| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC Lowest tender | |
| 2 | L2₹23.6 L+₹2.9 L (13.9%)Rejected-Finance | L2 | Rejected-Finance Not Being lowest tender | |
| 3 | L3₹24.1 L+₹3.4 L (16.3%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L3 | Rejected-Finance Not Being lowest tender | |
| 4 | L4₹24.4 L+₹3.7 L (17.9%)Rejected-Finance HOUSE NO 03 RAGHAVPURAM MALL ROAD MORAR GWALIOR | GWALIOR | GWALIOR | MADHYA PRADESH | L4 | Rejected-Finance Not Being lowest tender | |
| 5 | L5₹25.4 L+₹4.7 L (22.6%)Rejected-Finance | L5 | Rejected-Finance Not Being lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
17 Dec 2021, 6:00 pmClosed
GE AF TA
GE AF TA GWALIOR-474020
REPAIR/MAINT OF INTERNAL ELECTRIC FITTING AND FIXTURES IN EAST WING OF RUNWAY OF TECH AREA AT AF STN GWALIOR
2021_MES_490596_1
8900/1331/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) TA Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TA GWALIOR
₹40,000
Yes
11 Jan 2022
26 Nov 2021
27 Dec 2021
26 Nov 2021
17 Dec 2021
10 Dec 2021
Amount
Supplying & fixing in repair Stout plus LED is a complete range of industrial LED batten to replace traditional T8 batten.The range is perfact for lighting large areas such as corridor, warehouses & genral purpose spaces 40watt including all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 1.5 sqmm cable with all accessories and fixing arrangement for fixing the light fitting to walls / roof surface complete all as specified and directed. Make :- Havells Cat No STOUTPLUS1200BS40WLED857SPCWH/BAJAJ CAT PART NO BLTRU 40W NW VIVA and equivalent in makes as per Appendix 'A' to PS.
M & L for checking & repairing watch tower lights at an approx height of 15 m and other connected works for making the tower lights serviceable as directed by JE/Engr-in-Charge/men on complaint cell by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light almost 100% serviceable complete all including all safety measures/precaution, as specified and directed. NOTES :- (i) Rate quoted shall deemed to be included for required minor material like insulation tap/repairing of junction box with lugs etc. (ii) Items like Driver, Igantor, bulbs/light source other items other than mentioned above wil be paid separately under the relevant items of the BOQ/Sch 'A'.
Supply, fixing, installation, commissioning and testing in replacement aviation obstruction lights ( on and over hangers / high rise buildings) comprising of integral LED aviation light comprising of die-cast aluminium alloy housing , with polycarbonate enclosure and including lamp and necessary connection with electric source with copper conductor 23/0.0076 flexible twisted three core cable complete all as specified and directed Make :- Bajaj Cat part No. BGAV 302 LED or equivalent in make as per Appendix 'A' to PS
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 48 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :-Havells cat part No ENDURAPEARLNEOSL48WLED757PASYTOPC or equivalent in make as per Appendix 'A' to PS.
S&F in repair Ultra bright glass 18W LED tube light with driver and high efficiency suited for installation in exsiting T5 fitting with G5 lamp holders complete all as specified and directed. Make :-Havells Cat part No -TITANISLEEK1149T5DSTL18WLED865SPC or equivalent in make as per Appendix A' to PS.
S&F in repair porcelain lamp holder threaded type suitable for HPMV/ HPSV lamps of any capacity complete all as specified and directed. Make - Bajaj/ CG/ philips
S&F in repair open construction HPMV Ballast copper wound of following capacity suitable for HPMV fittingcomplete all as specified and directed:- (a) 400 watt Make :- Bajaj Cat part no - BJOR 400 MV or equivalent model of makes as approved by GE.
(b) 250 watt Make :- Bajaj Cat part no - BJOR 250 MV or equivalent model of makes as approved by GE.
S&F in repair open construction HPSV/MH Ballast copper wound suitable for respective wattage given below for HPSV/MH fitting complete all as specified and directed :- (a) 400 watt Make :- Bajaj Cat part no - BJOS 400 SV/MH or equivalent model of makes as approved by GE.
(b) 250 watt Make :- Bajaj Cat part no - BJOS 250 SV/MH or equivalent model of makes as approved by GE.
(c) 150 watt Make :- Bajaj Cat part no - BJOS 150 SV/MH or equivalent model of makes as approved by GE.
(d) 70 watt Make :- Bajaj Cat part no - BJOS 70 SV/MH or equivalent model of makes as approved by GE.
S&F in repair Igniter suitable for HPSV/ MH lamp fitting of capacity 70/ 150/ 250/400 watt complete all as specified and directed. Make :- Bajaj Cat part no - BJIGN HPSV / MH-1 or equivalent model of makes as approved by GE.
S&F in repair condenser 20 mfd suitable for HPSV/ MH lamp fitting complete all as specified and directed.
S&F in repair HPMV lamp elliptical shaped outer shell of following capacity suitable for HPMV lamp fitting complete all as specified and directed (a) 400 watt
(b) 250 watt
S&F in repair MH lamp, tubular shaped outer shell of following capacity suitable for MH lamps fittings complete all as specified and directed:- (a) 400 watt
(b) 250 watt
S&F in repair MH lamp, double ended of capacity suitable for MH lamps fittings complete all as specified and directed:- (a) 150 watt
(b) 70 watt
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm bore GI pipe medium grade for earth lead protection pipe of suitable length and GI pipe 20 mm bore medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its Watering/protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.
Supplying & fixing earth continuity conductor or main earthing lead fixed to walls or to poles or any other indicated situation for loop earthing with using 4mm dia GI earth wire complete all as specified and directed
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 6 sqmm 2 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed.
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 10 sqmm 2 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed.
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 16 sqmm 4 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed.
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 25 sqmm 3.5 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed.
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 95 sqmm 3.5 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed.
Supply and fixing / laying pipe, GI light grade 40 mm bore fixed on walls or laid under floor with all accessories complete all as specified & directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and spreading clean, dry, fine river sand for UG electric cable in two layers (8 cm thick before laying the cable & 15 cm thick after laying cable) total 23 cm thick including gentle punning the sand upto 18 cm (total thickness) and consolidated around cable for protection of under ground cable complete all as specified and directed. (Note :- Only punned thickness shall be measured for payment).
Supply & Laying precast PCC cable concrete cable cover LV low voltage type -I flat ISI marked of size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-charge. Make :- Mahatab/Ravi tiles/Duracoat
Supply and fixing in repair LED driver 240 V 50 Hz suitable for the existing LED flame proof lights fittings for the following watt :-
(a) 75-90 Watt
(b) 120-180 watt
Supply and fixing in repair Surge protector 10KV/5KA suitable for LED light driver of make Havell/Bajaj/Philips/CG/Wipro/C&S or as per existing make complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair 15 Watt LED cylindro track light size 70mm dia, 180mm legth, 212mm height and high power LED as light source with lumens intensity level 3500 lumens alternate to the conventional HID lamps with complete accessories complete all as specified and directed by Engr-in-charge. Make :- Havells CAT Part No CYLINDROTS15WLED857S3WIRE38DGRY or equivalent make as approved by GE.
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc all as directed.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick hylam laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed at site for the following :
(a) One light/ Fan point controlled by one way switch.
(b ) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No-31.00 here in before but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :-
(a) One light/ Fan point controlled by one way switch.
(b ) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No-33.00 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
S&F switch piano flush type single pole one way 5 Amps 230 V.
S&F switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose,
All as per item No 36.00 here-in-before above but 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) .
S&F socket out let 3 pin, 5 Amps, 230 Volt multipurpose flush piano type. .
S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in repairs lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge
S&F in repairs moduler switch socket 6 Amps -2/3 pin combined 2 module, complete all aspsecified and directed.
S&F in repairs Modular Switch socket 6/ 16 Amps 2/3 Pin combined 2 module complete all as specified and directed.
S&F in repairs modular switch piano flush type single pole one way 6 Amps,1 module complete all as specifed and directed.
S&F in repairs modular fan regulator Step type 120W 2module complete all as specified and directed.
Supplying, fixing in repair & testing decorative recess mounting 36 watt LED full out put luminaries suitable for Armstrong ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed. Make :Havells Cat Part No -VENUSNE02X2PLR18-48WLED830MOD Racess mounted 2x2 LED or equivalent in make as approved by GE.
S&F in replacement 8 Watt LED bollard light one meter long with Opel acrylic diffuser and IP-65 protection including necessary concreat work complete all as specified and directed Make :- Havells Cat Part No BAMBOOBLS8WLED830PSYMTOPC or equivalent in make as approved by GE.
Supply and fixing GI 1.2 mm thick perforated cable tray of size 100mmX250MM for giving support/hide and to route electricals cables, communication cable etc to the different parts of building complete all as specified and direced.
m/s anil traders
anand enterprises
M/s. Ravi and brothers
UNIVERSAL AGENCY
M/S SANTOSH CONSTRUCTION CO
M/S Rakesh Verma
lodhi builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .