Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.5 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹12.9 L+₹11,673 (0.91%)Rejected-Finance A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹14.2 L+₹1.4 L (11.1%)Rejected-Finance | 3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹14.6 L
EMD Value
₹30,000
Closing Date
9 Sept 2021, 6:00 pmClosed
AGE (I) Fatehgarh
AGE (I) Fatehgarh
CERTAIN B/R REPAIRS INCL JOINERY, FALSE CEILING, ROOFS, FLOORING, WALL PANELLING AND MISC WORK IN OTM ACCN OF SLI ADM AREA AND TRG AREA UNDER AGE (I) FATEHGARH.
2021_MES_467576_1
GE/FAT/ET-28 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹30,000
Yes
30 Sept 2021
12 Aug 2021
11 Sept 2021
12 Aug 2021
9 Sept 2021
27 Aug 2021
12 Aug 2021 - 26 Aug 2021
Amount
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, complete all as specified specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exc 1.5 sqm not exceeding 4 square metre each, complete all as specified specified and directed.
Taking down shutter of any description exc 1 Sqm and n. exc 2.0 sqm each complete all as specified specified and directed.
Taking down shutter of any description not exc 1 Sqm each complete all as specified specified and directed.
Taking down door shutters of any description exceeding 1 sqm and not exceeding 2 sqm each and refixing the same after easing and adjusting/resizing complete all as specified specified and directed.
S&F Rolled sections as in framing for cladding, glazing, for door chawkat frame and the like fixed with angle cleats and connecting plates, etc conforming to Fe 410-W (Gde- E- 250) quality- A etc complete all as specified specified and directed.
S & F Mild steel Framed work such as grills,gratings, etc.. with ends of bars houldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 confirming to Fe 410 - O or Fe 310 - O complete all as specified specified and directed.
S& F for 35mm thick, factory made, 2nd class hardwood, Plain framed, panelled shutter (two panel)(single/Double leaf) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified specified and directed.
S&F for Factory made, 35mm thick, 2nd class harswood Glazed and skeleton shutters (single/Double leaf), open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. complete all as specified specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall bw covered with heat moulded plain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for tip rail & bottom rails; Panelling of plain colour PVC sheet to be fitted in the MS frame weloded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement. suppling and fixing in the frame at site as per specification & drawing specified in ssr part-II 2020.
Soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm palin colour PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing specified in ssr part-II 2020.
S & F in repair for block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face as in shelves of cupboards, alongwith beading of 2nd class hardwood of size 19mm x 2mm, fixed with screws to timber frame work, complete all specified and directed.
M&L in repair for 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination as in shutters of cupboards, fixed with screws in repairs, complete all specified and directed.
S & F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all specified and directed.
S & F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all specified and directed.
S&F steel ventilators with top hung shutter incl hinges steel peg stay, complete all specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all specified and directed.
S&F Mild steel sliding door bolts 250mm, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all specified and directed.
S&F Aluminium handle 125 mm long cast type anodised, complete all specified and directed.
S&F Aluminium tower bolt 150 mm long, anodised barrel tower bolts of extruded section complete all specified and directed.
S&F Mild steel pressed handles 125mm size, oval type, stove enamelled black, complete all specified and directed.
S&F Mild steel barrel tower bolts 150mm, stove enamelled black,with barrel of extruded section and fixed complete all as specified.
S&F Aluminium floor door stopper (150 mm long) of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified
S&F M.S. helical door spring (150 mm long) including roller and roller plate complete all as specified
S & F Butt hinges 100 mm medium weight cold rolled Mild Steel complete all as specified and directed.
S&F Sheet glass, ordinary quality 3.00 mm thick not exceeding 0.5 sq m in each pane (in single/double /triple storey bldgs), in steel/wooden window with cleat/oil putty as per site requirement complete all as specified.
S&F in repari sheet glass, ordinary quality 3.00 mm thick not exceeding 0.5 sq m in each pane (in single/double /triple storey bldgs), in steel/wooden window with cleat/oil putty as per site requirement complete all as specified.
Hasp and staple, 100mm size, safety type, aluminium anodised including bolt to hinge plate and fixed with screws, complete all as specified.
S & F in repair Aluminium (Extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in reapir, complete all as specified.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water, etany thickness or any descritiion or in any position etc complete all as specified and directed.
Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and directed.
M&L of brick work with sub class 'B' burnt bricks straight or curved on plan exc. 6 m mean radius bult in CM 1:6 complete all as specified and directed.
M&L for Rendering of 15mm thick cement plaster in cement mortar (1:4) on on fair faces of brick work or concrete and mix with water proofing compound and finished as per manufacturer instruction even and smooth (without using extra cement) complete all as specified. Note:- (WPC shall be measured & paid separetaly)
M&L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finished even and fair without using extra cement, complete all as specified and directed.
S&F in repair 25mm dia Harrison rails, anodized aluminium alloy, chromium plated with fixing brackets, stops, rollers etc, complete all as specified and directed.
M&L for preparation of new or previously untreated surface of wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new or previously untreated surface of steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint etc complete all as specified and directed.
M&L for two coats of cement based paints incl preparation to newly plastered surfaces of walls etc complete all as specified and directed.
M&L incl preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting etc complete all as specified and directed.
Supply only liquid water proofing compound.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S & F coloured hollow PVC Wall Lining 6 to 8 mm thick including fixing on wall and providing PVC beading/L Section all around of lining complete all as per specifications and drawing specified in SSR part-II 2020
M & L for 6mm thick Non asbestos fibre cement building boards both side laminated fixed to frame work in ceiling flat or sloping, to GI snap grid frame work Size of grid 605 x 605mm for false ceiling including Hangers 2 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of rowl plug of suitable size complete all specified and directed.
Dismantling floor, hearth or wall tiling of any description, any position including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all specified and directed.
M & L for Glazed ceramic tiles in vertical surface 450 x 350x 7mm thick coloured tiles, set and jointed in neat cement slurry and pointed in white or colour cement to match, 10 mm thick rendering on fair faces of concrete surface of verticle in CM (1:3) finished even and smooth without using extra cement complete, shade & design as approved by EIC/GE, incl rubbish off the primises etc complete all specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match,over15 mm thick screed bed in cement mortar (1:4) in floors, incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed.
M & L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over Screed bed or bedding layer in CM 1:4 of 15 mm thick for laying floor finishes etc complete all as specified and directed.
M/S WASEEM KHAN CONTRACTOR
M/S SRI JAGDAMBE TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .