Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹44.2 L+₹1.9 L (4.47%)Rejected-Finance OFFICE 2ND FLOOR MEHRA TOWER TIBRI ROADD GURDASPUR 143521 | GURDASPUR | PUNJAB | 143521 | L2 | Rejected-Finance Other then lowest | |
| 3 | L3₹46.5 L+₹4.2 L (10.00%)Rejected-Finance | L3 | Rejected-Finance Other then lowest | |
| 4 | L4₹47.6 L+₹5.3 L (12.5%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | JALANDHAR | PUNJAB | 144001 | L4 | Rejected-Finance Other then lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
2 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Addition/ alternation of bldg No P-2 at Bde, provn of overhead shelter for 03 x post Veh in MT area and certain other sanction works under AGE B/R-I, GE Gurdaspur.
2021_MES_490011_3
GE GSR- 52/ 2021-2022
Open Tender
Civil Works
Item Rate
240 days
GE Gurdaspur
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹88,000
10 May 2022
14 Mar 2022
9 Apr 2022
14 Mar 2022
2 Apr 2022
21 Mar 2022
60 days
Amount
Excavation in trenches n exc 1.50 m wide and n exc 1.50 m in depth and not exceeding 10 Sqm on plan for foundation, poles, stay, cable, pipe etc. including brick protection etc and getting out in soft/loose soil complete all as specified and directed.
Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
Excavation in post holes in soft loose soil ( or similar holes) each n. Exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth aroun, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc 50 mtr and making good surface.
Removing excavated surplus soil material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
Removing excavated surplus soil material exceeding 50m and n exc. 100m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level).
M&L for cement concrete 1:5:10 type E2 using broken brick 40mm graded coarse aggregate as in filling in sunken floor complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) in surface channels and drains all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in foundation, filling and mass concrete as in posts complete all as specified and directed.
M&L for providing precast cement concrete1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces
M&L PCC 1:2:4 type B-1as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including form work complete all as specified and directed.
M&L for providing, cement concrete 1:2:4 type B0 (using 20 mm graded aggrgate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as directed.
Material and labour reinforced cement concrete (Design mix) M-25 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. complete all as specified and directed.
Material and labour reinforced cement concrete (Design mix) M-25 (using 20mm graded stone aggregate) as in columns, pilllars, piers, posts and struts complete all as specified and directed.
Material and labour reinforced cement concrete (Design mix) M-25 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Material and labour reinforced cement concrete M-25 (Design mix), (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed.
S & F precast cement concrete 1:2:4 type B0(using 20 mm graded aggrgate) louvres and jallies, 25mm thick (mea sured solid),including all mouldings, frame and set in cement mortar 1:4 complete all as specified and directed.
Supply only integral waterproofing compound.
Demolition of brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but exceeing ashlar facings, dressed stone work and precast concrete articles.
M&L for brick work with old size fly ash bricks, straight or curved on plan exc 6m means radius built in cement and sand mortar 1:6 complete all as specified and directed.
M&L for brick work (except bricks) using old size bricks, straight or curved on plan exc 6m means radius built in cement and sand mortar 1:6 complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides and soffits (if any) of foundation & plinth beams and similar work, vertical or to batter for rough finished flat surfaces complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions (square, rectangular or polygonal) for rough finished flat surfaces of concrete complete all as specified and as directed .
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork to sides soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed.
Taking down chowkats or frame with shutter of size exc 1.50 Sqm but n exc 4.0 Sqm each (without taking off shutters from the frames) etc including cutting of holes for hold fast complete all as directed.
S&F 6mm thick heat absorbing glass, any size any description including securing glass in metal frames with beads fixed with brass screws complete all as specified and directed.
Material and labour TMT steel reinforcement bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, quality conforming to IS 1786 complete all as specified and directed.
All as per Srl item No 32 above but 6mm to 8mm dia complete all as specified and directed.
All as per Srl Item No 32 above but 5 mm dia and over upto and including 10 mm dia in stirups, spacers and binders complete all as specified and directed.
Supply and fix for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified and as directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and sections including distance pieces, cleats, base plates etc conforming Fe 410-W (Gde E-250) quality A complete all as specified and directed.
M&L mild steel plates square, cut or notched forming holes, without any attachment conforming to Fe 410-W Gde E-250 quality A complete all as specified and directed.
M&L for mild steel angle iron post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based currugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with L type or J type or cranked hook complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with L type or J type or cranked hook complete all as specified and directed.
M&L for galvanised, 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm specing straining bolts, including securing and tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed.
M & L for rendering 12mm thick in cement mortar 1:6 on fair faces of brick or concrete surfaces, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 12mm thick rendering in cement mortar 1:6 on other than fair faces of brick or stone surface, finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5mm thick in cement mortar 1:3 on ceiling of roof and soffits of roof beam surface finished even and smooth complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick or concrete surface, finished even and fair complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick or stone surface, finished even and fair complete all as specified and directed.
Taking down cement plaster of any description on brick walls etc including raking out joints, hacking for key scrubbing down with water and removal of rubbish off the premises where directed complete all as specified and directed.
M & L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces using WPC as per manufacturer instruction, surface finished even and fair complete all as specified and directed. (Note- WPC compound shall be measured and paid separately)
M&L for 75mm thick PCC 1:4:8 type D-2 (40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-0 using 12.50mm graded aggregate) using WPC as per manufacturer instruction, surface finished even and fair complete all as specified and directed.(Note- WPC compound shall be measured and paid separately).
M&L for 50mm thick PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in plinth protection/ path/ floor laid in alternate bays and finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for coloured joint free Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 over 25mm thick 1:2:4 type B-0(using 12.5 mm graded aggregate) complete all as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surface 350 to 450x 350 to 250x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M & L for dark shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but n,exc0.42 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M & L for dark shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but n,exc0.42 Sqm as in skirting, dado, risers, vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M & L for coloured chequered cement concrete tile 30cmx30cm x25mm thick in floors etc. set, jointed and pointed in neat cement slurry with grey cement and pigment to match, over 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for preparing of new wood & wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L for preparing new or previously untreated surface of steel any description over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxise primer complete all as specified and directed.
M& L for preparation of new plastered surface and applying three coat of white wash on ceiling complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coat of oil bound/ oil emulsion distemper over one coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls painting two coats of cement base paint and applying by mechanically spray machine gun complete all as specified and directed.
M&L preparation of new plaster surface and applying two coats of cement base paint on wall complete all as specified and directed.
M&L preparation of new plaster surface and applying two coats of cement base paint on wall all as spd upto height 12 mtr.
M&L for preparation of old plastered surfaces surface by complete removal existing treatment and applying two coat of cement base paint complete all as specified and directed.
S&F 110mm bore PVC SWR pipes single socketed in any length as in weep holes complete all as specified and directed.
Dismantling wall and ceiling boards ( fibre, pulp, insulation ,etc. ) or insulation boards/slabs/blankets, any thickness, including cover fillet complete all as specified and directed.
M&L for 4mm thick plain AC building boards fixed to timber frame work fixed with screws in ceiling, flat or sloping complete all as specified and directed. Make :- Charminar, Everest, Ramco.
M&L 2nd class hardwood plaint fillets, square, rectangular or tringular in section clean sawn, secured with rails or brads n. exc 3 sqcm complete all as specified and directed.
Dismantling of corrugated or semi corrugated AC sheeting, in roof coverings.
Dismantling timber scantlings 40 Sqcm and over in section, in any position complete all as specified and directed.
M & L for timber scantling of second class hard wood framed work as fixed (clean sawn) complete all as specified and directed
All as per srl item No 72 above but except timber second class hard wood.
M&L preparing surfaces of wood and wood based materials , new or old of any description and girth , not otherwise described and treated with creosote oil one coat complete all as specified and directed.
Taking down steel window/ ventilator of any size (without taking off shutters from the frames) etc. including cutting of holes for hold fast complete all as directed.
S&F steel window box type made of ERW tube hollow P section of size 60mmX25mm double rebated outer frame comprising double shutters i.e. guaged skelton & glazed, shutter frame of ERW tube P section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and FI 2mm thick welded/ screwed to frame for fixing of wire gauge including MS guard bars, fittings and fixtures welded to frame/ shutters as given below and all as shown on drg No. CEJZ/TD-1020/08 Sh 1/3 to 3/3 complete: :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). Note: Wire cloth, glass shall be measured and paid for separately
S&F Anodised aluminium powder coated frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Chief.
S&F Anodised aluminium grill(anodised transparent or dyed to required shade according to IS 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screws@ 200 mm centre to centre,including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening,all complete as per requirement and direction of Engr-in Charge.
S&F pressed steel frames 1.25 mm thick for door size of frame 165 X 60mm with double rebates including necessary fixing lugs, hinges, lock strike plate and filling of chowkats with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) and for filling of hold fast and tarring to inner surface (surface in contact with concrete/brick surface ) of chowkats and hinges complete all as specified and directed.
S&F 2nd class hard wood (Hollock) 35mm thick factory made plain paneled shutter (One panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 (Part-I) kiln seasoned chemically presure treated.
S&F 2nd class hard wood (Hallock) factory made glazed and skeleton shutters 35mm thick divided into square, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc , sizes of members of shutters as specified in SSR Part-I, Section 8 clause 8.24 (a) ; supplied and fitted to chowkats complete all as specified and directed.
S&F GI wire cloth, 0.56 mm nominal dia. of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F Sheet glass, 3mm thick ordinary quality, in squares, not exceeding 0.50 sqm in each pane glazing with oil putty/ beads complete all as specified and directed
S&F 4mm thick sheet glass frosted on one side and glazing in square exc 0.5 sq. m in each pane.
S&F Mild steel sliding door bolts 300mm long, plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts complete
S&F 125mm mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
S&F 100mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
S&F 300mm, mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed.
S&F 2.5mm dia of plain mild steel wire, galvanised class 3, including straining and fixing to wall, concrete or steel posts and/or to straining bolts as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified and as directed.
S&F machine cut Kota stone slab flooring 20 to 25mm thick over cement screed bedding 15 mm thick in CM 1:4 jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing (with bees wax polish) complete all as specified and directed.
S&F machine cut Kota stone slab 18 to 20mm thick in riser of steps, skirting, dado and pillar over cement screed bedding 10 mm thick in CM 1:3 jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing and polishing (with bees wax polish) complete all as specified and directed.
S&F of brass mortice lock, vertical type, size 100 mm 4 Levers omplete all as specified and as directed.
S&F Aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
S&F extruded brass handle 150mm long fabricated type polished
S&F extruded aluminium alloy handles 125mm long, fabricated type, anodised
S&F Aluminium anodised, barrel tower bolts 125mm length of extruded section .
S&F butt hinges of size 100mm, medium weight, cold rolled mild steel .
S&F factory made single extruted WPC( Wood Polymer Composite) solid door/window/Ceosetory windowa & other frames/Chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade),calcium carbonate and natural fibers(wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 grms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum,screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water/moisture proof and fire retardan and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engr-in-Charge.
S&F factory made single extruted WPC( Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin PVC polymer of K value 58-60(Suspension Grade),calcium carbonate and natural fibers(wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 grms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N(Face) & 900 N (Edge),minimum compressive strength of 50 N/mm2, modules of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water/ moisture proof and fire retardan and fixing with stainless steel butt bhinges of required size with necessary full body threaded star headed counter sunk S.S screws,all as per direction of Engr-in-Charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
S&F toughned glass 12 mm thick as in partitions automatic doors and similar work including cutting to shape,drilling holes required complete all as specified.
S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 for ornamental and intricate design.
M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm not exc 20cm girth in brick wall complete all as specified and directed.
Cutting opening in cement concrete walls with or without reinforcement (any description) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc and rubbish off the premises, n. exc. 50m complete all as specified and directed.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and directed.
Cutting holes into brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required Exc. half brick but not exc one brick.
M&L for applying a coat of bitumen primer for use in waterproofing and damp proofing treatment @ 0.30 Ltr /Sqm complete all as specified and directed.
S&F Vitreous china coloured WC italion finish pedestal pan with attached vitreous china flushing cistern push button type having dual flushing system of same colour including PVC seat cover same colour including cast copper alloy Jet chromium plated with PVC connection 15mm bore 450mm long with brass CP nuts complete all as specified and directed.
S&F health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metere long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&F wash basin, Vitreous China of size 580x450mm with full pedestal, coloured, flat back, wall hung basin, 15mm dia PVC connection 450mm long including brass CP nuts and all necessary inlet outlet connections complete all as specified and as directed.
S&F brass chromium plated bottle traps of 32mm bore for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and PVC waste pipe 32mm bore complete all as specified and directed.
S&F towel Rail 600mm long of stainless steel fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F toilet paper holder,coloured vitreous China, box type fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F stop valves 15mm bore dia, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure with screwed both ends for iron pipe or for union complete all as specified and directed.
S&F pillat tap 15mm bore dia, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F bib tap 15mm bore dia, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
M&L for cast iron floor trap 75mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F Cast iron soil, waste and vent sand cast pipes 75mm bore in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls/ laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece, single (single Y) equal or unequal of 75mm bore complete all as specified and directed.
S &F PVC (SWR) junction double, (double T), equal or unequal of 100mm bore provided with access door complete all as specified and directed.
S &F PVC (SWR) vent cowl of 75mm bore complete all as specified and directed.
S&F 32mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors all as specified and directed.
S&F 20mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors all as specified and directed.
S&F 15mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors all as specified and directed.
M&L for sail-glazed stoneware drain pipes 150mm bore laid in trenches and jointed as specified
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof in 100/110mm bore pipe all as specified and directed.
M & L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in bed to drain pipes 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M & L for cutting into existing manholes for connecting new drains 150mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required
E/M PORTION Taking down carefully aluminium/copper point wiring for light, fan, bell, socket of point complete fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc complete at site and making goods disturbed surfaces of walls, floors etc.
Taking down sheet metal enclosure for DB’s including MCB complete at site and making goods disturbed surfaces .
M&L Point wiring with PVC insulated, unsheathed multistranded copper conductor cable of size 1.5 Sqmm, FR through and including concealed PVC conduit with fittings and PVC insulated, unsheathed , stranded copper conductor cable continious earth wire of size 1.5 sqmm, FR, connected to common earth including modular sunken boxes for mounting of accessories including making good to the disterbed surfaces complete for one light point/fan point/ call bell point controlled by one, one way switch all as specified and directed. Note :- Qouted rate is deemed to be included cost of making good the disturbed surface by plastering/filling putty alongwith matching with the existing finish.
All as per item No 140 above but for one 5 pin socket outlet 5 Amps on independent board
All as per Srl item No. 140 above but one modular socket, 6A multipurposes 2 module on same board.
All as per item No. 140 above but with unsheathed multistranded copper conductor cable of size 2.5 Sqmm, FR and PVC insulated, unsheathed multistranded, copper conductor cable continious earth wire of size 2.5 sqmm, FR, connected to common earth for one modular socket 16A multipin 2 module on independent board complete all as specified and directed.
S&F modular switch, 1 module, one way 6A single pole complete all as specified and directed.
S&F modular switch one way 16 amps one module single pole complete all as specified and directed.
S&F modular socket , 2 module 6A 2/3 pin all as specified and directed.
S&F modular socket, 6A/16A multipin combined 2 module complete all as specified and directed.
S &F modular white cover plate with frame, 1/2 module complete all as specified and directed.
S &F modular white cover plate with frame, 3 module complete all as specified and directed.
S&F modular white cover plate with frame, 4 module all as specified and directed.
S&F modular white cover plate with frame, 6 module all as specified and directed.
S &F modular white cover plate with frame, 8 module complete all as specified and directed.
S&F lamp holder PVC body angle type including 9 watt LED bulb polycarbonate body complete all as specified and directed.
M&L ceiling rose, surface bakelite 65x50mm three terminal .
Supplying and fixed sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 8 way with 200 amps rated bus bar SPN double door complete all as specified and directed. Note : All the connection of incoming and out goiing wire in MCB will be made with thimbles with suitable size as directed.
Supplying and fixing sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 12 way with 200 amps rated bus bar SPN double door complete all as specified and directed. Note : All the connection of incoming and out going wire in MCBs will be made with thimble with suitable size as directed.
S&F MCB single pole 6 amps to 32 amps , 'B' series 10KA complete all as specified and directed.
S&F MCB single pole 6 amps to 32 amps , 'C' series 10KA complete all as specified and directed.
S&F MCB single pole and neutral 40 amps , C series 10KA complete all as specified and directed.
S&F MCB triple pole and neutral 40 amps , C series 10KA complete all as specified and directed.
M&L taking down sub main wiring any size and descriptipon all as directed
M&L for sub main wiring with two run of 4 sqmm single core multi stranded PVC insulated, unsheathed copper conductor of grade 1100 Volt , FR cable (red for phase and black for neutral) and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and 25 mm dia. & 4 sqmm copper multi-stranded conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete complete all as specified and directed. Note :- (a) The quoted rate by contractor is deemed to be included making good the disturbed surface by plastering/filling putty alongwith matching with the existing finish. (b) Three run of cable alongwith PVC conduit together shall be measured as single run.
M&L for sub main wiring with two single core multi-stranded PVC insulated, unsheathed copper conductor of grade 1100 Volt , FRLS cable of size 6 sqmm (red for phase and black for neutral) and including electrical grade PVC conduits of desired colour not less than 1.2 mm thick and 25 mm dia. & 6 sqmm multi-stranded copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth duly complete. Note :- (a) The quoted rate by contractor is deemed to be included making good the disturbed surface by plastering/filling putty alongwith matching with the existing finish. (b) Three run of cable alongwith PVC conduit together shall be measured as single run.
S&F surface mounting universal batten housing made of powder coated CRCA sheet suitable for upto 1x 18/20 W LED tube rod single sided fixed on and including 2 PVC square blocks complete all as specified and as directed.
S&F LED tube light 20W(single sided connection) ultra bright LED polycarbonate tubelight with very high efficacy suitable for fitting into existing/ new tube light batten housing complete all as specified and directed. Note :- The contractor will submit the LM-80 and LM-79 report from manufacturer to Engineer-in-Charge before incorporating the items in work.
S&F exhaust fan metal body AC single Phase 230/240 v of size 300mm sweep with louvers including cutting hole of suitable size complete all as specified and directed.
Taking down carefully ceiling fan complete fittings at site, depositing to MES storeyard for re-fixing complete all as directed.
M&L for hanging ceiling fan and connecting up and carriage from MES store yard including provision of cable from ceiling rose or connector to fan including replacement of one pair of canopy at the site complete all as specified and directed.
S&F modular fan regulator 2 module electronic type 5 step 100watt, 240 Volt and connecting complete all as specified and directed all as directed.
S&F GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5m long including MS clamps made out of MS flat iron of size 32mmx 5mm thick with nuts & bolts, washers complete and drilling of holes for nuts & bolts etc all as specified and directed
S&F LED street light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 15mm bore light grade GI pipe for protection of earth lead including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing all as specified & directed by Engr-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core laid in trenches/ ducts/ through pipes/ along the pole etcincluding taking out/down existing unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note :- Excavation earth work, brick protection and cushioning shall be measured and paid separately.
Supply and lay bricks sub class 'B' old size for protection of cable laid in trenches for under ground cable all as specified.
M&L sand cushioning in trenches using fine sand to under ground cable, laid in two layers before laying the cable & after laying the cable complete all as specified
M&L for cable protection GI tubing light grade fixed long the pole/along the wall of size 40 mm bore with necessary clamps including taking down exisiting unserviceable pipe all as directed.
Supply and installation hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 ton complete all as specified and directed. Make :- Blue Star/ Samsung/ Voltas.
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 volt to 250 volt with output voltage stabilizer at 230 volt accurancy of + 2.5% and capacity 3 KVA complete all as specified and directed.
Supply and fix MCB protected socket outlet suitable for 5/15 Amp and earth plug in and including sheet steel enclosure single pole and neutral, plastic cover plate complete with one No. 20A single pole MCB C series all as per Havells model No DBOX or of equivelent of indoasian/ standard.
Note: A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
talwinder singh and co
M/S GAGAN CONSTRUCTION CO
S S CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .