Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.9 CrAdmitted-Finance | -2.10% | ₹2.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.0 CrAdmitted-Finance | +1.00% | ₹3.0 Cr | L2 | Admitted-Finance |
Updated dates
Tender Value
₹3.0 Cr
EMD Value
₹5.9 L
Closing Date
23 Jan 2026, 3:00 pmClosed
Executive Engineer
Office of Executive Engineer UPAVP CD GKP-02 , Basti
CONSTRUCTION OF REMAINING WORK OF COMMUNITY HEALTH CENTER LOTAN, DISTT- SIDDHARTH NAGAR.
2026_UPHDB_1103483_1
1560/F-05/25 Date- 29.12.2025
Open Tender
Civil Works - Buildings
365 days
Siddharth Nagar (Lotan)
As per Technical Bd
3 documents required · 3 mandatory
₹5,310
Executive Enginner UPAVP CD GKP-02, Basti
₹5.9 L
3 Feb 2026
2 Jan 2026
24 Jan 2026
2 Jan 2026
23 Jan 2026
2 Jan 2026
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
Cartage of good earth for filling up to 5.00 Km. distance including loading unloading and drasing, raming watering proper with 20 cm layer watering proper with 20 cm layer not exceeding work executed as per direction E/I complete.
Supplying and filling of sand in plinth/ under floors including watering ,ramming, consolidating, dressing complete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering all work up to plinth level 1:2:4 (1 cement :2coarse sand :4 graded stone aggregate 20 mm nominal size derived from natural sources)
Construction of drain along with apron 230x150mm including excavation base concrete 1:4:8 in thickness of 7.5 cm of and brick work in foundation 1:4(1 cement : 4 coarse sand )and brick work in half brick thick in foundation 25 mm thick cement concrete (1:2:4 mix) flooring base and 20 mm thick plaster (1:2) finished with neat cement
diluting and enjecting chemical emulsion for post constructional anti termites treatment (excluding cost of cemical emulsion) with chlorpyriphos/lindane E.C 20% with 1% concentration
R.C.C. work with cement approved coarse sand and 20mm. Gauge approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows, excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including s/o all materials required for proper completion of the work. Ground floor
Same as item no. 8 but reinforced cementconcrete work in lintels & sun shadein 1:1.5:3 on first floors.
Same as item no. 8 but reinforced cementconcrete work in lintels & sun shadein 1:1.5:3 on Second floors.
R.C.C. work with cement approved coarse sand and 20mm. Gauge approved stone grit in the proportion of 1:1.5:3 in slab, excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including s/o all materials required for proper completion of the work. Ground floor
Same as item no.11 but for first floor in slab.(Using 1:1.5:3 Mix concrete)
Same as item no.11 but for Second floor in slab.(Using 1:1.5:3 Mix concrete)
R.C.C. work with cement approved coarse sand and 20mm. Gauge approved stone grit in the proportion of 1:1.5:3 in beam, excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including s/o all materials required for proper completion of the work. Ground floor
Same as item no.14 but for R.C.C. beams on first floor. (Using 1:1.5:3 Mixconcrete)
Same as item no.14 but for R.C.C. beams on Second floor. (Using 1:1.5:3 Mixconcrete)
R.C.C. work in thin shelves as above initem 5 ( about 2.5cm thick ) includingbending, binding and fixing of shelves in positions as per design making good the walland repairing the edges of shelve to the satisfaction of the Engineer-in-charge,including cost of all materialscentering and shuttering etc. butexcluding cost of reinforcement. NS1
Providing precast cement concrete Jali 1:2:4 (1 cement :2 coarse sand (zone-III): 4 graded stone aggregate 6 mm nominal size),reinforce with 1.6 mm dia mild steel wire,including centering and shuttering, roughening cleaning,fixing and finishing in cement mortar 1:3 (1cement :3 fine sand ) etc. complete excluding plastering of the jamb sills and soffits.40 mm thick
Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap)
Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 300 mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.1.Initial test (Test Load 2.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge 2.Routine test (Test Load 1.5 times the Safe capacity)
Brick work with bricks of class designation 15 (Class-150) in foundation and plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand (FM 1.50 to 2.00))
Same As above but in super structure in 1:6 proportion including necessary cutting and moulding of bricks as required and also including honey comb, brick work thickness of wall not to be less then one brick thick add for extra labour . Ground Floor
Same As above but in super structure in 1:6 proportion including necessary cutting and moulding of bricks as required and also including honey comb, brick work thickness of wall not to be less then one brick thick add for extra labour . Ground Floor
brick work in F/p in 1:4
Same as item no 24 but for second Floor
Half brick masonry with bricks of class designation 15 (Class-150) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand (FM 1.50 to 2.00)) (GF+FF+SF)
Providing and laying damp proof coarse 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand :4 graded stone aggregates 10 mm nominal size) and curing complete.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
P&L Brick coba 12mm thick laid with M-150 class brick bats coba7.50cm thick gap of 15mm to each other,over 20mm thick base of cement mortar 1:4 cement & coarse sand mixed with water proofing compund spreading cement slurry mixed with aerelic cement concrete water proofing compund filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement & coarse sand mortar finished smooth & top mashed false square 30cm x30cm and side wall parapet shall be mono tythic plaster wall upto 30cm.higher and junction and corner shall be rounded by brick ballast cement & coarse sand masonary Coba with top finished plaster mixed with acetic water proofing compund @ 2% by weight & including S/O all material labour T&P etc complete for proper completion of work.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
steel work welded in built up section/ framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer using structural steel etc as required .in grating,frames , guard bar, ladder railing ,brackets , gates and similar works (M.S. Work in D/W Hold fast)
steel work welded in built up section/ framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer using structural steel etc as required .in grating,frames , guard bar, ladder railing ,brackets , gates and similar works (M.S Grill)
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) (MS Tubular section for window)
steel work welded in built up section/ framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer using structural steel etc as required .in grating,frames , guard bar, ladder railing ,brackets , gates and similar works (M.S. Steel Railling)
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (M.S. Tubular section door chaukhuts)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire average width of aperature 1.4 mm in both directions with wire of dia 0.63 mm all complete. 9.51.2 with 12 mm mild steel U beadig.
Mild Steel or iron in plain work such asReinforced concrete or reinforced brick work( when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorized overlapping shall be measured (GF+FF+SF)
Fixing of Door chaukhats in position.
Fixing of windows chaukhats in position.
Fixing of ventilators chaukhats in position.
15 mm plinth plaster in single coat with water proofing treatment.(1)1 cement : 4 coarse sand
12mm cement plaster of mix 1:6 (1cement : 6 fine sand )
15mm cement plaster of mix 1:6 (1cement : 6 fine sand )
12mm plinth plaster in single coat with water proofing treatment (1) 1 cement : 4 coarse sand
12mm cement plaster outer side G.F. of mix 1:6 (1 cement :6 fine sand)
12mm cement plaster inner side G.F. of mix 1:6 (1 cement : 6 fine sand)
12 MM thick plaster 1:4 outer wall below ground level and inner wall below plinth level in 15 cm width
Making grooves 10 to 12 mm widex 8mmdeep in plaster of the wallor in ceilingvertically or horizontally as required.
Making drip course in sun shade or FACIA as per direction ofengineer -in - charge including supply of allmaterials labour etc.required for propercompletion ofthe work.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (GF+FF+SF)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : :25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur green marble
25 mm thick Cement concrete floor with cement approved coarse sand and 2cm. Graded approved stone ballast laid in planels finished with 3mm (1/8") floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified over and including 8 cm. (3") local sand and brick ballast 4 cm. gause in proportion of 1:4:8 and removing any giving then a uniform finish,including supply of all materials, labour, T&P etc. required for proper completion of the work. But without base concrete.
Supply & fixing 6mm thick China White glazed tiles in flooring or in skirting or dado laid with 1:3 cement & approved coarse sand mortar finished with white cement slurry jointing & polishing complete including supply of all materials labours & tools etc. required for proper completion of work Ground Floor
Painting Ist coat over priming coat (butexcluding cost of priming coat) on steeland other metal surfaces up to 10 cm.width or girth or small articles notexceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of alldirt,dust and other foreign matter sandpapering and stoping including cost ofall materials, labour tools and plants etc. required for proper completion ofthe work.
Same as item above but on new wood surface.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. two coat
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes Ground Floor
Providing and fixing strips of 3mm thickness in joints of floor and skirting of the time of laying floors flush with floor level including labour, tools plants etc. complete 25mm dept
Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete 300x16 mm
Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete 250x16 mm
Providing and fixing ISI marked Stainless Steel tower bolt black finish, (Barrel type) with necessary screws etc. complete (a)250mm*10mm
Providing and fixing ISI marked Stainless Steel handles conforming to IS:4992 with necessary screws etc. complete (a) 125 mm
Providing & laying of light cinder filling under floor of toilets & other sunken roofs. First Floor
12 mm bearing plaster (1)1 cement:3coarse sand.
Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. With decorative veneering on one side and commercial veneering on other side
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
P/L in cement concrete 1: 2: 4 (1cement: 2 coarse sand : 4 graded stone grit 20mm nominal size and curing complete including cost of form work for fixing of hold fasts including of supply of all materials labour T&P etc.required for proper completion of work. Strength should not be less than M-20.
Providing and laying in position bitumen hot sealing compound for expansion joints etc.Using grade 'A' sealing compound.
Cartage of good earth for filling up to 5.00 k.m. distance including loading unloading.
Cartage of good earth for filling up to 5.00 k.m. distance including loading unloding and dressing, ramming watering proper with 20 cm layer not exceeding work executed as per direction E/I complete
SANITARY FIXTURES & ACCESSORIES : I Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require (a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Felxible pipe (a) 32mm dia
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Felxible pipe (b) 40mm dia
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing 15 mm dia. inlet C.P. brass Providing and Fixing C.P. Single flow overhead shower(With Arm) 100mm Dia
providing and fixing 600*450mm Bevelled edge mirror of superior glass complete with 6mm thick hard board ground fixed to wooden cleats with C.P.brass screws and washers complete
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (Internal Work) Expansion on Wall 32 mm dia nominal bore. (medium duty)
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. 32 mm diameter pipe.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.external work on terrace . 40 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.external work on terrace. 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.external work on terrace. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.internal work exposed on wall. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.internal work exposed on wall. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.internal work exposed on wall. 32 mm nominal outer dia Pipes
Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fittlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. (a) 110mm diameter New S.NO. 34
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (a) 110mm
WATER SUPPLY PIPES AND FITTINGS - III Providing & fixing CPVC pipes complete with CPVC fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall (a) 25mm dia nominal bore (medium duty)
Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. (a) 15mm dia nominal bore
Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. (b) 20mm dia nominal bore
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. (a) 15mm nominal bore
Providing & fixing CP brass short body of approved quality conforming to IS 8931 (a) 15mm nominal bore
Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (a) 15mm nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality. 25 mm nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality. 32 mm nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality. 40mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. (a) 20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. (b) 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ofIS 12701 approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (a) Circular Tank
Providing and fixing PTMT grating of approved quality and colour. Circular type-100 mm nominal dia
SCHEDULE OF QUANTITIES FOR INTERNAL SEWERAGE SYSTEM - IV Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (a) 15 mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (b) 20 mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (c) 25mm dia nominal outer dia pipes
providing and fixingof upvc SWR cowel confirming to IS 14735 (a) 90mm dia
Providing and fixingof upvc SWR cowel confirming to IS 14735 (b) 110mm dia
Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fittlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. New S.No. 34 (a) 110mm diameter pipes
Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fittlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. New S.No. 34 (a) (b) 160mm diameter pipes
Hanching of SWR pipe with PCC 1:2:4 (1 cement: 2 coarse sand: 4 stone grit) of cross-section 800 x 200 mm concrete. (a) 110mm diameter pipes
Hanching of SWR pipe with PCC 1:2:4 (1 cement: 2 coarse sand: 4 stone grit) of cross-section 800 x 200 mm concrete. (b) 160mm diameter pipes
S/F of upvc SWR Nahani Trap size100/90mm confirming to IS -14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 110mm dia
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80X50cms including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line
Extra for depth of man hole size 90x80x50 cm
EXTERNAL SEWERAGE SYSTEM Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fittlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. (a) 110mm diameter pipes .
Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fittlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. (b) 160mm diameter pipes.
Hanching of SWR pipe with PCC 1:2:4 (1 cement: 2 coarse sand: 4 stone grit) of cross-section 800 x 200 mm concrete. (a) 110mm diameter pipes
Hanching of SWR pipe with PCC 1:2:4 (1 cement: 2 coarse sand: 4 stone grit) of cross-section 800 x 200 mm concrete. (b) 160mm diameter pipes
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80X50cms including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line.
Providing and fixing OF U.P.V.C. S. W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick masonery chamber 250x250x250 mm size i/c supply and fixing of C.I. cover with frame weight not less than 4.50 kg. & C.I. grating 150x150mm complete in all respect.
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.
Septic Tank Earth work in excavation in trenches for foundations and pipes cables etc in ordinary soil (loan clay or sand) including lift upto 1.5 m, lead upto 50 m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer- in- charge with in a lead of 50m . In all kind of soil upto 1.5m depth
Earth work in excavation in trenches for foundations and pipes cables etc in ordinary soil (loan clay or sand) including lift upto 1.5 m, lead upto 50 m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer- in- charge with in a lead of 50m . In all kind of soil upto 1.5m to 3.0m. depth
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 stone ballast 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
Class 150 brick work in 1:6 cement and coarse sand of 1.50-2.00 fineness modulus mortar in foundation and plinth including supply of all materials, labour and tools and plants etc. required for proper completion of the work.
Class 150 brick work (half brick thick wall) in 1:4 cement and coarse sand (1.50-2.00 fineness modulus) mortar in foundation and plinth including necessary cutting and moulding of brick work as required and also including supply of all materials, labour and tools and plants etc. required for proper completion of the work.
2 cm thick cement plaster in dado of skirting in 12 consisting of one part of cement and two parts of approved coarse sand laid in panels, finished with 3j mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials, labour and tools and plants etc. required for proper completion of the work.
Providing & laying Cement Concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone ballast 20mm nominal size) including supply of materials labour and T&P etc. Required for proper complition of the work.
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3,(1cement :1.5corse sand 3 grit) in slab excluding supply of reinforcement and its fixing and bending but including its fixing and binding the same necessary with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works strength of concrete shall not be less than M-20 DSR 5.3
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
12 mm cement plaster in single coat on FAIR side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 C. sand
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
Providing and fixing of UPVC S.W.R. plain tee confirming to IS - 14735 of septic tank. Dia 110x110x110 mm size
Providing & fixing of UPVC S.W.R. Cowel dia 110 mm size
Providing & fixing of UPVC S.W.R. Cowel dia75 mm size
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. L.D. -2.5- Circular shape 450mm internal diameter
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing,commissioning etc. as required.
Providing and fixing circular/ Hexagonal GI box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick GI sheet with its top surface hacked for proper bonding, top lid shall be screwed into the GI box by means of 3.3 mm dia round headed screws, one lock at the corners, clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8 to 10 SWG G.I. wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
Supplying & Laying of 25 mmx5mm G.I. Strip for earthing purpose as required complete in all respects.
Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6 - 32 amps.Cat. A
Supplying and fixing 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp. 4 Pole MCB Cat. A
Supplying and fixing 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp. 4 Pole MCB C Curve-Cat. A
S&F of 63 Amp. 415 V metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. Cat B
S&F of 63 Amp. 4 Pole Isolator cat A
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required..
Supply and fixing of electronic fan regulator (Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
Add for Invertor Wiring in wiring Point for light/ Fan/ Plug with 1.5 mm Cu Wire
Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. Upto 35 sqm
S/F of recess/surface/pendent mounted 10 to 15 watt LED down lighter havig powder coated die cast aluminium housing body with heat sink, difuser/ refelector and driver set complete in all respect. Category AAA
Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light complete including tube etc. on surface complete in all respect. 1 X 22 W CAT-AAA
Supply of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required (Crompton Greaves/GEC/ORIENT/BAJAJ)
Supply of AC 230/250 volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete.(GEC/Crompton or equivalent make)a) 300 mm sweep 1400 rpm
India marks-II hand ISI market with Cylinder & Conection road complete.
Supply of 110mm dia plain PVC (6 kg/sqcm) Pressure
Supply of 75 mm dia plain PVC (6 kg/sqcm) Pressure
50mm dia PVC strainer 4mt Long ridded with stander trap & Spaciales
Supply of PVC Soket 110m dia
Nylon mesh narial rope around stariner
Supply of medium class GI pipe 32mm B class
Providing necessary boaring T&P including making arrangement of water for boaring 200mm dia bore hole by Rig machine in all type of starta complete item 30 metre B.G.L
Providing necessary boaring T&P including making arrangement of water for boaring 200mm dia bore hole by Rig machine in all type of starta complete item Beyond 30 metre
Supply of labour T&P and jointing & lowering of PVC pipe consisting of 110mm & 50 mm dia bore long ribbed PVC Strainer & Cavity complete 30 metre B.G.L
Supply of labour T&P and jointing & lowering of PVC pipe consisting of 110mm & 50 mm dia bore long ribbed PVC Strainer & Cavity complete Beyond 30 metre
Supply of labour T &P and jointing & lowering of PVC pipe consisting of 110mm & 50mm dia bore ribbed PVC strainer & cavity complete
Development of bore by manual labour till discharge is free from turbity complete item
Supply & using of PVC cemnt solvent
Supply of all material labour T & P required for proper completion of work to construct cement concrete (1:2:4) platform of 1.50 mt dia for hand pump as per drawing with P.C.C (1:5:10)
Supply of steel wire rope
Installation of India Marka-II hand pump over the bore hole as per direction of E/I and Installtion
Complete installation, testing and commissioning of the 5kw solar PV System, including module fixing structure, erection, inverter installation, cabling earthing, and performance testing. All works to be completed as per specification and direction of E/I
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.80 MB
Tech.pdf
Tender Documents • 8.50 MB
Fin.pdf
Tender Documents • 11.18 MB
BOQ_2034976.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid