Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹32.0 L+₹24,730 (0.78%)Rejected-AOC | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹32.4 L+₹72,465 (2.28%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹36.7 L+₹5.0 L (15.7%)Rejected-AOC 0 0 MOH SITARGANJ PIPRI POST UKHLI KATRA SHAHJAHANPUR UTTAR PRADESH 242301 SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242301 | SHAHJAHANPUR | UTTAR PRADESH | 242301 | L4 | Rejected-AOC Not lowest | |
| 5 | L5₹38.0 L+₹6.3 L (19.8%)Rejected-AOC 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | L5 | Rejected-AOC Not lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
13 Oct 2020, 6:00 pmClosed
GE Bharatpur
GE Bharatpur
REPAIR/ REPLACEMENT TO SECURITY FENCING, BOUNDARY WALL, TRAVERSE, CULVERT, SWT, DRAIN AND OTHER MISC ITEMS AT 39 FAD BHARATPUR
2020_MES_378400_1
8977/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE Bharatpur
Class D category a(I)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹70,000
Yes
19 Oct 2020
17 Sept 2020
15 Oct 2020
17 Sept 2020
13 Oct 2020
30 Sept 2020
Amount
M&L for Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from concrete or brick work and making good disturbed ground complete all as specified and as directed by Engineer in Charge
M&L Dismantling fencing wire mesh, any type complete all as specified and as directed by Engineer in Charge
M&L Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed by Engineer in Charge
M&L Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and as directed by Engineer in Charge
M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc complete all as specified and as directed by Engineer in Charge
Ditto all as per Srl Item No 05 above but fixing only complete all as specified and as directed by Engineer in Charge
M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long but n exc 10cm long complete all as specified and as directed by Engineer in Charge
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed by Engineer in Charge
Supply only Chain link MS galvaised fencing, any size or type complete all as specified and as directed by Engineer in Charge
M&L Mild steel bars 6 to 8mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and as directed by Engineer in Charge
M&L Plain mild steel wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified and as directed by Engineer in Charge
M&L Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) fixed in repair complete all as specified and as directed by Engineer in Charge
Ditto all as per Srl Item No 13 above but except material complete all as specified and as directed by Engineer in Charge
M&L Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above GL) complete all as specified and as directed by Engineer-in-Charge
M&L Dismantling of brickwork or stone boulder masonry in portions built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer-in-Charge.
M&L Demolition of of stone /boulder masonary , built in lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed by Engineer in Charge
M & L for PCC (1:3:6) type C-2 using 40 mm graded stone agg in fdn filling and mass concrete complete all as specified and as directed by Engineer in Charge
M&L Removing cement mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and as directed by Engineer in Charge
M&L Removing mortar from and cleaning stones obtaned from masonary built in cement mortar of any description (excluding ashlar masonary) and stone set pavings stacing for measurement incl all extra handling and removal and desposing off rubbish complete all as specified and as directed by Engineer in Charge
M&L Walling of random rubble, brought upto course well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed by Engineer in Charge
Ditto all as per Srl item No 20 above but except stone complete all as specified and as directed by Engineer in Charge
M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed by Engineer in Charge
Ditto all as per Srl Item No 22 above all as specified and as directed by Engineer in Charge
M&L Rough Cast Plaster, under coat 10 mm thick of CM (1:3) and plastic state the Rough cast mixture of crushed stone aggregate 6 to 12 mm mixed with coarse sand and cement ratio f 1:1:1 shall be applied and finished even complete all as specified and as directed by Engineer in Charge
M&L for preparation of newly plastered surface and applying two coats of cement base paint of approved shade on walls complete all as specified and as directed by Engineer in Charge
Complete removal of existing treatment on old wall surface, preparing plastered or unplastered surface, applying two coats of cement base paint complete all as specified and as directed by Engineer in Charge
M&L for providing cement concrete (1:2:4), type B-1 using 20mm graded stone aggregate as in lintels upto 1.50m clear span, cills steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parpets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering , slightly rounded or chamfered angles and throating including necessary form works etc complete all as specified and as directed by Engineer in Charge
M&L for Cutting out decayed brick work of one brick thick and refacing with new bricks in Cement mortar 1:6 (1 course of header to 3 courses of strechers) and making good complete all as specified and as directed by Engineer in Charge
M&L for broken glass coping on top of walls in cement mortar 1:3 complete all as specified and as directed by Engineer in Charge
Supply only 50 mm HDPE pipe of pressure rating not less than 6 Kgf per squre cm to walls complete all as specified and as directed by Engineer in Charge.
Supply only integral waterproofing compound complete all as specified and as directed by Engineer in Charge
M&L Dismantling of reinforced concrete drain pipes any dia, jointed in cement mortar and taking out of trenches complete all as specified and as directed by Engineer in Charge
M&L Reinforced concrete pipes 300 dia , class NP3, laid and jointed complete with collars complete all as specified and as directed by Engineer in Charge
M&L Reinforced concrete pipes 450 dia , class NP3, laid and jointed complete with collars complete all as specified and as directed by Engineer in Charge
M&L Cutting openings through walls built in cement mortors for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises complete all as specified and as directed by Engineer in Charge
M&L Pre-cast cement concrete Type B1 1:2:4 (20 mm graded aggregate block masonry with solid blocks, exc. 10 cm in width and setting in Set in cement mortar 1:4, complete all as specified and as directed by Engineer in Charge
M&L for two coats of synthetic enamel paint on steel surfaces exc 10 cm width or girth over one coat of red oxide primer after preparing old painted surfaces by scrapping and rubbing with sand paper complete all as specified and as directed by Engineer in Charge
M&L for two coats of synthetic enamel paint on steel surfaces exc 10 cm width or girth over one coat of red oxide primer after preparing new and untreated surfaces by scrapping and rubbing with sand paper complete all as specified and as directed by Engineer in Charge
M&L for de-watering the SWTs including removing the moss, silt, debries etc complete all as specified and as directed by Engineer in Charge
Surface preparation: Clean the surface thoroughly to make it free from dirt, dust, etc. and remove loose damaged concrete from the surface complete all as specified and as directed by Engineer in Charge
Providing skim coat to maintain profile of structural members by using latex B2 modified air cured mortar system prior to fibre wrapping (1 cement: 3 part graded cleaned prepacked river sand 5 to 10% latex mortar by weight of cement 0.5 w/o ratio.) upto 10 mm thickness including levelling, profiling, etc. complete all as specified and as directed by Engineer in Charge
Nozzles teflon : Providing and fixing teflon nozzles at 350 mm c/c upto 100 mm depth from chipped surface including drilling holes, inserting and fixing nozzles and cutting off nozzles after grouting is complete all as specified and as directed by Engineer in Charge
Grouting: Providing and injecting high molecular weight low viscoous grout Monopol of Krishna Conchem or equivalent into concrete at required pressure (minimum 3 kg/cm2) complete all as specified and as directed by Engineer in Charge
Waterproofing Treatment : Carrying out waterproofing treatment on underground water tank as per standard practice & details given below ensuring safety in all respect. Supply & application of two coats of SG EC/UV two compound cementatious coating on entire prepared surface (consumption will be 1.5 to 2 kg/m²) using soft bristle brushes & rollers and as per OEM recommendations, carrying out suitable treatment for all existing adjoining structures as per standard practice (as mentioned in SLA), carrying out all related works without any damage to the existing installations etc. complete as per site requirement & to the satisfaction of Engineer-in-charge.
M&L for rendring 15mm thick in two layers, 5mm thick in CM (1:4), over 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces mixed with liquid water proofing compound as per manufacturers instruction finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge. (WPC to be measured and paid for separately)
S&F Wire netting of galvanised steel wire 1.40mm dia and size of mesh12mm fixed with tinned tacks or wire staples complete all as specified and as directed by Engineer in Charge
Taking down cement or cement lime plaster of any description on brick or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer in Charge
M&L for rendring 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces mixed with liquid water proofing compound as per manufacturers instruction finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge. (WPC to be measured and paid for separately)
Supply only liquid water proofing compound complete all as specified and as directed by Engineer in Charge
M & L for providing PCC type B 0 (1:2:4) using 12.5 mm graded aggregateas in lintle upto 1.5 M clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer in Charge
Removing building materials etc.(other than spoil payeable in earth work) to a distance nexc 5 Km (outside Deopt perimeter), including loading, unloading and stacking at the destination complete all as specified and as directed by Engineer in Charge
M/s Ranaji Construction Co
PD GUPTA AND COMPANY
M/s Gupta Traders
deva engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .