Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-Finance NO 85 NADU STREET JARI KONDALAMPATTI SALEM 636010 | SALEM | TAMIL NADU | 636010 | ₹4.2 Cr | L1 | Accepted-Finance Accepted |
| 2 | L2₹4.2 Cr+₹3.8 L (0.90%)Accepted-Finance NAMAKKAL 637 001 | NAMAKKAL | TAMIL NADU | 637001 | ₹4.2 Cr+₹3.8 L (0.90%) | L2 | Accepted-Finance Accepted |
| Sl No | Description | Qty | Unit | ARAWIND CONSTRUCTIONS L1 | Namakkal Constructions L2 |
|---|---|---|---|---|---|
| 1.00Open Earth work excavation for foundation with all leads and lifts in all soils and sub soils and to the required depth as may be directed except hard rock requiring blasting inclusive of shoring strutting and bailing out water wherever necessary refilliing the sides of foundation with excavated earth in layers of 15 cm thickness well consolidated depositing the surplus earth in places shown and levelling the site with all intial leads and lifts etc complete complying with relevant standard specification. | |||||
| 1.01 | Initial lead of 10M-initial lift of 2M | 1,159 | M3 | 123.4 ₹1,43,021 | 122.3 ₹1,41,746 Lowest |
| 1.02 | With intial lead of 10 m and additional lift of 2-3 m | 406 | M3 | 137.6 ₹55,866 | 136.3 ₹55,338 Lowest |
| 2.00 | Refilling with selected excavated earth other than M-Sand complying with relevant standard specifications for refilling in foundation and basement including spreading in layers not exceeding 15cm thick, watering and consolidation by hand ramming, etc., complete as directed by the departmental officers | 1,152 | m3 | 40.6 ₹46,771 Lowest | 47 ₹54,144 |
| 3.00 | Filling in foundation and basement with M-Sand in layers not exceeding 15 cms thick well watered rammed and consolidated complying with relevant standard specification including the cost of supplying river M-Sand etc., complete in all respects as directed by the departmental officers. | 68 | m3 | 1,764.7 ₹1,20,000 Lowest | 1,776 ₹1,20,768 |
| 4.00 | Filling in foundation and basement with Quarry dust in landyers not exceeding 15 cms thick well watered rammed and consolidated complying with relevant standard specification including the cost of supplying river M-Sand etc., complete in all respects as directed by the departmental officers. | 748 | m3 | 407.6 ₹3,04,885 Lowest | 410 ₹3,06,680 |
| 5.00 | Cement concrete 1:4:8 (one of cement, four of M-Sand and eight of hard broken stone) using 40mm size hard broken stone for foundation inclusive of shoring, strutting, bailing out water, ramming, curing, etc complete as directed by the departmental officers | 69 | m3 | 6,048 ₹4,17,312 Lowest | 6,064 ₹4,18,416 |
| 6.00Supply of Ready Mix Concrete M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kglms and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of M-Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including the cost of conveyance from plant to site,pumping,hire charges, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will b emade by the Department for the excess usage of materials). | |||||
| 6.01 | RMC | 732 | m3 | 8,058 ₹58,98,456 Lowest | 8,082 ₹59,16,024 |
| 7.00 | Providing form work for centering, shuttering etc., for all reinforced concrete work as plinth beam, raft beam, raft slab, grade beam etc., including shuttering, 3.00mm high using MS sheet of size 90cm x 60cm and BG 10, stiffened with MS angle of size 25mm x 25mm x 3mm laid over silver oak (Country wood) joists of size 10cm x 6.5 cm (Spaced about 91cm center to center) distance and supported by casurina props of size 10cm-13cm dia (spaced at 75 cm center to center) and removing the same after a specified period without damaging RCC works in all floors etc., complete as directed by the departmental officer..(Basement level) | 718.92 | m2 | 610.4 ₹4,38,829 | 604 ₹4,34,228 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
12 Aug 2025, 12:00 pmClosed
SE-East-II Circle
SE-East - II Circle
Construction of Mudhalvar Padaippagan G 1 stories at Perumbakkam scheme in chengalpattu district under Board Fund.
2025_TNUHB_587215_1
TNUHDB / 431 / HD / SE East-II / 2025
Open Tender
Civil Works
Item Rate
Perumbakkam
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹2.1 L
18 Aug 2025
30 Jul 2025
13 Aug 2025
4 Aug 2025
12 Aug 2025
4 Aug 2025
Amount
Open Earth work excavation for foundation with all leads and lifts in all soils and sub soils and to the required depth as may be directed except hard rock requiring blasting inclusive of shoring strutting and bailing out water wherever necessary refilliing the sides of foundation with excavated earth in layers of 15 cm thickness well consolidated depositing the surplus earth in places shown and levelling the site with all intial leads and lifts etc complete complying with relevant standard specification.
Initial lead of 10M-initial lift of 2M
With intial lead of 10 m and additional lift of 2-3 m
Filling in foundation and basement with M-Sand in layers not exceeding 15 cms thick well watered rammed and consolidated complying with relevant standard specification including the cost of supplying river M-Sand etc., complete in all respects as directed by the departmental officers.
Filling in foundation and basement with Quarry dust in landyers not exceeding 15 cms thick well watered rammed and consolidated complying with relevant standard specification including the cost of supplying river M-Sand etc., complete in all respects as directed by the departmental officers.
Cement concrete 1:4:8 (one of cement, four of M-Sand and eight of hard broken stone) using 40mm size hard broken stone for foundation inclusive of shoring, strutting, bailing out water, ramming, curing, etc complete as directed by the departmental officers
Supply of Ready Mix Concrete M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kglms and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of M-Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including the cost of conveyance from plant to site,pumping,hire charges, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will b emade by the Department for the excess usage of materials).
Providing form work for centering, shuttering etc., for all reinforced concrete work as plinth beam, raft beam, raft slab, grade beam etc., including shuttering, 3.00mm high using MS sheet of size 90cm x 60cm and BG 10, stiffened with MS angle of size 25mm x 25mm x 3mm laid over silver oak (Country wood) joists of size 10cm x 6.5 cm (Spaced about 91cm center to center) distance and supported by casurina props of size 10cm-13cm dia (spaced at 75 cm center to center) and removing the same after a specified period without damaging RCC works in all floors etc., complete as directed by the departmental officer..(Basement level)
Providing form work for centering, shuttering etc., for all reinforced concrete work as plinth beam, raft beam, raft slab, grade beam etc., including shuttering, 3.00mm high using MS sheet of size 90cm x 60cm and BG 10, stiffened with MS angle of size 25mm x 25mm x 3mm laid over silver oak (Country wood) joists of size 10cm x 6.5 cm (Spaced about 91cm center to center) distance and supported by casurina props of size 10cm-13cm dia (spaced at 75 cm center to center) and removing the same after a specified period without damaging RCC works in all floors etc., complete as directed by the departmental officer..
Providing form work for centering, shuttering etc., for all reinforced concrete work like Column, window boxing, Sun shade etc., including shuttering,upto 3.00mm high using MS sheet of size 90cm x 60cm and BG 10, stiffened with MS angle of size 25mm x 25mm x 3mm laid over silver oak (Country wood) joists of size 10cm x 6.5 cm (Spaced about 91cm center to center) distance and supported by casurina props of size 10cm-13cm dia (spaced at 75 cm center to center) and removing the same after a specified period without damaging RCC works in all floors etc., complete as directed by the departmental officer.
Fabricating and placing the following kinds of steel grills Fe 500 D grade steel reinforcement bars as per IS 786-1979 for all reinforced cement concrete works such as plinth beam, lintels, beams, sunshade, roof and floor slabs etc., including cost of steel and fabricating the reinforcement grills in position etc., complete in all floors (The rate to include the cost of binding wire steel also)
Brick work in cement mortar 1:5 (One of cement and five of M-Sand) using II class ground moulded chamber burnt bricks of size 9" x 4⅜" x 2¾" including proper setting, curing, etc., complete in all respects in Foundation and Basement
Masonry work using Autoclaved Aerated cement blocks of size 600 x200 200 mm in cement mortar 1:6 (one oc cement six of sand) for super structure in all floors including fixing frames of door and windows, proper setting curing etc., complete complying with standard specification as directed by the departmental officers.
Ground Floor
Frist Floor
Second Floor
Brick work in cement mortar 1:6 (One of cement and six of M sand) using Fly Ash bricks of size 23cm×11cm×7cm for super structure in the following floors including fixing the frames of doors and windows, scaffolding, proper setting curing etc, complete in all respects.
Ground Floor
Frist Floor
Second Floor
Masonry work using Autoclaved Aerated cement blocks of size 600 x200 x100 mm in cement mortar 1:5 (one oc cement six of sand) for super structure in all floors including fixing frames of door and windows, proper setting curing etc., complete complying with standard specification as directed by the departmental officers.
Ground Floor
Frist Floor
Plastering the walls with cement mortar 1:5,(One of cement and five of P-Sand) 12mm thick including providing band cornice curing etc., Complete in all respects as directed by the departmental officers.
Paving the floor with best quality Vitrified tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Flooring with ceramic tiles of approved quality, colour and design anti skid type joint free of size 305mm x 305mm x 6mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one of cement three of M-Sand) 20mm thick and laid straight alignment and pointed neatly with colour cement @ 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specification and as directed by the departmental officers.
Dadooing the walls with first quality colour glazed tiles of size 300mm x 450mm x 8mm of approved quality and make laid in cement mortar 1:2, 10mm thick and pointing with white cement neatly as directed by the departmental officers etc., all complete.
Supplying and fixing in position White / Colour Glazed Model Floor Mounted uropean Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting (SOR pg97)
Supplying and fixing in position White / Colour Glazed Model Floor Mounted uropean Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting (other than first floor )
Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including ecessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter
Suplying and fixing UPVC (Un - Plasticized Polyvinyl Chloride ) Windows of casement type (open) from the profile the size of outer frame 60mm x 58 mm and shutter profile are reinforcement with GI/ 1 mm 125 GSM and 100% corrosion free, the profiles are profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all edges of frame and shutter the shuttter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned .Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action ,security protective hinges ,strong locking systems and as per size for arresting noise and energy loss.The connecting mechanism netween sash and outer frame that enables opening of the window . The window should be fixed be fixed to the wall with 100% packing with screws and silicon packing all round the frames .The window should be got approved from the Executive Engineer before use on work. (pwd sr page.56, sl.no.191)
Providing and fixing iron grills for closing the opening using square rods as including one coat of red oxide primer cutting ,welding,labour for fixing etc complete (SOR Pg24 &36)
Supplying and fixing of 110mm dia UPVC SWR (Type A) rain water down fall pipe 4kg/cm2 confirming to IS 13590 with 1 No. of PVC bend/elbow and 1 No. of shoe with necessary clamps couplers gratings, teak wood plug etc. complete including fixing in proper position with solvent cement, making holes in the walls good of the dismantled portion with necessary brick work in CM etc. in all respects as directed by the departmental officers.
Supplying and fixing PVC Nahini trap / Floor Trap with PVC grating 100mmx75mm over the bed of brick jelly congrete and fixing in position etc., complte in all respect as directed by departmental officers.
Construction of inspection chamber of size 60cm × 60cm for 0.6m depth with Reinforced cement concrete wall of 15cm thick and base slab of 10cm thick of 1:2:4 proportion (One of cement, two of M-Sand and four of hard broken granite stones ) using 20mm gauge hard broken granite stones including the cost of steel and fabrication of reinforcement grills in position shutterring centering etc.,cement concrete 1:4:8 20mm HBSJ of 10cm thick for foundation including channeling benching etc., and top covered withextra heavy duty cover slab SFRC slab with frame 600mm(clear opening) including casting and fixing in position and necessary earth work excavation, refilling the sides of foundation in all soils except hard rock requiring blasting etc., complete in all respects
Painting the walls with 2 coats of plastic emulsion paint of approved quality with primer including cost of all materials, putty wherever required, brusheds and other alied T &P required for the work and using of existing scaffolding etc., complete as directed by the departmental officers.
Painting newly plastered wall surface with 2 coats of ready mixed exterior emulsion paint of approved quality have GLIMPSE of SPRING shade over a coat of priming of approved emulsion primer such as Asian (or) its equivalent brand including cost of all materials, putty wherever required, brusheds and other alied T &P required for the work and using of existing scaffolding etc., complete as directed by the departmental officers.
Finishing the Top of roof slab with levelling concrete P.C.C 1:2:4 (6-10mm Metal) average thickness of 40mm one course of approved quality of SOLAR Cool Tiles 305mm X 305mm X 7mm laid over the cement mortar bed of 20mm thick using cement mortar1:3 (one of cement and three of sand) mixed with water proofing compound 2% by weight of cement and pointing with the same mortar etc., complete in all respects as directed by the departmental officer.,
Wiring with 2x1.5sqmm PVC insulated single 1100V grade with ISI mark confirming to ISI 694/1990 in suitable PVC rigid pipe 1.8 mm thick with ISI mark on wall and ceiling with suitable size concelaed 16 gauge MS switch box covered by laminated hylem sheet 3mm thick for LIGHT POINT including the cost of cable, pvc pipe and specials ceiling rose, flush type 5ams SP mark switch PVC junction box 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, T.W.plugs, cement, labour and ciruit mains etc., complete for open wiring. (with ceiling rose)
Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick with ISI mark on wall and ceiling with suitable size concelaed 16 gauge MS switch box300mm x 200mm x 75mm covered by laminated hylem sheet 3mm thick for FAN POINT including the cost of cable, PVC pipes and specials, brass screws, ceiling rose, flush type 5ams SP mark switch PVC junction box 16gauge MS switch box covered by laminated hylem sheet 3mm thick, T.W.plugs, cement, labour and ciruit mains etc., complete for open wiring
Supply and run off 2 of 2.50 sq.mm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS:694/1990 with continuous earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed on walls and ceiling for mains including the cost of cable, PVC pipes and specials, cement, brass screws, TW plugs, saddles and labour etc., complete in all respects as directed by the departmental officers. PB to DB
Supplying and fixing of 5 A /15A 3 pin flush type wall socket with15A flush type switch concealed in suitable MS box in flush with wall andcovered with 3mm thick hylem sheet including cost ofwall socket, switch and labour charges fo wall cutting,grouting, flushing and making good, painting withprimary and finishing coat for MS box etc., complete asdirected by the departmental officers. (SD 138)
Earthing as per ISI Specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoat, common salt, G.I.reducer, checj nuts etc., and mansonry workand providing RCC cover slab 38mm thick for the Brick mansory including cost of steel and fabrication of reinforcement etc., complete in all respectes as directed by the departmental officers. (SD 233)
Supplying and fixing of 4 way single phase DB of 16amps/way with 16amps DP switch with metal glad of 500 volt(side handle) with Fuse and Neutral of suitable T.W. Board of size 40cm x30cmx6.3cm with earth connection etc., complete in all respects as directed by the departemental officers (SD 146)
Supplying and fixing in position best quality approved make white gazed earthenware wash hand basin of size 550 x 400mm with a pair of cast iron brackets, including cost of 15mm dia brass chromium plated pillar tap, 32mm dia C.P waste coupling, 32mm dia "B" G.I waste pipe, 15mm dia g.M wheel vale\ve, 15mm dia nylon connection 15mm dia brass nipples, 15mm c.P pillar tap etc.,
Supplying and fixing in position indian make white glazed earthen ware lipped mouth Porceline flat back urinal of best approved quality with GI pipe connection of sutable lenth 32mm bell mouthed PVC connestion, 15mm dia GM wheel valve, 15mm dia B Class GI waste atter pipe, 15mm Nyloc connection, 15mm dia brass nipple etc., fixng the urinal to the wall in position with necessary TW plugs, clamps, shellac etc., includin dismantling masonory if necessary and redoing the same to original condition fixing the 15mm dia GI pipe and whell valve. Checked with out any leakage complete complying with standard specification. (The urinal should be got approved by the Executive Engineer before use on work)
Supplying the following dia of UPVC pipes of approved quality at site of work as per table II specification of ISS 4985 / 1981 in standard length of 6 m each with one coupler at free of cost for every standard length of pipe. 10Kg / cm2.
40mm dia pipe sump to tank
32 mm dia pipe
20 mm dia pipe
Construction of circular RCC manhole of 1.2m internal dia with Reinforced cement concrete wall of 15cm thick and base slab of 15cm thick of 1:4:8 proportion (One of cement, four of sand and eight of hard broken granite stones ) using 40mm gauge hard broken granite stones including the cost of steel and fabrication of reinforcement grills in position shutterring centering etc., including channeling benching etc., and top covered withextra heavy duty cover slab SFRC slab with frame 600mm(clear opening) including casting and fixing in position and necessary earth work excavation, refilling the sides of foundation in all soils except hard rock requiring blasting etc., complete in all respects
Supplying and Laying SN8 Pipes including earthworks excavations for trenches in hard stiff clay, block cotton , hard red earth, shale, muram, gravel, stoney earth and earth mixed with small size boulder and hard gravely soil depositing earth on banks with initial lead of 10m and initial lift of 2m carting to site of work and lowering in to the trenches aligning, refilling the trenches with excaveted soil, watering, ramming to cosolidation etc,.
Supplying and fixing of 75 mm dia PVC soil pipe of 6kg / cm2 of approved quality confirming to ISI 13592/1992 with IsI monogram packing the joints with hempyarn and cement including fixing into dismantling and making good of the dismantled portion with necessary connection to the sanitary fittings painted with two coats of anti-corrisive paint including testing etc., complete in all respects.
Supplying of PVC pipe specials of approved quality suitable to pipe as per table II IS 14735/1999
110mm dia PVC vent Cowl
110 dia PVC bend/ elbow with door
110mm dia PVC single "Y" with door
110mm dia PVC elbow without door
75mm dia PVC bend elbow with door
75mm dia PVC singly Y with door
75mm dia PVC vent Cowl
75mm dia PVC elbow without door
Supplying and fixing of 110mm dia PVC Soil Pipe of 6 kg/Sq.cm. pressure confirming to IS 13592/1992 (Type B) of Finolex or equivalent with ISI Monogram of approved quality including packing the joints with rubber lubricant and fixing into the wall with specials including necessary Wooden Plugs, Screws, G.I Holding Down Clamps and chipping the walls wherever necessary and making good of the dismantled portion with brick work or cement mortar, necessary scaffolding including testing etc., complete in all respects as directed by the departmental officers.
Supplying and fixing of following dia PVC pipes fitting/specials as per IS 4985/1988 of approved quality inluding cost of pipes and labour charges for fixing etc., complete in all respects as directed by the departmental officers.
20mm dia coupler
20mm dia elbow
20mm dia tee
20mm dia end cap
20mm dia tap hevey type
Gun Metal Gate Valve (Heavy Duty)
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation.
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no of 10 passenger lift as per the following specifications including taxes and duties.(Gearless lift with machine room) 1.No of lift: 1 no. (Gearless) 2.Type of lift: stretcher Cum passenger lift 3.Capacity of lift: 10 persons /1020 kg conforming to 14665 (part 1) 2000 4.Speed: 1.5 M / Sec 5.Type of drive: V3F drive with enhanced ride comfort and near zero level functions 6. No of floors: G+1 Floor 7.Total travel: 3.0 mts x 7 Landing = 21 mts 8.Leveling accuracy: high level accuracy with smooth and jerk free stopping 9.Construction of CAR: No. 4 hardened sheet high quality stainless steel car and hand rail granite flooring and Perspex false ceiling. 10. Position of machine: directly above the lift well. 11.No of landing service: One in the front side- 1 no. 12.No. of car entrance: one in the front side only 13.Car entrance door: power operated automatic V3F drive center opening sliding SS door 14.Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings. 15.Lift well :As per structural design conforming to IS 14665(part1) 2000 to be constructed by the Building contractor 16.Lift pit depth: conforming to 14665 (part 1)2000
17.Car inner size, Total weight of person and Overhead height : conforming to 14665 (part 1)2000 18.Car clear opening: 900 mm wide x 2000 mm height as per IS 14665 (part 1)2000 19.Lift machine room size: as per ISI 14665 (part 1) 2000 to be constructed by the building contractor 20. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light 21.Control: micro computer (micro processor):based simplex collective control with / without attendant 22.Car fittings: CFL lighting with 1 no 300 mm sweep cabin fan. 23.Lift well: RCC construction with brick masonry to be constructed by the building contractor 24.Induction: UP / DOWN digital direction and floor position indicator for all landings in all floors and inside the car. 25.Emergency alarm bell: battery operated bell to be provided with automatic charging device 26.Emergency light: battery operated light to be provided with automatic charging device 27.Fire mans switch: to be provided at the GF 28.Minor builder works: to be provided by the lift contractor.(S&F of bulk head, 5A switch, light point, wiring 2 of 2.5 sqmm at every floor and machine room lighting, 4way/8way/12 way TPN DB) and other requirements. 29.Scaffoldings: to be provided by the lift contractor. 30.Sill angles and facia plates: SS to be provided by the lift contractor. 31.Steel for lift machinery: to be provided by the lift contractor.
32. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor. 33.Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories and single phase preventor specifying to IS norms 34.Provision for intercom with phone: to be provided by the lift contractor. 35.Lift license: preparation of drawings payment of charges to CEIG and insurance policy for both lift & body if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor 36.Floor position announcer: to be provided by the lift contractor. 37.Special features 38.a) Infra red door sensor with full height screen b) Full width half height rear panel mirror c)Tubular SS hand rail in car d) Stainless steel signal features e) Vandal proof SS button with SS cover f) SS door frames for landing doors g) V3F door operator h) Call register signal i) Stainless steel facia plates for car operating panel and landing fixtures j) Steel ladder for lift machine room k) On / off switch for fan and light l) Over load warning indicator with audio announcer m)Voltage stabilizer for control circuits
n)Braille button o) Precautionary measures etched in SS plate 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries 40. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year 43.All the features as per differently abled person Act should be provided. 44.2 hrs.fire retardent landing doors
Passenger Lift 10 person capacity
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers. (TN PWD SR 2024-25 M0827)
Supply and fixing 4 core, 10 sqmm cable of PVC Insulated and sheathed flate type copper cable confirming to IS 694/1990.
Supply and run of 25mm x 6mm GIFl at Down Condutor with necessary clamps/ supports on wall / floor /ground for earth connection
Added GST @ 18%
Namakkal Constructions (BID ID -1426133)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .