| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹32.0 L+₹3.3 L (11.4%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹32.5 L+₹3.7 L (13.0%)Rejected-AOC | L3 | Rejected-AOC Other than L1 |
Tender Value
₹34.0 L
EMD Value
₹68,000
Closing Date
2 Apr 2024, 6:00 pmClosed
Garrison Engineer(North) Akhnoor
Garrison Engineer(North) Akhnoor PIN 181201 CO 56 APO
REPAIR/MAINT OF STORAGE TANKS, CLEANING OF UG SUMP, DUG WELL, PUMPING INSTALLATIONS, OHT, PAINTING WORKS AND CONNECTED ITEMS AT SUNDERBANI UNDER GE (NORTH) AKHNOOR
2024_MES_644611_1
CANO- GE(N)/AKH-65/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Sunderbani
Class D Cat a i
8 documents required · 8 mandatory
₹500
GE (North) Akhnoor
₹68,000
Yes
9 Sept 2024
29 Feb 2024
4 Apr 2024
29 Feb 2024
2 Apr 2024
14 Mar 2024
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for. Note :- (a) Demolition of slab of semi UG Sump will be done with proper safety precautions, scafolding, covering of well/Sump with proper steel shuttering including steel posts/ struts and rate for the same shall be deemed to be included with quoted rate for the item and nothing extra shall be admissible on the account to be included for steel complete all as specified and directed.
Form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete, complete all as specified and directed.
Form work to sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs etc and similar works fair finished complete all as specified and directed.
Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to better with rough finished surfaces of concrete complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of square rectangular or polygonal concrete all as specified and directed.
Form work to fair faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters,buttresses etc vertical or to better with fair finished surface of concrete complete all as specified & directed.
Reinforced cement concrete Design Mix (M-25) using (20mm graded crushed stone aggregate) as in beams cantilivers bressumers etc complete all as specified.
Reinforced cement concrete Design Mix (M-25) (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and as directed.
Reinforced cement concrete Design Mix (M-25), (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
Reinforced cement concrete Design Mix (M-25) (using 20 mm graded crushed stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and as directed.
Reinforced cement concrete Design Mix (M-25) (using 20mm graded crushed stone aggregate) as in wall, retaining wall, basement wall, blast walls and the like, any thickness above top of footings including attached pillasters and buttresses, complete all as specified and directed.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified.
Demolition of cement concrete (un-reinforced) as in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
75mm thick PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection laid in bays complete including finishing the surface of concrete topping even & fair, complete all as specified.
Taking down old unsv roof treatment including PCC padding if any, plastering, removing existing bitumen felt treatment including brushing, cleaning top surface of roof slab, brooming etc and removing rubbish off the premises complete all as specified and as directed.
Plain Cement concrete type B-0 1:2:4 (12.5mm graded crushed stone aggregate) as in roof kerbs or mud stops, in floors, plinth courses, protection for interlocking of paver blocks rounded or chamfered on edges complete all as specified and as directed.
Roof treatment :- (a) Apply a coat of bituminous primer conforming to IS - 3384 @ 0.40 Kg/Sqm on prepared surfaces. (b) After drying of primer apply a coat of hot blown 85/25 penetration grade blown bitumen conforming to (IS-702 @ 1.20 Kg/Sqm of surfaces. (c) Provide APP modified polymeric five layered membrane with central core of 100 micron high molecular high density film. Minimum weight of APP modified water proofing membrane shall be 3 Kg per Sqm. Product Name Multi plus manufactured by M/S STP texa Ltd Gurgaon/Hyper Plus Standard Manufactured by IWL India ltd Chennai, Bengal Acquaflux manufactured by Bengal bitumen New Delhi/Superior plus 310 by STP Lfd and any other product as appproved by E-in-C Br will be used. APP membranne will be laid across the slop from lowest line of slopping roof toward ridge with minimum end lap of 150mm and side lap of 75mm bonded with hot blown.
Srl item No 18 contd (d) Over the APP membrane apply semi hot blown 85/25 grade bitumen penetration of bitumen when tested as perIS 1203 will not be more than 40/Confiming to IS 702 @ 1.20 Kg/Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bvitumen coat. (e) Coved fillet in PCC (1:2:4) type BO radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall around opening and treatment mentioned above (except fine sand) shall be applied followed by a cement plaster 20mm thick in CM 1:6. (f) Two coats of Aluminium paint over membrane shall be provided as per manufacturer instructions. Note : (i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only.
Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed.
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed.
Description all as per item No 21.00 here-in-before but except bricks.
Rendering 15mm thick cement plaster with cement mortar (1:6) on fair faces of brickwork or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Rendering 15mm thick cement plaster with cement mortar (1:4) on fair faces of brickwork or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick on external wall surfaces (ht not exc 3.5m from ground level) in cement mortar 1:4 finished fair and even without using extra cement as in roof projection/chajjas/facia incl soffit of chajjas using GI wire netting 0.90mm dia and 12mm mesh lathing, complete all as specified. Note : (i) Rate quoted are deemed to incl double scaffolding. (ii) Wire netting shall be measured and paid seperately.
Supply only GI wire mesh 0.90mm dia and 12mm mesh all as specified and directed.
Preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified.
Preparation of newly plastered / unplastered surfaces of wall including cornices pilaster etc, and applying two coats of cement base paint over and including one coat of cement primer, complete as specified and directed.
Preparation of old painted surfaces by washing, rubbing down and stopping and applying one coat of cement base paint white or other tint on wall complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Preparation of old plastered surfaces of ceiling and apply one coat of white wash, complete all as specified and as directed.
Preparation of old steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as speciified and directed.
Mild steel angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc). Including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or lying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc, (each line wire to be measured) fixed in repair complete all as specified
Framed mild steel work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410W Gde-E-250 complete all as specified and directed.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plate confirming to Fe 410W(Gde E-250), quality 'A' complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as speciified and directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as speciified and directed.
PCC 1:2:4, B-1 (20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified.
Plain Cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundation filling and mass concrete, complete all as specified directed.
Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), including all fittings, heads , shoes bends , swan-necks etc. complete all as specified and as directed.
PVC SWR 110mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed.
Taking down and refixing in the same position of Rolling shutters of any size and in any position making functional by way of repairs of ball bearing and spring and greasing included in the rate quoted complete and making good the surfaces complete all as specified and as directed by Engr-In-Charge
Excavation in trenches, n.exc. 1.5m wide and n. exc 1.5m in depth, for foundation, etc and getting out in any type of soil, complete all as specified and directed.
Returning, filling incl spreading leveling watering and well ramming in layers n exc 25 cm thick each layer complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware) of 150mm internal dia set in cement mortar including demolition of concrete bed and haunching and removal of rubbish off the premises complete all as specified and directed.
Reinforced concrete pipes 150mm dia, class NP3, laid and jointed with collars, complete all as specified and directed.
Plain Cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) of 150 mm dia as in concrete bed to drain pipe incl packing under, and hunching against the side of pipe after they are laid and tested all as specified and directed.
Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for including removing the rubbish off the premises all as specified and directed.
Reinforced cement concrete 1:2:4, B-1 (Using 20mm graded crushed stone aggregate) as in manhole covers slab/shelves etc including necessary form work for fair finished surfaces complete all as specified and directed.
Cleaning of internal wall/floors of RCC over head reservoir of Capacity 75000 Gallon including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste by opening wash out valves and applying caustic soda solution and one coat of lime wash internally including cement base white wash of complete OH tank to the external wall, bottom surface, pillar and painting of raising main pipe line and delivery line by black paint and writing work with one coat of synthetic enamel paint as per colour code mentioning (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank etc, complete all as specified and as directed. NOTE :All precautionery measure such as safety belt, climbing rope, scaffolding etc to be taken by the contractor to safeguard human life while working on overhead reservoir. The rates quoted for the item shall be inclusive of the same.
Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and directed.
Rolling and consolidating of soling of broken boulders not exceeding 15cm thick with power roller exc 5 tonne and nexc 8 Tonne, complete all as specified and directed..
Hardcore of broken stone or boulder of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick, watered and rolled/rammed to a true surface, complete all as specified and directed..
Cleaning of internal walls for underground or semi underground sump located at Stage II, Pump House of Capacity 50000 Gallons. The work also includes washing with clean water and bleaching powder including scraping with wire brush on walls and floors & removing mud and grits & deposits properly to a distance not exceeding 50 Mtr. including applying cement base white wash to external wall and painting of raising main pipe line and delivery line by black paint and Writing the date of cleaning and Next due date of cleaning on a rectangular box of size 75cm x 50cm, wriing in white colour on black back as directed all as specified and as directed.
Chlorine testing kit complete with test tubes, solution complete all as specified and directed.
Testing of water from the approved govt lab and testing the following perameter of water :- PH range, Total solids, total hardness, Floride, Nitrites, Nitrates, Lead Arsenic, Ammonia, Chlorides, Cadmium, Cyanide, Mercury Iron, Management, Surphate, Phernolic and submission the report to Deptt or as directed by Engr-in-charge Note :- Sample of water shall be collected by the Contractor, in presence of medical staff / MES staff and empty containers collection sample bottle shall be provided by the contractor.
Machine pressed concrete interlocking paver block any shape, size and colour confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment over sand cushion complete all as specified and directed. Note:- Sand cushioning shall be measured & paid seperately.
Sand filling under floors or in foundation laid in layers 25mm thick including watering and consolidation for laying inter locking tiles, complete all as specified and directed.
Supply only chlorination chemical highly efficient (high strength) calcium based granular(65 to 70% chlorine content) disinfectant more stable than chlorine gas/bleaching powder high stable in sealed container for water treatment stability projected shelf life of chlorination of chemical must be one year with min loss of chlorine ISI marked as approved. Note:- The contractor has to produce manufacturer test certificate and purchase voucher from authrozied dealer for every lot of item of calcium based granual for the verification of genuineness of material. No material is accepted without test certificate.
Supply and fixing in replacement “Lithium based Energy Efficient Integrated Solar Street Light of 24 Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 53/55Wp , Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. CAT part No- SOLAR AIO 24 W of Make Havells or equivalent cat part of Make as specified in list of make here in after as spproved by GE.
Material and labour for painting and writing letters "SAVE WATER" in Black letter size 36"X18" on dome of over head water RCC tank and UG Sump , writing tank capacity and date of cleaning and due date of cleaning in capital letters of 80 mm size on external surface of wall with white synthetic enamel paint over black background of any capacity over head tank and UG Sump all as directed. NOTE :All precautionery measure such as safety belt, climbing rope, scaffolding etc to be taken by the contractor to safeguard human life while working on overhead reservoir. The rates quoted for the item shall be inclusive of the same.
Supply and fixing Glow sign board of size 4' x 3' made of flex glow sign board sheet reactangular shape having lighting arrangement of superior quality ,showing installation Nomenclature as approved marked all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours.
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary , gusset plates, riveting etc n exc 10 Kg each brackets, conforming to Fe-290. Gde E-165 (Brackets over 10 Kg each to be measured under "Structural Steel") Complete all as specified and directed. Note-Quoted rate shall also include cost of fabrication and fixing at site.
Taking down old unsv Non-return valve and Supply and fixing Non return valve 150mm dia heavy duty both ends flanged ISI marked class PN 1.6 complete with nuts, bolts washers etc complete all as specified and directed.
Supply, Fixing and Fabrication of distribution header of size 250 mm dia MS pipe, min length -5 mtr , dead end from both side with blind plates duly bolted including welding work to cut pieces/ pipes made to shape for taking out number of incoming / Outgoing branches flanged type as given below with suitable sluice valves incl nuts bolts, washer, welding, bending, drilling holes for bolts in any shape or size as directed inclusive of one primer coat of red oxide primer, one under coat and finish coat of synthetic enamel paint as desired complete including brick work with plastering 1:6 cement mortar to support the header above ground level and necessary PCC work/ hard standing all around complete all as specified and directed. Note : Rate for made to flanges, Tee, Elbow fitting etc are deemed to be included in the quoted rates. (a) Nos of Incoming- 01Nos, size- 150mm outlet (b) Nos of Outcoming- 04 Nos, size- 150mm outlet (c) Nos of Outcoming- 01 Nos, size- 100mm outlet
Supply only sluice valve class PN 1.6 of size 100mm dia complete all as specified and directed.
ASIA ENTERPRISES
M/s Mool Raj Ramesh Chander
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .