Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 9 C 8 SECTOR 7 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 2 | Rejected-Technical R 233 6 SIR SYED ROAD 3 JOGABAI EXT OKHLA NEW DELHI DELHI 110025 | SOUTH EAST DELHI | DELHI | 110025 | Rejected-Technical NON-RESPONSIVE |
| 3 | Rejected-Technical 1 SHAKTI NAGAR JAMMU JAMMU KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | Rejected-Technical NON-RESPONSIVE |
| 4 | Rejected-Technical | Rejected-Technical NON-RESPONSIVE |
| 5 | Rejected-Technical 16 B KURLA INDUSTRIAL ESTATE NEAR SEVA SADAN ROAD NARAYAN NAGAR GHATKOPAR W MUMBAI MAHARASHTRA 400086 | MUMBAI SUBURBAN | MAHARASHTRA | 400086 | Rejected-Technical NON-RESPONSIVE |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
16 Sept 2020, 4:00 pmClosed
Er. K.K. Padotra
Office of the Deputy General Manager, JKPCC Ltd., Unit Mechanical, Rail Head Complex Jammu.
Supply, installation Testing and Commissioning of Fire Suppression FM-200, High Sensitivity Fire Alarm and Smoke Detection System at Data Recovery, Centre (DRC) at Gladni, Narwal, Jammu
2020_PWDJK_103580_1
e-NIT No. 38/MECH of 2020-21 Dt. 04-09-2020
Open Tender
Miscellaneous Works
Item Rate
35 days
JAMMU
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Financial Controller, JKPCC Ltd.
₹44,000
Yes
Dy. Gen. Mgr. Mech. Unit, JKPCC Ltd. Jammu
24 Sept 2020
4 Sept 2020
17 Sept 2020
4 Sept 2020
16 Sept 2020
10 Sept 2020
10 Sept 2020
Amount
GAS SUPPRESSION SYSTEM Supply installation testing & commissioning of UL (Underwriters Laboratories) listed and FM(Factory Manuals)approved and The Petroleum and Explosives Safety Organisation (PESO) Approved Cylinders, complete with valve assembly and including supervisory switch connection for monitoring cylinder pressure,a pressure guage with a safety burst disc ,electronic control head / Solenoid, pressure operated control, head, flexible hose, strap, NRV,Pressure Switch and a safety cap. (all accessories should be UL listed /FM approved with marking and from same OEM)
SERVER ROOM= Cylinder size as per manufacture's UL Listing/FM approval Cylinder filled with HFC 227ea (23 kgs approx. each) (One MAIN + One Standby)
UPS BATTERY ROOM= Cylinder size as per manufacture's UL Listing/FM approval Cylinder filled with HFC 227ea (56 kgs approx.each )
Supplying installation testing and commissioning of Brass chrome plated steel Discharge Nozzle (UL Listed/FM approved) caliberated as per Computer Generated Results etc. as required.
Supply, installation, testing and commissioning of Piping with ASTM sch. 40 pipe as per design requirment complete with required welding work with Required sizes making good the damages etc as reqd.
SERVER ROOM
UPS & BATTERY ROOM
Supplying fabrication and commissioning of Manifold complete for making header of gas cylinders.
Supplying, installation, testing and commissioning Pressure Switch for Manifold
Supplying, installation, testing and commissioning Supervisory Switch for System
Supply, Installation, Testing and Commissioning of Manual Abort Station (Pull Type)
Supply, installation, testing and commissioning of Manual Release Station (Pull Type).
Cable tray
Photoluminiscent Gas Release caution sign board complete with fixing arrangements
FIRE DETECTION AND ALARM SYSTEM
Supply, Installation, testing and commissioning of Addressable Extinguishant Control Panel for 4 extinguishant areas. First and second stage sounder output mandatory. The panel must have programmable gas release/ extinguishant delay and programmable output duration, remote manual release input. The panel must also have remote released pressure switch input and monitored abort input. (APPROVAL- ULlisted /FM approved.)
Supply, installation, testing and commissioning of Power Supply Unit for above detactor 230 V AC to 24 V DC 3 Amp. Power Supply should be with 24 hour
Supply , Installation , Testing and Commissioning of Addressable multicriteria smoke detector, Address Switch to programme the modules, complete as required as per specifications.
Supply , Installation , Testing and Commissioning of Addressable Heat detector, Address Switch to programme the modules, complete as required as per specifications.
Supply, Installation, Testing and Commissioning of Addressable Manual Call Point, Address Switch to programme the Manual Pull Station, complete as required as per specifications..
Supply, Installation, Testing and Commissioning of Sounder with 90 db output at 1 metre distance cum Strobe Lights with 110 cd as per specification complete as required with power supply.
Supply, Installation, testing and commissioning of Addressable control module for Hooter & Solenoid Activation, Address Switch to programme the modules, complete as required as per specifications. - UL Listed
Providing Electric Gas Release caution sign boards(24 V DC) for approved locations.
Supply, Installation, Testing and Commissioning of 2C x 1.5 sq.mm Fire Survival multistanded copper armoured cable.
4 Kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Discharge time minimum 8 Secs, Controllable discharge mechanism, Range minimum 3 Meters, Applicable on Class A,B,C and electrically started Fire, A Rating-1A, B Rating-13B, Leak Detection Tested, ISI and CE Approved with Manufacturer’s standard Warranty
4.5Kg, Gas Type Fire Extinguisher, Easy Weight Management, Used Unused Mechanism, Wheel Type Discharge, Discharge time minimum 8 Secs, Controllable discharge mechanism, Range minimum 1 Meter, Applicable on Class B,C & electrically started Fire, B Rating 13B, ISI & CE Approved with Manufacturer’s standard Warranty
DUMP TESTING
Cylinder size as per manufacture's UL Listing/FM Approval Cylinder filled with HFC 227ea (23 kgs approx.) for SERVER ROOM (Cylinder to be retained by the vendor after dump testing)
Rodent System
Supply, Installation, Testing & Commissioning of Master Console Capable of connecting to 12 sattleites complete as required and as per specifications.
Supply, Installation, Testing & Commissioning of Satellite units complete as required and as per specifications.
S/l of Wire complete as required and as per specifications.
Supply and fixing of Bracket Stand complete as required and as per specifications.
Water Leakage Detection System
Supply, Installation, Testing & Commissioning of Water Leakage Detection system by providing fitting of 4 zone panel with battery backup,hooter,sensor modules 4nos,sensing cable connecting to sensor modules and power cable 2 core 1.5 Sqmm shielded armoured as per site conditiomns. Complete job.
VESDA SYSTEM
ASPIRATION SMOKE DETECTION SYSTEM: consisting of :- a) SITC of Intelligent Aspiration Smoke Detection system with Single pipe inlet aspiration detector for Up to 5000 sq. ft coverage; Networkable over 2 core wire, Programmable Alarm Thresholds; Offline/online configuration capability; Instant Fault Finder; AutoLearn Smoke; AutoLearn Flow; Multiple Event Logging in separate logs; Event log – up to 18000 events. Alarm Threshold Setting Range: 0.005% - 20.00% obs/m (0.005 - 20% obs/mtr). Approvals- UL,FM, CFE, VdS, CE - EMC and CPD, EN 54-20. b) SITC of Power Supply units - UL approved power supply unit with 230VAC input and 18 to 29VDC output. The power supply unit has the indications for AC input Power.Power supply unit should have capacity to operate on battery backup in case of AC mains failure & should have built in charging circuit for batterys. c) SITC of Sampling Pipe having Smooth bore PVC Pipe 25mm Outer Dia & 19 to 21mm Inner Dia with all required accessories. d) SITC of 2 core twisted pair shielded cable for networking - 24 AWG Stranded (7x32) tinned copper conductor in suitable PVC conduit. e) SITC of Trunk Adaptor, Capillary Tube Connector, Capillary Tube, Capillary Sampling Point, Sampling point label red (complete set) for air sampling in room voids for area having false ceilings.(Complete Job)
CAMC of complete system for two years after sucessful completion of warraty period
NOTE:- 1) The Complete job includes Testing and Commissioning of complete system including Dump test . 2) Measurable quantities shall be paid as per actual on the approved rates within the estimated amount. 3) Any item not mentioned in the BOQ but found necessary for testing, commissioning and proper functioning of the system shall be deemed to be included in the BOQ and nothing extra shall be paid.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .