Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹43.7 L+₹10,100 (0.23%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance Other then lowest | |
| 3 | L3₹44.7 L+₹1.1 L (2.54%)Rejected-Finance | L3 | Rejected-Finance Other then lowest |
Tender Value
₹40.8 L
EMD Value
₹81,600
Closing Date
20 Jan 2024, 6:00 pmClosed
CWE Rajouri
HQ CWE Rajouri PIN 900129 C/o 56 APO
PROVN OF 100 KVA TRANSFORMER AND LT DISTRIBUTION PANEL AT 14 PUNJAB UNDER GE 862 EWS
2023_MES_634120_1
CWE/RAJ-46/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 862 EWS
As per Tender Documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹81,600
Yes
11 Mar 2024
22 Dec 2023
25 Jan 2024
22 Dec 2023
20 Jan 2024
6 Jan 2024
Amount
Material and labour for high tension lightning arrestor, expulsion type suitable for 11 KV with all fittings of transmission class, discharge capacity 65 Kilo Amps and testing all as specified and directed.
Supply and fix, 11 KV air break gang operated device of rating 400 amps, 3Pole, vertical type, mechanically operated, mounted on and including 11 KV porcelain insulators and steel frame with operating machanism worked from ground level with and including GI tubing 25 mm bore light grade and providing ACSR conductor jumpers duly claimped with lugs, connected to existing 11 KV supply and testing complete all as specified and directed.
Supply and installation of 100 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed copper wound outdoor type step down transformer complete with first filling of ISI marked transformer oil of required dielectric strength and other standard fittings / accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector group DYn-11. Standard fittings/accessories to be supplied alongwith transformer :- Name, Rating & Diagram Plate – 01 Set, OFF circuit tap changing switch - 1 No, Earthing Terminals - 2 Nos., Lifting lugs - 2 Nos, Oil Level Indicator - 1 No, Oil Drain valve with Plug - 1 No, Oil filter valve with plug - 1 No, Conservator with oil filling hole with cap 1 No, Thermometer pocket - 1 No, 4” dial type thermometer stem type - 01 No, Air release plug - 1 No, Silica gel breather - 1 No, Explosion vent -1 No, Bidirectional C.I. rollers- 4 Nos, Arching horn set (HV side) - 3 Nos. Note : Above transformer specification ref. IS : 1180-2014 and should be of level 2.
Supply, install, testing & commissioning of servo voltage stabilizer (outdoor type) of 100 KVA Capacity for automatic controlling/regulating operation of voltage comprising of auto transformer, copper wound with new transformer Oil of required dielectric strength, servo motor, auto controlled solid state control circuit and other fittings & accessories as under:- Voltmeter (0-500 V) to read input/output voltage per phase, Mains/Low/High limit Indicators, Manual Increase/Decrease Push Switch, Auto/Manual mode control switch and output adjustment. Three phase neutral oil cooled designed for input variation between 300 v to 480 v with output voltage stabilized at 415 V with accuracy ±2.5% and speed of correction 8 volts per second, including suitable platform as reqd on site. Complete all as as specified & directed.
Supply and erecting of true vertical position steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing complete all as specified and directed. (Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch 'A').
Supply and fix aluminium conductor, steel reinforced (ACSR) of following size as in overhead conductor including fixing aluminium tapes for binding and line connectors, complete all as specified and directed: - 6/1 x 3.0 - Ferret Note: The weight of the conductor shall be determined as stipulated in Preamble (b) on Page No. 419 of SSR-2020 Part-II (Rates).
Supply and fixing, disc type insulators, porcelain vitreous white brown or green, 145 mm high and 255mm dia ball and socket type, two-in-series assembly for tension with tension clamps for conductor having working pressure 11000 Volts complete all as specified and directed.
Supply and fix in replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed.
Stay assembly complete with accessories and GI stay rod 20 mm dia 1900 long, stay plate 300mm x 300mm x 6mm, galvanised thimbles, GI stay wire 7/4 SWG, galvanised steel 14mm dia 400mm long stay bow and GI nuts, washers including loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No 1 on MES Schedule Part-I complete all as specified and directed. Note : Stay clamp, excavation and earth work and concrete for stay pit and insulator shall be measured and paid separately.
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-290 Gde E-165 including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of red oxide primer coat and two coat of silver paint all as specified and directed.
Supply and fixing factory made out door type LT Panel totally enclosed and both side opening with locking arrangement of suitable size 415V 3 phase 4 wire having 250 Amp electrolytic copper bus bar made out of 3.15mm CRCA sheet duly powder coated enamelled paint over one coat of red oxide primer and suitable for fixing following complete with PCC work by providing 60 cm long angle iron of size 50x50x6mm above ground level welded on all the fuse corners duly comprising of the followings :- INCOMMING :- (a) MCCB 160Amp Four Pole 36KA.-01 No (b) Ammeter Digital type(0-200A) - 01 No (c) Voltmeter Digital type(0-500V) - 01 No (d) CT's - 03 Nos (e) Indicating lamp LED type - 03 Nos (f) On Load Changeover 160 Amp FP-01 No OUTGOING :- (a) MCCB 63Amp Four Pole 25KA.-03 No (b) MCCB 40 Amp Four Pole 25KA.-01 No (c) 32 Amp ,SPN MCB of 10 KA Rupturing capacity"C" Series-04 Nos
Material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earths tripe 32 X 6 mm size by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as specified & directed.
All as item No. 13 above but with 4mm dia GI wire as earth continuity conductor complete all as specified & directed
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables all as
Excavation in trenches not more than 1.5 mtr wide and exc more than 1.5 mtr depth for foundation for erection of poles, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed by Engr-in-Charge.
PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for yard installation complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
PCC 1:2:4 (nominal mix) type B1 using 20mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed.
Material & labour for GI tubes, "light grade", 80 mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection, complete all as specified and directed. Note: Excavation and earth work shall be measured and paid for separately.
Material & labour for GI tubes, "light grade", 50 mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection, complete all as specified and directed. Note: Excavation and earth work shall be measured and paid for separately.
Supply, laying, testing and commissioning HT cable 11 KV grade, XLPE insulated (earthed) screened, PVC bedded, galvanized iron strip armoured with stranded aluminium conductor cable of cross sectional area 95 sqmm, 3 core, ISI marked with IS:7098 (part-II) as amended upto date in trenches/ ducts/ through pipes etc and making connection by providing suitable copper lugs with proper crimping, complete all as specified and directed
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100V grade with aluminum conductor of size 120 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100V grade with aluminum conductor of size 70 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100V grade with aluminum conductor of size 50 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100V grade with aluminum conductor of size 25 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100V grade with aluminum conductor of size 16 sqmm 2 core complete all as specified and directed by Engr-in-Charge.
vijay kumar gupta and co
M/S JIWAN SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .