,150 ₹3,450 Lowest | 1,300 ₹3,900 | 1,500 ₹4,500 | 1,765 ₹5,295 | 4,999 ₹14,997 |
| 1.05 | Supply only in replacement pressure regulation valve (ACCEL Part No. ASL1022 R) complete all as specified and directed. SMC/4/100, | 6 | Set | 5,000 ₹30,000 | 1,000 ₹6,000 | 990 ₹5,940 | 400 ₹2,400 Lowest | 500 ₹3,000 | 920 ₹5,520 | 1,999 ₹11,994 |
| 1.06 | Supply only in replacement Set of gasket (ACCEL Part No. ASL1453) complete all as specified and directed. SMC/4/100, | 6 | Set | 1,500 ₹9,000 | 1,400 ₹8,400 Lowest | 3,850 ₹23,100 | 1,400 ₹8,400 Lowest | 2,850 ₹17,100 | 1,687 ₹10,122 | 1,999 ₹11,994 |
| 1.07 | Supply only in replacement Set of neoprene ' O' RINGS (ACCEL Part No. ASL1454) complete all as specified and directed. SMC/4/100, | 6 | Set | 1,500 ₹9,000 | 600 ₹3,600 | 950 ₹5,700 | 200 ₹1,200 Lowest | 900 ₹5,400 | 1,227 ₹7,362 | 1,999 ₹11,994 |
| 1.08 | Supply only in replacement Set of Dowty ring (ACCEL Part No. ASL1455) complete all as specified and directed. SMC/4/100, | 6 | Set | 1,500 ₹9,000 | 800 ₹4,800 | 750 ₹4,500 | 100 ₹600 Lowest | 120 ₹720 | 1,073 ₹6,438 | 1,999 ₹11,994 |
| 1.09 | Supply only in replacement Set of SEALING RING (ACCEL Part No. ASL1456) complete all as specified and directed. SMC/4/100, | 6 | Set | 1,500 ₹9,000 | 600 ₹3,600 | 850 ₹5,100 | 110 ₹660 | 40 ₹240 Lowest | 385 ₹2,310 | 1,999 ₹11,994 |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
4 Dec 2025, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT 110010
COMPREHENSIVE MAINT OF DX TYPE CENTRAL AC PLANT REPAIR OVERHAULING OF WATER COOLED CENTRE AC PLANT REWINDING OF COMPRESSOR MOTOR REPLACEMENT OF VALVE HEPA FILTER AND REPAIR OF UNSV PART OF LT PANELS CABLES EARTHING VFD GE (EAST) DELHI CANTT10
2025_MES_738531_1
CWE/D-75/2025-26
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE EAST DELHI CANTT
₹1.6 L
Yes
29 Jan 2026
6 Nov 2025
5 Dec 2025
6 Nov 2025
4 Dec 2025
27 Nov 2025
Amount
Dismantling compressor of central AC plant for overhauling complete with connected copper pipe line and loading unloading mechanism & pump down the existing refrigerant in separate cylinder, disconnecting of electric motor of compressor, refrigerant line, gauges pipe and carry out the general over hauling of compressor, compressor model:- SMC/4/100, Make:- Accel (R-22) including replacement of springs, aluminium washer packing, screw, lath work, cleaning detergent, cotton waste, changing of compressor oil etc and cleaning the suction filter, oil filter, replacing the defective parts compete system for safe guard the gas with self pumping down system or with total recovery unit system incld. following operation complete all as specified & directed. (i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure/ leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (iii) Charging of complete system with R-22 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.... (iv) Measure the inlet and outdoor temperature of Chiller unit for performance checking and maintaining temp. as per require site. (v) Testing & commissioning of compressor after completion. Note:- (a) Spares of compressor shall be measured and paid separetely under respective item of this schedule (Sr No. 1.01 to 1.19). (b) Any minor items required for overhauling except described here-in-after shall be supplied by the contractor with out any extra cost to the deptt and the rates for the same shall deemed to be included in the quoted rates.
Supply only in replacement PISTON with PIN & Rings- 04 Nos (ACCEL Part No. ASL1018R) complete all as specified and directed. SMC/4/100,
Supply only in replacement cylinder with suction valve -04 Nos(R-22) (ACCEL Part No. ASL1019A) complete all as specified and directed. SMC/4/100,
Supply only in replacement OIL pump (ACCEL Part No. ASL1011A) complete all as specified and directed. SMC/4/100,
Supply only in replacement Discharge valve assembly (R-22) (ACCEL Part No. ASL1020 A) complete all as specified and directed. SMC/4/100,
Supply only in replacement pressure regulation valve (ACCEL Part No. ASL1022 R) complete all as specified and directed. SMC/4/100,
Supply only in replacement Set of gasket (ACCEL Part No. ASL1453) complete all as specified and directed. SMC/4/100,
Supply only in replacement Set of neoprene ' O' RINGS (ACCEL Part No. ASL1454) complete all as specified and directed. SMC/4/100,
Supply only in replacement Set of Dowty ring (ACCEL Part No. ASL1455) complete all as specified and directed. SMC/4/100,
Supply only in replacement Set of SEALING RING (ACCEL Part No. ASL1456) complete all as specified and directed. SMC/4/100,
Supply only in replacement SPRING FOR SAFETY HEAD (ACCEL Part No. B-12) complete all as specified and directed. SMC/4/100,
Supply only in replacement HALF SECTION OF BRG. STD. (ACCEL Part No. E-02) complete all as specified and directed. SMC/4/65
Supply only in replacement BEARING WITH BUSHING STD (ACCEL Part No. C-03) complete all as specified and directed.SMC/4/100,
Supply only in replacement CONNECTING ROD ASSEMBLY (ACCEL Part No. ASL1017 A) complete all as specified and directed. SMC/4/100,
Supply only in replacement OIL STRAINER (ACCEL Part No. ASL1033 A) complete all as specified and directed. SMC/4/100,
Supply only in replacement CRANKSHAFT - FOR SMC/4/100 (ACCEL Part No. ASL1416 A) complete all as specified and directed. SMC/4/100,
Supply only in replacement SINGLE FRAME ASSEMBLY (ACCEL Part No. UN-FRM-100) complete all as specified and directed. SMC/4/100,
Supply only in replacement UNLOADING CYLINDER ASSEMBLY (ACCEL Part No. ASL1012A-1) complete all as specified and directed. SMC/4/100,
Supply only in replacement SHAFT SEAL ASSEMBLY (ACCEL Part No. ASL1010 R) complete all as specified and directed. SMC/4/100,
Supply only in replacement BUSHING FOR PISTON PIN (ACCEL Part No. E-07) complete all as specified and directed. SMC/4/100,
S & F in repair oil pressure cut out for compressor of central type AC plant of any capacity as specified and directed by Engr-in-Charge.
S & F in repair high pressure cut out for Accel make compressor of central type AC plant of any capacity as specified and directed by Engr-in-Charge.
S & F in repair low pressure cut out for Accel make compressor of central type AC plant of any capacity as specified and directed by Engr-in-Charge.
S & F in repair low pressure gauge/ oil pressure gauge for Accel make compressor of central type AC plant of any capacity as specified and directed by Engr-in-Charge.
S & F in repair high pressure gauge for Accel make compressor of central type AC plant of any capacity as specified and directed by Engr-in-Charge.
S & F in repair three way solenoid valve suitable for (Accel make compressor, compressor model-SMC/4/65 and SMC/4/100) central type AC plant of any capacity as specified and directed by Engr-in-Charge.
S&F in repair CT Fan complete section Fan, Fan Dia-1500 mm , connected GI nutbolts and accessories all fitting sutiable for 180 TR cooling tower, CT Model-5061, CT Make-delta as per specified & directed by Engr-in-charge.
S&F in repair CT Fan complete section Fan, Fan Dia-1200 mm , connected GI nutbolts and accessories all fitting sutiable for 120 TR cooling tower, CT Model-5061, CT Make-delta as per specified & directed by Engr-in-charge.
S&F in repair CT Fan complete section Fan, Fan Dia-1000 mm , connected GI nutbolts and accessories all fitting sutiable for 90 TR cooling tower, CT Model-5032, CT Make-delta as per specified & directed by Engr-in-charge.
S&F in repair CT Fan complete section Fan, Fan Dia-900 mm , connected GI nutbolts and accessories all fitting sutiable for 50 TR cooling tower, CT Model-5032, CT Make-delta as per specified & directed by Engr-in-charge.
S & F in replacement of Expansion valve for plant capacity 30TR (cat part no. 107E in sporlane or equivalent model of Danfoss/ Emerson)
S & F in replacement of Expansion valve for plant capacity 40TR X3, (cat part no. 107E in sporlane or equivalent model of Danfoss/ Emerson)
M&L for repairing/ servicing incl. transportation to authorised workshop the centrifugal pump of following capacities by disconnecting the pump from motor, opening for inspection, replacing the born out parts like gland bush, bearings, gland bolts and nuts, gland packing, gasket, water seal etc including repairing to pump shaft by remetalling, grinding, polishing and reassembling complete pump & refixing in same position & connecting including replacing the rusted nuts, bolts, washers etc and testing complete all as specified and directed by Engr-in-Charge (Srl No. 15.01 TO 15.02)
Condenser or Chiller Pump of capacity 5 HP, Head Range-6-38M, LPS-7.4.
Condenser or Chiller Pump of capacity 10 HP, Head Range-6-38M.
Condenser or Chiller Pump of capacity 15 HP, Head Range-6-38M.
Condenser or Chiller Pump of capacity 7.5 HP, Head Range-6-38M.
Supply & charge the refrigerent R22 Gas as specified and directed by Engr-in-Charge.
Supply and replacement of compressor oil N-68
M&L for descaling of condensser tube of central AC plant of cap 3x15TR by disconecting the condensser from the system, cleaning by descaling pump of suitable capacity of 110 ' feet head using descaling solution of make Hibird or descaling solution, cleaning condenssor tube by nylon bursh & MS rod of suitable size, replacement of rubber joints and u/s nut bolts Note:- (i) Arrangment of T&P such as pump, tube, descaling solution shall be carried out by contractor. (ii) Descalling of all respective condensors are considered as one job.
All as per Ser items No 16 here-in-before but 3X30TR
All as per Ser items No 16 here-in-before but 3X40TR
S&F in replacemant 'V' Belt of Size B-48 complete as specified and directed by Engr-in-Charge.
S&F in replacemant 'V' Belt of Size A-25 complete as specified and directed by Engr-in-Charge.
S&F in replacemant 'V' Belt of Size A-29 complete as specified and directed by Engr-in-Charge.
S&F in replacemant 'V' Belt of Size C-112 complete as specified and directed by Engr-in-Charge.
S&F in replacemant 'V' Belt of Size B-72 complete as specified and directed by Engr-in-Charge.
S&F in replacemant 'V' Belt of Size B-108 complete as specified and directed by Engr-in-Charge.
S&F in replacemant 'V' Belt of Size A-58 complete as specified and directed by Engr-in-Charge.
S&F in replacemant 'V' Belt of Size A-53 complete as specified and directed by Engr-in-Charge.
S&F in replacemant 'V' Belt of Size C-98 complete as specified and directed by Engr-in-Charge.
S&F in repairs fan 'V' Belt of Size A-41 complete as specified and directed by Engr-in-Charge.
S&F in repairs fan 'V' Belt of Size A-42 complete as specified and directed by Engr-in-Charge.
S&F in repairs fan 'V' Belt of Size B-72 complete as specified and directed by Engr-in-Charge.
S&F in repairs fan 'V' Belt of Size A-32 complete as specified and directed by Engr-in-Charge.
S&F in repairs fan 'V' Belt of Size A-28 complete as specified and directed by Engr-in-Charge.
Taking down the existing unserviceable sluice valve of size 100 mm dia, Supply and fixing new sluice valve of size 100 mm dia including cutting welding of pipe up to required size with flange complete all as specified and directed by Engr-in-Charge.
Taking out the existing unserviceable sprinkter of cooling tower and supply, installation, testing and commissioning of new sprinkter assembly for cooling tower as following as specified and as directed by Engr-in-Charge.
M&L for taking out compressor Motor (Motor cap-40 HP, MAKE-KIRLOSKAR) of AC plant and Dis mantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . Opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & discription to match with existing including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed.
M&L for taking out compressor Motor (Motor cap- 50 HP, MAKE-GENERAL ELECTRIC POWER INDIA) of AC plant and Dis mantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & discription to match with existing including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed.
S&F in repair all accessories corroision proof PVC Filling, inlet louvers, drift, PVC eliminators,PVC water distribution chamber and nozzeles (self rotating sprinklers) GI nut bolt (included float valve)and all fitting complete all as specified & directed. Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b) The induced draught cooling tower should be operate according to the counter flow principle. (c) Cooling tower specification for PVC filling (Delta make) (i) Capacity - 90 TR
S&F in repair all accessories corroision proof PVC Filling, inlet louvers, drift, PVC eliminators,PVC water distribution chamber and nozzeles (self rotating sprinklers) GI nut bolt (included float valve)and all fitting complete all as specified & directed. Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b) The induced draught cooling tower should be operate according to the counter flow principle. (c) Cooling tower specification for PVC filling (Delta make) (i) Capacity - 120 TR
S&F in repair all accessories corroision proof PVC Filling, inlet louvers, drift, PVC eliminators,PVC water distribution chamber and nozzeles (self rotating sprinklers) GI nut bolt (included float valve)and all fitting complete all as specified & directed. Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b) The induced draught cooling tower should be operate according to the counter flow principle. (c) Cooling tower specification for PVC filling (Delta make) (i) Capacity - 180 TR
S&F in repair all accessories corroision proof PVC Filling, inlet louvers, drift, PVC eliminators,PVC water distribution chamber and nozzeles (self rotating sprinklers) GI nut bolt (included float valve) and all fitting complete all as specified & directed. Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b) The induced draught cooling tower should be operate according to the counter flow principle. (c) Cooling tower specification for pvc filling (Delta make) (i) Capacity - 50 TR
Taking down the existing unserviceable Y-Strainers of size 80 mm dia, Supply and fixing new Y-Strainers 80 mm dia including cutting welding of pipe up to required size with flange complete all as specified and directed by Engr-in-Charge.
Taking down the existing unserviceable Y-Strainers of size 100 mm dia, Supply and fixing new Y-Strainers 100 mm dia including cutting welding of pipe up to required size with flange complete all as specified and directed by Engr-in-Charge.
Taking down the existing unserviceable Balancing valve of size 100 mm dia, Supply and fixing new Balancing valve 100 mm dia including cutting welding of pipe up to required size with flange complete all as specified and directed by Engr-in-Charge.
Taking down the existing unserviceable Balancing valve of size 125 mm dia, Supply and fixing new Balancing valve 125 mm dia including cutting welding of pipe up to required size with flange complete all as specified and directed by Engr-in-Charge.
Taking down the existing unserviceable NRV of size 80 mm dia, Supply and fixing new NRV 80 mm dia including cutting welding of pipe up to required size with flange complete all as specified and directed by Engr-in-Charge.
Taking down the existing unserviceable NRV of size 100 mm dia, Supply and fixing new NRV 100 mm dia including cutting welding of pipe up to required size with flange complete all as specified and directed by Engr-in-Charge.
Taking down the existing unserviceable NRV of size 125 mm dia, Supply and fixing new NRV 125 mm dia including cutting welding of pipe up to required size with flange complete all as specified and directed by Engr-in-Charge.
Repair replacement of defective/ unservceable Heating elememt, Power contactor, relay and complete service of Hot water Generators (Make: Rapid Cool) - (02 Nos) complete all specified and as directed. . Replacements of all defective/ unserviceable parts and periodical painting, fabrication work, if any required to maintain smooth functioning of equipments, control and power wiring etc required for smooth functioning of 02 Nos equipments during entire comprehensive maintenance period shall be included in rate quoted by the contractor.
Dismantling Chiller of Capacity 30TR central AC plant for replacement of complete connected copper pipe line , MS Pipe line ,and connected asseccerise Heat Exchanger M.S Shell Dia: 200MM (10") (ID) x 6 mm Thick, Copper Tubes 1/2" OD IGT- 94 Nos Lenght of Copper Tube 2400mm ,Water in and out dia 80mm No of passes- 04 Nos for compressor model:- SMC/4/100, Make:- Accel (R-22) complete all as specified & directed. (i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure/ leakage up to 72 Hrs rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (iii) Charging of complete system with R-22 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.... (iv) Measure the inlet and outdoor temperature of Chiller unit for performance checking and maintaining temp. as per require site. (v) Testing & commissioning of compressor after completion.
Dismantling Condensor of Capacity 30TR central AC plant for replacement of complete connected copper pipe line , MS Pipe line ,and connected asseccerise Condensor M.S Shell Dia: 200MM (10") (ID) x 6 mm Thick, Copper Tubes 1/2" OD IGT- 94 Nos Lenght of Copper Tube 2400mm ,Water in and out dia 80mm No of passes- 04 Nos for compressor model:- SMC/4/100, Make:- Accel (R-22) complete all as specified & directed. (i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure/ leakage up to 72 Hrs rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (iii) Charging of complete system with R-22 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.... (iv) Measure the inlet and outdoor temperature of Chiller unit for performance checking and maintaining temp. as per require site. (v) Testing & commissioning of compressor after completion.
Supply installation, testing & commissioning of shell & tube type condenser unit of 40 TR capacity for DX type AC plant 3x40 TR capacity. The items comprise following specifications:- Type : horizontal, shell & tube type Shell size : Shell dia 300 mm ID + 6 mm Material : MS type Nos. of copper tubes : 100 Nos. approx Copper tube size : 19 mm OD & 16G integral fins Length of tube : 2130 mm water in & out 80 mm, No of passes 02, complete all as specified and directed.
S&F in repair 3 pole power contactor 415 V, type MNX 70 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed by Engr-in-Charge.
S&F in repair 3 pole power contactor 415 V, type MNX 50 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed by Engr-in-Charge.
S&F in repair 3 pole power contactor 415 V, type MNX 40 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directedby Engr-in-Charge.
S&F in repair 3 pole power contactor 415 V, type MNX 25 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed by Engr-in-Charge.
S&F in repair 3 pole power contactor 415 V, type MNX 18 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed by Engr-in-Charge.
Supply only in replacement of thermal over load relay range 20-32 Amps, with built in single phase preventer, direct/ separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as directed by Engr-in-Charge.
All as per Srl item No 56 here-in-above but 13-21 Amps capacity.
All as per Srl item No 56 here-in-above but 9-14 Amps capacity.
All as per Srl item No 56 here-in-above but 1.5 - 2.5 Amps capacity.
S&F in replacement, of MCCB 100 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed by Engr-in-Charge.
S&F in replacement, of MCCB 125 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed by Engr-in-Charge.
S&F in replacement, of MCCB 200 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed by Engr-in-Charge.
S&F in replacement, of MCCB 250 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed by Engr-in-Charge.
S&F in replacement, of MCCB 400 Amp, 3 pole thermal magnetic relese based with breaking capacity 50 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed by Engr-in-Charge.
S&F in replacement, of MCCB 63 Amp, 3 pole thermal magnetic relese based with breaking capacity 30 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed by Engr-in-Charge.
S&F in replacement, of MCB 63 Amp, TPN, C-Curve complete all as directed by Engr-in-Charge.
S&F in replacement, of MCB 40 Amp, TPN, C-Curve complete all as directed by Engr-in-Charge.
S&F in replacement, of MCB 100 Amp, TPN,C-Curve complete all as directed by Engr-in-Charge.
Supply & fixing in replacement of single phase preventor relay TYPE Sz5(6wire version )415 V ,mode of operation Auto/Manual/Bypass, auto restrat with in 30 sec suitable for Star-delta strater incl taking down of unserviceable relay and making all electric connection, complete all as directed by Engr-in-Charge.
Supply & fixing in replacement of LED type indicator lamp of red/yellow/green colour for phase indication, ( Switch on position show red ,off position show green and trip show yellow )complete all as directed by Engr-in-Charge.
Supply & fixing In replacement of Star Delta electronic timer time delay 3 to 30 second as per existing size and all as directed by Engr -in Charge by Engr-in-Charge.
Supply and fix in replacement front mounting auxilary contact blocks for suitable contactor any description type 2NO+2NC (MNX/MCX) all as direction by Engr-in-Charge.
Supply, Laying, jointing and testing in replacement of under electric cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches /duct /pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engr-in-Charge for the following sizes:-
(a) 3.5 Core 120 Sqmm
(b) 3.5 Core 95 Sqmm
(c) 3.5 core 35 sqmm
(d) 4 core 25 sqmm
(e) 4 core 16 Sqmm
M & L for Sub-main wiring with 6.0 Sq mm (Nominal area) PVC insulated FRLS unsheathed copper cable of 1100V grade with stranded copper conductor in and including PVC conduit ,casing caping wiring with connected accessories along with continuous earth wire of 6 Sq mm PVC insulated, copper conductor cable and connected to common earth dolly with and including taking down old unserviceable submain wiring. with all accessories all as directed by Engr -in-Charge .( Note- Four run 6 Sq mm for the three Phase and neutral, one run earth conductor 4 Sqmm and PVC conduit medium grade of suitable size should be measured in a single run)
M & L for Sub-main wiring with 10.0 Sq mm (Nominal area) PVC insulated FRLS unsheathed copper cable of 1100V grade with stranded copper conductor in and including PVC conduit ,casing caping wiring with connected accessories along with continuous earth wire of 10 Sq mm PVC insulated, copper conductor cable and connected to common earth dolly with and including taking down old unserviceable submain wiring. with all accessories all as directed by Engr -in-Charge .( Note- Four run 10 Sq mm for the three Phase and neutral, one run earth conductor 10 Sqmm and PVC conduit medium grade of suitable size should be measured in a single run)
M & L for Sub-main wiring with 4.0 Sq mm (Nominal area) PVC insulated FRLS unsheathed copper cable of 1100V grade with stranded copper conductor in and including PVC conduit ,conceal wiring with connected accessories along with continuous earth wire of 4 Sq mm PVC insulated, copper conductor cable and connected to common earth dolly with and including taking down old unserviceable submain wiring. with all accessories all as directed by Engr -in-Charge .( Note- Two run 4 Sq mm for the Phase and neutral, one run earth conductor 4 Sqmm and PVC conduit medium grade of suitable size should be measured in a single run)
M & L for Sub-main wiring with 1.5 Sq mm (Nominal area) PVC insulated FRLS unsheathed copper cable of 1100V grade with stranded copper conductor in and including PVC conduit ,casing caping wiring with connected accessories along with continuous earth wire of 1.5 Sq mm PVC insulated, copper conductor cable and connected to common earth dolly with and including taking down old unserviceable submain wiring. with all accessories all as directed by Engr -in-Charge .( Note- Two run 1.5 Sq mm for the Phase and neutral, one run earth conductor 1.5 Sqmm and PVC conduit medium grade of suitable size should be measured in a single run)
S& F in replacement of LED tubelight of 20W capacity complete all as specified and directed
S& F in replacement of LED Bldg security light of 45W capacity complete all as specified and directed
S&F in replacement of modular switch socket combination 6/16 A, module 3, alongwith metal flush box, cover plate complete all as specified and directed.
S&F in replacement of Exhaust fan , steel body AC single phase. 230 V, of size 450mm sweep heavy duty complete all as specified and directed
S & F in replacement of Load Break 3 Pole ON- Off switch for AC plant control panel complete all as specified and directed by Engr-in-Charge
M & L for control wiring with 1.5 Sqmm including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engr-in-Charge
Checking the interlocking control and attending the compaint of Control panel wiring of AC plant and making it fully serviceable with and including all size of wires, thimble, PVC, bakelight, connection plate Nut bolt, MCB, Indicator Lamp, NO NC Block and other items. Note 01:- After intimation of breakdown by JE/ AGE E/M through telephone or verbally, the contractor should arrange the machanic to attend the complaint in side BHDC premisis within 2 hours and make them functional, if any item required the same shall be measured from particular item from schedule for complete work. Note 02: If complaint intimation is done after 1600 hrs then complaint to be attented by contractor at 800 hrs next day. Note 03 : If contractor failer to attend complaint with in time frame, the recovery of Rs400/ Hrs will be implemented.
Supply, installation, testing and commissioning of VFD 4 KW/5HP, Panel mounted complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including provision of 40 mm GI Tubing, light grade and watering pipe shall be 20 mm bore GI light grade including excavation & earth work, PCC pit with CI cover, Charcol, salt, funnel, wire mesh, GI strip Up to 7.5 mtrs length complete all as specified and directed.
M&L for Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strip
Comprehensive/ Routine maintenance of AFM SYSTEM of following items:- a) HMI with 7” touch screen display -09 Nos b) Controllers for AHUs – 09 Nos c) Differential Pressure Switch; Qty-18 N0s d) Differential Pressure Sensor Air; Qty- 18 Nos e) Duct type temperature and RH Sensor; Qty- 09 Nos Note 01:- After intimation of breakdown by JE/ AGE E/M through telephone or verbally, the contractor should arrange the machanic to attendential pressure Switch for the complaint in side BHDC premisis within 24 hours and make them functional, if any item required the same shall be measured from particular item from schedule for complete work. Note 02: If complaint intimation is done after 1600 hrs then complaint to be attented by contractor at 800 hrs next day. Note 03 : If contractor failer to attend complaint with in time frame, the recovery of Rs400/ Hrs will be implemented. Note 04: All above complaint attend by original AFM OEM the cost of spares and labour for any minor or major repairs of AFM System as and when required (as recommended by the OEM SIEMENS during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same are deemed to be included in the unit rates of item as above
Supply and laying MS Plates for cable trench (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmen complete all as specified and directed.
S&F in replacement Absolute HEPA filter of size 830x550x70 mm B.T. having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed by Engr-in-Charge.
S&F in replacement Absolute HEPA filter of size 550x540x70 mm B.T. having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed by Engr-in-Charge.
S&F in replacement Absolute HEPA filter of size 915x610x70 mm F.T. having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed by Engr-in-Charge.
S&F in replacement Absolute HEPA filter of size 610x610x70 mm B.T. having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed by Engr-in-Charge.
S&F in replacement of hepa filter screen complete all as specified and directed.
Hepa filter testing : OT validation as per NABH by using aerosol generator, photometer, particle counter, digital anemometer, differential pressure meter & thermo hygrometer and following test carried out : Hepa/ ULPA filter air velocity test Particle count test DOP test Room differential pressure test Temp & RH test complete all as specified and directed by Engr in charge. Note : Third party cetificate required for above test and submit this office for record purpose.
M&L for air duct cleanning filter vacuum unit having high pressure as required. Robotic video camera most be used for inspection, cleaning of duct, using robotic camera and the video film copied on CD in duplicate before and after cleaning will be kept on record of engineer in charge & other complete all as specifed and directed.
SANJEEV ENTERPRISES (BID ID -3487690)
Singh Associates (BID ID -3488400)
RUCHIKA ENGG.WORKS (BID ID -3487799)
Iconic Engineers (BID ID -3489114)
Flint India (BID ID -3489508)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3487278)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_826947.xls
BOQ • 0.31 MB
TENDERDOCUMENTD75.pdf
Tender Documents • 1.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .