Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.2 CrAccepted-AOC 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | ₹1.2 Cr | L-1 | Accepted-AOC quoted lowest rates |
| 2 | L-1₹1.1 CrRejected-Finance 189 TEACHEARS COLONY THAKUR PLOT TAJBAG NAGPUR 440024 | NAGPUR | MAHARASHTRA | 440024 | ₹1.1 Cr | L-1 | Rejected-Finance Abnormally Low Quoted and rejected as per Tender conditions. |
| 3 | L-2₹1.2 CrRejected-Finance 3 4 JEEVAN DEEP BUILDING 10 PARLIAMENT STREET NEW DELHI 1 PH 011 43573493 9899713006 | ₹1.2 Cr | L-2 | Rejected-Finance Not the Lowest |
| 4 | L-3₹1.2 CrRejected-Finance D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | ₹1.2 Cr | L-3 | Rejected-Finance Not the Lowest |
| 5 | L-4₹1.4 CrRejected-AOC 37 1A MOMINPORE ROAD KOLKATA 700 023 | KOLKATA | MURSHIDABAD | WEST BENGAL | 700023 | ₹1.4 Cr | L-4 | Rejected-AOC rejected to being L4 |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
5 Aug 2024, 6:00 pmClosed
AGM (E-E)
S. V. Airport Raipur
Annual operation and routine maintenance contract for 3 X 300 TR AC plant i/c ancillary installations like AHU, cooling tower etc. and CMC of tower and cassette ACs, split type ACs, water coolers, RO water purifier, AHUs, UVGI and AOP cell system etc
2024_AAI_201435_1
AAI/RPR/AGM(E-E)/ARMO/E-NIT-3
Open Tender
Electrical Works
Item Rate
730 days
S. V. Airport Raipur
as per NIT criteria
6 documents required · 6 mandatory
₹1,120
Yes
₹3.4 L
Yes
24 Sept 2024
15 Jul 2024
7 Aug 2024
16 Jul 2024
5 Aug 2024
16 Jul 2024
16 Jul 2024 - 22 Jul 2024
Amount
Operation and daily / routine maintenance of HVAC system of 3 nos. X 300TR capacity in two shifts, including Sundays & holidays, national holidays by engaging of manpower as mentioned in the tender terms & conditions. System comprising of chillers cooling towers, all pumps, Terminal building AHU's, LT Panels, Control Panels, VFD's, BMS & Load manager system etc. including monitoring, recording of various parameters of HVAC system as per detailed specifications, terms and conditions of agreement as required. (Manpower as sepecified in Tender Document)
Job contract for Operation and daily / routine maintenance including comprehensive maintenance of central HVAC system (including low side & excluding high side) comprising of the following main components. The job includes attending to complaints, repairs/rectifications, supply & replacement of any required spares/accessories/parts consumables, rewinding works, periodic inspections, Schedule/ preventive/breakdown maintenance as per tender terms & conditions as required. (Excluding comprehensive maintenance contract for 3 X 300 Tr. Chillers) (Manpower as sepecified in Tender Document) Air Handling Unit of different capacity including control panels /instrumentation & all other accessories of following capacity - 33 Nos. Cooling Towers complete - 3 Nos Primary Chilled Water motorpump sets (15 HP) - 4 Nos Secondary Chilled Water motorpump sets (40 HP) - 3 Nos Condenser motorpump sets( 30 HP) - 4 Nos Makeup water motorpump set (3 HP) & starter panel and associated accessories-1 set VFD Drive for secondary motorpump sets-3 nos 2 kVA UPS (Numeric make) with Battery Bank-01 set Electrical Panel for HVAC system (All the incoming & outgoing cables are covered in the scope of work only for maintenance & fault finding. Replacement of defective cables is not covered in the scope of item)
First Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of single phase 1.5/2.0 TR (including star rated) split type air conditioners of different makes including stabilizer (wherever installed) of following capacity installed at different locations including providing all necessary consumables / spares & replacement of faulty compressor and carrying out complete preventive/ breakdown maintenance as required (Non Inverter Type AC- 17 Nos. + Inverter Type AC-77 Nos.) (15 numbers out of 93 shall be taken up by 01.08.2024) (Manpower as sepecified in Tender Document)
First Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of water cooler so fall makes (i/c bubbler type 6 nos. Oasis make & 16 nos. Usha make normal water cooler) and upto 150/150 liters. cooling/storing capacity at different locations including providing all necessary consumables and spares including replacement of faulty compressor with original make as required. (13 numbers out of 24 shall be taken up by 01.08.2024) (Manpower as sepecified in Tender Document)
First Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of industrial water purifiers(RO) of capacity 25 LPH at different locations including providing all necessary consumables and spares including replacement of Membrane(Once in a year), Carbon Filter (twice in a year) and sediment filter(every quarter) attending monthly servicing/overhauling of system, attending breakdown call as & when required, complete etc as required. (Manpower as sepecified in Tender Document)
First Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of Industrial water purifiers at different locations including providing all necessary consumables and spares including replacement of ,Carbon Filter (twice in a year), sediment filter( every quarter), UV Lamp etc. attending monthly servicing/overhauling of system, attending breakdown call as & when required, complete etc as required. (Manpower as sepecified in Tender Document) (Aqua Guard- 03 nos.)
First Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of domestic water purifiers at different locations including providing all necessary consumables and spares including replacement of ,Carbon Filter (twice in a year), sediment filter( every quarter), UV Lamp etc. attending monthly servicing/overhauling of system, attending breakdown call as & when required, complete etc as required. (Manpower as sepecified in Tender Document) (Kent RO-01 no., Havells-01 no.)
First Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of three phases 3.0 Tr Tower Type split type airconditioners of different makes following capacity installed at different locations including providing of all necessary consumables and spares & replacement of faulty compressor and carrying out preventive & breakdown maintenance as required. (Manpower as sepecified in Tender Document)
First Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of three phases 4.0 Tr Tower Type split type airconditioners of different makes following capacity installed at different locations including providing of all necessary consumables and spares & replacement of faulty compressor and carrying out preventive & breakdown maintenance as required. (Manpower as sepecified in Tender Document)
First Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of three phases 1.5/2.0 Tr Cassette type inverter airconditioners of different makes following capacity installed at different locations including providing of all necessary consumables and spares & replacement of faulty compressor and carrying out preventive & breakdown maintenance as required. (Manpower as sepecified in Tender Document)
First Year
Second Year
Dismantling of Existing single phase/three phase Split /Floor mounted Air conditioner units (all type) complete of different rating from existing site. Before dismantling the full gas to be pump down properly and refilling of holes, plastering, finishing the walls making good the same including shifting the removed airconditioning unit up to new loaction / store room as required.
First Year
Second Year
Installation testing and commissioning of Split A.C/Tower A.C(all type) of various capacity up to 4 Tones etc. including connecting the outdoor & indoor units using refrigerant pipeswith insulation (existing or new one as applicable), wiring ,leak testing of entire system, top up of refrigerant as required, minor civil works as per requirement.
Fist Year
Second Year
Job contract for routine maintenance including annual comprehensive maintenance of Air-cooler which includes replacement of khus once in the year, including rewinding of air cooler motor, pump, pipes as required etc. Scrubbing of Air Cooler body with emry /sand paper and double coat painting including applying red oxide etc. as required and quarterly cleaning of cooler sumps but excluding watering. (Manpower as sepecified in Tender Document)
First Year
Second Year
Job contract for routine maintenance including comprehensive maintenance of 4 x16.5 Tr capacity of Air-cooled package Air-conditioning unit of Blue star make, operated on 3 phase, 415V, 50 Hz AC (Manpower as sepecified in Tender Document)
First Year
Second Year
Job contract routine maintenance including annual comprehensive Maintenance of complete Ultra Violet Germicidal Irradiation (UVGI) system and Ultra Fresh Advanced Oxidation Plasma (AOP) Cell system technology installed in all 33 AHUs and Packaged AC. ( UVGI Lamp 108W-35 Nos., 83W-26 Nos. and associated Driver-33 Nos.) (AOP Cell 26W-78 Nos. and associated Driver-37 Nos.) (Manpower as sepecified in Tender Document)
First Year
Second Year
SHINRYO SUVIDHA ENGINEERS INDIA PVT. LTD.
SNOWMEX ENGINEERS LIMITED
Anoop Refrigeration
M/s AGFA
V Save Electronics Pvt Ltd
Supertech Engineers
CIS GLOBAL INFRATECH PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .