| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.1 Cr+₹5 L (4.82%)Rejected-Finance CHALITIA BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | ₹1.1 Cr+₹5 L (4.82%) | L2 | Rejected-Finance 2nd lowest Bidder |
| 3 | L3₹1.2 Cr+₹11.4 L (11.0%)Rejected-Finance | ₹1.2 Cr+₹11.4 L (11.0%) | L3 | Rejected-Finance 3rd lowest Bidder |
| Sl No | Description | Qty | Unit | DAS TRADING CO L3 | AAP ENGINEERING L1 | G.M.N. ENGINEERING L2 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of Condensing unit with minimum 102000 btu/hr or higher Cooling capacity, with 1 nos., Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controller of minimum 8.5 TR or higher nominal capacity with Green Refrigerant. (Make : Mitsubishi/O General/Mitshubishi Heavy Industries) | 16 | Nos. | 2,80,000 ₹44,80,000 | 2,25,000 ₹36,00,000 Lowest | 2,50,000 ₹40,00,000 |
| 2.00 | SITC of Double skin construction Floor Mounting/Ceiling Suspended Air Handling Unit with Thermal Brake profile, Combination Filter ( Pre filter with 20µ Filter & Fine Filter with 5µ Filter and Hepa filter(Make: Zeco/AFI/Spectrum/Aeropure)) , Cooling Coil Section suitable for R410 refrigerant with 6RD DX Cooling Coil and SS304 Drain Tray, Direct/Belt driven Backward curve with EFF-1 motor(Make-Kruger/Haveals/L&T) , VFD(Electromec/L&T/Haveals) and SAD(Make-Dynacraft/Primier) , Fan-Motor Mounting Base, Drive Motor with V-Belt Drive Package, Vibration Isolators and Fire Retardant Flexible Canvas Connector. Air Handling Unit shall have 40 mm thick Sandwich Insulated Panels with Thermal Break Profile with Pre-Coated GSS Outer Skin and 0.6 MM Thick Plain GSS Inner Skin 0.6 and with Extruded Aluminium Frame Structure. VCD in Aluminium aerofoil construction to be provided in SA, FA, RA Openings. (Make: Waves/ Zeco / VTS)
AHU -6600 CFM /100 MM Static / 6RD DX COIL / Thermal brake profile /VFD
(An Autocadd Generated Drawing has to be approved before starting of any construction) | 8 | Nos. | 3,20,000 ₹25,60,000 | 2,87,500 ₹23,00,000 Lowest | 3,00,000 ₹24,00,000 |
| 3.00 | SITC of Refrigeration Valves, Controls - Expansion Valves, Dryer etc. (Mk. Honeywell / Dynafoss) | 8 | Nos. | 8,938 ₹71,504 Lowest | 8,938 ₹71,504 Lowest | 8,938 ₹71,504 Lowest |
| 4.00 | SITC of Micro Processor based Control Panel for 8.5 TR AC Machine Compressor and its accessories. Provision for 4 KW VFD(Electromec/L&T/Haveals/Selec) for 1 nos. AHU's.EFF - 1 AHU motor provide for 1 nos. Motrized fire Damper provision future interlock Panel should consists with the following items:
1. 100 Amps 4 Pole MCCB for incomer, 2. 63 Amp 4p MCB-1 Npo. 3. 32 Amps 4 Pole MCB 1 Nos. Compressor unit/ODU unit, Indication Lamp for Main unit(R,Y,B) 4. VFD on/off Indication Lamp 5. Selector Switch for Compressor 1 6. Power terminal 150 Amps. for motor connection, 230V /24 volts 30 VA Transformer for Fire Damperf Controller. 7. MF meter with selector switch 0 - 60 AMPs, 8. CT 60/5 Amp Class -1 8. ON /OFF Push Bottom 9. Wall mounted type , 2 mm/1.6 mm thick CRCA sheet steel Fabricated duly painted powder coated Siemens gray.(415 V, 3Ph, 4 Wire , 50 Hz) top and Bottom Entry, Indoor type IP - 54 Housing,.(An Autocad Generated Drawing has to be approved before starting of any construction) | 8 | Nos. | 1,49,713 ₹11,97,704 Lowest | 1,49,713 ₹11,97,704 Lowest | 1,49,713 ₹11,97,704 Lowest |
| 5.00 | Supply and fixing of UVC EMIITTER for the above IDUs for prevention of fungus in the cooling coils, The minimum UV intensity in the coils shall be 700-800 UW-SEC/CM2. The unit shall be UL.Listed (UL-1995) and it should be suitable to fix the same in 11TR & 5.5TR IDU (Make-Alfa / Ruks). | 8 | Nos. | 22,122 ₹1,76,976 Lowest | 22,122 ₹1,76,976 Lowest | 22,122 ₹1,76,976 Lowest |
| 6.00Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410 refrigerant & 13 mm thick Nitrile Rubber Insulation tube with supports & brackets as per direction of EIC. | ||||||
| 6.01 | a. Liquid Line (11/8" dia) with 13 mm thick nitrile rubber insulation with Al. Foil covered(Cu Pipe Make- Rajko/Ryoku/Nippon) (Insulation make - Accroflex/Suprime) | 280 | Mtrs. | 947 ₹2,65,160 Lowest | 947 ₹2,65,160 Lowest | 947 ₹2,65,160 Lowest |
| 6.02 | c. Suction Line (5/8" dia) with 13 mm thick nitrile rubber insulation al foil covered(Cu Pipe Make- Rajko/Ryoku/Nippon)(Insulation make - Accroflex/Suprime) | 280 | Mtrs. | 411 ₹1,15,080 Lowest | 411 ₹1,15,080 Lowest | 411 ₹1,15,080 Lowest |
| 7.00S & L of Copper Control Cabling FRLSH from Condensing Unit to Control Panel (make - Polycab / Havell's/Finolex) | ||||||
| 7.01 | a) 4 Core 6 sq. mm. (from AHU Panel to AHU) | 210 | Mtrs. | 378 ₹79,380 Lowest | 378 ₹79,380 Lowest | 378 ₹79,380 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
6 Mar 2026, 2:30 pmClosed
SENIOR SUPERINTENDING ENGINEER
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
SITC of Air Conditioning System and allied Electrical Installation works at Antenatal ward and Post Natal Ward of Tamralipto Govt. Medical College and Hospital
2026_WBPWD_1003891_1
WBPWD/SSE/SWEC/NIQ144/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
PURBA MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹2.0 L
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER
1 Sept 2026
11 Feb 2026
9 Mar 2026
11 Feb 2026
6 Mar 2026
13 Feb 2026
13 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of Condensing unit with minimum 102000 btu/hr or higher Cooling capacity, with 1 nos., Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controller of minimum 8.5 TR or higher nominal capacity with Green Refrigerant. (Make : Mitsubishi/O General/Mitshubishi Heavy Industries) | |||||
| 2SITC of Double skin construction Floor Mounting/Ceiling Suspended Air Handling Unit with Thermal Brake profile, Combination Filter ( Pre filter with 20µ Filter & Fine Filter with 5µ Filter and Hepa filter(Make: Zeco/AFI/Spectrum/Aeropure)) , Cooling Coil Section suitable for R410 refrigerant with 6RD DX Cooling Coil and SS304 Drain Tray, Direct/Belt driven Backward curve with EFF-1 motor(Make-Kruger/Haveals/L&T) , VFD(Electromec/L&T/Haveals) and SAD(Make-Dynacraft/Primier) , Fan-Motor Mounting Base, Drive Motor with V-Belt Drive Package, Vibration Isolators and Fire Retardant Flexible Canvas Connector. Air Handling Unit shall have 40 mm thick Sandwich Insulated Panels with Thermal Break Profile with Pre-Coated GSS Outer Skin and 0.6 MM Thick Plain GSS Inner Skin 0.6 and with Extruded Aluminium Frame Structure. VCD in Aluminium aerofoil construction to be provided in SA, FA, RA Openings. (Make: Waves/ Zeco / VTS) AHU -6600 CFM /100 MM Static / 6RD DX COIL / Thermal brake profile /VFD (An Autocadd Generated Drawing has to be approved before starting of any construction) | |||||
| - | SITC of Refrigeration Valves, Controls - Expansion Valves, Dryer etc. (Mk. Honeywell / Dynafoss) | - | Nos. | - | - |
| - | SITC of Micro Processor based Control Panel for 8.5 TR AC Machine Compressor and its accessories. Provision for 4 KW VFD(Electromec/L&T/Haveals/Selec) for 1 nos. AHU's.EFF - 1 AHU motor provide for 1 nos. Motrized fire Damper provision future interlock Panel should consists with the following items:
1. 100 Amps 4 Pole MCCB for incomer, 2. 63 Amp 4p MCB-1 Npo. 3. 32 Amps 4 Pole MCB 1 Nos. Compressor unit/ODU unit, Indication Lamp for Main unit(R,Y,B) 4. VFD on/off Indication Lamp 5. Selector Switch for Compressor 1 6. Power terminal 150 Amps. for motor connection, 230V /24 volts 30 VA Transformer for Fire Damperf Controller. 7. MF meter with selector switch 0 - 60 AMPs, 8. CT 60/5 Amp Class -1 8. ON /OFF Push Bottom 9. Wall mounted type , 2 mm/1.6 mm thick CRCA sheet steel Fabricated duly painted powder coated Siemens gray.(415 V, 3Ph, 4 Wire , 50 Hz) top and Bottom Entry, Indoor type IP - 54 Housing,.(An Autocad Generated Drawing has to be approved before starting of any construction) | - | Nos. | - | - |
| - | Supply and fixing of UVC EMIITTER for the above IDUs for prevention of fungus in the cooling coils, The minimum UV intensity in the coils shall be 700-800 UW-SEC/CM2. The unit shall be UL.Listed (UL-1995) and it should be suitable to fix the same in 11TR & 5.5TR IDU (Make-Alfa / Ruks). | - | Nos. | - | - |
| - | Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410 refrigerant & 13 mm thick Nitrile Rubber Insulation tube with supports & brackets as per direction of EIC. | - | - | - | - |
| 6.01 | a. Liquid Line (11/8" dia) with 13 mm thick nitrile rubber insulation with Al. Foil covered(Cu Pipe Make- Rajko/Ryoku/Nippon) (Insulation make - Accroflex/Suprime) | - | Mtrs. | - | - |
| 6.02 | c. Suction Line (5/8" dia) with 13 mm thick nitrile rubber insulation al foil covered(Cu Pipe Make- Rajko/Ryoku/Nippon)(Insulation make - Accroflex/Suprime) | - | Mtrs. | - | - |
| - | S & L of Copper Control Cabling FRLSH from Condensing Unit to Control Panel (make - Polycab / Havell's/Finolex) | - | - | - | - |
| 7.01 | a) 4 Core 6 sq. mm. (from AHU Panel to AHU) | - | Mtrs. | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 1.83 MB
BOQ_2461435.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .