Chief Engineer(MI), Irrigation Department, Assam
O_O the CE (I) Assam Chandmari, Ghy-03
Bank Protection works for four points, Control Room-4 Units, Supply, laying Installation of delivery Pipes accessories including Surge Tanks for four points, Procurement of Pump sets Installation, testing and Commissioning, priming system, etc
2023_ID_31740_1
19_RIDF_XXVIII NABARD_2023-24 Date_17_07_2023
Open Tender
Civil Works
Item Rate
180 days
Biswanath
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,000
₹5.8 L
Yes
7 Sept 2023
21 Jul 2023
17 Aug 2023
21 Jul 2023
16 Aug 2023
24 Jul 2023
Amount
BANK PROTECTION ( Qnty for 4 Pts)
Item No.1:-Earthwork in filling in canal embankment, approach road, afflux bund, guide bund etc. to the designed section and grade by obtaining earth from outside borrow pits and filling in uniform layers not exceeding 15 cm thick including clearing light jungles, removing trees upto 15 cm dia. and uprooting roots and stumps from the seat of embankment and borrow pits area, including breaking clods to not more then 10 mm cube ramming, dressing, watering and roughening the seat of embankment, profiling etc. paying compensation of earth borrowed from private land if any, lead upto 30 M and lift upto 1.5 M complete as directed. (By head lead in sandy, clayey or loamy soil).
Item No.2:-Earthwork in excavation of deposited silt, sand and river debris from the seat of Guide Bunds /Afflux Bunds,etc. including clearing light jungle, removing tree upto 15 cm dia, and uprooting roots and stumps, etc, from the seat of Guide Bunds / Afflux Bunds, etc. including dressing, carriage of excavated earth and depositing the same in stacks at a distance not less than 80 M from the axis of the Guide Bunds / Afflux Bunds, etc. including bailing out of water where necessary upto depth below the existing ground level as mentioned in the approved drawing and complete as directed and specified.
Item No.3:-Collection of hard broken stone of size 13 mm to 38 mm from blasted boulder free from dust and dirt and foreign materials including stacking at quarry site, complete as directed.
Item No.4:-Collection of one man size 25 cm to 30 cm hard river boulder including stacking in measurable stacks of not more than 1.00 M height at quarry site and making payment of forest royalty etc, complete as directed.
Item No.5:-Carriage of boulders, gravels, metal screening, stacking in measurable stacks at site, complete as directed A) For Normal Road upto 25.00 KM
Item No.6:-Labour charge for spreading hard river gravel/broken stone of size 13mm to 38mm to the required thickness including ramming, dressing the seat before laying the materials as directed with lead up to 30m & lift upto 1.5m complete as directed.
Item No.7:-Labour charge for pitching with one man size boulder including dressing and ramming the seat to proper size and slope, pitching etc. with local carriage of boulders from a distance of 60 M with lift upto 3 M, complete as directed.
Item No.8;-Construction of 1.00 M x 1.00 M rectangular boulder sausage including supplying of materials with 25 cm to 30 cm size boulders collecting from a lead of 25 KM encased in 15 cm mesh of 8G hexagonal wire netting and filling the voids between the boulders with stone not exceeding 18 cm in size tied with 8G galvanized tying wire at 30 cm apart, laid in position as directed including necessary local carriage of materials, paying necessary forest royalty including providing 1 (one) no. of jati bamboo horizontal runner along the top of the sausage with vertical bhaluka bamboo post 1.20 M apart driven at least 0.60 M below ground and tying with sausage etc, all complete as directed.. With river boulder
CONSTRUCTION OF CONTROL ROOM ( Qnty for 4 Pts)
Item No. 1 : Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
Item No.2: Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing
Item No. 3: CC work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone aggregate of size 13 mm to 38 mm including curing, bailing out water with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
Item No. 4: Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works, complete as directed. (Measurement to be taken on the face area timbered). Column
Slab Steps
tie beam steps beam
Item No. 5: RCC work in slab, abutment cap and above abutment, pier cap, pedestals, dirt wall etc. in proportion 1:1½:3 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including necessary curing, dewatering etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately)
Item No.6 : Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying, complete as directed
Item No. 7: 125 mm thick 1st class brick nogged wall in cement mortar in prop 1:4 including racking out joints curing etc. complete as directed.
Item No. 8 : 12 mm cement plastering including clearing surface and curing complete as directed. Prop.-1:4
Item no 9.:-65 mm thick traced flooring with cement concrete in proportion 1:2:4 with broken stone aggregate of size 6 mm to 20 mm over one 1st class brick flat soling including sand packing of the voids in between the bricks, watering, ramming properly where necessary etc. complete and 12 mm thick cement plastering. Finishing on top trowelling, altering, curing, complete as directed. (Brick soling to be paid seperately).
Item 10: Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
Item No. 11 : Providing galvanized C.I. sheet roofing including supplying fitting and fixing necessary galved, screws / iron "J" hooks bolts and nuts and washers etc. complete as directed including cost of roof truss (measurement on net roof area) 0.63 mm thickness (24 B.W.G).
Item No. 12: Providing 0.63 mm thick glaved ridging including suplying and fixing with necessary glaved. Screw washer etc. (23 cm lapping).
Item No. 13 : Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint.
Item No. 14 :- Distempering two coats including painting two coats to batten with approved paint complete as directed.
Item No. 15:-Providing barge board of size 200mmx20mm with 1st class local Hollock/Bonsum Timber including fitting and fixing with necessary wood screws etc complete.
Item No. 16 :-Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary).
SUPPLY, LAYING AND INSTALLATION OF DELIVERY PIPES AND ACCESSORIES INCLUDING SURGE TANK ( Qnty for 4 Pts)
Item No.1:-Supply, fitting-fixing of Surge Tank of size 900 mm dia x 1250 mm long made of 4 mm MS plate with Raiser assembly of size 75 mm dia x 6.0 M long and S-bend of size 200 mm x 1600 mmL made of 4 mm MS plate including painting the above with one coat of synthetic enamel primer followed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified CC foundation by nuts & bolts of suitable size as per drawing & specification as directed.
Item No.2:-SUPPLY AND INSTALLATION OF DELIVERY PIPE & ACCESSORIES(Inclusive of Transportation/ Carriage of pipe & accessories from HQ to site (L S), Laying, Installation & Erection of pipes and accessories at site @ 25% on B above& Painting of pipes & accessories @ 20% on all items mentioned below under item no. 2: i) Fabricated GI bend , 125 mm x 90° (NIQ-1-2019-20) Gv.(C)
ii) Fabricated GI pipe, 125 mm dia x 3.00 M long (NIQ-1-2019-20) Gr.(C)
iii) Fabricated GI pipe , 100 mm dia x 1.20 M long (NIQ-1-2019-20) Gr.(C)
iv) CIDF Sluice valve, 125 mm dia (NIQ-2 of 2019-20)
v) CIDF Reflex valve, 100 mm dia (NIQ-2 of 2019-20)
vi) MS nut & bolt (assorted size) (CS for NIQ-1-2019-20) Gr.(A)
vii) MS washer, assorted size (CS for NIQ-1-2019-20) Gr.A)
viii) Rubber Gasket, 125mm dia (CS for NIQ-1-2019-20) Gr.(A)
ix) Black putty (CS for NIQ-1-2019-20) Gr.(A)
x) GI Flange, 125 mm dia (CS for NIQ-1-2019-20) Gr.(A)
Item No.3:-SUPPLY OF MISCELLANEOUS ITEMS i) Hacksaw blade
ii) Emery cloth
iii) Waste cotton
iv) W B grease
v) Steel brush
vi) Rubber gasket, 150 mm dia
vii) Nylon rope
viii) Manila rope
CONSTRUCTION OF SUPPORTING PILLARS ( Qnty for 4 Pts)
Item No. 1: Earth work in excavation of foundation of canal structures in all types of soil as per design and drawing dressing the foundation, shoring, etc. removing the surplus spoils by head load to a safe distance from the working place and depositing required spoils in uniform layers dressing, watering, breaking clods to not more than 10mm cube with compaction complete as directed at site (including bailing out stagnant water where necessary).
Item No. 2 : Soiling in foundation floor at all levels including filling interstices,ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
Item No. 3: C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
Item No. 4 : R.C.C. work in slab, abutment cap and above abutment, pier cap,pedestals, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering ,scaffolding etc. where necessary complete as directed.( shuttering, scaffolding will be paid separately).
Item No. 5: Centering and shuttering including propping etc. where necessary and removal of forms after completion of C.C. and R.C.C. works as directed complete (measurement to be taken on the face area timbered).
Item No. 6 : Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed.
Item No. 7: 12 mm thick cement plastering including clearing surface and curing complete as directed in prop. 1:4
Procurement of pump sets & Installation, Testing & Commissioning, priming system ( Qnty for 4 Pts)
Item No. 1 : Centrifugal pump set with 60 / 70 LPS minimum discharge at 10.35 Mtrs Head, working efficiently at head range (7.62 – 13.71) Mtrs coupled with 20 HP induction motor. Pump, Motor, Starter should be of reputed brand and as per IS Specification. MOTOR : Conforming to IS : 325 - 1978 1. Make : MARATHON/ LUBI/ Kirloskar/ Crompton/ Havells 2. Type / Model : Squirrel cage TEFC 3. HP : 20 HP 4. RPM : 1450 5. Supply Voltage / Phase / Cycle : 415 V ± 10% 3 PH/ 50 Hz 6. Class of Motor Insulation : F PUMP :- Conforming to IS : 6595 Part – I 1. Make : LUBI/ Kirloskar 2. Type : Horizontal Axially Split Casing 3. Model : LHC 125 -250/ UP-125/30 A 4. Size ( Suction X Delivery ) : 150 mm x 125 mm 5. Head Range :7.62 – 13.71 M 6. Pump Input : 10.81 KW 7. Efficiency at duty Point : 78 % STARTER SUITABLE TO RUN ABOVE PUMP SETS: 1. Make : BCH/ Havells/ Equivalent 2. Model : NASALLEM 3. Type : FASD 4. Relay Range : 13 – 21 A BASE FRAME : Best quality MS frame of required size and shape for complete pump set. COUPLING : Best quality coupling of required size suitable for the pump set
Item No.2 : Electric motor driven vacuum pump set, water ring type mounted on common base frame and coupled by means of flexible coupling capable of handling minimum 14 litre of free air per second ( 0.084 cubic metre per minute ) and to produce minimum vacuum of 600 mm of mercury ( approx. ) coupled with 3 HP , 440 / 400 V, 3 ph, 50 cycles Induction motor. The pump should have specific suction & delivery provided with vacuum gauge complete. Vacuum Pump set & Starter should be of reputed brand and as per IS Specification. MOTOR :- Conforming to IS : 325 - 1978 1. Make : MARATHON/ LUBI/ KSB/ Kirloskar 2. Type / Model : Squirrel cage TEFC 3. HP : 3 HP 4. RPM : 1450 5. Supply Voltage / Phase / Cycle : 415 V ± 10% 3 PH/ 50 Hz 6. Class of Motor Insulation : F PUMP :- Conforming to IS : 6849 1. Make : Stand-Hi-Vac/ Kirloskar 2. Type : Water Ring 3. Model : SWV -2 4. Size ( Suction X Delivery ) : 25 mm x 25 mm 5. Duty Range : 0.085 M3 / Min, 600 mm of Hg 6. HP consumed :2.46/ 3 HP STARTER SUITABLE TO RUN ABOVE MOTOR: 1. Make : BCH/ L&T/ Havells 2. Model : MLI 3. Type : DOL BASE FRAME :- Best quality MS frame of required size and shape for complete set. COUPLING :- Best quality coupling of required size suitable for the pump set
Item No. 3: Installation of Centrifugal Pump set (Horizontal Split casing type, size: 150 mm(suction) x 125 mm dia. (delivery) of 60 LPS minimum discharge at 13.00 Mt head coupled with 3 ph, 415 V, 50 Hz, 1450 RPM squirrel cage induction motor of 20 HP complete set. The job includes necessary transportation of pump set to the site and installation of C.C. block foundation in proper position with accurate alignment by means of foundation nuts and bolts complete with all works.
Item No. 4: Fitting, fixing and laying of G.I. Pipes with Accessories: Laying, fitting, fixing and connection of suction pipe line for each pump set with 150mm dia. G.I. pipes of different length, fabricated G.I. pipes with different length, fabricated bends, tapper including foot valve for suction side. Reflex valve, sluice valve for delivery side of each pump set with 125mm dia. G.I. pipes with different length, bends, fabricated G.I. pipes with different length as per drawing. The joints should be with the best quality pipe joining sets of required size comprises of 60mm thick black moulded rubber gasket, necessary nuts, bolts and washer. Every joint should be leak proof and should be completed in all respect from foot valve to the pump flange for suction side and fr4om delivery flange is the water flow through at proper F.S.L for the delivery side. The pipes lines with accessories must be proper painting.
Item No.5: Providing, fitting , fixing and erection of pipe supports for each pipeline at on interval of 3.00 Mtr. (approx) made of M.S. channel (ISMC 75) 1.50 Mtr. height with angle bracing erected on CC block of size 0.45mX0.30mX0.60m below ground.
Item No.6: Installation of Electric driven Vacuum pump set water type mounted on common base frame and coupled with flexible coupling capable of handling minimum 2.20 Lt of air/sec and to reduce minimum vacuum of 600 mm of Hg pressure with 5 to3 HP, 440V,3ph,50Hz induction motor set with starter (Amp range-7.5A) mounted on common base frame on suited C.C. base foundation bolts of required size. Also installation and connection of wall mounting type sub panel board ( readymade sheet enclosure with make)suitable for the motor of vacuum with necessary frame and clamps and fitted with the components, 1) MCB (3 ph,415 V,50 Hz,25 KVA, 16 Amp) 2) Voltmeter (0-500 V) 4) Electro switch for Voltmeter 3) Ammeter (0-25 Amp) 5) Induction lamp (R-Y-B) The job should be included connection of the components with the motor through the starter with best quality PVC insulation sheeted copper conduction cable of appropriate gauge.
Item No.7: Supply and compressing of graphite greased gland packing of reputed quality as required quantity around the rotating shaft of the pump set against the gland pressure plate to form a water tight seal and adjusting with the help of gland nut in order to accommodate continuous operation .
Item No.8: Laying and connection of cables such as Feeder cable, priming motor cable, lighting cable etc. ii) 25 sqmm x 3 ½ core
Construction of 11/0.43, 25 KVA Pole mounted Sub-Station including complete commissioning of the scheme (Line Length=400 Mtr) ( Qnty for 4 Pts)
Item No.1:-Surveying and finalising the suitable tapping point in existing nearby 11 kV line in consultation with APDCL and Departmental Officers, marking the alignment of the line considering Right of Way, Feasibility etc. as required and as directed. For 1st 500 M
Item No.2:-Jungle cutting including cutting of branches of trees and reclining Bamboos along the alignment of the overhead line providing clearance 1.5M either side and above the line as directed. Clearance must be ensured at the time of charging the line
Item No.3:- Supplying & Erection of PSC Pole conforming to IS 1678 of Standard Dimension and of following lengths for overhead Electric Lines including digging of Earth Pit (0.75m × 0.5m) to a depth ⅕th of the Pole Length with a PCC Base Plate of size 60 cm × 60 cm × 12 cm at the bottom, refilling as specified with hard ramming as directed. (I) Refilling with Hard Soil. 9.75 M.
Item No.4:-Supplying and erection of MS Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with Clamps, Nuts & Bolts duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed
Item No.5:-Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of MS Angle of size 50 mm × 50 mm × 6 mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with MS Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed
Item no.6:-Supplying and Erection of 11 kV HT Stay Set comprising of 19mm dia × 1.8 m Stay Rod, Anchor Plate, Bow, Thimble etc. including supply and erection of 7/10 SWG G I Stay Wire and 11kV Guy Insulator complete including digging of Earth Pit of size (0.9m × 0.9m) to a depth of 1.4 Metre, placing the Stay Rod with Plate, fixing thimble, bow etc. with Boulder packing (size 150mm to 200mm) and hard ramming to fill up half the pit and filling with hard soil packing upto the Ground Level as directed
Item No.7:-Supply and erection of G I Stay Wire 7/10 SWG along with 11 kV Guy insulator, binding to existing 11kV Stay Set and the GI Pole Clamp, tightening to required extent as directed.
Item No.8:-Supplying and Erection of Hardware Fittings (3u bolt) on existing MS / GI Channel Cross Arm with GI Nuts and Bolts for mounting 11 kV Disc Insulator 45 kN as directed
Item No.9:-Supplying and Erection of 11 kV Polymeric Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed
Item No.10:-Supply and Erection of 11 kV Grade Aero Bunched Cable with 3(three) Power core, Stranded compacted, Circular Aluminium Conductor screened with black extruded semi conducting compound natural colour XLPE insulated core screened with black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC and one Bare messenger wire shall be stranded non-compacted circular aluminium alloy conductor. the cable should conform to IS:8130-1984, IS:398(Part-IV) 1994, IS:7098(Part-II) 2011 & IS:5831-1984 with up to date amendments. The job includes necessary Cable Joint, End Terminations, Anchor Clamp, Supension Clamps, Eye Hooks etc as directed by department. iii) 3 x 95 sqmm(P) + 1 x 70 sqmm (M)
Item no.11:-Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of MS Angle of size 50 mm × 50 mm × 6mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with MS Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed
Item No.12:-Supplying, Fitting and Erection of 3-φ 11 kV Gang Operated (G.O.) Air Break Switch having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(Part-III) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed. 400 Amps
Item no.13;-Supplying and Erection of 3-φ 11 kV Drop Out (D.O.) Fuse Unit rated voltage 11 kV R.M.S. To 12 kV R.M.S., highest System Voltage 12 kV, each pole consisting of Polymeric insulator, all current carrying parts made of a highly conductive copper alloy and contact portion are silver plated for corrosion resistance and efficient current flow and the fuse tube made of fibre glass coated with ultraviolet inhibitr on the outer surface and having Arc Quenching bone fibre liner inside conforming to IS 9385/1983 of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed. (150 amp)
Item no.14:-Supplying and Erection of Metal Oxide gapless Lightning Arrestor of following specification on MS Channel with Clamps, Nuts & Bolts including drilling of holes and making of necessary connection with Line Conductors as directed. 9 kV, 10 kA with Polymer body
Item no.15;-Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed
Item no.16(i):-Supply including Erection of 4 Star ON-AN (Oil Natural, air Natural) Cooled Al/ CU-wound Distribution Transformer conforming to IS specifications 2026 (with latest amendments) with all standard accessories erected on double pole structure/ transformer pad including transportation and handling, loading and unloading etc,, securing it on existing Channel firmly with necessary clamps, nuts & bolts . as required, and making necessary connections on HV and LV sides as directed (Cost of DP structure /Pad extra ) Capacity : 25 kVA, 11 kV/0.433 kV (4 Star Dyn) (A) Cost including Supply of Transformer
Item no.17:-Supply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed. 6 SWG G.I. Wire
Item No.18:-Supply & Erection of Anti Climbing Barbed Wire on Poles at a height of about 3 Metres and covering a length of 1.5 Metre as directed
Item No.19;-Supplying including erection of powder coated LT Feeder Panel for 25 kVA DTR (800mm × 1000mm × 400mm) made of 16 SWG CR sheet and 40mm × 40mm × 6mm MS angle having CR sheet roofing containing Cu Busbar and 1 no 63 A 415 V FP MCCB, making necessary connection through copper cable complete as directed.
Item No.20:-Supply including Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 35 Sq mm × 3 core in single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of tren ch of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5cm + 7.5cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed
Item No.21:-Danger plate suitable for 11KV line conforming to IS:2552/1963 of size 200mmX200mm
Item No.22:-Providing Security fencing around the S/S with GI chain link net, woven with 10 SWG wire with mesh 7.5cm × 7.5cm to be erected on GI angle 40 mm × 40mm × 5mm, with necessary C C grouting, with a fencing height of 1.8 mtr, having a hinged door, fabricated with flat GI strip boundary and cross bracing, complete including supply of all materials, excavation refilling etc as reqd and as directed.
Item No.23:-Testing and commissioning of the Substation alongwith obtaining necessary approval for charging from competent authority including payment of Inspection Fee, Arranging for Test Report etc. as required and as directed for following kVA Capacity
Item No.24:-Liasoning with APDCL, Forest Department, Electrical Inspectorate etc. right from start till commissioning of the HT Line/ sub-station, preparation of all necessary documents like Agreement and Affidavit reqd. for power connection, obtaining No Objection Certificate from Forest Department where necessary to complete all arrangement for charging the installation as reqd. and as directed.
Item No.25:-Testing and commissioning of the 11KV Line including making necessary inspection fee and obtaining charging approval from competent authority making requisite payment of Inspection Fee to the APDCL/ Electrical Inspectorate, arranging for Test Report etc. as reqd and as directed. upto 1 kM
Item No.26:-Erection & Commissioning LT Whole Current Electronic Energy Meter including making necessary payment to APDCL for Meter Cabinet, Meter Security etc as reqd and as directed.
Item No.27:-Load Security to be paid to APDCL (Approx.)
LT control panel ( Qnty for 4 Pts)
Item no.2:-Supplying, fitting, fixing of LT Power Capacitor, 415V, AC, 3 Ph (single unit) of 6KVAR rating and making connection with Bus-bar in the existing panel. The capacitor is to be placed in existing platform.
Item No.3_ Supplying, fabrication and erection of Iron Angle Stand for erection of LT Power Capacitor made of MS Angle of size 30 mmX 30mm X5 mm with 4 Nos of legs 400mm high and cross pieces having Bakelite Sheet horizontal platform as directed Size of Frame: (300mm X 300mm) x 400mm
Item No.4:-Supplying including fitting, fixing and connection of TPN Main Switch (SDFU- Switch Disconnector Fuse Unit) with HRC fuses, 415V AC, Open Execution, Panel Mounting type of following rating in already fabricated Control Panel Board housing , along with lugs, connecting cable and all other necessary materials as directed, 100 Amps
Item No.5:-Supplying including fitting, fixing and connection of three pole 415V, AC 50 Hz Motor Protection Circuit Breaker (MPCB) with adjustable thermal and magnetic setting with rotary handle of following current/HP ratings in already fabricated LT Control Panel Board housing along with lugs, connection cable and all other necessary materials for connection as directed.
Item No.6:-Automatic Star Delta Starter: Supply including fitting, fixing & connection of Automatic Star-Delta Starter in sheet steel housing for 3-ph, 415 V AC squirrel cage motor of following current rating including fitting, fixing of angle iron frame/clamps and all other necessary materials for connections as directed, 20 HP
Item No.7:-LT CABLE TERMINATION with brass compression glands and Al . lugs Providing End Termination of PVC/XLPE insulated Al. conductor, armoured LT power cable, 1.1kV grade, of following sizes with brass compression gland and Aluminium lugs along with supply of all materials as required and as directed.. Size of Cable: 25 Sq.mm X3 Core for Starter Connection: a)Cost of Cable
Item No.8:-EARTHING Supplying and erection of Pipe Earth Station including supply of all materials with GI Pipe of following size perforated all over the body with 12mm dia hole at standard spacing with necessary reducing socket , locking arrangement with hinge cover plate, funnel, GI nuts& bolts etc with necessary enclosure on the top including excavation and refilling as directed. i) 40mm dia X2.5 Mtr long GI Pipe along with salt and charcoal
Item No.9:- SAFETY MATERIALS: i) Chequered Sheet (1.18M X 0.9M X 10mm)
ii) Supplying, laying and making connection of 6 SWG Copper Earth Wire making earth connection to Control Panel Board, Motors & Starters etc as directed.
ii) Porcelain cut-out, 200 Amps.
iii) Fuse wire 100 A
iv) Rubber Hand Gloves for 11 KV Line work
v) Hand held digital Insulation Tester with LCD display with voltage ranges 50 V/100 V/ 250 V/500 V/ 1000 V and insulation
vi) Manual Crimping tool with Dies 10 mm² to 95 mm²
vii) 11 KV Hook Stick with Fibre body 6 mtr long and of approved quality
viii) Transportation
Item no.10:- Miscellaneous Electrical Items
i) TPN Main Switch (SDFU - Switch Disconnector Fuse Unit) Wall Mounting Type Supplying including fitting, fixing & connection of TPN Main Switch (SDF) with HRC Fuses, 415 V AC, in Sheet-Steel Housing of following current ratings to be fitted in existing Angle Iron Frame/Wall with Clamps, Nuts & Bolts and all other necessary materials as directed including drilling of holes as required.
ii) emery paper (smooth)
iii) Waste cotton (CS for NIQ-1- of 2019-20 Gr. A)
v) 11KV Pin Insulator (Porcelain)
vi) MS nuts & Bolts (Assorted size)(CS for NIQ-1- OF 2019-20 GR.A)
vii) MS washer (Assorted size) (CS for NIQ-1- OF 2019-20 GR.A)
viii) GI Wire 6 SWG (CS for NIQ-1- OF 2019-20 GR.A)
Construction of P.V.C. distribution system ( Qnty for 4 Pts)
Item No. 1: Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
Item No. 2 Supplying fitting fixing of P.V.C. pipe (IS 12818, 4kg/cm2 ) , joining pipes with relevant cement ,levelling , testing leakages etc. complete as directed .(Cost of earth work foundation trenches will be paid separately) A) 160 mm dia
B) 110 mm dia
Item No. 3:- Supplying, fitting ,fixing , P.V.C. unequal Tee (Prince- brand)joining with pipes with solvent cement, testing leakages etc. complete as directed.
Item No. 4:- Supplying, fitting ,fixing , P.V.C. Reducer (Prince- brand) joining with pipes with solvent cement, testing leakages etc. complete as directed.
Item No. 5:- SSupplying, fitting, fixing, joining of PVC end cap fitting with solvent cement as per specification including local carriage, testing leakage etc. complete as directed.
Construction of Spout Chamber ( 15 Nos.) for 4 pts
Item No. 1 : Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. In ordinary soil
Item No. 2 : C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
Item No. 3 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)
Item No. 4 : 12 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4 Inside Outside
Item No. 5 : Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed.
Item No. 6 : Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed. 110 mm / 90
Item No. 7 : Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately). 110mm dia
Construction of Sign Board ( Qnty for 4 Pts)
Item No. 1 : Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed. (As per approved rate of SE)
RAJIB LOHIA - KHEMSA TRADERS AND DEVELOPERS JV
DEEPAK KUMAR BUCHA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .