| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.7 L+₹1,739 (0.05%)Rejected-Finance | L2 | Rejected-Finance other than L1 | |
| 3 | L3₹37.7 L+₹3.0 L (8.58%)Rejected-Finance | L3 | Rejected-Finance other than L1 | |
| 4 | L4₹37.8 L+₹3.1 L (8.86%)Rejected-Finance | L4 | Rejected-Finance other than L1 | |
| 5 | L5₹38.7 L+₹4.0 L (11.6%)Rejected-Finance | L5 | Rejected-Finance other than L1 |
Tender Value
₹47.6 L
EMD Value
₹95,160
Closing Date
11 Jul 2024, 6:00 pmClosed
Maj Mathew M Shepherd
GE (WEST) MATHURA
PROVN OF OPEN REPAIR SHED AND HARD STANDING FOR SPECIAL EQPT NEAR BLDG NO T 105 WITH FOUR COMPARTMENT OPEN FROM ALL SIDES AND OTHER SANCTIONED WORKS UNDER GE WEST MATHURA
2024_MES_658773_1
8300/1247/E8
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) MATHURA
AS PER NIT
10 documents required · 10 mandatory
₹500
GE (WEST) MATHURA
₹95,160
Yes
21 Sept 2024
20 Jun 2024
18 Jul 2024
20 Jun 2024
11 Jul 2024
4 Jul 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed.
Demolition and breaking up drain pipes, set in cement mortar 150mm internal dia (SGSW, AC or reinforced concrete) complete all as specified and directed.
Demolition and breaking up drain pipes, set in cement mortar 200mm internal dia (SGSW, AC or reinforced concrete) complete all as specified and directed.
Demolition of brick work of any description and in any position built in cement Mortar and removing rubbish n.exc. 50m all as specified.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) af any description and in any position not otherwise specifically proveded for complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each not exc 0.50 cum in soft / loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.50 mtr depth for foundation etc or for shafts, wells, cesspits, main holes, pier holes etc complete in soft/loose soil complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and directed.
Removing excavated soil n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 Mtr above the starting point complete all as specified and directed.
M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate in foundation , filling and mass concrete complete all as specified and directed.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 13.00 here-in-before but except brick. Note : Old serviceable brick retrieved from serial item No 4.00 of BOQ here-in-before shall be used under this item.
M&L for Brick work with sub class ‘B’ old size burnt bricks, in one brick thick honey comb walling built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM in (1:4) finished fair and even external surface complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished surface fair and even complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:4 including water proofing compound on fair face of brick or concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge
M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint on walls complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engineer-in-charge.
S&F steel work in tubular trusses including columns, special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1998 grade St-240 complete all as specified and directed.
S&F rolled mild steel as in Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length directed) and similar work conforming to Gde E-250 (Fe 410-W) quality `A’ all as specified and as directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete work in pavement/hard standing of flexural strength 40 Kg/Sqcm in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as spcified and directed.
Forming 12mm thick expansion joints filled with pre formed bitumen filler and top 30 mm primed and sealed with sealing compound grade 'B' complete all as spcified and directed.
Forming contraction / dummy joints 65mm deep 10 mm wide, filled with sealing compound grade 'B' complete all as spcified and directed.
M&L hard core of guage not exc. 63mm deposited spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers not exc 15 cm thick spread, levelled and rammed including watering complete all as specified.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed.
M&L for 75 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for 100 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for sand filling under floors or in foundation complete all as specified and directed.
M&L for Machine pressed precast conctete interlocking paver block with grey cement & pigment any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed.
M&L for cement concrete (1:2:4) type B2 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railigs upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, sligtly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item complete all as spcified and directed.
M&L for salt glazed stone ware drain pipe 150mm grade 'A' laid in trenches and jointed in CM (1:1) complete all as specified and directed.
M&L for salt glazed stone ware drain pipe 200mm grade 'A' laid in trenches and jointed in CM (1:1) complete all as specified and directed.
M&L cement concrete 1:3:6 mix type C2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and hunching against the sides of pipes after laying in trenches to required slope and tested complete all as specified for 150 mm bore pipe complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete 1:3:6 mix type C2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and hunching against the sides of pipes after laying in trenches to required slope and tested complete all as specified for 200 mm bore pipe complete all as specified and directed by Engineer-in-Charge.
S&F mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
M&L for Reinforced cement concrete (nominal mix) (1:2:4) type B1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors roofs landings canopies deck slab and in snelves and the like complete all as specified and directed.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed by Engineer-in-charge.
S&F in repair vitreous china squatting pan Orissa pattern, white of size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, PCC filling and connection to trap and flushing pipe, antisyphonage pipe etc complete all as specified and directed by Engineer-in-charge.
S&F 75-80mm thick factory made precast RCC manhole covers including precast frame of any size & shape (Squre / rectangular / circuler), light duty, out side, fixed at site etc 40 x 40 x 6mm angle complete all specified and directed.
M&L for 200mm dia Reinforced concrete pipe, class NP2, laid in trenches and jointed complete all as specified and directed.
M&L for concealed Point wiring with 2.5 sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 2.5 sqmm PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting/chasing on wall excluding ceiling surface and repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified.
All as per serial item No. 52.00 here-in-before but for One 5 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per serial item No. 52.00 here-in-before but for One 5 pin 5 Amp socket outlet on the same board with other switches complete all as specified and directed.
M&L for point wiring with 4.0 sqmm PVC insulated, unsheathed FRLS multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all and including conduit fittings and fixing accessories 1.60mm thick sunken anodised pressed steel terminal boxes with 3.0 mm thick Polycarbonate based sheet cover for mounting switches, socket etc including 4.0 Sqmm FRLS multistrand copper conductor cable as continuous earth wire connected to comen earth and earth dolly including making good the disturbed surfacescomplete for one socket 20 Amp socket outlet controlled by one switch on independent board.
S&F socket outlet flush type 3/6 pin suitable for 15 Amp plug top Multipurpose 230 volts all as specified & directed.
S&F socket outlet flush type 5 pin suitable for 5 Amp 230 Volts all as specified and directed.
S&F switch Piano flush type 5 amp single pole one way 230 volts all as specified & directed.
S&F switch Piano flush type 15 amp single pole one way 230 volts all as specified & directed.
S&F ceiling rose of 65x50mm PVC/polycarbonate three terminal surface bakelite complete all as specifiend and directed.
S&F lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed.
S&F LED bulb of capacity 10 watts not less than 700 lumens output at 6500K colour temp, complete all as specified and directed.
S&F of LED Flood light, 100 Watt, IP - 66, Impact resistance - IK 07, colour temp- 5700 K, Class I in epoxy powder coated die-cast aluminium housing (ADC 12) in grey finish with aesthetically designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. M16 size gland is used for cable entry and provision for loopin-loopout.High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >140 lm/W and viewing angle of120° to ensure better uniformity. PC Lens with Asymmetric/symmetric light distribution and Toughened glass fixed to housing with 06 Nos screws. Integral electronic LED driver with APFC,lower THD, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV with built In SPD & other safety test as per IS 15885 Part-2/Sec 13 for wall or surface mounting using adjustable MS cradle of thickness 4 mm with SS angular dial for precise angular mounting of luminaire including neccessary PCC work reqd to make foundation base to install the luminaires complete in all respect & as directed.
Supply & Fixing LED light fitting 20 W batten for Retro LED Energy saving tube light , high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy efficient ready to use pack all as specified and directed.
Supply and fixing BLDC ceiling fans, 5 star rated by Bureau of energy with service value of not less than 8.40, (26W±10%) with or without remote, with rated speed 350 Rev per min, air delivery 220 Cum/min complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply complete all as specified and directed.
Supply & laying XLPE isulated, PVS sheated aluminum conductor, armoured cable, 1100 volts grade, cross sectional area 10 Sqmm 2 core laid through wall/ floors complete all as specified and as directed.
Supply & fixing MCB single pole 240 volt any rating from 6 to 20 amps with rupturing capacity 10 KA complete all as specified and directed.
Supply & Fixing MCB SPN, 240 Volts, 40 Amps breaking capacity 10 KA (type B curve) all as specified and directed
Supply & fixing sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI pipe 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways ,PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work,disposal of suplus spoil to a dstance not exceeding 50mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) complete complete all as specified and directed. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
VANI CONSTRUCTION (BID ID -3056483)
Deepak Saxena (BID ID -3057743)
mh enterprises (BID ID -3058222)
R N AGRAWAL (BID ID -3057838)
KASHI NATH BANWARI LAL (BID ID -3057783)
BHARDWAJ CONSTRUCTIONS (BID ID -3054622)
JWALA ELECTRIC CONTRACTORS (BID ID -3057386)
ARCHI ENGINEERS (BID ID -3054154)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .