| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹2.5 L+₹14,224.13 (6.15%)Rejected-Finance | L2 | Rejected-Finance STOOD L2 | |
| 3 | L3₹2.8 L+₹47,602.87 (20.6%)Rejected-Finance DVC PARA MEMARI PURBA BARDHAMAN | MEMARI | PURBA BARDHAMAN | WEST BENGAL | L3 | Rejected-Finance STOOD L3 |
| Sl No | Description | Qty | Unit | ADHISHARM INDUSTRIALS L1 | KOUSHIK MONDAL L3 | SADHAN ELECTRICAL ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying and fixing 240 volt 32 A Sheet steel DP Main Switches on flat iron frame on wall.(Make Havells)(D-1,1/a) | 2 | Nos | 1,310 ₹2,620 Lowest | 1,375 ₹2,750 | 1,325 ₹2,650 |
| 2.00 | Supplying and fixing (2+12) way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make Legrand) (D-9,13) | 1 | No | 1,810 ₹1,810 Lowest | 1,950 ₹1,950 | 1,900 ₹1,900 |
| 3.00 | Supplying and fixing (2+8) way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make Legrand) (D-9,13) | 1 | No | 1,520 ₹1,520 Lowest | 1,620 ₹1,620 | 1,530 ₹1,530 |
| 4.00 | Supplying and fixing 240/415 V 40 A MCB Isolator on din rail of existing DBs and necessary connection.(Make Legrand) (D-5/6) | 2 | Nos | 358 ₹716 Lowest | 410 ₹820 | 375 ₹750 |
| 5.00 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (6-32A)(Make Legrand)(D-6/7) | 20 | Nos | 196 ₹3,920 Lowest | 275 ₹5,500 | 225 ₹4,500 |
| 6.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC(E-14/1/a-iv) | 5 | mtr | 199 ₹995 Lowest | 275 ₹1,375 | 225 ₹1,125 |
| 7.00 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC (E-14/1/a-iii) | 35 | mtr | 153 ₹5,355 Lowest | 180 ₹6,300 | 165 ₹5,775 |
| 8.00 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (E-14/1/a-ii) | 56 | mtr | 123 ₹6,888 Lowest | 145 ₹8,120 | 135 ₹7,560 |
| 9.00 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (E-14/1/a-i) | 20 | mtr | 105 ₹2,100 Lowest | 275 ₹5,500 | 125 ₹2,500 |
| 10.00 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 4 sqmm | 4 | Nos | 7 ₹28 Lowest | 10 ₹40 | 7 ₹28 Lowest |
Tender Value
Refer Docs
EMD Value
₹4,800
Closing Date
15 Jul 2025, 6:55 pmClosed
AE/AESDII/PWD
Office of the Assistant Engineer (P.W.D.) Asansol Electrical Sub- Division II Near Polo Ground Dist-Paschim Bardhaman PIN 713304
Repairing and renovation EI Work at Warders quarter and Chief Controller quarter incl. outside light cable of Asansol District Correctional Home,Asansol in the District of Paschim Bardhaman
2025_WBPWD_874387_1
WBPWD/AE/AESDII/eNIQ02/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Asansol
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,800
Office of the Assistant Engineer (P.W.D.) Asansol
8 Sept 2026
4 Jul 2025
18 Jul 2025
4 Jul 2025
15 Jul 2025
9 Jul 2025
9 Jul 2025
Amount
Supplying and fixing 240 volt 32 A Sheet steel DP Main Switches on flat iron frame on wall.(Make Havells)(D-1,1/a)
Supplying and fixing (2+12) way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make Legrand) (D-9,13)
Supplying and fixing (2+8) way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make Legrand) (D-9,13)
Supplying and fixing 240/415 V 40 A MCB Isolator on din rail of existing DBs and necessary connection.(Make Legrand) (D-5/6)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (6-32A)(Make Legrand)(D-6/7)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC(E-14/1/a-iv)
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC (E-14/1/a-iii)
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (E-14/1/a-ii)
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (E-14/1/a-i)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 4 sqmm
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switchfixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish i)Average run 6 mtr
Do-do-do on board
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWDSpecification Book – May 1991)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.(E-6/18-b)
Supply & Fixing 240 V, 2 nos. 6A, Piano key type switch & 2 nos. 6A, Piano key type Socket (Brand approved byEIC) on sheet metal switch board embedded in wall incl. S &F 200x150x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex coverand making necessary connections as required.(E-4/10-c,E-5/13-d,1&E-5/14)
Supply & Fixing 240 V, 1 no. 16A, Piano key type switch & 1 no. 16A, Piano key type Socket (Brand approved byEIC) on sheet metal switch board embedded in wall incl. S &F 175x150x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex coverand making necessary connections as required(E-4/10-c,E-5/13-c,1&E-5/14)
Supply and fixing of Starter for AC ( upto 2 Ton) (Make: North west/as per choice of EIC)
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board(D--13/20-a)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: i) By ISI-Medium GI pipe (G-1)
Excavation of soil for installation of Earth Electrode and filling & ramming.(G-1/2) i) For Morrum Soil
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required.(G-2/4-a)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection toequipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages(G-5/a-iv)
S&Delivery 4core 10sqmm PVC/Al/Armoured cable
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary without loop box
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting
Supplying and fixing compression type gland including finishing complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 4core 10sqmm
Painting of 9mtr longSteel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint a) 1st coat of synthetic enamel paint over the primer
b) 2nd coat of synthetic enamel paint over the 1st coat
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 25mm
Add GST @18% On total
Add LWC @1% On total
SADHAN ELECTRICAL ENTERPRISE (BID ID -6712592)
KOUSHIK MONDAL (BID ID -6719469)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .