Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹4.2 L+₹41,459 (11.1%)Rejected-AOC 56 C 2 BIDHANNAGAR ROAD KOLKATA WEST BENGAL 700067 | KOLKATA | KOLKATA | WEST BENGAL | 700067 | L2 | Rejected-AOC Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹4.4 L+₹63,831 (17.0%)Rejected-AOC DESHBANDHU PARA ENGLISH BAZAR JHALJHALIA MALDA WEST BENGAL 732102 | MALDA | MALDA | WEST BENGAL | 732102 | L3 | Rejected-AOC Quoted rate found 3rd Lowest (L3). | |
| 4 | L4₹4.6 L+₹85,431 (22.8%)Rejected-AOC | L4 | Rejected-AOC Quoted rate found 4th Lowest (L4). | |
| 5 | L5₹4.8 L+₹1.1 L (28.2%)Rejected-AOC RAJA SARAT CHANDRA ROAD PURATULI ENGLISHBAZAR DIST MALDA PIN 732101 | MALDAH | WEST BENGAL | 732101 | L5 | Rejected-AOC Quoted rate found 5th Lowest (L5). |
| Sl No | Description | Qty | Unit | DEBNATH ENGINEERING WORKS L1 | BANERJEE ENTERPRISE L2 | M/S. M. R. ENTERPRISE L4 | P N RURAL ELECTRICALS L3 | KALPANA BHATTACHARJEE L7 | ARGHYA BHATTACHARYA L5 | S.G.ENTERPRISE L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying and fixing 415V, 160A TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl.S&F 3nos.DIN type HRC fuse as per rating.(Make: L&K / Siemens / ABB)(PWD/GS, Page No.: D4 item no. b). | 2 | Nos | 9,000 ₹18,000 | 6,223 ₹12,446 Lowest | 11,050 ₹22,100 | 17,000 ₹34,000 | 17,080 ₹34,160 | 17,070 ₹34,140 | 8,650 ₹17,300 |
| 2.00 | Supply of 1.1 KV grade 4 core 95 sqmm. PVC/alluminium armoured cable. ( LT Panel busbar to Main switch and Main switch to Main switch) (Make: Havells / Polycab / RR Kabel) | 281 | Mtrs | 950 ₹2,66,950 | 1,185 ₹3,32,985 | 1,250 ₹3,51,250 | 950 ₹2,66,950 | 1,030 ₹2,89,430 | 1,010 ₹2,83,810 | 457 ₹1,28,417 Lowest |
| 3.00 | Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.
(PWD/GS, Page No.: F3 item no. 4/a ) | 240 | Mtrs | 120 ₹28,800 | 99 ₹23,760 Lowest | 110 ₹26,400 | 130 ₹31,200 | 210 ₹50,400 | 180 ₹43,200 | 387 ₹92,880 |
| 4.00 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
(PWD/GS, Page No.: F2 item no. 2/b) | 24 | Mtrs | 172 ₹4,128 Lowest | 178 ₹4,272 | 190 ₹4,560 | 320 ₹7,680 | 365 ₹8,760 | 340 ₹8,160 | 2,985 ₹71,640 |
| 5.00 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
65 mm dia
(PWD/GS, Page No.: F6 item no. 11/e ) | 17 | Mtrs | 416 ₹7,072 Lowest | 431 ₹7,327 | 510 ₹8,670 | 750 ₹12,750 | 795 ₹13,515 | 790 ₹13,430 | 859 ₹14,603 |
| 6.00 | Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core
(PWD/GS, Page No.: F1 item no. 3/b ) | 17 | Mtrs | 80 ₹1,360 | 62 ₹1,054 | 50 ₹850 Lowest | 130 ₹2,210 | 195 ₹3,315 | 180 ₹3,060 | 3,500 ₹59,500 |
| 7.00 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 4 core 95 sqmm XLPE/PVC armoured cable.
(PWD/GS, Page No.: F4 item no. 7/c ) | 8 | Each | 300 ₹2,400 | 242 ₹1,936 Lowest | 350 ₹2,800 | 350 ₹2,800 | 444 ₹3,552 | 420 ₹3,360 | 1,800 ₹14,400 |
| 8.00 | Finishing the end of 4/3.5 core 95 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
(PWD/GS, Page No.: F5 item no. 8/b ) | 8 | Sets | 310 ₹2,480 | 321 ₹2,568 | 295 ₹2,360 Lowest | 340 ₹2,720 | 440 ₹3,520 | 410 ₹3,280 | 1,000 ₹8,000 |
| 9.00 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with topcover plate and 2no.suitable size “Ph&N” copper bar & earthing attachment fixed on wall incl.mending good damages to original finish.
Average Run: 6 mtr
(PWD/GS, Page No.: E24 item no. 1b ) | 4 | Pts | 950 ₹3,800 | 830 ₹3,320 Lowest | 905 ₹3,620 | 1,400 ₹5,600 | 1,550 ₹6,200 | 1,520 ₹6,080 | 1,175 ₹4,700 |
| 10.00Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make: Legrand / L&T / Seimens / ABB / Schneider) | ||||||||||
Tender Value
Refer Docs
EMD Value
₹10,040
Closing Date
24 Nov 2025, 12:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Laying of cable to supply power to NTS Fire pump room at Nursing Training School, Malda Medical College and Hospital, Malda under Malda Electrical Division, PWD
2025_WBPWD_938424_1
WBPWD/EE/MED/e-NIQ-32/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,040
7 Jul 2026
4 Nov 2025
26 Nov 2025
4 Nov 2025
24 Nov 2025
10 Nov 2025
Supply of 1.1 KV grade 4 core 95 sqmm. PVC/alluminium armoured cable. ( LT Panel busbar to Main switch and Main switch to Main switch) (Make: Havells / Polycab / RR Kabel)
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. (PWD/GS, Page No.: F3 item no. 4/a )
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make: Legrand / L&T / Seimens / ABB / Schneider)
4 way (Up to 160A)
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make: Legrand / L&T / Seimens / ABB / Schneider)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make: Legrand / L&T / Seimens / ABB / Schneider)
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate will have to be submitted during delivery of the material.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tendernotice_2.pdf
PDF • 2.93 MB
Tendernotice_3.pdf
PDF • 0.24 MB
BOQ_2215199.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .