| 1 | L1₹69,796Accepted-Finance 59 16 RAM NAGAR ROTI GODAM KRISHNAPURI MATHURA MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-Finance Ok | |
| 2 | L2₹1.1 L+₹41,204 (59.0%)Accepted-Finance | L2 | Accepted-Finance Ok | |
| 3 | L3₹1.3 L+₹59,204 (84.8%)Accepted-Finance 00 SHREE BALAJI ENTERPRISES TUBEWELL KE PASS BARWALA NAGAUR RAJASTHAN 341505 UDYAM RJ 35 0016306 | NAGAUR | RAJASTHAN | 341505 | L3 | Accepted-Finance Ok |
| Sl No | Description | Qty | Unit | SHREE BALAJI ENTERPRISES L3 | MEERA GYAN ENTERPRISES L1 | VASU ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | To attend SF-6 Gas leakage of 145KV SF-6 CB (CGL make S. No. 4859C, Type-120-SFM-32B) a. Direct Pole leakage by SF-6 Gas leakage detector. b. Extract SF-6 gas from pole units by help of SF-6 gas extraction plant and keep it into empty SF-6 gas cylinder. c. Dismantle all top covers from pole units and opening of fixed contact chamber from pole unit. d. Cleaning of all fixed & moving contacts, polishing the contacts and applying micro carbon grease on contact surface. e. Replace pole top cover O ring P-170, absorbant and re-fitting the same. f. Apply vaccum in all poles by held of vacuum pump upto specified value and keep it for 4/5 hour & check no loss of vacuum. g. Complete overhauling of spring charging mechanism assembly, cleaning & lubrication. h. Dismantaling of close & trip coil assembly, opening its parts, cleaning, lubrication and adjuctment of air gap of this plunge. i. Checking electrical connection in the marshalling box and tightening all electrical connection. j. Check close / trip operation of this breaker satisfactorly. k. Check Close / Trip timing by digital timer | 1 | Job | 64,500 ₹64,500 Lowest | 64,898 ₹64,898 | 71,000 ₹71,000 |
| 2.00 | Replacement of Main NRB with pipeline (if required) work consist of dismantling of main NRB with pipeline & replace it with new one & fitting at its original place in CB SF-6 gas filling in all poles at desired level for satisfactorly completion of work. | 1 | Job | 64,500 ₹64,500 | 4,898 ₹4,898 Lowest | 40,000 ₹40,000 |
Tender Value
₹1.3 L
EMD Value
₹2,000
Closing Date
29 Oct 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
ETD Firozabad
Overhauling of 145KV SF6 CB of CGL make at 132KV SS Shikohabad under ETD Firozabad
2025_UPTCL_1083111_1
ET-15/ETD(F)/2024-25
Open Tender
Electrical Works
Lump-sum
ETD Firozabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer
₹2,000
15 Nov 2025
16 Oct 2025
29 Oct 2025
16 Oct 2025
29 Oct 2025
16 Oct 2025
16 Oct 2025 - 29 Oct 2025
To attend SF-6 Gas leakage of 145KV SF-6 CB (CGL make S. No. 4859C, Type-120-SFM-32B) a. Direct Pole leakage by SF-6 Gas leakage detector. b. Extract SF-6 gas from pole units by help of SF-6 gas extraction plant and keep it into empty SF-6 gas cylinder. c. Dismantle all top covers from pole units and opening of fixed contact chamber from pole unit. d. Cleaning of all fixed & moving contacts, polishing the contacts and applying micro carbon grease on contact surface. e. Replace pole top cover O ring P-170, absorbant and re-fitting the same. f. Apply vaccum in all poles by held of vacuum pump upto specified value and keep it for 4/5 hour & check no loss of vacuum. g. Complete overhauling of spring charging mechanism assembly, cleaning & lubrication. h. Dismantaling of close & trip coil assembly, opening its parts, cleaning, lubrication and adjuctment of air gap of this plunge. i. Checking electrical connection in the marshalling box and tightening all electrical connection. j. Check close / trip operation of this breaker satisfactorly. k. Check Close / Trip timing by digital timer
Replacement of Main NRB with pipeline (if required) work consist of dismantling of main NRB with pipeline & replace it with new one & fitting at its original place in CB SF-6 gas filling in all poles at desired level for satisfactorly completion of work.
VASU ENTERPRISE (BID ID -5636231)
SHREE BALAJI ENTERPRISES (BID ID -5635529)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_1983892.xls
BOQ • 0.27 MB
Part1.pdf
Tender Documents • 1.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .