B-NS Civil Works
IR for deployment of JCB with pneumatic breaker complete including fuel charges, 1 driver etc. as perinstruction of site engineer as per site requirement with contractor & apos;s own labour, T&P, handling & re-handling, alltaxes etc. So, nothing extra shall be paid to the contractor except the rates, whatsoever the case may be. The itemincludes all taxes, GST etc
IR for pneumatic drill for demolition of CC, brick, washable apron, RCC or any other hard structurescomplete all. Rate including all ascent, descent, crossing of Nallah, track and other obstacles including cost of diesel,petrol, operator and other incidental charges complete job, in all respect so nothing is to be paid extra except theaccepted rates, what so ever the case may be.
C-Electrical Work
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS 1 PVC insulatedcopper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modularplate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cableetc. as required conforming to IS:694(or latest) and other relevant IS/IEC standards. Group C. (unit = point)
Supply and recessing/fixing of PVC conduit pipe of size conforming to IS. 9537 Part- III.1987 (or Latestversion) with accessories junction box, bends etc. including making chase, plastering/clamping etc. as per siterequirement conforming to IS 9537 (Part 3): 2018 or latest
Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi 3 stranded copper(annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed/surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per technical specification including connections, testing and commissioning. Size = 1x2.5 sq.mm
Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi 4 stranded copper(annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed/surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per technical specification including connections, testing and commissioning. Size = 1x4.0 sq.mm
Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi 5 stranded copper(annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed/surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per technical specification including connections, testing and commissioning. Size - 1x6.0 sq.mm
Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi 6 stranded copper(annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed/surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per technical specification including connections, testing and commissioning. Size - 1x10.0 sq.mm
Supply, fixing, testing and commissioning of following modules, GI box along with 7 modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement completeand conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854:1997or latest. Size - 6 Module
Supply, fixing, testing and commissioning of following modules, GI box along with 8 modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854:1997or latest. Size - 8 Module
Supplying and fixing following modular switch /socket on the existing modular plate & 9 switch box including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854:1997or latest. 6 Amp Switch
Supplying and fixing following modular switch /socket on the existing modular plate & 10 switch box including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854:1997or latest. 16 Amp Switch
Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854:1997or latest. 3 pin 5/6 A socket outlet.
Supplying and fixing following modular switch /socket on the existing modular plate & 12 switch box including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854:1997or latest. 6 pin 15/16 A socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on 13 surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required and conforming to IS 3854:2023/ IEC 60669-1, IS 14772:2020 & CPWD General Specifications for Electrical WorksPart-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on 14 surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc.as required and conforming to IS 3854:2023, IS 14772:2020 or latest & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 1.32
Supply, Fixing, testing & commissioning of ceiling rose, 3 plate conforming to IS : 371- 1999 (or Latest Version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and as per Tech. Specification.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required .
Earthing with 40 mm Dia GI pipe class 'B' 4.5 meter long earth electrode as per 17 IS:3043 (latest version)to achieve earth resistance less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mm x 400 mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per drawing.
Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per 18 IS:3043/1987 (Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable 19 tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required conforming to all relevant IS/IEC standards. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable 20 tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required conforming to all relevant IS/IEC standards. 300 mm width X 50 mm depth X 1.6 mm thickness
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV 21 grade of following size direct in ground including excavation ((upto 75-100 cm depth and not less than 35 cm wide), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest. Upto 35 sq. mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation ((upto 75-100 cm depth and not less 22 than 35 cm wide), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV 23 grade of following size direct in ground including excavation ((upto 75-100 cm depth and not less than 35 cm wide), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest. Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation 24 including excavation(upto 75-100 cm depth and not less than 55 cm wide& maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest. Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation 25 including excavation(upto 75-100 cm depth and not less than 55 cm wide& maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest. Above 35 sq. mm and upto 95 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation 26 including excavation(upto 75-100 cm depth and not less than 55 cm wide& maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC,RCC, 27 road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative as per CPWD DSR item no. 7.2 conforming to IS 1255 (Reviewed in 2016) or latest. Upto 35 sq. mm (clamped with1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC,RCC, 28 road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative as per CPWD DSR item no. 7.2 conforming to IS 1255 (Reviewed in 2016) or latest. Above 35 sq. mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC,RCC, 29 road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative as per CPWD DSR item no. 7.2 conforming to IS 1255 (Reviewed in 2016) or latest. Above 185 sq. mm and upto 400sq. mm (clamped with 25/40x3mm MS flat clamp)
Supply of XLPE LT cable complete of size 4Cx25 sq.mm. size conforming to IS:7098 or latest
Supply of XLPE LT cable complete of size 4Cx70 sq.mm. size conforming to IS:7098 or latest
Supply of XLPE LT cable complete of size 4Cx240 sq.mm. size conforming to IS:7098 or latest
Supply of LED light luminaire, having system wattage 2x18 watt. LED tube and inbuilt 33 LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be conforming to PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev-'3' & Rev-'4') or latest.
S/F/T/C of recessed/on surface LED light luminaries 595x595 mm size, Tile type, having system wattage less than or equal to 48 Watt, CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement, accessories of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121 elect/PS/2018 (Rev- '3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at Tech Spec-III attached or latest.
Supply of LED based high bay luminary with IP 65 having system wattage less than or 35 equal to 150 Watt complete conforming to CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev '3') or latest at Tech Spec-II attached &PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev '4') at Tech Spec-III attached or latest.
Supply of 150 watt LED based flood light luminary with cool white light, pressure die 36 cast aluminium housing, IP 65 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev'3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev '4') at Tech Spec-III attached or latest.
S/F/T/C of 4-feet long surface mounting 36-watt, 5700K, CRI>80, LED Luminarie. 37 Fitting shall be environmental friendly, long life, corrosion resistant, impact proof IP66 or latest with PC housing & opal finish cover suitable for wet location. Similar to Make Havells Model No. MAGNUM NEO or Equivalent . Fitting shall be suitable for operation on single phase 240Volt, 50 HZ AC supply complete.
Supply, fixing, testing and commissioning of 380mm sweep, 1400 rpm (approx.) propeller type exhaust fan complete as per IS, IE rule & site requirement. Make Bajaj, Usha, Havells, Orient or equivalent
Supply, fixing, testing and commissioning of 45 watt LED based street light luminary 39 with cool white light, pressure die cast aluminium housing, IP 65 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev '3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121Elect/PS/2019 (Rev '4') at Tech Spec-III attached or latest.
S/L/T/C of HDPE pipe of 160 mm dia having material grade PE-100, wall thickness PN- 40 6 and confirming to IS-4984 or latest as per IE rules and site requirement for cable laying through HDPE pipe of 160mm diameter by trench less method as per IS -1255 or latest & IE rules and site requirement.
S/F/T/C of LT distribution board double door type made up of CRCA sheet, phosphatised powder painted, Anti corrosion complete with neutral link, earth point, Din rail and prewired confirming to IEC 61439 of make ABB, Havells, Siemens, L&T, Schneider, Legrand, C&S or 41 equivalent with following items of matching make to be fixed in distribution board, confirming to IEC 60947 or latest, other relevant IE/IS rules and site requirement. 63 A 30/100/300mA ,4P RCBO AC type conforming to IS/IEC 60947-2= 01 No. (Incoming) 6-32A MCB SP "B" series = 18 Nos.(Outgoing) It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal ,reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs.
D/S/F/T/C of LT panel (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make ABB, Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947-or latest with digital measuring instrument & bus-bar (copper) 42 arrangement confirming to IEC 60947 or latest, other relevant IE/IS and site requirement. a) 4P MCCB 400Amps 36 kA with adjustable thermal & fixed magnetic release =01 Nos. (Incoming). b) 4P400 Amps on load change over switch (COS)=01 No. c) 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing). d) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release=04Nos. (Outgoing).
Design, Supply, fixing, testing and commissioning of front operated double door type weather proof feeder pillar body made of CRCA sheet with anti-corrosion treatment and suitable having IP 65 protection (MCCB -Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Havells, Siemens, L&T, Schneider, Legrand or equivalent conforming to IS:13032, IEC 60947, 61439 or latest with digital measuring instrument & bus-bar arrangement confirming to PCEE/NR's spec. No. PCEE/NR/126-Elect/PS/2019 at Tech Spec-VI attached or latest and as per IS, IE rules and site requirement. It should be dust and vermin proof, conforming to IEC60947 or latest, other relevant IE/IS and powder coating as per IS/IEC standards. 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release = 01 No. (Incoming) 4P MCCB 125Amps 36 kA with adjustable thermal &fixed magnetic release = 02 No. (outgoing) 4P MCCB 63Amps 36 kA with adjustable thermal & fixed magnetic release =04 No. (outgoing)
S/E//T/C of 16-meter-high mast system suitable for 9 Nos. LED flood light luminaries 44 with the help of suitable equipment including accessories control panel for high mast system with explanatory note for provision of RCBO in place of MCB from I/C side. Each high mast shall also have one twin dome aviation obstruction light with 2nos. LED lamp. Make BAJAJ, Osram, PHILIPS, GE or equivalent.
S/F/T/C of astronomical timer-based control panel for High Mast tower lighting suitable for 25A 4 P contactor as per model No. Alpha Rex3 D21, 1 channel Cat Part 412654 of Legrand or equivalent. Panel should be double door weather proof type complete.
Fabrication, supply and erection of Fencing around the high mast in square shape 46 size 2M x 2M and height 1.5M from ground level fabricated from MS angle size 40x40x6mm, MS Flat size 40x6mm and wire mesh made of 8SWG wire and 1M wide hinged type lockable door as per drawing approved by Railway including grouting, CC platform around the high mast above 0.30M above ground level and painting, danger plate etc. complete as per site requirement.
Supply, Installation, Testing & Commissioning of 1.5 TR window type air conditioner non-CFC refrigerant, copper coil, latest BEE 5 star rated complete as per IS, IE rules and site requirement. Make: Daikin, Hitachi & Carrier or equivalent
Fabrication of MS stand/cabinets or any other MS structure of approved drawing for 48 precooling points/battery charger/ covering of electrical structure. The work includes cutting, welding, riveting, nut bolts of the MS structure including applying a primary coat of steel primer and one coat of paint of approved shade.
S/F/T/C of 400mm sweep wall mounted fan complete.
Supply fixing testing and commissioning of Heavy-duty wall mounted air circulator 50 fan 600 mm (24inch), 1440 RPM ,180-watt, Air delivery 270 cubic meter per minute, no of blade 3, single speed, suitable to work on230 Volts 50 HZ, single phase IS 2312 & IS 302 or latest and other relevant IS/IEC standards
Supply & erection of hot dip galvanized octagonal pole 5 Metres. long Double Arms, confirming to IS2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel baseplate size 200 x200x12 mm complete with appropriate sleeve at the 51 top of the pole for mounting arm bracket 300 mm long suitable for LED street light fittings including casting, muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm double insulated weather proof cables Square
Design, manufacture, display of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed /router cut on monomeric 52 calendared vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size endcap of 1.5 mm thick SS304should be provided as per Railway Board letter no.2023/SD-II/22/07/02 dated 15.05.2023. Square
Erection and installation of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 53 160 deg. The approved colour text and graphics shall be printed /router cut on monomeric calendared vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light.
Supply, fixing, testing and commissioning of 90W LED based street light luminary 54 with cool white light, pressure die cast aluminium housing, IP 65 or latest complete conforming to CEE/NR's spec. No. CEE/NR/121Elect/PS/2018 (Rev '3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev '4')at Tech Spec-III attached or latest.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below,350 RPM (tolerance as per IS : 374-2019), THD 55 (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 or latest fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1400mm, service value greater then equals to 6.0CM/Min/Watt, air delivery 245 CM/Min (Minimum)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCWorks2022withcorrectionslipsuptoACS10.pdf
ATTACHMENT
CECIRCULAR6301.pdf
ATTACHMENT
TecnicalspecforPitlight.pdf
ATTACHMENT
TECHSPEC-III.pdf
ATTACHMENT
technicalSpecforLEDBasedLuminaries.pdf
ATTACHMENT
TECHNICALSPECIFICATIONSFORREWIRINGWIRING.pdf
ATTACHMENT
TecnicalSpecfortheOuterdoortypefeederoutdoortypefeederpillarfor440V.pdf
ATTACHMENT
FinalTDofTKDUppgradationRT01-06-2026_1.pdf
ATTACHMENT
Download all tender documents and submit your bid