Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | ₹12.7 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹14.6 LRejected-AOC | ₹14.6 L | L2 | Rejected-AOC L2 Rejected |
| 3 | L3₹14.6 LRejected-AOC H NO 5 117 BODUPPAL INDIRA NAGAR COLONY GHATKESAR MANDAL R R DIST 500 092 | MEDCHAL MALKAJGIRI | TELANGANA | 500092 | ₹14.6 L | L3 | Rejected-AOC L3 Rejected |
| 4 | L4₹17.2 LRejected-AOC PRAGATHI PRIDE APARTMENT 3 4 520 FLAT NO 203 BARKATPURA HYDERABAD 500 027 | HYDERABAD | TELANGANA | 500027 | ₹17.2 L | L4 | Rejected-AOC L4 Rejected |
| Sl No | Description | Qty | Unit | vaibhav & Co L2 | CHARAN ELECTRICALS L4 | Shri Lakshmi Narashima Enterprises L3 | SRI SAI BABA CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Providing 'B' Check of the DG Sets upto the time of 300 hrs/6 months whichever is earlier with the activity like changing of fuel filter, lube oil filter, air filter, separator, fuel water, premix coolant engine oil, corrosion inhibitor by the authorized service agency of the manufacturer and testing there as directed by Engineer-in-Charge Note:- i) Cost of clearning/lubricating materials item like gasket, washer, bolt, nuts etc., are deemed to be included in quoted rate. ii) Cost of spares if any needs to be replaced for efficient functioning of equipment will be measured and paid separately as per OEM price list and tax invoice of OEM/Authorised service. iii) Cost of fixing and commissioning of spares is deemed to be included in the quoted rate. iv) Inspection report of installation or servicing/repair and tax invoice of the OEM/ Authorised service agencies for the spares used to be submitted for release of payment | |||||||
| 1.10 | 50 KVA | 1 | No | 25,000 ₹25,000 | 24,200 ₹24,200 | 24,400 ₹24,400 | 12,000 ₹12,000 |
| 1.20 | 62.5 KVA | 1 | No | 25,000 ₹25,000 | 31,000 ₹31,000 | 31,000 ₹31,000 | 12,000 ₹12,000 |
| 1.30 | 300 KVA | 1 | No | 65,000 ₹65,000 | 53,000 ₹53,000 | 53,100 ₹53,100 | 32,000 ₹32,000 |
| 1.40 | 500 KVA | 1 | No | 75,000 ₹75,000 | 68,000 ₹68,000 | 68,000 ₹68,000 | 50,000 ₹50,000 |
| 1.50 | 750 KVA | 4 | No | 80,000 ₹3.2 L | 1,60,000 ₹6.4 L | 1,45,000 ₹5.8 L | 95,000 ₹3.8 L |
| 2.00 | Calibration of HT VCB's, 11 KV of any rating including maintenance and complete servicing of VCB's de-assembling of operating mechanism, parts, well cleaning with petrol CRC 226, replacing of the unserviceable parts and accessories like spring, gasket, coils, nuts, bolts and washers etc., oiling and gresing to the moving parts, re-assembling, setting of mechanism, cleaning, de-carbonizing of arc control pot, fixed and moving contact, testing, trip check of various faults, cleaning of the complete panel, busbar system, CTs metal parts by authorised service agency/OEM all as directed by Engineer in Charge. The aency shall be approved by department. | 12 | Nos | 3,500 ₹42,000 | 5,300 ₹63,600 | 5,500 ₹66,000 | 21,000 ₹2.5 L |
| 3.00 | All as per Item No. 2 above but 66 KV SF 6 breakers | 3 | Nos | 8,500 ₹25,500 | 11,000 ₹33,000 | 10,000 ₹30,000 | 17,000 ₹51,000 |
| 4.00 | Overhauling/repairs of LT ACBs of any rating, removing circuit breaker from cubicle, dust out and clean the circuit breaker, tighten all nuts and bolts of busbar for looseness, check main isolating contacts of the breaker and the corresponding cradle contact for drawout breaker and clean with CRC, clean insulating surface of Arc chutes, check CT connections check earth connections, check and tighten control wires, greasing of the internal mechanism release testing with test kit, replacing of any components found defective, adjust setting of contact gaps, trip drop assemgly, closing Arcing setting, adjusting alignment of LV disconnects, fixed and moving contacts, tesing release tripping, long time short time, earth fault etc., all as directed by Engineer-in-Charge. | 29 | Nos | 950 ₹27,550 | 5,000 ₹1.4 L | 5,500 ₹1.6 L | 6,500 ₹1.9 L |
| 5.00 | Testing of oil, dehydration and filtration of step down 11 Kv 415 V transformer oil/servo 3 phase voltage stabilisers for various capacity of transformers of the following on running conditions of transformer and dieelectric strength not less than 60 Kv in 2.5 mm gap (RMS) complete all as specified including topping up of new transformer oil as required.
Note:
i) Dehydration and filtration shall be carried out by licenced agency at Site by bringing filtration plant. The agency shall be approved by department.
ii) Testing of oil shall be carried out before filtration and after filtration of insulating oil.
iii) topping up of new transformer oil will be measured and paid seperately at relevant item. | 9,000 | Ltrs | 95 ₹8.6 L | 40 ₹3.6 L | 24 ₹2.2 L | 15 ₹1.4 L |
Tender Value
₹14.2 L
EMD Value
₹28,380
Closing Date
26 Mar 2026, 2:00 pmClosed
Dr Rakesh Sahu
Estate Management Unit DRDO Township, C V Raman Nagar, Bangalore-93
Maintenance of DG Sets of 50 KVA, 62.5 KVA, 300 KVA, 500 KVA, 750 KVA and 1500 KVA, HT 11 KV, VCBs, LT ACBs and Transformer Oil Filtration at K Site, Site I, Site II, Oo PMO, DG (ECS) and MTRDC
2026_DRDO_902288_1
EMU/BAN/DG SETS/MTRDC/2025-26
Open Tender
Miscellaneous Works
150 days
Bangalore
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹28,380
6 May 2026
12 Mar 2026
27 Mar 2026
12 Mar 2026
26 Mar 2026
12 Mar 2026
Calibration of HT VCB's, 11 KV of any rating including maintenance and complete servicing of VCB's de-assembling of operating mechanism, parts, well cleaning with petrol CRC 226, replacing of the unserviceable parts and accessories like spring, gasket, coils, nuts, bolts and washers etc., oiling and gresing to the moving parts, re-assembling, setting of mechanism, cleaning, de-carbonizing of arc control pot, fixed and moving contact, testing, trip check of various faults, cleaning of the complete panel, busbar system, CTs metal parts by authorised service agency/OEM all as directed by Engineer in Charge. The aency shall be approved by department.
All as per Item No. 2 above but 66 KV SF 6 breakers
Overhauling/repairs of LT ACBs of any rating, removing circuit breaker from cubicle, dust out and clean the circuit breaker, tighten all nuts and bolts of busbar for looseness, check main isolating contacts of the breaker and the corresponding cradle contact for drawout breaker and clean with CRC, clean insulating surface of Arc chutes, check CT connections check earth connections, check and tighten control wires, greasing of the internal mechanism release testing with test kit, replacing of any components found defective, adjust setting of contact gaps, trip drop assemgly, closing Arcing setting, adjusting alignment of LV disconnects, fixed and moving contacts, tesing release tripping, long time short time, earth fault etc., all as directed by Engineer-in-Charge.
Testing of oil, dehydration and filtration of step down 11 Kv 415 V transformer oil/servo 3 phase voltage stabilisers for various capacity of transformers of the following on running conditions of transformer and dieelectric strength not less than 60 Kv in 2.5 mm gap (RMS) complete all as specified including topping up of new transformer oil as required. Note: i) Dehydration and filtration shall be carried out by licenced agency at Site by bringing filtration plant. The agency shall be approved by department. ii) Testing of oil shall be carried out before filtration and after filtration of insulating oil. iii) topping up of new transformer oil will be measured and paid seperately at relevant item.
Transformer 2000 KVA - 3 Nos
Transformer 1600 KVA - 1 No
Transformer 1250 KVA - 2 Nos
Transformer 750 KVA - 2 Nos
Transformer 500 KVA - 2 Nos
Transformer 250 KVA - 2 Nos
Transformer 315 KVA - 1 No
Transformer 200 KVA - 1 No
Transformer 100 KVA - 1 No
Supply of transformer oil in sealed drums having dielectric strength 60 KV in 2.5mm gap (RMS)
SCHEDULE OF CREDIT
Old unserviceable items obtained from 'B' Check and 'D' Check including old oil
Old unserviceable damaged transformer oil, VCB/ACB parts
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Tenderenquiry08.pdf
Tender Documents • 0.24 MB
BOQ_948384.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid