Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹560.4 CrAccepted-AOC CRYSTAL TOWER 4TH FLOOR TELIBANDHA RAIPUR | RAIPUR | RAIPUR | CHHATTISGARH | ₹560.4 Cr Quoted ₹563.0 Cr | 1 | Accepted-AOC Work allotted |
| 2 | 2₹565.8 CrRejected-AOC A 177 OKHLA INDUSTRIAL AREA PHASE I NEW DELHI 110020 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110020 | ₹565.8 Cr | 2 | Rejected-AOC Not allotted |
| 3 | 3₹599.4 CrRejected-AOC NCC HOUSE MADHAPUR HYDERABAD 500081 TELANGANA INDIA TELEPHONE 040 23268730 | ₹599.4 Cr | 3 | Rejected-AOC Not allotted |
Tender Value
Refer Docs
EMD Value
₹10.5 Cr
Closing Date
24 Dec 2020, 5:00 pmClosed
Superintending Engineer Kaithal Circle, PWD BandR
Superintending Engineer Kaithal Circle, PWD BandR Kaithal
Construction of Medical College at Jind in Jind Distt.
2020_HRY_150088_1
PWD/Jind/Construction of Medcial College at Jind
Open Tender
Civil Works - Buildings
912 days
Jind
Please refer Tender documents.
3 documents required · 3 mandatory
₹50,000
Yes
₹10.5 Cr
Yes
Superintending Engineer Kaithal Circle, PWD BandR
24 Feb 2021
7 Nov 2020
28 Dec 2020
7 Nov 2020
24 Dec 2020
7 Nov 2020
13 Nov 2020
Amount
CARRIAGE OF MATERIALS
Carriage of materials by mechanical transport including loading, unloading and stacking (distance of 10 Km ) (DSR 1.1)
Earth (DSR 1.1.2)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (DSR 2.6)
All Kinds of soil (DSR 2.6.1)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. (DSR 2.7)
Ordinary Rock (DSR 2.7.1)
Hard rock (blasting prohibited (DSR 2.7.3)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (DSR 2.10)
All Kinds of soil (DSR 2.10.1))
Pipes, cables etc. not exceeding 80 mm dia. (DSR 2.10.1.1)
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (DSR 2.10.1.2)
Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia (DSR 2.10.1.3)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (DSR 2.13)
Ordinary rock (DSR 2.13.1)
Pipes, cables etc. not exceeding 80 mm dia. (DSR 2.13.1.1)
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (DSR 2.13.1.2)
Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia (DSR 2.13.1.3)
Extra rates for quantities of works, executed: (DSR 2.24)
In or under water and/or liquid mud, including pumping out water as required (DSR 2.24.1)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR 2.25)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (DSR 2.25 (a))
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26)
All Kinds of soil (DSR 2.26.1)
Ordinary or hard rock (DSR 2.26.2)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR 2.27)
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
All kinds of soil (DSR 2.28.1)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. (DSR 2.31)
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR 2.32)
Supplying chemical emulsion in sealed containers including delivery as specified. (DSR2.34)
Chlorpyriphos/ Lindane emulsifiable concentrate of 20% (DSR 2.34.1)
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / Sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.1.1)
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.3.1)
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. (DSR 4.1)
1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) (DSR 4.1.4)
1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size) (DSR 4.1.6)
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (DSR 4.1.8)
1:5:10 (1 Cement : 5 coarse sand (zone-III) : 10graded stone aggregate 40 mm nominal size) (DSR 4.1.10)
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. (DSR 4.4)
1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (DSR 4.4.1)
Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size), including necessary excavation of size 250x250x450mm deep for the same in bitumen/ concrete pavement at specified spacing. (DSR 4.9)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). (DSR 4.11)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (DSR 4.12)
Extra for concrete work in superstructure above floor V level for each four floors or part thereof. (DSR 4.14)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR 4.17)
R.C.C WORK
Centering and shuttering including strutting, propping etc. and removal of form for all heights : (DSR 5.9)
Foundations, footings, bases of columns etc. for mass concrete. (DSR 5.9.1)
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2)
Suspended floors, roofs, landings, balconies and access platform. (DSR 5.9.3)
Shelves (Cast in situ) (DSR 5.9.4)
Lintels, beams, plinth beams, girders, bressumers and cantilevers. (DSR 5.9.5)
Columns, Pillars, Piers, Abutments, Posts and Struts. (DSR 5.9.6)
Stairs, (excluding landings) except spiral - staircases. (DSR 5.9.7)
Extra for shuttering in circular work (20% of respective centering and shuttering items) (DSR 5.9.14)
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15)
Edges of slabs and breaks in floors and walls (DSR 5.9.16)
under 20 cm wide (DSR 5.9.16.1)
Cornices and mouldings (DSR 5.9.17)
Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19)
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 Metre or part thereof (Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) (DSR 5.11.1)
Providing and fixing of costomized Aluminium formwork for monolithic construction RCC members with a repetitive usage of 10-20 times using grade 5052 aluminium for panel sheets of minimum 4 mm thick and grade 6061 (Type-6) aluminium for extrudedsections. The form work includes of beam components i.e.beam side panel,prop head for soffit beam,beams soffit panel,beam soffit bulk head and deck componets i.e. deck panel, deck prop, prop length, deck mid, soffit length, deck beam bar and wall components i.e. wall panel, rocker, kiker and internal soffit corner, external soffit corner,external corner,internal corner etc.,The panels are held in position by a simple pin and wedge system that passes through holes in the out side rib of each panel.The tolerance of finished panels to be (-1 mm), and shall conform to IS 14687-1999. Pins and wedges to be made of high grade mild steel, all complete as per direction of Engineer-incharge.(Cost of RCC work shall be paid seperately) (MR)
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (DSR 5.12)
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
50 mm thick (DSR 5.18.1)
Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Upto plinth level
Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22A 6)
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. (DSR 5.30)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). (DSR 5.37)
All work upto plinth level (DSR 5.37.1)
All work from plinth level upto floor V level. (DSR 5.37.2)
Extra for providing richer mixes at all floor levels. (DSR 5.34)
Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) (DSR 5.34.1)
Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-35 is @ 350 kg/cum) (DSR 5.34.2)
Providing M-40 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-40 is @ 360 kg/cum) (DSR 5.34.3)
Add for using extra cement in the items of design mix over and above the specified cement content therein. (DSR 5.35)
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. (DSR 5.38)
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered selfcentering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063.) (DSR 5.44) Floor Joint of 100 mm gap (DSR 5.44.1)
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063.) (DSR 5.45) Wall Joint of 100 mm gap (DSR 5.45.1)
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer- In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063) (DSR 5.46)
Roof Joint of 100 mm gap (DSR 5.46.1)
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1)
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2)
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : (DSR 6.34)
Cement mortar 1:6 (1 Cement : 6 coarse sand) (DSR 6.34.2)
Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand) (DSR 6.45.2)
Extra for providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of half brick masonry (with F.P.S. bricks) (DSR 6.15)
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. (DSR 6.14)
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) (DSR 6.47)
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work (DSR 6.38)
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. (DSR 6.5)
CLADDING WORK
Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. (DSR 7.33)
Red sand stone(DSR 7.33.1)
White sand stone (DSR 7.33.2)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (DRS 8.2) Granite of any colour and shade (DSR 8.2.2) Area of slab over 0.50 Sqm (DSR 8.2.2.2)
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2)
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR 8.4)
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR 8.5)
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite (DSR 8.10) Stone of approved shade (DSR 8.10.2)
Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of. (DSR 8.19)
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). (DSR 8.20)
Red sand stone - 30mm thick gang saw cut stone (DSR 8.20.1)
White sand stone - 30mm thick gang saw cut stone (DRS 8.20.2)
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shutering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). (DSR 8.21)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 8.31)
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge (DRS 8.22)
Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete : (DSR 8.26) 25 mm thick (DRS 8.26.3)
Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. (DSR 8.11.1)
Acoustical Wooden Panelling
Providing and Fixing Armstrong Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architect/ approving engineer, made of a high density fibre board with minimum 595 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 5mm/ 13mm/ 21mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.59. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Architect/ Engineer-in-Charge. (MR-1)
INSTALLATION: Install wooden battens (provided by others) of section 50x50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks provided by Armstrong over the lowest and second wooden batten at an on-centre distance of 600mm. Install the Skirting (provided by others) of width 50mm or more as required by the Architect/ Engineer-in-Charge and insert the tongue end of the panel in the skirting. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour (provided by others). Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure.
Acoustical Fabric wall Panelling
Providing and fixing Armstrong ‘Optra Acoustical Wall Panelling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction ASTM E-84 : Class A fabric with an option of colors – Husk JT-06, Copper JT-13, Sangria JT-17, Sesame VL-27B, Coffee VL-08N, Charcoal JT-14, Titanium JT-07, Flame JT-16, Peanut JT-12, Shell VL-22 as per the choice of the Architect of size 600X600/1200/1800 mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel impalers supplied by M/s Armstrong Industries India Pvt Ltd or equivalent and construction adhesives as per the instructions laid down by the manufacturer. (MR-4)
INSTALLATION: 3/4/5 nos. Armstrong wall panel Impalers of shall be fixed to the wall surface using self-tapping screws. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers. Armstrong Optra wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are maintained. Installation to be carried out by Armstrong Trained Installation team or equivalent & Installation should be carried out as per Manufacture's recommended procedure.
WOOD WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal Wood (DSR 9.1.2)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters (DSR 9.5.1.1)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood (DSR 9.27.1.1.1)
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square (DSR 9.24.1)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). (DSR 9.53)
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 125x64x2.50 mm (DSR 9.71.1)
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 Kg to 80 Kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (DSR 9.84)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm (DSR 9.74.1)
Providing and fixing bright finished brass handles with screws etc. complete 125 mm (DSR 9.81.1)
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (DSR 9.82)
Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 300 mm weighing not less than 330 gms (DSR 9.86.1)
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. (DSR 9.103)
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading (DSR 9.135.2)
providing & fixing glass panes,4.0 mm thick with putty and nails wherever necessary (DSR 14.5.1)
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) (DSR 9.147 A)
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) (DSR 9.147 A 1)
Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). (9.147 A4)
Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm). (DSR 9.147 A6)
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. (DSR 9.139)
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 Each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). (DSR 9.161)
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 Kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately). (DSR 9.162)
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm (DSR 9.164)
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm (DSR 9.165.1)
Providing and fixing AntiMicrobial stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete of make Williams Architectural , Daro , Gainsborough 125x64x2.50 mm (MR)
Providing and fixing Anti Microbial Stainless Steel door closer (door weight upto 36 Kg to 80 Kg and door width from 701 mm to 1200 mm), with necessary accessories and screws etc. complete of make Williams Architectural , Daro , Gainsborough (MR)
Providing and fixing bright finished Anti Microbial brass satin chrome plate tower bolts (barrel type) with necessary screws etc. complete of make Williams Architectural , Daro ,Gainsborough 250x10 mm (MR)
Providing and fixing Anti Microbial bright finished brass handles with screws etc. complete of make Williams Architectural , Daro ,Gainsborough 125 mm (MR)
Providing and fixing Anti Microbial bright finished brass handles with screws etc. complete of make Williams Architectural , Daro ,Gainsborough 500 mm (MR)
Providing and fixing Anti Microbial bright finished brass hanging type floor door stopper with necessary screws, etc. complete of make Williams Architectural , Daro ,Gainsborough (MR)
Providing and fixing Anti Microbial bright finished brass casement stays (straight peg type) with necessary screws etc. complete of make Williams Architectural , Daro ,Gainsborough 300 mm weighing not less than 330 gms (MR)
Providing and fixing Anti Microbial bright finished brass 100 mm mortice latch and lock,with six levers and a pair of Anti Microbial Stainless Steel lever handles of approved quality with necessary screws etc. complete. of make , Williams Architectural , Daro ,Gainsborough (MR)
STEEL WORK
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.1)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.2)
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. (DSR 10.3)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover. (DSR 10.6.1)
Providing and fixing ball bearing for rolling shutters. (DSR 10.7)
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 16.80 sqm in area (DSR 10.8.1)
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured). (DSR 10.9)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B (DSR 10.14)
Profile B Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.14.1.2)
Profile C Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.14.2.2)
Profile E Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.14.3.2)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes (DSR 10.16.2)
Providing and fixing bolts including nuts and washers complete. (DSR10.20)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2)
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer M.S. tube (DSR 10.26.1)
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10x 160 mm (DSR 10.27.5)
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.30)
4 mm thick glass panes (DSR 10.30.1)
5.5 mm thick glass panes (DSR 10.30.2)
Providing and fixing structural steel frame (for stone jali) at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing including cost of cutting, bending, welding etc. The frame work shall be supported in wall with the help of MS brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) of size 300x200x300mm including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal and vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel clamps shall be paid for separately and nothing extra shall be paid.) (MR)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR 10.28)
Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x 60 cm of mix 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and (DSR 16.20)
Supplying at site Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming &Painting to be paid for separately). (DSR 16.15.2)
FLOORING WORK
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 Kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.5)
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick (DSR 11.6.1)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick (DSR 11.26.1)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR 11.27)
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (DSR 11.40)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joints with white cement and matching pigments etc., The tile must be cut with zero chipping diamond cutter only, laying of tile will be done with the notch trowel, plier, wedge, clips of required thickness, Levelling system and rubber mallet for placing the tiles gently and easily. (DSR 11.41 A)
Double Charge Vitrified Tile of Polished finish of size Size of Tile 600 x 600 mm (DSR 11.41A.1.1)
Double Charge Vitrified Tile of Polished finish of size Size of Tile 800x800 mm (DSR 11.41A.1.2)
Glazed Vitrified Tile Matt/ Antiskid finish of size Size of Tile 600 x 600 mm (DSR 11.41A.3.1)
Glazed Vitrified Tile Matt/ Antiskid finish of size Size of Tile 800x800 mm (DSR 11.41A.3.3)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm (DSR 11.46.2)
Providing and laying Digital print random design (PGVT)/(GVT) vitrified tiles in different sizes, with water absorption less than 0.05 % and conforming to I.S. 15622, of approved make in all colours and shade,Ist quality premium in skirting,riser,Dedo laid on 12 mm thick cement mortar 1:3 (1 cement: 3 sand), including grouting the joint with white cement and matching pigments etc. complete. For skirting,riser,dedo etc. glossy/rustic/satin/matt finish in all colours and shades.
Size 600x600 mm thickness 9-10 mm (MR)
Size 600x1200 mm thickness 11-12 mm (MR)
Providing & fixing 10.5 mm thick (Armstrong /FloorMaster) engineerwood flooring american exotic bruce 7 layer construction,top layer of wood veener 2mm ,plank size width 120 mm ,length 400-1200 mm,Lock & fold locking ,premium finish,micro bevel edges/ends with an underlayment made of natural colour foam,with accessories like end profile,transition profile,reducer ,etc.complete.The profiles are 100% matching. profile at door openings (MR)
Providing and fixing of 10 mm thick FloorMaster/Egger Laminated wooden flooring Classification of Use 23/32 (Heavy Domestic/General Commercial) with a Surface Abrasion Resistance of class AC4 (average 4500 cycles), Impact Resistance of IC2 (EN13329), Resistance to Cigarette Burn with a rating of 5 (EN 438-2:15), Swelling after 24 hrs in water of 15% (EN13329), Modulus of Rupture of 53.3 newton/mm2, Internal Bond 1.78 newton/mm2, Surface Soundness of 1.3 newton/mm2 (EN 13329:2000) with a 0.2mm thick wear layer on top of a High Density Fiber substrate core (density > 850 Kg/M3) of plank size 1291 mm X 135 mm having Uni fit locking arrangement (lock strength > 1000 lbs/ft) with an underlayment made of natural colour foam , with accessories like End profile, Transition profile, reducer, etc. complete. The rate includes cost of all materials, accessories, labour, HOM, etc., complete at all levels. (The Shade, pattern etc., to be approved by Engineer in charge). (MR)
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement (DSR 11.20.1)
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. (DSR 11.51.1)
Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. (DSR 11.52.1)
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (DSR 11.55.1)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent (DSR 11.56.1)
Providing and laying Marble stone flooring in required design and patterns, all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Jaisalmer Yellow Marble (MR)
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (DSR 11.23)
Makrana white marble (DSR 11.23.1)
Udaipur green marble (DSR 11.23.5)
Supply & fixing flexible Medintech plus /simpurity range pvc sheet flooring in 2 mm thickness in the size of 2 mtr X 20 mtr use area classification 23/34/43 results from independent testing demonstrate that product inherently inhibits the growth of microbial strain MRSA. It shall be homogeneous in construction. The flooring shall incorporated a specially (PUR) to give polish free maintenance imported pvc vinyl flooring with total weight 28oo g/m2,dimensional stability EN-434, static electrical charge <2kv, impact sound reduction approx ISO 717-2, good resistant to scratch,slip,fire ,chemical & does not favor in growth fungi & bacteria Make –Armstrong or equivalent (MR)
Providing & Fixing of Forbo Flotex color/linear series flocked floor covering rolls having a density of 70 million fibres of nylon 6.6 per Sqm , Fire Test EN-13501, Appearence Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, sanitized anti-microbial treatment with resilient waterproof backing ,anti allergic cetrtified by British allergy foundation, anti static, stain resistant, thickness 4.3 mm and approximate weight of 4.5 k.g./sqm of roll form with acoustic sound impact 17dB. Flotex to be installed over cement based smooth level hard flooring( Made in United Kingdom).. The carpet should be laid complete including SS edge profile at door (MR)
Providing and laying Trimix flooring consisting 1:1:2 M-25 150 mm thick laid over base of 100 mm thick cement concrete 1:4:8 including dewatering and vibrating with double beam vibrator including cutting of the panells complete in all respects. (NS) (MR)
ROOFING WORK
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase (DSR 12.21.1)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. (DSR 12.22)
Providing and fixing flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 marked, in ceiling with necessary nails etc. complete (frame work to be paid separately): 12 mm thick (DSR 12.25.1)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter (DSR 12.41.2)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ ccessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm (DSR 12.42.6.2)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm (DSR 12.43.2)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board (DSR 12.45.3)
Providing & fixing UV stabilised fiberglass reinforced plastic sheetroofing up to any pitch, including fixing with polymer coated 'J' or 'L'hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers completebut excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified 2 mm thick flat (DSR 12.47.2)
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape (DRS 12.50)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete (DRS 12.51)
Ridges plain (500 - 600mm) (DSR 12.51.1)
Gutter (600 mm over all girth (DSR 12.51.6)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.52)
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (DSR 12.52.1)
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (DSR 12.52.2)
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. (DSR 12.55)
FINISHING WORK
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (DSR 13.1.1)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 Cement : 4 fine sand) (DSR 13.2.1)
6 mm cement plaster to ceiling of mix : 1:3 (1 Cement : 3 fine sand) (DSR 13.16.1)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR 13.21)
Neat cement punning. (DSR 13.18)
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. (DSR 13.22)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (DSR 13.26)
White washing with lime to give an even shade : New work (three or more coats) (DSR 13.37.1)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer (DSR 13.41.1)
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 Sqm) over and including priming coat of exterior primer applied @ 2.20Kg/ 10 Sqm (DSR 13.45.1)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @0.75 ltr/10 Sqm of approved brand and manufacture (DSR 13.48.2)
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @ 0.80 ltr/10 Sqm of approved brand and manufacture (DSR 13.48.3)
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. (DSR 13.48 A)
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (DSR 13.48A-1)
Applying priming coat: (DSR 13.50)
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) (DSR 13.50.1)
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (DSR 13.50.3)
Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work (DSR 13.69.1)
Providing & fixing galvanished chicken wire mesh in 125 mm wide strip with average width of aperture 1.18 mm and nominal dia of wire 0.556 mm at acs junctions of R.C.C column, beam with Brick work before plaster work. (MR)
Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). (DSR 13.72)
Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-inCharge (DSR 13.76)
Extra for washed grit plaster on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof (DSR 13.74)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80)
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats (DSR 13.82.2)
ALUMINIUM WORK
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion (DRS 21.1)
Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) (DSR 21.1.2)
Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge (DSR 21.2)
Pre-laminated particle board with decorative lamination on both sides (DSR 21.2.2)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3)
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) (DSR 21.3.2)
With float glass panes of 8 mm thickness (weight not less than 20 kg/ sqm (DSR 21.3.3)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. (DSR 21.10)
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. (DSR 21.13)
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge (DSR 21.16)
Powder coated minimum thickness 50 micron aluminium (DSR 21.16.2)
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge. (Only weight of grill to be measured for payment). (DSR 21.17)
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). (DSR 21.18)
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 (DSR 21.19)
Upto 20 mm depth and 20 mm width (DSR 21.19.3)
Providing and fixing 50 micron thick Frosted heat /light control film to window/door glazing as marketed under the brand name garware/3M or equivalent as approved. (MR)
WATER PROOFING
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (DSR 22.1)
(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Using rough Kota stone (DSR 22.1.1)
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : (DSR 22.2)
Using rough Kota stone (DSR 22.2.1)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations (DSR 22.7)
a) Applying and grouting a slurry coat of neat cement using 2.75 Kg/sqm of cement admixed with water proofing compound conforming to IS.2645 and approved by Engineer-in-charge over the Reinforced cement concrete slab including adjoining walls upto 300mm height including cleaning the surface before treatment.
b) Laying brick bats with mortar using broken bricks/bricks bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
c) After two days of proper curing applying second coat of cement slurry using 2.75Kg/sqm of cement admixed with water proofing compound conforming to IS : 2645.and approved by Engineer-in-charge.
d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 ( 1 cement : 4 coarse sand) admixed water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge inclding laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 X 300 mm square.3mm deep.
e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-charge
(i) With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (DSR 22.7.1)
Waterproofing of Raft/Base Slab : Supplying & installing positive side waterproofing treatment for “Raft Slab/Base Slab” by using Pre applied, flexible, fully bonded sheet membrane of minimum 3.5mm thickness before casting of the base RCC slab. Fully bonded sheet membrane does not require dry PCC/blinding concrete and can be installed on wet/damp PCC as long as PCC is free from ponded water. Fully bonded sheet membrane should have sufficient high puncture resistance and does not require protection screed protection also & steel reinforcement can be laid directly over the robust membrane allowing faster construction. Fully bonded sheet membrane shall have DUO SELVEDGE, one self adhesive & other using heat gun. Duo Selvedge will ensure dual lap sealing & 3.5mm thick fully bonded membrane shall have lap adhesion of minimum 1500 N/M and provide an intimate bond to the underneath of the poured concrete used as base/ raft slab to resist water migration. Membrane should be supplied with original manufacturer's Material Test Certificate (MTC) & CE marking & membrane should be installed in strict accordance with original manufacturer's instructions and contractor should produce method statement from original product manufacturer (private label supplier are not acceptable). The fully bonded sheet membrane shall consist of a multi layer composite film which consists of high performance SBS and polyester reinforcement and a trafficable weather resistant carbon crystals layer . Fully bonded sheet membrane shall be chemically resistant in all types of soil or water and is unaffected by ground settlement beneath slabs. The fully bonded sheet waterproofing membrane shall have following typical properties : 1) Peel Adhesion to Concrete > 3400 N/M (per ASTM D 903) 2) Tear Strength MD > 600 N (as per ASTM D 5147) 3) Resistance to Hydrostatic Head > 110M (as per ASTM D 5385) 4) Puncture Resistance > 1050 N (as per ASTM E 154) Fully bonded sheet membrane shall be laid over the entire area and returned on to a vertical slab formwork. No Screed Protection Required for Fully Bonded sheet Membrane Allowing Faster Construction. Approved Makes : Colphene of Soprema , Sintec, Isoltema (MR)
4.5mm thick fully bonded membrane shall be installed with minimum standard 100 mm selvedge laps. Selvedge shall be Duo Selvedge, 55mm self adhesive and 45mm thermofusible film over entire area and turned up on to a vertical timber formwork/blockwork , as per recommendations/drawings. The membrane shall be laid over the concrete blinding having uniform surface including necessary removal of release liner on the selvedge while applying, necessary overlaps between the membranes , firm rolling onto the surface to get a tight seal, etc. complete all as per manufacturer’s recommendations, etc. complete with all lead and lift for all materials and labour and as directed by engineer in charge. Colphene BSW or equivalent. Approved Makes : Soprema, France or equivalent
Waterproofing of Un-Confined Retaining Wall: Supplying & Installing 1.5mm thick self adhesive , cold applied , flexible waterproofing membrane comprising of a self adhesive rubberized asphalt with tri-laminated polyethylene film . Membrane should be supplied with original manufacturer's Material Test Certificate (MTC) & membrane should be installed in strict accordance with original manufacturer's instructions. Self adhesive membrane shall have following minimum properties : (i) Lap Adhesion : > 2000 N/M , (ii) Thickness : 1.5mm , (iii) Tear Resistance : > 400 N ; (iv) Puncture Resistance : >375N. Rates to include self adhesive membrane Termination on retaining wall which includes providing a chase of (20 x 20) mm at a distance of 300 mm from ground level or 150 mm from podium/roof slab level for membrane termination. The self adhesive membrane should be dressed into the chase and pointed with mortar or as approved by supplier prior to backfilling . All system to be installed as per supplier's recommendations, etc. complete with all lead and lift for all materials & labour & as directed by Engineer in-charge. The membrane shall be applied as per following procedure a) Clean the RCC surface free from dust with brush. Remove any sharp protrusions on the RCC wall by chipping and local repairs. b) Apply solvent based local primer on the surface and allow to dry c) Roll out membrane, cut it to manageable lengths and stick it to the surface by peeling off the release paper on the back of the membrane. Press membrane in place. Roll the laps and joints by hand roller. Approved Makes : Colphene 3000 of Soprema, France ; Elotene 3000X of Isoltema, Italy or equivalent (MR)
Retaining Wall Membrane Protection: Protection of membrane with Supply & spot bonding 7-8mm thick dimpled HDPE protection board, spot bonded onto the self adhesive membrane with liquid mastic. and shall be applied prior to backfilling.The backfilling shall be done within 2-3 days of fixing protection board. Approved Makes : Protecdrain of Soprema, France; Tema, Italy (MR)
OVER DECK WATERPROOFING (MR)
Providing and laying overdeck waterproofing treatment for Car Park, Podium and gardens over basement roof slab, all as per following specification and sketches carrying 10 years guarantee (Tenderer should submit the name of specialist agency).
a) Polymer modified comentecious slurry coating of DICHTAMENT DS+ NAFUFILL BB2 or equivalent as aprroved.
b) Polymer modified concrete screed 25mm thick using 8mm down aggregate (1:1:3) 1 Cement: 1 aggregate : 3 coarse sand admixed with special dichatment DM: 0.5% by weight of cement Nafufill SBR -5% by weight of cement manufactured by MC Bauchemie (I) Pvt. Ltd. or equivalent as approved.
c) All upstand masonry/RCC work with 20mm thick waterproof plaster (CM 1:4 admixed with DICHATMENT DM @ 200 ml per bag of cement or equivalent as approved by Owner)
d) All corner junctions with EMCEKRETE mortar (30x30) or equivalent as approved by Owner
e) Waterproof screed or coba (Average 100mm thick) in proper slope admixed with DICHTAMENT DM
f) Final coating of DICHTAMENT DS + NBB2 (dosage)
The treatment is to be carried out by a specialised agency with the approval of the consultant and shall be guaranteed fully effective for a period of ten years. Notwithstanding this, the responsibility of the effectiveness of the treatment shall be fully, entirely and unqualifiedly be that of the main contractor for the work.
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. (DSR 22.26)
STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (DSR 25.2)
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the periMetre for holding glass.
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories
(1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
(2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.
(3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml
(4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330- 10 testing method for a range upto 50 mm
(5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test Tests to be conducted on site.
Powder coated aluminium (minimum thickness of powder coating 50 micron)
(6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml (DSR 25.2)
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (DSR 25.3)
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)
For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in Sqm.
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. (DSR 25.1)
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. (DSR 25.4)
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (DSR 8.32)
(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (Each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (DSR 8.32)
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. (DSR 25.8)
The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete (DSR 25.5)
NEW TECHNOLOGIES AND MATERIALS
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. (DSR 26.27)
With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100 ) specifications (DSR 26.27.3)
Supply & Installation of LuxalonAluminium Plain 132S Vertical Louvers on both sides of opening consisting of panels manufactured from 0.6 mm thick aluminium alloy of height 132 mm & 98.5 mm wide of required length up to 5 meters in external Luxacote/ PVDF Finish in standard color. The module of the same will be 180.5mm. Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification. Coating - In-house Powder Coating line with Nano technology & catalytic converter in India: For superior powder coating finishes with automatic electrostatic robotic coating technology for uniform coating and Five (5) times cleaning process with Nano Technology for better adhesion and corrosion protection. Approved Makes - Hunter Douglas, COLT, CS (Construction Specialties) or equivaalent as approved. (MR)
LUXALON® Aluminium Panel Sun Louvres H-3 84R Plain Providing and fixing Luxalon® H-3 84R Plain Panel Sun Louvres manufactured by M/s. Hunter Douglas India Pvt. Ltd. or equivalent of approved standard colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6mtrs coil coated on a continuos paint line double baked and roll formed from enamelled corrosion Resistance Aluminium Alloy AA5050 (Al.Mg.) for higher strength and good Roll forming characteristics. Panel shall be clipped to baked enamelled Aluminium H-3 panel stringer of 39mm wide and 65mm deep x 0.95 mm thick in a standard length of 5mtrs made of double baked enamelled Aluminium Alloy AA5050 (Al.Mg.) white with cutouts to hold the panel in a module of 69mm centre to centre at a distance of 1mtr. The carrier shall be fixed to a suitable structure (As provided by the client) by means of rigid fixing details. Paint Finish: Aluminium panels shall be chromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer and Luxacote finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line. Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification. Mode of Measurements: Measurements shall be Length and Breadth of the facia without any deductions for any openings in claddings. Approved Makes - Hunter Douglas, COLT, CS (Construction Specialties (MR)
Supply & Installation of Aeroscreen 200 Plain / Perforated Sun Louvre system consisting of louver panel 200 mm wide manufactured from 0.7mm thick Aluminium-Alloy 3000 & 5000 series. The Louver Panels, if perforated shall have perforation of 2mm diameter with 5mm c/c apertures with 16% openness factor. The Louver shall be clipped to the support arm provided at the panel ends. The support arm shall be provided in between the length of the panels as per the requirement. The louver Fins shall be provided in variable module & lengths as per site requirements based on the wind load calculation and deflection, subject to a maximum length of 3.5 M, The supporting extrude tube shall be fixed at both ends with a fixed support which shall be mechanically fixed to a MS / aluminum tubular supporting structure (provided by the client). The louver panel shall be provided with a reinforcement arm of width 40 mm manufactured in alloy 6063 at distances 800-1200mm depending on the wind load. The louvers shall be secured and fixed to the support structure with HD proprietary fixing components comprising and a U profile of AL alloy 6063 T5 anodized, a fixation disk and fin suspension of Nylon and glass fiber . The spacing will be 450mm between two finsr Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification. NOTE - Substructure if required will be extra @ 1500/- to 2000/- per SQM Approved Makes - Hunter Douglas, Gorden, KNAUF or equivalent as approved. (MR)
Providing and fixing of Hunter Douglas® Single Aerobrise 200 fixed Louver system consists of ‘V’ shaped louver fin skins of manufactured out of 0.7mm thick Aluminium alloy AA3005, aluminium extruded assembly channel, press plate, nylon end caps on both sides Installation bracket and necessary screws. The factory assembled louver fins of 200mm as per the length shall be fixed mechanically to installation frame of Alu/MS provided by client with total projection of 116mm from the installation frame. The louver Fins shall be provided in 200mm module (Variable depend upon site requirement) in varying lengths as per site requirements subject to a maximum of 3 Mtrs. The installation frame shall be mechanically fixed to a structure (provided by client) 200mm distance from the panel edges and a c/c maximum distance of 1500mm in between subject to wind load. The erected installation frame shall be aligned within the tolerances of ± span/1000 of plumb line and level with a non-cumulative tolerance of a maximum of 2 mm. The louver skin shall be powder coated white suitable for exterior applications. Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification. NOTE - Substructure if required will be extra @ 1500/- to 2000/- per SQM Approved Makes - Hunter Douglas, Gorden, KNAUF or equivalent as approved. (MR)
Providing and fixing of Extruded Hollow Terracotta Louvers of dimensions 50 x 50 x 900mm on the building facade in horizontal direction. The louvers to be sleeved on hollow aluminium tubular profiles of Alloy 6063 T5/T6 which shall be capped at both ends with epdm gaskets and powdercoated aluminum L profiles / steel brackets (hot-dip galvanized shall be 80 microns) using screws (AISI 304 grade). The aluminium L profiles /steel brackets shall be fixed to primary vertical aluminium / steel framework / mullions with recommended bolts and nuts / screws (AISI 304 grade). The louvre system shall be designed to resist a wind pressure of 275 Kg/Sqm including all factors of safety. Approved Makes - Hunter Douglas, NBK, Moeding, Agrob Buchtal or equivalent as approved. (MR)
Supply and installation of Hunter Douglas Terracotta or equivalent as approved, pure mined clay tiles NBK TERRART-LIGHT 28 mm thickness Maximum Length: 1500 mm, Height: 500 mm. The tiles would be back ventilated, with self-draining open joint system. Tiles shall be double-leaf construction and have labyrinth top and bottom returns to prevent easy water access behind tiles. Water absorption to be in between 3% to 6% conforming to ISO 10545 - 3, average bending tensile strength of tile ≥ 18mm shall be ≥ 4500N conforming to ISO 10545-4, Freeze / Thaw resistance conforming to ISO 10545-12, Chemical resistance conforming to ISO 10545-13, Modulus of rupture shall be ≥16MPa conforming to ISO 10545-4, resistance to thermal shock shall be conforming to ISO 10545-9, Chemical resistance shall be no less than ULB level conforming to ISO 1054513, Resistance to stains shall be conforming to ISO 10545-14. The tiles shall be of NBK M6.02 Color and natural finish. The tolerance allowed in length is ± 1mm, height of front side is ± 2mm, height of back side is +2mm & - 3mm, thickness is ± 1.5mm, straightness of side is ± 2mm, vertical flatness is ± 2mm, diagonal flatness is ± 2mm as per ISO10545-2. Aluminum support system: The support system consists of extruded Anodized Aluminum vertical Full T-& Half T Tracks of Alloy 6063T5. The dimension of T Tracks would be 102X53X2 mm and maximum length of 5000 mm. A vertical black PVC gasket (max. length 5000 mm) would be slid on the T-Track between two tiles at vertical joint for proper alignment and extra support. The T-Track is to be mounted on extruded anodized Aluminum dead-load and wind load Wall Bracket of Alloy 6063T5. The dimension of it would be 100/120 X 70/90 X 50 X 4 mm. (MR)
The extruded Aluminum Clips of Alloy 6063T5 and thickness 2mm would be fastened on the pre-punched T Track on which the NBK Terracotta tiles are to be mounted. The vertical aluminum T-tracks with gaskets and tile clips shall serve to hold NBK Terracotta Pure Natural Clay tiles. The Clay tiles will be resting on a double bulb rubber gasket fixed to the Aluminum extrusion clips to enable the tiles to have expansion contraction movement. System is designed toaccommodate thermal movement. NBK Terracotta tiles shall be removable, without breakage or disruption to adjacent tiles. The clips shall be concealed. Fastening devices: stainless steel screws, anchor fasteners, nut & bolt are NOT in our scope and shall be provided by the installer. The basic design of the aluminum support system for TILES must be based upon the open ventilated facade principle. Building components must be designed to accommodate imposed loads from the aluminum support system and terra cotta tile. Building components must be designed so their deflection under imposed loading will not cause deflection of aluminum support system of exceed specified tolerances. Approved Makes - Hunter Douglas, NBK, Moeding, Agrob Buchta (MR)
LUXALON® Aluminium, Un-perforated, 300C Ceiling System: Providing and fixing of Luxalon® 300C un-perforated Aluminium panel ceiling manufactured by M/s. Hunter Douglas of approved colour consisting of panel 300mm wide x 30 mm deep x 0.7mm thick with bevel edge, panel length up to 6 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. The Panels shall about each other with a narrow V grove. Panel shall be clipped to a baked enamelled aluminium panel carrier of 41.5mm wide x 62mm deep x 0.95mm thick in standard length of 5 mtr made of doubled baked black enamelled aluminium alloy AA 5050 (Al. Mg) with cut outs to hold the panels in a module of 300mm closed at a distance 2.4 mtr. Panel carrier shall be suspended by means of G.I. suspension rod 4mm diameter and a Galvanised suspension spring clip at a distance of 1.7 mtr c/c Paint Finish: Aluminium panels shall be chromatised for maximum bond between metal and paint, enamelled twice under high temperature, one side with a full primer and finish coat the other side (inner side) with a primer coating and Skin Coat on a Continuous Paint Line. Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification. Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. Approved Makes - Hunter Douglas, Gorden, KNAUF or equivalent as approved. (MR)
Supply and fixing of “SELF SUPPORTED” SECRET FIX STANDING ROOFING/WALL CLADDING SYSTEM IN 0.9mm THICK AA 3004 ALUMINIUM ALLOY including accessories. Kingzip/Kingspan 65/400 Aluminium Self Support Standing Seam 65mm rib height and 400mm width of STRAIGHT / TAPERED / CURVED profiled panel as per the Roof Geometry, manufactured from Kingspan Aluminium AA 3004 as specified in BS EN1396:2007, minimum material thickness of 0.9mm with PVDF Finish. The material properties shall be as follows: Ultimate tensile strength: minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, Modulus of elasticity: 70,000 N/mm2. Sheets are to be laid in Single Length to meet the requirements of the building gemetry and fixed on Aluminium Clip and which is fixed with SS304 screws. Detail structural load calculation report to be provided by the manufacturer based on wind load as per IS 875 and screw pull out force. Sheets are to be laid to meet the requirements of the building geometry and fixed on Aluminum Halter. Halter to be fixed to the top hat/purlins with SS fasteners only. Ridges: Ridge details shall be completed by using Ridge closure, Ridge Filler. Eaves: Eave details shall be completed by using Eave Filler, Drip angle. Gable End: The gable end covered using Gable End Clip, Gable End Channel, and Tolerance clip. All installation is to be carried out by approved trained installer. The installation team shall be fully trained and approved by the manufacturer. Approved Make : Kingspan, Sanko, Interfal or equivalent as approved. (MR)
Supply and installation of polycarbonate multilayered system, a complete assembly of extrudedmultilayer UV protected polycarbonate panels incorporated into a complete system. Co-extrudedUV protected polycarbonate panel system of min 18 mm thick panel of 1200 mm (min.)width with angular daylighting concept in a complete system. All fixing accessories to ensure best performance for wind uplift, vibration ,oil canning and visual appearance. Panels shall be manufactured with vertical offset standing seam at both sides of thepanel. Panels shall have minimum seven layers with opaque and translucent clear combination as per required lux level. Panels shall be fixed on Purlin with snap on connectors with grip lock locking mechanismand will be secured on MS structure (will be paid Seperately) with 3 numbers self drillingscrews & trapezoid SS fasteners holding the base of the standing seam offering best stabilityhaving a pull-out load of min. 7000N (7KN) tested as perISO 6892:1998 and IS 1608: 2005. (MR)
Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakageon Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTMG 155. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9W/m2K as per EN ISO 10077-2:2018 Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends asrequired. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings.Trained andfactory authorized labor with supervision to complete the entire panel installation as perdrawing & direction of the engineering in charge.Color: As per Approval.
Providing and fixing Lead panel to flush door as per AERB norms at the core areas of the bulding structure such as radiology and OT department (MR)
Providing and fixing wall panelling with Lead as per AERB norms at the core areas of the building structure such as radiology and OT department (MR)
Providing and Installation Hospital Curtain Track made up of aluminium extrusion with white powder coated and all accessories, Hospital Curtains made up of Polyester fabric with netted top stiched in panels (st. Size 46"X84") along with water repellant, Antimicrobial and stain resistant properties. (MR)
Providing and fixing 152mm series Wall Guard with aluminium extrusion retainer, 2mm PVC Cover and rubber bumper sandwitched between aluminium retainer and PVC cover to absorb the shocks or force. Accessories: 2 end caps with every 3 meters and rubber bumper along with length. Colour: customised for MOQ 2000 meters (RMT-Running meter) (MR)
Providing and fixing upto 3.0m high FRAMELESS GLASS INTERNAL PARTITIONS for PARTITION with 12 mm clear Toughened / tempered glass as per elevation drawing with approved make of 316 grade V-series stainless steel fittings of DORMA, Germany / LISUS- SINGAPORE or approved equivalent with FHB-M12 bolts, M.S. vertical pipes (101.6mm OD)/ or size as shown in the enclosed drawings fixed with stainless steel screws or with fixing clips including necessary filling up gaps at junction, at top, and sides with required weather silicon sealant of grade 995 with backer rod shall be inserted between aluminium channel and glass as well as both inside and outside around the periphery to make the glazing air and water tight as shown the drawings. The stainless steel spider fittings shall have to be fixed to MS framework including making suitable holes in the glass before tempering process of glass, for installation complete as per design drawings. (MR)
The periphery shall have to be sealed both from inside and outside with silicon weather sealant grade 995 to make the glazing water/ airtight. The sealing of glass to connector pipes with stainless steel fixtures as detailed in drawings. Silicon sealant grade shall be "Dow corning USA" or "WACKER - Germany" or equivalent as per the design requirement.The partition shall be aligned for the entire height and for the entire length by laser beam equipment to ensure 100 percent 'X' axis and 'Y' axis alignment. The glass joints must be properly sealed with weather silicon to make the joint water tight/ air tight. (MS work shall be paid for separately under respective head 7.01).
Providing and fixing Automatic bi-parting sliding door operator of approved make as DORMA, Germany (ES-200 –EASY) or KABA Switzerland, Portalp or equivalent with 10mm thick toughened clear glass shutters, modular design, including internal aluminium cover the track profile should be separate from main profile for better sound insulation and vibration With automatic Operator, Microprocessor control panel. self-learning, reversing when obstruction is encountered. Microprocessor- controlled control unit with adjustable parameters for opening and closing speed, hold-open time and opening and closing force. Class of protection IP 20. The system shall have constant power supply 210V, 50/60Hz, for various opening sizes all complete as per design and instructions of Engineer-in-Charge. (MR)
Providing and placing WIlliams Architectural/Gainsborough/Herman millar Make Back storage unit of size 1800mm L x 450mm D x 750mm H. Storage body is made of 18mm thick pre laminated partical Board conforming to IS : 12823. The back of the unit is made from 9mm prelaminated board. All the exposed edges are with 2mm PVC egde Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding. The top, side and hinged shutters are sealed with 2mm thick PVC edge banding. The units are assembled by knock down fittings such as Minifix & Dowels. (MR)
Providing and fixing 600 mm deep modular kitchen storage cabinet, over head cabinet 850mm high rested at floor, made of 19mm thick prelaminated MDF board on top, bottom, sides, partitions, shelves, post formed edge for shutters, 12 mm thick prelaminated MDF board for sides & back of drawers, 6mm thick prelaminated MDF board at back of cabinet & bottom drawers, PVC edge binding on exposed edges of boards , including drain board clip on hinges, ball catchers, handles/knobs, powder coated sliding channel, multipurpose lock , stainless steel accessories, Chimney and exaust Duct, Drain board, Sink etc. complete as per design and drawing. All hardware's to be Brushed Stainless Steel finish. ( one Complete job work to be paid for ) excluding cost of top granite of approved make Hettich, Hafele, Hacker) (MR)
Providing and fixing 600 mm deep modular kitchen storage cabinet, over head cabinet 850mm high rested at floor, made of 19mm thick prelaminated MDF board on top, bottom, sides, partitions, shelves, post formed edge for shutters, 12 mm thick prelaminated MDF board for sides & back of drawers, 6mm thick prelaminated MDF board at back of cabinet & bottom drawers, PVC edge binding on exposed edges of boards , including drain board clip on hinges, ball catchers, handles/knobs, powder coated sliding channel, multipurpose lock , stainless steel accessories etc. complete as per design and drawing. All hardware's to be Brushed Stainless Steel finish. ( one Complete job work to be paid for ) excluding cost of top granite of approved make Hettich, Hafele, Hacker) (MR)
Extra and above item no.1 : Providing & fixing oval ready-made imported bowls in acrylic solid surface in glacier white color, manufactured under ISO 19712, with minimum bowl size of 571 x 418 x178 mm of approved make. The bowls should be fixed seamlessly under-the- counter as directed by Engineer-in-charge. (REF. model DuPont CORIAN Calm 815 dimensions 571X520X418) (MR)
Supply, Installation, Testing & Commissioning of SOMFY’s O&O Boom Barriers- Model New Up & Down 6 or approved equivalent make. Length of Boom : upto 6 M Duty Cycle: Intensive Opening- Closing Time : 2.5-4 seconds(Adjustable) With –in Built crash protection feature manual over-ride, Integration with Smart card and proximity reader, Along with push button for opening and closing of Barrier With Safety rubber at bottom. Photocell included for auto closing. (MR)
Supply & Installation of Skylight with glazed units of size as per design/drawing and consisting of laminated glass comprising with 6 mm thick Blue toughened solar control float glass ( SGG COOL LITE Blue ISLE ST 708 or equivalent) on outer face + 1.52 mm PVB lamination + 6 mm thick toughened clear float glass on the lower face of approved shade with characteristics as per specification) fixed in precise size on the outer face of mullion / transom as per direction of the Engineer-in-Charge for TRUSS MEMBER SHAPED SKY LIGHT including cost of sealants, brackets, fasteners, screws, sleeves, spacer tap backer rods, bolts, gasket, fixtures, double stage scaffolding, sales tax/VAT, excise duty etc. complete in all respect.Silicon sealant grade shall be "Dow corning USA" or "WACKER - Germany" or equivalent as per the design requirement. Note: Supporting MS structure and mullion/ transom shall be paid separately (MR)
Drilling and grouting for TMT bars
25 mm dia with (NSOR)
20 mm dia with (NSOR)
16 mm dia with (NSOR)
12 mm dia with (NSOR)
10 mm dia with (NSOR)
Polysulphide (NSOR)
GP2 Grauting (NSOR)
Making sleeves and cut-outs in RCC wall, beams and slabs of any shape and size by way of core cutting as per requirement of Architect/PMC for various services for cables/pipes for plumbing/HVAC/ Electrical and finishing the same etc. complete. A). Upto 100 mm dia. (NSOR)
Making sleeves and cut-outs in RCC wall, beams and slabs of any shape and size by way of core cutting as per requirement of Architect/PMC for various services for cables/pipes for plumbing/HVAC/ Electrical and finishing the same etc. complete. A). From 100mm to 150 mm dia. (NSOR)
Making sleeves and cut-outs in RCC wall, beams and slabs of any shape and size by way of core cutting as per requirement of Architect/PMC for various services for cables/pipes for plumbing/HVAC/ Electrical and finishing the same etc. complete. A). Above 150 to 250 mm dia. (NSOR)
Piling Work
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (DSR 20.2)
450 mm dia piles (DSR 20.2.1)
600 mm dia piles (DSR 20.2.3)
Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Upto plinth level (DSR 5.22)
Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6).
SITE DEVELOPMENT WORK
Earth Work
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (DSR 2.6)
All Kinds of soil (DSR 2.6.1).
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (DSR 2.7)
Ordinary rock (DSR 2.7.1).
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (DSR 2.10)
All Kinds of soil (DSR 2.10.1).
Pipes, cables etc. not exceeding 80 mm dia. (2.10.1.1)
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (DSR 2.10.1.2).
Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia (DSR 2.10.1.3).
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR 2.25).
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26)
All Kinds of soil (DSR 2.26.1)
Ordinary or hard rock (DSR 2.26.2)
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. (DSR 4.1)
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (DSR 4.1.8).
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (DSR 4.12).
R.C.C WORK
Centering and shuttering including strutting, propping etc. and removal of form for all heights : (DSR 5.9).
Foundations, footings, bases of columns etc. for mass concrete. (DSR 5.9.1).
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2).
Suspended floors, roofs, landings, balconies and access platform. (DSR 5.9.3).
Lintels, beams, plinth beams, girders, bressumers and cantilevers. (DSR 5.9.5).
Stairs, (excluding landings) except spiral - staircases. (DSR 5.9.7).
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 Metre or part thereof (Plan area to be measured). (DSR 5.11)
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) (DSR 5.11.1).
Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Upto plinth level (DSR 5.22).
Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)..
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR 5.22A)
Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22A 6).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 Kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). (DSR 5.33)
All work upto plinth level (DSR 5.33.1)
All work from plinth level upto floor V level. (DSR 5.33.2).
CLADDING WORK
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 8.31)
WOOD WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). (DSR 9.10)
Sal Wood (DSR 9.1.2)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.20)
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1)
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96)
300x16 mm (DSR 9.96.1)
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.100)
125 mm (DSR 9.100.1)
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101)
Twin rubber stopper (DSR 9.101.2)
STEEL WORK
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete (DSR 10.2)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25)
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2)
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26)
M.S. tube (DSR 10.26.1)
FLOORING WORK
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 Kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.5)
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (DSR 11.6)
18 mm thick (DSR 11.6.1)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26)
25 mm thick (DSR 11.26.1)
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (DSR 11.040)
FINISHING WORK
12 mm cement plaster of mix : (13.1)
1:4 (1 cement: 4 fine sand) (DSR 13.1.1)
6 mm cement plaster to ceiling of mix : (DSR 13.16)
1:3 (1 Cement : 3 fine sand) (DSR 13.16.1)
Neat cement punning. (DSR 13.18)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR 13.21).
White washing with lime to give an even shade : (DSR 13.37)
New work (three or more coats) (DSR 13.37.1)
ROAD WORK + Parking
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 Metre. (DSR 16.1)
Supplying and stacking at site. (DSR 16.3)
Good Earth (DSR 16.3.9)
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : (DSR 16.30)
On W.B.M. @ 0.75 Kg / sqm (DSR 16.30.1)
2 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). (DSR 16.32)
With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt (DSR 16.32.1)
Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. (DSR 16.40)
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge. (DSR 16.54)
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity. (DSR 16.54.2)
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR 16.75)
Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete. (DSR 16.44)
Providing and fixing in position pre-moulded joint filler in expansion joints. (DSR 16.45)
Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR 16.46)
Using grade 'A' sealing compound. (DSR 16.46.1)
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete. (DSR 16.47)
New work (Two or more coats) (DSR 16.47.1)
Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete. (DSR 16.49)
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type -IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D- 4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer--in-charge. (DSR 16.59)
Mandatory/ Regulatory sign boards of 900 mm diameter with support length of 3750 mm (DSR 16.59.1)
Cautionary /warning sign boards of equilateral triangular shape having Each side of 900 mm with support length of 3650 mm (DSR 16.59.2)
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). (DSR 16.60)
Overhead informatory road signage (DSR 16.60.1)
Providing Retro-reflective regulatory sign board of size 900 mm dia Metre made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in charge. (DSR 16.61)
Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. (DSR 16.62)
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). (DSR 16.69)
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78)
With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 (DSR 16.78.1)
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge (DSR 16.80)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper mbedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91)
60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1)
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. (DSR 16.93)
DRAINAGE
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. Complete (DSR 19.36)
450 mm dia RCC pipes. (DSR 16.36.1)
600 mm dia RCC pipes. (DSR 19.36.2)
WATER PROOFING
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (DSR 22.1).
(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Using rough Kota stone (DSR 22.1.1).
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : (DSR 22.2)
Using rough Kota stone (DSR 22.2.1)..
HORTICULTURE AND LAND SCAPING
Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment). (DSR 2.2)
Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). (DSR 2.3)
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : (DSR 2.4)
Screened through sieve of I.S. designation 20 mm (DSR 2.4.1)
Fine dressing of the ground. (DSR 2.7)
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). (DSR 2.8)
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge (DSR 2.9)
In rows 5 cm apart in both directions (DSR 2.10.1)
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of Each layer, dressing etc., lead upto 50 Metre and lift upto 1.5 m complete as per direction of Officer-in-charge. (DSR 2.28)
Supply and stacking of plant Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm., in Earthen potls of size 20 cm as per direction of the officer-in-charge. (DSR 8.52)
Supply and stacking of plant Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. (DSR 8.70)
Callistemon lanceolatus of plants height 150-165 cm. in big poly bags of plants size 25 cm (DSR 10269)
Cyprus Golden Conical Shape 150 to 165 cm ht. plant, with fresh and healthy Golden colour foliage in 35cm Cement Pot (DSR 10198)
Palms
Bismarkia Palm 115 to 180 cm ht. plant, well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot (DSR 10191)
Cycus circinallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot (DSR 10193)
Cyprus Golden 30 to 45 cm ht. plant well developed good Golden colour foliage, Conial Shape in 25 cm Earthen Pots (DSR 10196
Verigated Plants
Providing and Displaying Furcaria Variegated plant hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge. (DSR 5.32)
Shurbs
Supply and stacking of plant Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm (DSR 10349)
Bamboo
Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type plant well developed in 50 cm Cement Pot (DSR 10189)
Topairies
Ficus black vivion piller Topairy (sylinder type) well developed with fresh & healthy 180 to 210 cm ht in 40 cm Cement Pot (DSR 10200)
Ficus Nuda Topairy well developed with fresh & healthy 5 to 6 big ball specific size and shape 180to 210cm ht in 40 cm Cement Pot (DSR 10202)
Ficus Retusa Topairy well developed with fresh & healthy 5 to 6 big ball specific size and shape 180 to 210cm ht in 40 cm Cement Pot (DSR 10204)
Ficus resnold piller type Topairy well developed with fresh & healthy 210 to 240 cm ht in 40 cm Cement Pot (DSR 10206)
Ficus Starlight with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht. plant, specimen bushy plant,in 35 cm Cement Pot (DSR 10208)
Providing and Displaying Golden Bottle brush Topairy well developed with fresh & healthy foliage 5 to 6 big ball 115 to 180 cm ht in 40 cm Cement Pot as per direction of the officer-incharge. (DSR 5.33)
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) (DSR 2.57
Tree Plant (DSR 2.57.1)
Shrubs Plant (DSR 2.57.2)
Internal Sanitary & Plumbing
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (DSR 17.78)
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (DSR 17.2)
W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1)
W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1).
Providing and fixing health faucet with 8mm ida, 1.2 meter long flexible tube & wall hook. (RA-1)
Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. (DSR 17.79)
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : (DSR 17.5)
Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern (DSR 17.5.2)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7)
White Vitreous China Flat back wash basin size 550 x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4)
Providing and fixing Counter Top wash basin with C.I. brackets, basin mixer, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (RA-2)
Providing and fixing single lever basin mixer without popup waste system with 450mm long Braided Hoses (RA-10)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : (DSR 17.32)
Rectangular shape 1500x450 mm (DSR 17.32.4)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (17.22A)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.10)
Kitchen sink with drain board (DSR 17.10.1)
510x1040 mm bowl depth 225 mm (DSR 17.10.1.2)
Providing and fixing Single Lever Sink Mixer with Swinging Spout(Table Mounted) with 450 mm long Braided (RA-3)
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : (DSR 17.11)
Size 450x300x150 mm (DSR 17.11.1)
Providing and fixing toilet paper holder : (DSR 17.34)
C.P. brass (DSR 17.34.1)
Providing and fixing Single Towel Rail 600mm long stainless steel (RA-4)
Providing and fixing Single Towel ring stainless steel (RA-5)
Providing and fixing Over Head Shower Rose 180mm dia round shape single flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit cleaning system (RA-6)
Providing and fixing Single Lever High Flow Bath & Shower Mixer (Concealed Body) Wall mounted model with Botton Spout (Composite Cone Piece Body). (RA-7)
Providing and fixing soap dish holder (RA-8)
Providing and fixing soap dispensor (RA-9)
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : (DSR 17.37)
For 100 mm dia pipe (DSR 17.37.1)
For 75 mm dia pipe (DSR 17.37.2)
For 150 mm dia pipe ( DDSSR NSR)
Providing and fixing soil, waste and vent pipes : (DSR 17.35)
100 mm dia (DSR 17.35.1)
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 (DSR 17.35.1.3)
75 mm dia (DSR 17.35.2)
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 (DSR 17.35.2.3)
150 mm dia
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 (RA-13)
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe (DSR 17.57A)
100mm dia (DSR 17.57a-1)
SS 304 grade coupling with EPDM rubber gasket
75mm dia (DSR 17.57a-2)
SS 304 grade coupling with EPDM rubber gasket
150mm dia
SS 304 grade coupling with EPDM rubber gasket (RA-14)
Providing and fixing terminal guard : (DSR 17.56)
100mm dia (DSR 17.56.1)
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 (DSR 17.56.1.3)
75mm dia (DSR 17.56.2)
Sand cast iron S&S as per IS - 3989 (DSR 17.56.2.2)
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. (DSR 17.43)
100x100x100 mm (DSR 17.43.1)
Sand cast iron S&S as per IS - 3989 (DSR 17.43.1.2)
75x75x75mm (DSR 17.43.2)
Sand cast iron S&S as per IS - 3989 (DSR 17.43.2.2)
Providing and fixing single equal plain junction of required degree : (DSR 17.44)
100x100x100 mm (DSR 17.44.1)
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 (DSR 17.44.1.3)
75x75x75mm (DSR 17.44.2)
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 (DSR 17.44.2.3)
150x150x150mm (NSR1 NSR)
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing plain bend of required degree. (DSR 17.39)
100 mm dia (DSR 17.39.1)
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 (DSR 17.39.1.3)
75 mm dia (DSR 17.39.2)
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 (DSR 17.39.2.3)
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. (DSR 17.38)
100 mm dia (DSR 17.38.1)
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 (DSR 17.38.1.3)
75mm dia (DSR 17.38.2)
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905(DSR 17.38.2.3)
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : (DSR 17.60)
100 mm inlet and 100 mm outlet (DSR 17.60.1)
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 (DSR 17.60.1.3)
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28)
Semi rigid pipe (DSR 17.28.1)
32 mm dia (DSR 17.28.1.1)
Flaxible (DSR 17.28.2)
32 mm dia (DSR 17.28.2.2)
WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (DSR 18.7)
15 mm nominal outer dia Pipes (DSR 18.7.1)
20 mm nominal outer dia Pipes (DSR 18.7.2)
25 mm nominal outer dia Pipes (DSR 18.7.3)
32 mm nominal outer dia Pipes (DSR 18.7.4)
40 mm nominal outer dia Pipes (DSR 18.7.5)
50 mm nominal outer dia Pipes (DSR 18.7.6)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (DSR 18.9)
62.50 mm nominal inner dia Pipes (DSR 18.9.7)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (DSR 18.8)
15 mm nominal outer dia Pipes (DSR 18.8.1)
20 mm nominal outer dia Pipes (DSR 18.8.2)
25 mm nominal outer dia Pipes (DSR 18.8.3)
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13)
25 to 40 mm nominal bore (DSR 18.13.1)
50 to 80 mm nominal bore (DSR 18.13.2)
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17)
25 mm nominal bore (DSR 18.17.1)
32 mm nominal bore (DSR 18.17.2)
40mm nominal bore (DSR 18.17.3)
50 mm nominal bore (DSR 18.17.4)
65 mm nominal bore (DSR 18.17.5)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (DSR 18.18)
15 mm nominal bore (DSR 18.18.1)
20 mm nominal bore (DSR 18.18.2)
25 mm nominal bore (DSR 18.18.3)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (DSR 18.53)
15mm nominal bore (DSR 18.53.1)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : (DSR 18.49)
15mm nominal bore (DSR 18.53.1).
Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21)
45 cm length (DSR 18.21.2)
15 mm nominal bore (DSR 18.21.2.1)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR 18.48)
Solar water Heater
6000 lpd Sun Flair Water heating system including 6000liter syntax tank with ms stand 1 inch Cpvc pipe with fitting charges with accessories. (DSR110NSR)
SUB HEAD -B: EXTERNAL DRAINAGE
EXTERNAL DRAINAGE
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6)
150 mm dia. Pipe ( DSR19 a)
200 mm dia. Pipe (RA-16)
250 mm dia. Pipe (DSR110b)
300 mm dia. Pipe (DSR112c)
450 mm dia. Pipe (DSR113c)
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : (DSR 19.7)
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : (DSR 19.7.1)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.7.1.1)
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : (DSR 19.7.2)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.7.2.1)
Extra for depth for manholes : (DSR 19.8)
Size 90x80 cm (DSR 19.8.1)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.8.1.1)
Size 120x90 cm (DSR 19.8.2)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.8.2.1)
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : (DSR 19.9)
0.91 m deep with SFRC cover and frame (heavy duty, HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : (DSR 19.9.1)
With Sewer bricks conforming to IS : 4885 (DSR 19.9.1.1)
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m (DSR 19.10)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.10.1)
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : (DSR 19.11)
1.68 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : (DSR 19.11.1)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.11.1.1)
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : (DSR 19.12)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.12.1)
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4coarse sand) inside cement plaster 12 mm thick with cement mortar1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : (DSR 19.13)
2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.13.1)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.13.1.1)
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m (DSR 19.14)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.14.1)
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : (DSR 19.28)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSr 19.28.1)
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : (DSr 19.29)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.29.1)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. ( DSR 2.6)
All kind of soil (DSR 2.6.1)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. (DSR 2.7)
Hard rock (requiring blasting) (DSR 2.7.2)
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26).
All kinds of soil (DSR 2.26.1)
Ordinary or hard rock (DSR 2.26.2).
Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). (DSR 2.17)
Depth not exceeding 1.5 m (DSR 2.17.1)
Depth exceeding 1.5 m but not exceeding 3 m (DSR 2.17.2)
Depth exceeding 3.0 m but not exceeding 4.5 m (DSR 2.17.3)
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : (DSR 19.15)
With 20x20 mm square bar (DSR 19.15.1)
EXTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (DSR 18.9)
40 mm nominal outer dia Pipes (DSR 18.9.5)
50 mm nominal inner dia Pipes (DSR 18.9.6)
65 mm nominal inner dia Pipes (DSR 18.9.7)
75 mm nominal inner dia Pipes (DSR 18.9.8)
100 mm nominal inner dia Pipes (DSR 18.9.9)
Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : (DSR 18.17)
40 mm nominal bore (DSR 18.17.3)
50 mm nominal bore (DSR 18.17.4).
65 mm nominal bore (DSR 18.17.5).
80 mm nominal bore (DSR 18.17.6)
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31)
100 mm diameter (DSR 18.31.1)
Class II (DSR 18.31.1.1)
SUB HEAD -D: STP
STP plant of 450 Cu.m capacity (MR)
STP Sewage Treatment Plant Supply ,installation, Testing comissioning of MBBR based STP plant of 450 Cu.m capacity. A : Nature of effluent - Domestic Sewage from toilet and kitchen shall be discharged into the STP. Design to take consideration of same. INLET EFFLUENT CHARACTERSTICS: pH - 6.5 – 8.5, BOD - 250-350 Mg/L, S. Solids - 200-400 Mg/L, COD - 450-600 Mg/L, Oil & Grease - < 50 Mg / L . DISCHARGE EFFLUENT CHARACTERSTICS AFTER TREATMENT : pH - 6.0 – 8.5, BOD Less than 5 Mg/L, S. Solids - NIL, COD - Less than 20 Mg/L, Oil & Grease - Less than 5 Mg / L, e-coil- nill. Sewage treatment plant shall comprise the following tanks in civil construction ( to be paid as per Civil BOQ Items ) : Screen Chamber, Oil & Grease Trap chamber , Sewage equalization tank/sump , MBBR Reactors , Tube Settler Tank, Sludge Holding Tank, Filter Feed Tank , Treated water Tank/s , Drain Sump , Drain Channel , Foundations for the equipments . Supply, installation, testing & commissioning of 2 Nos Stainless Steel Perforated,
b : Supply, installation, testing & commissioning of non clogging type pumps having CI casing & CI impeller complete with all accessories, motor of required capacity. pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty: b-1: Raw Sewage Transfer Pumps (3 Nos. - 2 working + 1 standby) Flow rate (each) = 11 cum/hr , Head = 8- 10 Mts , Type = Submersible, (Solid handling size for this pump shall be 32 mm)., ( Make - CRI/Eqv. ). Cost shall be inclusive of PVC flexible Hose pipe (for piping submeged in effluent) with GI (Heavy) piping . Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section of MSEP shall be made by the STP contractor.
c : Air diffusion system shall include the following c-1: Non clog, Self Cleaning type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per Metre water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top. Note: Air dispersion system shall be provided for Sewage Sump, aeration tank and Sludge Holding Tank. Fine Bubble Diffusers in Each MBBR Tank ,Imported Fine bubble with silicon/ EPDM membrane in MBBR tank. Size 63 mm OD x 1000 mm long . Coarse Bubble Diffusers in Eq. tank and in sludge tank ,Coarse bubble diffusers in EQT and sludge Tank. Make: MM Aqua / Equivelent
c-2: Supply, Installation, testing & commissioning of Air diffuser system with 3 nos. twin lobe -type air blower of capacity 200 Cum/hr at the pressure of 0.50 Kg/cm2 each complete with valves & air distribution grid, flexible pipie etc. complete as required. (One set consists of 3 nos. of blower). Make: Everest/ Equivelent
c-3: Supply Installation, testing & commissioning of FAB & Tube deck media in aeration and tube settling tank respectively. Make: MM Aqua / Equivelent
d-1 : TERTIARY TREATMENT FILTER FEED PUMPS :Supply, Installation, testing & commissioning of horizontal centrifugal pumps for filtration. The pumps shall be made of CI casing, bronze Impellar, SS shaft & sleeve, Mechanical Seal are connected to a TEFC induction motor mounted on a common channel base frame with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for 415+10% V, three/single Phase, 50 cycles AC power supply,all panels should be MCB isolation S/D Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump, including all necessary piping, valves and other accessories and concrete foundation complete as required. Capacity : 25 M3/hr @ Discharge Head 30 mtr head Quantity : 2 Nos.(1 working + 1 standby) Make:Kirloskar or equivalent
d-2 : MULTIGRADE SAND FILTER Supply, installation, testing & commissioning of vertical self supporting Multi Grade Sand Filter (MGF) fabricated from MSEP complete with pressure gauges at inlet & outlet, sample cock, multiport valves, PVC face piping with all accessories, with initial charge of filter media for multi media filter with multi grade quartz sand & supporting media,with testing & commissioning complete. Capacity : 25 M3/hr Filtration rate : 18 M3/Sq.M./hr Max. operating pressure : 5 Kg/sq.cm Test pressure : 10 Kg/Sq.cm diameter : 1400 mm Make: Pentair / Equivelent
d-3 : ACTIVATED CARBON FILTER : Supply, installation, testing & commissioning of vertical self supporting Activated Carbon Filter (ACF) fabricated from MSEP, complete with pressure gauges at inlet & outlet, sample cock, multiport valves, PVC face piping with all accessories, with initial charge of filter media for multi media filter with multi grade quartz sand & supporting media,with testing & commissioning complete. Capacity : 25 M3/hr Filtration rate : 15 M3/Sq.M./hr Max. operating pressure : 5 Kg/sq.cm Test pressure : 10 Kg/Sq.cm diameter : 1400 mm Make: Pentair / Equivalent
e : Supply, Installation, Testing & Commissioning of dosing system consisting of one HDPE tank of 200 liters capacity with a positive displacement diphragm dosing pump having variable flowrate of 0-6 LPH.
f : SLUDGE HANDLING ARRANGEMENT f-1: SLUDGE RECIRCULATION PUMP: Supply, Installation, Testing & Commissioning of Sludge Re-circular pumps. The pumps shall have CI casing & Impeller & SS shaft & sleeve with mechanical rotary shaft seal connected by a flexible tier type coupling to TEFC induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for 415+ % V, three/single phase, 50 Hz, AC power supply,all panels should be MCB isolation S/D Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump, including all necessary piping, valves and other accessories and concrete foundation complete as required. (2 Working + 0 Stand by) Capacity : 5 M3/hr @ Discharge Head 8 mtr head Make:Kirloskar or equivalent
f : SLUDGE HANDLING ARRANGEMENT f-2: SCREW PUMP Supply, Installation, testing & commissioning of screw pump for the disposal of sludge to Filter Press. The pumps shall have CI casing, bronze Impeller & SS shaft & sleeve with mechanical rotary shaft seal connected by a flexible tier type coupling to TEFC induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for 415+ % V, three/single phase, 50 Hz, AC power supply,all panels should be MCB isolation S/D Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump, including all necessary piping, valves and other accessories and concrete foundation complete as required. (1 Working + 1 Stand by). Capacity : 5 M3/hr @ Discharge Head 50 mtr head Make:Roto/Eqv.
f : SLUDGE HANDLING ARRANGEMENT f3: FILTER PRESS Supply, Installation, testing & commissioning of hydraulic type filter press for dewatering of sludge along with poly dosing system complete arrangement. Make:Pharmatech/Eqv.
g : ULTRA VIOLET SYSTEM Supply, Installation, testing & commissioning of ultra violet system to for dis infection with complete arrangement. Flow : 25 m3/hr Make:Alfaa/Eqv.
h : Providing and fixing all piping (as described below) and isolation control valves for making the system complete. GI : Submerged air piping MS (Heavy) : Interconnecting pipe line after delivery header of pump/ filter.
C : Operation and maintinance of above STP for a period of One year including supplying of required operator/ consumables. Payment will be released monthly on prorata bases.
HYDROPNEUMATIC PUMP (2Working & One Stand By ) Product Type: VERTICAL MULTISTAGE PUMP Product Configuration ,Pump Classification: Hydro-Pneumatic Booster System, Pump Construction: Pump With Motor, Parallel Pumping System, Numbers of Pump in System: 3 Pump,
Operaion & Maintenence Service Charge
STP plant of 300 Cu.m capacity
STP Sewage Treatment Plant Supply ,installation, Testing comissioning of MBBR based STP plant of 370 Cu.m capacity. A : Nature of effluent - Domestic Sewage from toilet and kitchen shall be discharged into the STP. Design to take consideration of same. INLET EFFLUENT CHARACTERSTICS: pH - 6.5 – 8.5, BOD - 250-350 Mg/L, S. Solids - 200-400 Mg/L, COD - 450-600 Mg/L, Oil & Grease - < 50 Mg / L . DISCHARGE EFFLUENT CHARACTERSTICS AFTER TREATMENT : pH - 6.0 – 8.5, BOD Less than 5 Mg/L, S. Solids - NIL, COD - Less than 20 Mg/L, Oil & Grease - Less than 5 Mg / L, e-coil- nill. Sewage treatment plant shall comprise the following tanks in civil construction ( to be paid as per Civil BOQ Items ) : Screen Chamber, Oil & Grease Trap chamber , Sewage equalization tank/sump , MBBR Reactors , Tube Settler Tank, Sludge Holding Tank, Filter Feed Tank , Treated water Tank/s , Drain Sump , Drain Channel , Foundations for the equipments . Supply, installation, testing & commissioning of 2 Nos Stainless Steel Perforated, (D112SR 1)
b : Supply, installation, testing & commissioning of non clogging type pumps having CI casing & CI impeller complete with all accessories, motor of required capacity. pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty: b-1: Raw Sewage Transfer Pumps (3 Nos. - 2 working + 1 standby) Flow rate (each) = 8 cum/hr , Head = 8- 10 Mts , Type = Submersible, (Solid handling size for this pump shall be 32 mm)., ( Make - CRI/Eqv. ). Cost shall be inclusive of PVC flexible Hose pipe (for piping submeged in effluent) with GI (Heavy) piping . Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section of MSEP shall be made by the STP contractor. (NS-21. 2)
NS-21 c : Air diffusion system shall include the following c-1: Non clog, Self Cleaning type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per Metre water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top. Note:Air dispersion system shall be provided for Sewage Sump, aeration tank and Sludge Holding Tank. Fine Bubble Diffusers in Each MBBR Tank ,Imported Fine bubble with silicon/ EPDM membrane in MBBR tank. Size 63 mm OD x 1000 mm long . Coarse Bubble Diffusers in Eq. tank and in sludge tank ,Coarse bubble diffusers in EQT and sludge Tank. Make: MM Aqua / Equivelent (NS211 2)
NS-21 c-2: Supply, Installation, testing & commissioning of Air diffuser system with 3 nos. twin lobe -type air blower of capacity 160 Cum/hr at the pressure of 0.50 Kg/cm2 each complete with valves & air distribution grid, flexible pipie etc. complete as required. (One set consists of 3 nos. of blower). Make: Everest/ Equivelent (3)
NS-21 c-3: Supply Installation, testing & commissioning of FAB & Tube deck media in aeration and tube settling tank respectively. Make: MM Aqua / Equivelent (4)
NS-21 d-1 : TERTIARY TREATMENT FILTER FEED PUMPS :Supply, Installation, testing & commissioning of horizontal centrifugal pumps for filtration. The pumps shall be made of CI casing, bronze Impellar, SS shaft & sleeve, Mechanical Seal are connected to a TEFC induction motor mounted on a common channel base frame with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for 415+10% V, three/single Phase, 50 cycles AC power supply,all panels should be MCB isolation S/D Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump, including all necessary piping, valves and other accessories and concrete foundation complete as required. Capacity : 20 M3/hr @ Discharge Head 30 mtr head Quantity : 2 Nos.(1 working + 1 standby) Make:Kirloskar or equivalent (5)
NS-21 d-2 : MULTIGRADE SAND FILTER Supply, installation, testing & commissioning of vertical self supporting Multi Grade Sand Filter (MGF) fabricated from MSEP complete with pressure gauges at inlet & outlet, sample cock, multiport valves, PVC face piping with all accessories, with initial charge of filter media for multi media filter with multi grade quartz sand & supporting media,with testing & commissioning complete. Capacity : 20M3/hr Filtration rate : 18 M3/Sq.M./hr Max. operating pressure : 5 Kg/sq.cm Test pressure : 10 Kg/Sq.cm diameter : 1200 mm Make: Pentair / Equivelent (6)
NS-21 d-3 : ACTIVATED CARBON FILTER : Supply, installation, testing & commissioning of vertical self supporting Activated Carbon Filter (ACF) fabricated from MSEP, complete with pressure gauges at inlet & outlet, sample cock, multiport valves, PVC face piping with all accessories, with initial charge of filter media for multi media filter with multi grade quartz sand & supporting media,with testing & commissioning complete. Capacity : 25 M3/hr Filtration rate : 15 M3/Sq.M./hr Max. operating pressure : 5 Kg/sq.cm Test pressure : 10 Kg/Sq.cm diameter : 1200 mm Make: Pentair / Equivalent (7)
NS-21 e : Supply, Installation, Testing & Commissioning of dosing system consisting of one HDPE tank of 200 liters capacity with a positive displacement diphragm dosing pump having variable flowrate of 0-6 LPH. (8)
NS-21 f : SLUDGE HANDLING ARRANGEMENT f-1: SLUDGE RECIRCULATION PUMP: Supply, Installation, Testing & Commissioning of Sludge Re-circular pumps. The pumps shall have CI casing & Impeller & SS shaft & sleeve with mechanical rotary shaft seal connected by a flexible tier type coupling to TEFC induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for 415+ % V, three/single phase, 50 Hz, AC power supply,all panels should be MCB isolation S/D Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump, including all necessary piping, valves and other accessories and concrete foundation complete as required. (2 Working + 0 Stand by) Capacity : 3 M3/hr @ Discharge Head 8 mtr head Make:Kirloskar or equivalent (9)
NS-21 f : SLUDGE HANDLING ARRANGEMENT f-2: SCREW PUMP Supply, Installation, testing & commissioning of screw pump for the disposal of sludge to Filter Press. The pumps shall have CI casing, bronze Impeller & SS shaft & sleeve with mechanical rotary shaft seal connected by a flexible tier type coupling to TEFC induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for 415+ % V, three/single phase, 50 Hz, AC power supply,all panels should be MCB isolation S/D Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump, including all necessary piping, valves and other accessories and concrete foundation complete as required. (1 Working + 1 Stand by). Capacity : 3 M3/hr @ Discharge Head 50 mtr head Make:Roto/Eqv. (10)
NS-21 f : SLUDGE HANDLING ARRANGEMENT f3: FILTER PRESS Supply, Installation, testing & commissioning of hydraulic type filter press for dewatering of sludge along with poly dosing system complete arrangement. Make:Pharmatech/Eqv. (11)
NS-21 g : ULTRA VIOLET SYSTEM Supply, Installation, testing & commissioning of ultra violet system to for dis infection with complete arrangement. Flow : 20 m3/hr Make:Alfaa/Eqv. (12)
NS-21 h : Providing and fixing all piping (as described below) and isolation control valves for making the system complete. GI : Submerged air piping MS (Heavy) : Interconnecting pipe line after delivery header of pump/ filter. (13)
NS-21 C : Operation and maintinance of above STP for a period of One year including supplying of required operator/ consumables. Payment will be released monthly on prorata bases. (15)
NS-22 HYDROPNEUMATIC PUMP (2Working & One Stand By ) Product Type: VERTICAL MULTISTAGE PUMP Product Configuration ,Pump Classification: Hydro-Pneumatic Booster System, Pump Construction: Pump With Motor, Parallel Pumping System, Numbers of Pump in System: 3 Pump, (16)
Operaion & Maintenence Service Charge
SUB HEAD-E:WATER TREATMENT PLANT
PUMPING AND PIPING
FILTER FEED PUMPS
Supply, Installation, testing and commissioning of pumping system comprising the following:
Horizontal centrifugal monoblock pumps with mechanical seal, CI casing, CI impeller and SS 304 shaft , 2900 rpm connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia Pressure Gauge and rubber bellow on delivery and suction,cyclic timer . including MS skid and mounting of the pumps on the skid.(Motor to be of the same make as the pump)
Pump Capacity (lpm) (675lpm)
Pump Head (25 mtr)
No. of Working Pumps (1 No.)
No. of Standby Pumps (Set 1)
Sump Pump
Supply, Installation, testing and commissioning of sump pump comprising the following:
Submersible centrifugal pumps with mechanical seal, CI casing, CI impeller and SS shaft , 2900 rpm with suitable capacity TEFC induction motor suitable for 220 ± 10 % volts, 1 phase, 50 cycles A.C. Supply.
Pump Capacity (lpm) (180 lpm)
Pump Head (10 mtr)
Solid Size (30 mm)
No. of Working Pumps (1 No.)
No. of Standby Pumps(1 No.)
Make of pump and motor- Kirloskar, wilo,Pressure Gauge-H Guru or Equivalent
DOMESTIC TRANSFER PUMPS
Supply, Installation, testing and commissioning of pumping system comprising the following:
Horizontal centrifugal monoblock pumps with mechanical seal, CI casing, CI impeller and SS 304 shaft , 2900 rpm connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia Pressure Gauge and rubber bellow on delivery and suction,cyclic timer . including MS skid and mounting of the pumps on the skid.(Motor to be of the same make as the pump)
Pump Capacity (lpm) (675 lpm)
Pump Head (35 mtr )
No. of Working Pumps (1 NO.)
No. of Standby Pumps (Set 1)
Make of pump and motor- Kirloskar, wilo,Pressure Gauge-H Guru
MULTIGRADE SAND FILTER
Supply Installation, Testing and commissioning of MSEP vessel filter with Butterfly valve, Frontal piping and distrubution system. Filter shall be suitable for working pressure of 3.5kg / cm² and shall include filter media, standard fittings like pressure gauges, sampling cock, rinse drain,
Capacity 40 cum/hr (DSR a)
Filtration rate 18 cum/hr (DSR b)
Height of shell (1.8 mtr) (DSR c )
Max. operating pressure (3.5 kg/sq cm) (DSR d)
Test pressure (5.5 kg/sq cm) (DSR e)
Working Hours (12 hr) (DSR f)
dia of filter (1.7 mtr) (DSR g)
Out Put Suspended solids : less than (5 PPM) (DSR h)
Media (minimum) (3200 Kg) (DSR i)
ACTIVATED CARBON FILTER (3.5 kg/sq cm)
Supply Installation, Testing and commissioning of MSEP vessel filter with Butterfly valve, Frontal piping and distrubution system. Filter shall be suitable for working pressure of 3.5kg / cm² and shall include filter media & Carbon media , standard fittings like pressure gauges, sampling cock, rinse drain,
Capacity 40 cum/hr
Filtration rate 18 cum/hr
Height of shell 1.8 mtr
Max. operating pressure (3.5 kg/sq cm)
Test pressure (5.5 kg/sq cm)
Working Hours (12 hr)
dia of filter (1700 mm)
Activated Carbon Media (1100 kg)
Apparent Density (600-650 kg/m3)
WATER SOFTENER PLANT
Supply Installation, Testing and commissioning of MSEP vessel filter with Butterfly valve, Frontal piping and salt injection system . vessel shall be suitable for working pressure of 3.5kg / cm² and shall include ion exchange Resin , standard fittings like pressure gauges, sampling cock, rinse drain, with Hardness Test Kit
Capacity 40 cum/hr
Height of shell (1.8 mtr)
Max. operating pressure (3.5 kg/sq cm)
Test pressure (5.5 kg/sq cm)
Working Hours (12 hr)
dia of vessel (1700 mm)
Ion Exchnage Resin (1650 ltr)
Salt tank for recharging (1000 ltr)
Supply, installation, testing and commissioning of magnetic level sensors and controllers, CPVC probe tube, PP actuating float and all other equipment required for the performance of the system to the satisfaction of the engineer in charge complete including providing and fixing wiring from control junction box near the UG tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. The level controller will perform the following functions.
To switch on the pumps ( tube well pumps, filter pumps,domestic water transfer pumps ) when the level of water in the supply water tank is low and to cut off the pump when the level in the recieving water tank is high.
To indicate 5 levels of water in all tanks through a control panle with LEDs
To start the pumps in a cyclic order.
The system shall be complete to ensure automatic operation of pump in accordance to water level in respective tanks.
Providing, fixing, jointing and testing in position the following medium class G.I. pipes conforming to IS:1239 cut to required lengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions, reducers, flanges & plugs etc. fixing at wall/ceiling level supported by clamps, hangers including paint etc, cutting hole in wall/floor/slab and making good the same good with cement concrete 1:2:4 / fire sealent complete as required.
65 mm dia
80 mm dia
100 mm dia
(Pipe Make -Jindal hisar or equivalent Fittings Make - Unik eqivalent )
Providing & fixing of butterfly valve (Wafer Type) of S.G. Iron disc (Body S.G. Iron, Without lungs, lever operated, S.G. Iron Disc, Nirtrile/EPDM Rubber Lining , test Pressure PN-16) with flanges, nut bolts, gaskets complete required.
65 mm dia
80 mm dia
100 mm dia
(Make - Kartar /Sant or Equivalent)
Providing & fixing of Cast Iron Dual Plate wafer Type Check Valve (PN 16) with SS-304 Discs and Nitrile Rubber Lining. Shell test Pressure - 24.5 Kg/Cm2 g) with flanges, Nut, bolts & washers, etc. complete as required.
65 mm dia
(Make - Karta/Sant or Equivalent)
Providing & fixing C.I. 'Y' Strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanges / union nuts, bolts & washers complete as required.
80 mm dia
(Make - Karta/Sant or Equivalent)
Supplying, installing, testing and commissioning of chlorine dosing system consisting of one HDPE tank of 100 litres capacity with a positive displacement diphragm dosing pump having variable flowrate of 0-6 lph. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. .(pump make -seeko, E Dos or equivalent. Tank make - sintex or equivalent)
ELECTRICAL
Supply ,installation,testing & commissioning of Wall mounted enclosed dust and vermin proof front operated cubical type panel of uniform width suitable for used on 415V 35 KA fault level 3 phase 4 wire, 50 c/s, febricated from 1.6/2mm CRCA sheet, powder coated complete housed with incoming and outgoing aluminium bus bar including supply , fixing of base channel of suitable size with undernoted switch gear & auto mation as per fire nomes.
INCOMER
1 No. 100A TPN MCCB (35 KA) with microprossor base.
1 Set of RYB phase indication lights with 2A MCB.
three phase energy meter
BUS BAR
150 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 1.00 sq mm / amp.
OUT GOING
Each set comprises
10 A -TP 10kA MCB "C" Curve-1no.
9A 3P Power Contactor-1no
2.1-3.1 A Overload Relay -1no
SPP-1no
On/Off Indicating Lamps-2nos
Start/Stop Push Buttons -2 nos
Control MCB-3nos
Cyclic timer -1 no
Out Going 7.5 HP DOL Starter -2 sets for feed pump(1W+1S)
Each set comprises
63Amp. TP MCB (10ka)"C" Curve-1Nos
32A 3P Power Contactor-1no
14-23A Overload Relay -1no
SPP-1no
Cyclic timer -1 no
A/M Switch
On/Off Indicating Lamps
Start/Stop Push Buttons
Control MCB 2amp.
Out Going 10 HP DOL Starter -2 sets for Transfer pump(1W+1S)
Each set comprises
40Amp. TP MCB (10ka)"C" Curve-1Nos
25A 3P Power Contactor-1no
9-14A Overload Relay -1no
SPP-1no
Cyclic timer -1 no
A/M Switch
On/Off Indicating Lamps
Start/Stop Push Buttons
Control MCB 2amp.
Note :- MCCB,MCB,Contractor, Relay , & SPP
MCCB : L&T D-Sine
MCB : L&T /Legrand
All the cts shall be Cast resin
Earthing Bus :
One (1) No. of Aluminium earthing bus of suitable size all along the Panel with 2 earthing bolts of suitable size..
Supply ,Laying,testing & commissioning of The suitable size PVC / XLPE insulated armoured aluminium conductor power cable from control panel to pumps will be included in above item along with terminations, cable glands & cable trays etc as required. (Cable Make :Finolex / Polycab / Rallison/RPG or equivalent)
3X6mm sq.aluminium armoured cable
3X10mm sq.aluminium armoured cable
PUMPING AND PIPING
FILTER FEED PUMPS
Supply, Installation, testing and commissioning of pumping system comprising the following:
Horizontal centrifugal monoblock pumps with mechanical seal, CI casing, CI impeller and SS 304 shaft , 2900 rpm connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia Pressure Gauge and rubber bellow on delivery and suction,cyclic timer . including MS skid and mounting of the pumps on the skid.(Motor to be of the same make as the pump)
Pump Capacity (lpm) 400 lpm
Pump Head - 25 mtr
No. of Working Pumps (1 nos.)
No. of Standby Pumps (1 nos.)
Sump Pump
Supply, Installation, testing and commissioning of sump pump comprising the following:
Submersible centrifugal pumps with mechanical seal, CI casing, CI impeller and SS shaft , 2900 rpm with suitable capacity TEFC induction motor suitable for 220 ± 10 % volts, 1 phase, 50 cycles A.C. Supply.
Pump Capacity (lpm) 180lpm
Pump Head - 10 mtr
Solid Size (30 mm)
No. of Working Pumps (1 nos.)
No. of Standby Pumps (1 nos.)
Make of pump and motor- Kirloskar, wilo or equivalent. Pressure Gauge-H Guru or equivalent as approved.
DOMESTIC TRANSFER PUMPS
Supply, Installation, testing and commissioning of pumping system comprising the following:
Horizontal centrifugal monoblock pumps with mechanical seal, CI casing, CI impeller and SS 304 shaft , 2900 rpm connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia Pressure Gauge and rubber bellow on delivery and suction,cyclic timer . including MS skid and mounting of the pumps on the skid.(Motor to be of the same make as the pump)
Pump Capacity (lpm) 500 lpm
Pump Head - 35 mtr
No. of Working Pumps (1)
No. of Standby Pumps (1)
Make of pump and motor- Kirloskar, wilo or equivalent, Pressure Gauge-H Guru or equivalent.
MULTIGRADE SAND FILTER
Supply Installation, Testing and commissioning of MSEP vessel filter with Butterfly valve, Frontal piping and distrubution system. Filter shall be suitable for working pressure of 3.5kg / cm² and shall include filter media, standard fittings like pressure gauges, sampling cock, rinse drain,
Capacity (24 cum/h)
Filtration rate (18 m3/hr)
Height of shell (18 mtr)
Max. operating pressure (3.5 kg/sq cm)
Test pressure (5 kg/sq cm)
Working Hours (12 hr)
dia of filter (1200 mm)
Out Put Suspended solids : less than (5 ppm)
Media (minimum) (2500 kg)
ACTIVATED CARBON FILTER
Supply Installation, Testing and commissioning of MSEP vessel filter with Butterfly valve, Frontal piping and distrubution system. Filter shall be suitable for working pressure of 3.5kg / cm² and shall include filter media & Carbon media , standard fittings like pressure gauges, sampling cock, rinse drain,
Capacity (24 cum/hr)
Filtration rate (18 m3/hr)
Height of shell (1.8 mtr)
Max. operating pressure (3.5 kg/sq cm)
Test pressure (5 kg/sq cm)
Working Hours (12 hr)
dia of filter (1200 mm)
Activated Carbon Media (700 kg)
Apparent Density (600 kg/cum)
WATER SOFTENER PLANT
Supply Installation, Testing and commissioning of MSEP vessel filter with Butterfly valve, Frontal piping and salt injection system . vessel shall be suitable for working pressure of 3.5kg / cm² and shall include ion exchange Resin , standard fittings like pressure gauges, sampling cock, rinse drain, with Hardness Test Kit
Capacity (Cum/h -25)
Height of shell (18 mtr)
Max. operating pressure ( 3.5kg/sq cm)
Test pressure (5 kg/sq cm)
Working Hours (12 hr)
dia of vessel (1200.0 mm)
Ion Exchnage Resin (1000 ltr)
Salt tank for recharging (1000 ltr)
Supply, installation, testing and commissioning of magnetic level sensors and controllers, CPVC probe tube, PP actuating float and all other equipment required for the performance of the system to the satisfaction of the engineer in charge complete including providing and fixing wiring from control junction box near the UG tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. The level controller will perform the following functions.
To switch on the pumps ( tube well pumps, filter pumps,domestic water transfer pumps ) when the level of water in the supply water tank is low and to cut off the pump when the level in the recieving water tank is high.
To indicate 5 levels of water in all tanks through a control panle with LEDs
To start the pumps in a cyclic order.
The system shall be complete to ensure automatic operation of pump in accordance to water level in respective tanks.
Providing, fixing, jointing and testing in position the following medium class G.I. pipes conforming to IS:1239 cut to required lengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions, reducers, flanges & plugs etc. fixing at wall/ceiling level supported by clamps, hangers including paint etc, cutting hole in wall/floor/slab and making good the same good with cement concrete 1:2:4 / fire sealent complete as required.
65 mm dia
80 mm dia
100 mm dia
(Pipe Make -Jindal hisar or equivalent. Fittings Make - Unik or eqvalent or as approved )
Providing & fixing of butterfly valve (Wafer Type) of S.G. Iron disc (Body S.G. Iron, Without lungs, lever operated, S.G. Iron Disc, Nirtrile/EPDM Rubber Lining , test Pressure PN-16) with flanges, nut bolts, gaskets complete required.
65 mm dia (DSR07a)
80 mm dia ( DSR07b)
100 mm dia (DSR06c)
(Make - Kartar /Sant or equivalent)
Providing & fixing of Cast Iron Dual Plate wafer Type Check Valve (PN 16) with SS-304 Discs and Nitrile Rubber Lining. Shell test Pressure - 24.5 Kg/Cm2 g) with flanges, Nut, bolts & washers, etc. complete as required.
65 mm dia
(Make - Karta/Sant or equivalent)
Providing & fixing C.I. 'Y' Strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanges / union nuts, bolts & washers complete as required.
80 mm dia
(Make - Karta/Sant or equivalent)
Supplying, installing, testing and commissioning of chlorine dosing system consisting of one HDPE tank of 100 litres capacity with a positive displacement diphragm dosing pump having variable flowrate of 0-6 lph. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. .(pump make -seeko, E Dos orf equivalent. tank make - sintex or equivalent)
Electrical
Supply ,installation,testing & commissioning of Wall mounted enclosed dust and vermin proof front operated cubical type panel of uniform width suitable for used on 415V 35 KA fault level 3 phase 4 wire, 50 c/s, febricated from 1.6/2mm CRCA sheet, powder coated complete housed with incoming and outgoing aluminium bus bar including supply , fixing of base channel of suitable size with undernoted switch gear & auto mation as per fire nomes.
INCOMER
1 No. 100A TPN MCCB (35 KA) with microprossor base.
1 Set of RYB phase indication lights with 2A MCB.
three phase energy meter
BUS BAR
150 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 1.00 sq mm / amp.
OUT GOING
Each set comprises
10 A -TP 10kA MCB "C" Curve-1no.
9A 3P Power Contactor-1no
2.1-3.1 A Overload Relay -1no
SPP-1no
On/Off Indicating Lamps-2nos
Start/Stop Push Buttons -2 nos
Control MCB-3nos
Cyclic timer -1 no
Out Going 7.5 HP DOL Starter -2 sets for feed pump(1W+1S)
Each set comprises
63Amp. TP MCB (10ka)"C" Curve-1Nos
32A 3P Power Contactor-1no
14-23A Overload Relay -1no
SPP-1no
Cyclic timer -1 no
A/M Switch
On/Off Indicating Lamps
Start/Stop Push Buttons
Control MCB 2amp.
Out Going 10 HP DOL Starter -2 sets for Transfer pump(1W+1S)
Each set comprises
40Amp. TP MCB (10ka)"C" Curve-1Nos
25A 3P Power Contactor-1no
9-14A Overload Relay -1no
SPP-1no
Cyclic timer -1 no
A/M Switch
On/Off Indicating Lamps
Start/Stop Push Buttons
Control MCB 2amp.
Note :- MCCB,MCB,Contractor, Relay , & SPP
MCCB : L&T D-Sine
MCB : L&T /Legrand
All the cts shall be Cast resin
Earthing Bus :
One (1) No. of Aluminium earthing bus of suitable size all along the Panel with 2 earthing bolts of suitable size..
Supply ,Laying,testing & commissioning of The suitable size PVC / XLPE insulated armoured aluminium conductor power cable from control panel to pumps will be included in above item along with terminations, cable glands & cable trays etc as required. (Cable Make :Finolex / Polycab / Rallison/RPG or equivalent.)
3X6mm sq.aluminium armoured cable
3X10mm sq.aluminium armoured cable
SUB HEAD-F: ETP
EFFLUENT TREATMENT PLANT : 60 KLD CAPACITY
Preliminary Works
All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under “Basis of Design” in the specifications. Type of equipment, material specification, methods of installation and testing and type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian Standards, however capacity of each component and their quantities shall be such as to fulfill the below mentioned requirements.
The unit rate for all equipment or materials shall include cost in INDIAN RUPEES (INR) for all materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution as per Specifications and Drawings including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required or called for in item.
In the event of conflict between Bill of Quantities and other documents including the Specifications, the most stringent shall apply. The interpretation of the Architect / Consultant /Project Manager shall be final and binding.
All requirements of Specifications, whether such requirements are mentioned in the item or not shall be met. The Specifications and Drawings where available, are to be read as complimentary to and part of the Bill of Quantities and any work called for in one shall be taken as required for all.
The contractor shall include for making all the opening in slabs, beams, walls etc. as required for his work. However, the contractor can coordinate with civil work to provide necessary sleeves. All hot and cold water supply pipes crossing masonry walls of toilets shall be provided with GI pipe sleeves. The annular space between the pipe and sleeve shall be filled up with glass wool in between and fire proof sealent on either end after testing. All openings shall be closed using water proofing compound or as specified by Project Manager.
The work shall be carried out in conformity with the plumbing drawings and within the requirements of architectural, HVAC, electrical structural and other specialized services drawings. The contractor shall cooperate with all trades and agencies working on the site. He shall make provision for hangers, sleeves, structural openings and other requirements well in advance to prevent hold up of progress of the construction schedule. All supports to the civil structure shall be provided with anchor fastners.
On award of the work, contractor shall submit a schedule of construction in the form of a PERT chart or BAR chart for approval of the Project Manager.
Contractor must submit for approval shop drawings, that detail pipe routing and levels, showing location of other services at crossings etc., cable runs, route cable trays and all allied works and must be fully coordinated with other services, before execution of the works. All shop drawings will be made on Autocad and coloured prints has to be produced for site work.
The contractor shall, from time to time, clear away all debris and excess materials accumulated at the site failing which the same shall be done by Project Manager at contractor’s risk and cost and cost of clean up shall be deducted from the contractors prorata bill. After the fixtures, equipment and appliances have been installed and commissioned, contractor shall cleanup the same and remove all plaster, paints, stains, stickers and other foreign matter or discoloration leaving the same in a ready to use condition. Contractor shall demolish all stores, remove all surplus materials and leave the site in a broom clean condition
The contractor shall submit detailed GA drawings, flow diagrams, equipment list, power load requirement.
The contractor must do and provide in detail, design, calculations of all elements of the plant, electrical and mechanical work to satisfy adequacy of design
Contractor shall ensure submission of GOOD FOR CONSTRUCTION' stage architectural, structural, construction, electrical, mechanical and piping drawing, detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for main components and additional components such as inserts, puddle flanges, vent pipes etc. for approval.
Design, Supply, Fabrication, installation, testing and commisioning of effluent treatment plant with effluent handling capacity 60 m3 per day. The entire plant will be constructed in MS (FRP coated, min. 3 mm). The ETP shall be designed as water retaining structures, with necessary chemical dosing as required by the manufacturer's design. All the equipment, piping, pumps, air blowers and electrical panel to be housed in the ETP skid including M.S. puddle flange (Galvanised), inlet, outlet, overflow, vent, moving ladders & railing. The Plant shall be complete with a central Electrical Power and Control panel fully pre/site wired and with all power and control cables to all pumps and equipment including all instrumentation, level and other controls. The cost will also include any consequential civil work including making foundations for the structure, pumps, blowers etc. It should be complete as per manufacturer's specifications & as directed by Engineer-in-charge.
Effluent from Labs etc. Some solvent/ chemical waste originating typically from hospital complex shall also be discharged into the ETP. Design to take consideration of same.
Daily average flow : 60 Cum/Day
BOD : 250 - 600 mg/l
S. Solids : 200 - 650 Mg/l
COD : 600 - 1200 mg/l
Oil & Grease : 50-140 mg/L
Effluent discharge standard after treatment :-
S. Solids : Less than 150 mg/l
COD : Less than 100 mg/l
Oil & Grease : Less than 5 mg/l
BOD : Less than 10 Mg/L
The ETP shall consist of following units but not limited to these unit as may be required by the manufacturer's design. MS PVC coated rungs in all tanks & Platform for maintenance etc. complete as required.
SS Perforated basket screen having provision for chain lifting arrangement etc. complete as required.
Supply, installation, testing & commissioning of Flash Mixer Quantity 01 number Drive 1.5 HP motor with gear Capacity 6 m3/Hour MOC: MS with FRP lining 1.1 mm inside
Supply, installation, testing & commissioning of Flocculator Quantity 01 number Drive 1.5HP motor with gear Capacity 6 m3/Hour MOC: MS with FRP lining 1.1 mm inside
Supply, installation, testing & commissioning of Tube Settler Quantity 01 number MOC MS with FRP lining 1.1 mm inside Capacity 10 KL/Hour
Supply, installation, testing & commissioning of Media in Tube Settler Quantity 5.0 m3 (APPROX.) Type Corrugated MOC PVC
Providing and fixing all piping (as described below) and isolation control valves, non return valves etc. for making the system complete.
PVC piping (10kg/sqcm) - For all submerged waste water piping.
MS (C Class) - For all exposed air piping and flexible stainless steel pipe for submerged air piping.
GI (C class) for all other water piping.
Providing and fixing all instrumentation eg. Pressure guages, level controllers, sensors, rotametres for air, water etc. for making the system complete.
Capacity : 2 M3/hr @ Discharge Head 10 M head (2 Nos.-1 Working + 1 Standby) From Effluent tank to equalization tank of STP
Mono block centrifugal Sludge Disposal Pumps Capacity : 1 M3/hr @ Discharge Head 10 M head (2 Nos. - One working & one stand by) From Effluent tank to Sludge Holding tank of STP
Cost shall be inclusive of PVC flexible Hose pipe ( for piping submerged in effluent) with M S epoxy piping (for piping non-submerged in effluent)
Providing and fixing lime/alum/polyelectrolyte dosing system consisting of ABS dosing pump (0-6 lph) with 100 lit HDPE tank including all piping from the dozer to the reaction tank etc. complete in all respects. 3 nos. (alum/lime/polyeelctrolyte) in flash mixer & 1 no. in tube settler (alum)
Supplying, installing, testing and commissioning of high speed Agitator of SS 304 and Flocculator complete with single phase motor for flash mixer.
Constructing Grease Trap with belt type oil skimmer of suitable size of minimum 1200mm liquid depth in brick work of class 75 with cement mortar (1:6), inside plastering 16 mm thick with cement mortar 1:3 with floating coat of neat cement and rough plaster on outside. Including SS bucket as per detail to collect the grease. RCC top slab with 500 mm dia medium duty manhole covers with frame. It should be complete with belt type oil & grease skimmer.
Supply & installation of treated water holding tank of HDPE material of 500 lit. minimum storage capacity or as required meeting functional requirements.
Electrical Installation
Supply, Installation, Testing and Commissioning of ETP Panel cubicle type, made out of 14 swg CRCA sheet steel, totally enclosed, IP-52, protection free standing, floor mounting, dust and vermin proof ,indoor, compartmentalised, powder coated painting suitable for operation on 3 Phase and neutral, 415v, 50 Hz AC supply system with busbars extensible on both sides, interconnections with suitable size of copper leads/ solid aluminium strips, all MCCB's shall be provided with O/C & S/C releases all as shown on drawing including supply & installation,earthing complete as required and as per specifications:
Incoming
100 amps TP+M MCCB with the following accessories:
Phase indicating lamps protected by 2 amp SP MCB 3 Sets
Bus Bar
150 amps TPN (25 KA) aluminium bus bar with heat shrinkable insulation sleeves.
Outgoings
For Lighting & Power inside WTP plant room:-1 no. 63 Amp 4P (10 KA, C curve) MCB, OVERLOAD RELAY, SHORT CIRCUIT RELAY
All Incoming/ Outgoing Feeders shall be with suitable size switchgear & rating of starter alongwith Busbar sizing to meet the functional requirement of Pump & other Equipment. Nothing extra will be paid in this regard.
Spare MCB’s of following capacities to be provided in this panel as mentioned below:-
63 Amp 4P MCB - 1 No.
9-15 Amp TP MPCB’s 1 No.
23-32 Amp TP MPCB’s 1 No.
Complete Item as mentioned above
Supply,installation,testing and commissioning of XLPE insulated PVC sheathed 1.1 KV grade armoured Copper control cables for various equipment through walls / ceilings with appropriate clamps / fixing arrangements and complete with termination as per manufacturer's specifications & as directed by Engineer-in-charge.
3C x 1.5 Sq. mm
4C x 1.5 Sq. mm
Supplying and making end termination with brass double compression gland and Aluminium lugs for following size of XLPE insulated and PVC sheathed copper conductor cable of 1.1 KV grade as required.
3 core x 10 Sq.mm.
3 core x 6 Sq.mm.
Supply, installation, testing & commissioning of XLPE insulated and PVC sheathed Copper conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 with upto date amendments of following sizes
3 core x 10 Sq.mm.
3 core x 6 Sq.mm.
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. The cost shall include Tees, bends etc.
150 mm width x 50mm depth x 1.6 mm thickness.
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge. It should be complete as per specifications & directions of Engineer-in-charge.
NOTE: Contractor shall include all electrical and mechanical items as required to operate the system automatically and also include in his rates any other components/tanks/ equipment/ etc. required to complete the job as required. Only main power supply with the earthing to be ETP main control panel shall be provided by the owner through other agencies. The electrical panel will also include all the required NO/NC contacts, contactors etc. required to provide BMS connectivity.
Bypass arrangement shall be provided such that equalization tank pump can be used to pump out sewage to external manhole incase of maintenance of ETP.
All piping interconnection with Sewage Treatment plant shall be considered in the scope of work.
All water meters shall be considered for Effluent treatment plant.
Contractor shall include provision of separate MDBs for light and power requirement of the plant room. Power supply shall be taken from above panel
Operation & Maintenance Work
To operate the entire ETP under available load conditions for further period of 30 days on round the clock basis.
To provide services of contractors expert operating personal comprising of :
One Supervisor 4 hrs Three times a week.
One Plant operator one per shift in three shifts.
One helper for general maintenance and assistance. One per shift in three shifts.
Company’s back up services of senior engineers and experts for any major problems, general check up and maintenance and advise. Once a week for 2 hours minimum more or more if required.
All tools, equipment and testing devices to be provided by the contractor.
Consumable including lubricants and chemicals will be provided by Owners.
SUB HEAD-G:Rain Water Harvesting
Single Bore Rain Water Harvesting
Constructing Desilting tank for rain water harvesting with brick work in cement mortar 1:4 (1 cement and 4 coarse sand), baffle walls in brick masonary in 1 : 4 (1 cement : 4 coarse sand), RCC slab 1:1.5:3 (1 cement, 1.5 coarse sand, 3 graded stone aggregate 20 mm. nominal size). Providing and laying coarse sand in 500 mm thick layer at the bottom of tank, 600x600x75 mm RCC deflector, inlet, outlet and over flow arrangements. The rates includes all necessary excavation in all kind of soils, refilling and disposal of surplus earth with in the site or away from site as directed with out any extra cost including centering,shuttring etc.complete with required nos. heavy duty SFRC type MH covers and frames as per IS : 12592 and all other assessories as per the drawing. Size: 2500 x 2000 x 2000 mm effective depth (Total depth = 3.10 meter) ( DSR02NSR)
Construction of Ground water recharge pit of 2500x2500 mm dia & 2000 mm effective depth (Total depth = 3.10 meter) including providing all material, labour, T&P etc including excavation in all kind of soil and disposal of earth as directed, including centering, shuttring etc to complete the work as per following details :- (DSR155NSR)
Construction of brick masonry recharge pit of above size by 1:4 cement coarse sand mortar and necessary foundation by 1:4:8 cement concrete. (DSR08NSR)
RCC slab (1:1.5:3) at top of min 150 thick with 2 nos 560 mm dia heavy duty SFRC MH frame and cover as per IS : 12592. (DSR6NSR)
Providing 3 layers of filter media comprises of 500 mm thick 50-150 mm boulders, 500 mm thick 5-10 mm gravel & 500 mm thick coarse sand at the bottom of pit below effective depth. All three layers shall be separated by MS wire mesh. (DSR99NSR)
Drilling of recharge bore well of about 250 to 300 mm dia. by manual means / rig machine upto a depth till 5 meter above highest water table. (DSRNSR)
Providing & lowering of 160 mm outer dia PVC tubewell casing / slotted pipe (6 kg/sq.cm) with top socket & plug. (DSR21NSR)
tubewell accessories as required.
Filling of 1.6 - 4.8 mm dia. pea gravel allround tubewell. (DSR20SR)
Masonry intake screen channel with MS screen of 20 mm opening size, 600 x 600 mm RCC deflector and providing overflow to outer drain.
Double Bore Rain Water Harvesting
Constructing Desilting tank for rain water harvesting with brick work in cement mortar 1:4 (1 cement and 4 coarse sand), baffle walls in brick masonary in 1 : 4 (1 cement : 4 coarse sand), RCC slab 1:1.5:3 (1 cement, 1.5 coarse sand, 3 graded stone aggregate 20 mm. nominal size). Providing and laying coarse sand in 500 mm thick layer at the bottom of tank, 600x600x75 mm RCC deflector, inlet, outlet and over flow arrangements. The rates includes all necessary excavation in all kind of soils, refilling and disposal of surplus earth with in the site or away from site as directed with out any extra cost including centering,shuttring etc.complete with required nos. heavy duty SFRC type MH covers and frames as per IS : 12592 and all other assessories as per the drawing. Size: 2500 x 2000 x 2000 mm effective depth (Total depth = 3.10 meter) (DSR19NSR)
Construction of Ground water recharge pit of 2500x2500 mm dia & 2000 mm effective depth (Total depth = 3.10 meter) including providing all material, labour, T&P etc including excavation in all kind of soil and disposal of earth as directed, including centering, shuttring etc to complete the work as per following details :- (DSR17NSR)
Construction of brick masonry recharge pit of above size by 1:4 cement coarse sand mortar and necessary foundation by 1:4:8 cement concrete. (DSR67NSR)
RCC slab (1:1.5:3) at top of min 150 thick with 2 nos 560 mm dia heavy duty SFRC MH frame and cover as per IS : 12592. ( DSR15NSR)
Providing 3 layers of filter media comprises of 500 mm thick 50-150 mm boulders, 500 mm thick 5-10 mm gravel & 500 mm thick coarse sand at the bottom of pit below effective depth. All three layers shall be separated by MS wire mesh. ( DSR14NSR)
Drilling of recharge bore well of about 250 to 300 mm dia. by manual means / rig machine upto a depth till 5 meter above highest water table. (DSR33NSR)
Providing & lowering of 160 mm outer dia PVC tubewell casing / slotted pipe (6 kg/sq.cm) with top socket & plug. (DSR58NSR)
tubewell accessories as required.
Filling of 1.6 - 4.8 mm dia. pea gravel allround tubewell. (DSR89NSR)
Masonry intake screen channel with MS screen of 20 mm opening size, 600 x 600 mm RCC deflector and providing overflow to outer drain.
SUB HEAD-H:PUMPS
Providing,fixing & installation of submersible type drainge Pump volute material cast iron impeller material motor would be 380-415v cable length 5 meters pump. (RA-11)
Flow rated 12.00 cum/hr
Head, rated (requested) 20 meter
Head Rated Actual (20 m)
Speed 2900 RPM
Product Type: VERTICAL MULTISTAGE PUMP Product Configuration Pump Classification: Hydro-Pneumatic Booster System Pump Construction: Pump With Motor Parallel Pumping System Numbers of Pump in System: 3 Pump Component Materials Version: Cast Iron & S.S AISI 304 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Motor Specifications Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE1 Motor Manufacturer: Lubi System Components Accessories: Included Header Flange Rating: PN 16 Pump Controller: Single VFD with HMI & PLC Pump Controller Rating: 7.5 HP HPN Pressure Tank: 200 litre (RA-12)
Flow Rate- 800 lpm
2 Working + 1 Stand By
Head 100 m
Speed 2900 rpm
Product Configuration Pump Classification: Hydro-Pneumatic Booster System Pump Construction: Pump With Motor Parallel Pumping System Numbers of Pump in System: 3 Pump Component Materials Version: Cast Iron & S.S AISI 304 Seal Material: Cartridge-Carbon/SiC/SS316/FKM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Motor Specifications Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE1 Motor Manufacturer: Lubi System Components Accessories: Included Header Flange Rating: PN 16 Pump Controller: Single VFD with HMI & PLC Pump Controller Rating: 7.5 HP HPN Pressure Tank: 200 litre (RA-15)
Flow 500 lpm
Two Working+ 1 stand by.
Head Rated Actual (80 m)
Speed 2900 RPM
Providing,fixing & installation of mono blcok Pump volute material cast iron impeller material motor would be . (RA-17)
Flow rated 1027 lpm
Head Rated Actual (10 m)
Providing,fixing & installation of mono blcok Pump volute material cast iron impeller material motor would be .
Flow rated 700lpm
Head Rated Actual (10 m)
SUB HEAD-I :BORING WORK
Shifting of Drilling Machine (1 Job)
Drilling of Bore suitable for lowering of 8X6 MS pipe (150mt)
Lowering of Assembly (90 Mt)
Bentonite required for borewell (Bag of 50 kgs) (15 bags)
Logging of borewell 1 job)
MS ERW Pipe of 200mm dIa 5.2mm dia (60 mt)
MS ERW Pipe of 150mm dIa B Class (15 mt)
MS ERW Slotted pipe of 150mm dIa (15 mt)
Peagravel (15 Cum)
MS O rings 200mm (10 nos.)
MS O rings 150mm (10 nos.)
MS Reducer 200X150mm (1 nos.)
MS Clamp 200mm (1 nos.)
Bail Plug 150mm (1 nos.)
Assembly Support MS (1 nos.)
Shifting of Air Compressor (1 job)
Running of Compressor (25 hrs)
Shifting of Electrical OP Unit (1 job)
Running of Electrical OP unit / Development for 15 HP Submerssible Pumpset (120 Hrs)
Submersible pump 12.5 Hp 250 LPM at 45 mts head (1 set)
MS Column Pipe 50mm dia of 3mts with Flange end complete with Rubber packing and Nut Bolt (15 nos.)
Supply of Pump accessories inclusive of Butterfly valve etc ( 1 set)
Wall Mounted Switch Panel Board starter and submersible cable (1 set)
Installationand commissing of Submersible Pump
INTERNAL ELECTRICAL WORKS
SUB-HEAD - I : INTERNAL WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (DSR 1.3)
Group -C (DSR 1.3.3)
Group -C (With Germ free Switch) (MR)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (DSR 1.10)
Group -B (DSR 1.10.2)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required (DSR 1.54)
Group C (DSR 1.54.3)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required (DSR 1.55)
Group -B (DSR 1.55.2)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (DSR 1.7)
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (DSR 1.7.1)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (DSR 1.7.2)
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DSR 1.7.2)
4 x 6 sq.mm + 2 x 6 sq.mm. earth wire (DSR 1.7.9)
4 x 10 sq.mm + 2 x 6 sq.mm. earth wire (DSR 1.7.10)
4 x 16 sq.mm + 2 x 6 sq.mm. earth wire (DSR 1.7.11)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR 1.14)
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (DSR 1.14.1)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (DSR 1.14.2)
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DSR 1.14.4)
4 x 6 sq.mm + 2 x 6 sq.mm. earth wire (DSR 1.14.9)
4 x 10 sq.mm + 2 x 6 sq.mm. earth wire (DSR 1.14.10)
4 x 16 sq.mm + 2 x 6 sq.mm. earth wire (DSR 1.14.11)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (DSR 1.31)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (DSR 1.32)
Supplying and fixing 25 amps, 240 volts, SPN modular socket outlet, with 2 pole and earth,along with 25 amps "C" curve, SP modular MCB with modular cover sheet and concealed GI Box complete in all respect as required. (DSR 2.18)
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (DSR 2.20)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required (DSR 1.5)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required (DSR 1.12)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (DSR 1.25)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required (DSR 1.26)
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required (DSR 1.38)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR 1.20)
20mm dia conduit (DSR 1.20.1)
25mm dia conduit (DSR 1.20.2)
32mm dia conduit (DSR 1.20.3)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(E LV wiring) (DSR 1.21)
20mm dia PVC conduit (DSR 1.21.1)
25mm dia PVC conduit (DSR 1.21.2)
32mm dia PVC conduit (DSR 1.21.3)
Raceway
Supply, fixing & installing of MS floor trunking with cover of following size embeded in floor by cutting the existing floor to be in flush to the existing floor finish level and rendering the floor complete with cement concrete as approved layout complete as required for power/telepone / data in unit of 1 length of 2.5 meter each including al accessories to complete job similar to CTM Engg., Slotco, Profab, OBO or equivalent. (MR)
300 mm X 38 mm - 3 Compartments
225 mm X 38 mm - 3 Compartments
150 mm X 38 mm - 1 Compatments
100 mm X 38 mm - 1 Compartments
75 mm X 38 mm - 1 Compartments
50 mm X 38 mm - 1 Compartments
SUB-HEAD II - FANS & LIGHT FIXTURES:
Supply of 2'x2' 30/31 Watt, Indoor Recess mounting LED Square Fitting for Armstrong Ceiling Powder quoted CRCA housing body diffuser of Special Polycarbonate material and driver set complete in all respect, 3600 system lumens, 70mm height with fully covered PMMA diffuser type, 110lm/W, CCT 6500, PF>0.95, THD <10% at full load, CRI>80, Flicker free (Ripple<5% rated output current), 2.5Kv Surge, Avg Life Class 50000Hrs @L70, complete in all respect. Equivalent to Philips RC380B LED36S -6500 G4 L60 W60 PSU OD / BAJAJ BZRSQL 36L / Wipro/ Havells (MR)
Supply of 2'x2' 30/32Watt, Indoor Recess mounting LED Square Fitting for Armstrong Ceiling Powder quoted CRCA housing body diffuser of Special Polycarbonate material and driver set complete in all respect, 125 Lm/W, CCT 6500, PF>0.95, THD <10% at full load, CRI>80, Flicker free (Ripple<5% rated output current), 2.5Kv Surge, Avg Life Class 50000Hrs @L70, complete in all respect.Equivalent to Philips RC600B LED40S/865 PSU W60L60 IN / BAJAJ BCRSP / Wipro/ Havells (MR)
Supply of 2'x2' 36Watt, Clean Room recess mounting LED Square Fitting, Powder quoted CRCA housing body with clear acrylic cover of Special Polycarbonate material and driver set complete in all respect, with min 3300 system lumens, suitable for front opening. CCT 6500, PF>0.90, THD <10% at full load, CRI>80, & Avg Life Class 50000Hrs @L70, complete in all respect. Equivalent to Philips CR652B LED33S CR CW CA / BAJAJ BPRF 36W / Wipro/ Havells (MR)
Supply of 2'x2' 30Watt, Indoor Recess mounting LED Square Fitting for Armstrong Ceiling Powder quoted CRCA housing body diffuser of Special Polycarbonate material and driver set complete in all respect, 3600 system lumens, with fully covered PMMA diffuser type, 120lm/W, CCT 6500, PF>0.90, THD <10% at full load, CRI>80, Avg Life Class 40000Hrs @L70, complete in all respect. / BAJAJ BZRSQL 36L (30W) / Wipro/ Havells (MR)
Supply and fixing of Recess mounting round 6 Watt 8 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-880 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect, Make : Philips / BajajBGSLO Sleek/Wipro/ Havells (MR)
Supply and fixing of Surface mounting round 13 Watt 15 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect Make:Philips / Bajaj BAJAJ BPSLR 15W /Wipro/ Havells (MR)
Supply and fixing of 23 / 28W watt 4ft Rail fitting suitable for Ceiling & Suspended mounting only with 2800 system lumens, having Powder coated CRCA housing integrated LEDs, diffuser and searviceable driver set complete in all respect with Avg Life 50k Hrs @L70, 120lumen/W, IP20 complete in all respect. Euivalent to Philips RC780B LED26S-6500 PSU W6L120 OD SI / BAJAJ BPCS 28W / Wipro/ Havells (MR)
Supply, installation, connecting, testing and commissioning of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor, Similar to Philips MakeBN021 LED20S / BAJAJ BCLAB 20W / Wipro/ Havells (MR)
Supply of surface/wall mounted occupancy sensor enabled LED Batten with a system lumen output of 4800 lumens and a min system efficacy of 120 lumen/watt, have a CRI > 80. The luminaire is made of CRCA housing and shall have diffused optics. wattage 40 W, P.F>0.95, CRI>80, 2.5kV inbuilt surge protection, & high-low cut-off circuit beyond input voltage 140-270V with auto & restart facility. The encapsulated driver should be replaceable & maintain on site. Make: Philips / BAJAJ BLTRU 48L / Wipro/ Havells (MR)
Supplying, fixing, connecting, testing and commissioning of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required,Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. Similar to Philips Cat. No. ULTRON, STYLISH LIVING BAJAJ BCLSB 10W / Wipro/ Havells (MR)
Supplying, fixing, connecting, testing and commissioning of Bulkhead type light fitting complete with , wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required.Similar to Philips Cat. No. Endura LED or equivalent / BAJAJ BIBWP 10W / Wipro/ Havells (MR)
Supply, installation, connecting, testing and commissioning of LED Patint bed light with a nominal system lumen output of 1553 lumens and a minimum system efficacy of 153 lm/W. The luminaire shall have a rated system lifetime of 50000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80, beam angl of LED 120 degree. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 28 W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. Make: Philips /Bajaj/ / Wipro/ Havells (MR)
Supply and fixing of Recess/ Surface mounting Square/ Round 18 Watt , suitable for 24Hr Continuous Operation, 1980-2200 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect. Similar to PHILIPS SM200C LED16S 6500 PSU OD WH / BAJAJ BGSLO SLEEK SURFACE 18W / Wipro/ Havells (MR)
Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 70W Watt. Confirming to IP 66 protection having Company LOGO Engraved complete in all respect with 7200 system lumens, High Power LED with lenses, >120lm/W, PF>0.95, THD <10% at full load, CRI>70, Avg Life Class 50000Hrs@L70 BAJAJ ENXT 72L / Wipro/ Havells (MR)
Supplying, erection, connecting, testing and commissioning of 1200mm sweep ceiling fan complete with blades, down rod, shackle insulator, canopy etc. including connection with 1.5 sqmm FRLS PVC insulated copper conductor. MAKE: BAJAJ SPEED STER OR Usha/ Khaitan/Orient (MR)
Supplying, erection, connecting, testing and commissioning of 1400mm sweep ceiling fan complete with blades, down rod, shackle insulator, canopy etc. including connection with 1.5 sqmm FRLS PVC insulated copper conductor. MAKE: BAJAJ SPEED STER OR EQ Usha/ Khaitan/Orient (MR)
Supplying, erection, connecting, testing and commissioning of 750 mm sweep wall fan five star rating complete with blades, down rod, shackle insulator, canopy etc. as required,Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. Bajaj Supreme Plus OR EQ approved make (MR)
Supplying, erection, connecting, testing and commissioning of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.
a) 300mm 900 RPM (Bajaj Max Air or Eq.Approved make only ) (MR)
b) 450mm 900 RPM (Bajaj Supreme Dlx. Or Eq.Approved make only ) (MR)
Supply, installation, connecting, testing and commissioning of occupancy cum photo sensor including all wiring to control the light fixtures in the circuit in the existing conduits required similar to Philips cat no. occuswitch (DSR 15.1)
Supply and fixing of Recess/ Surface mounting Square/ Round 40 Watt , Cut out Min 250m, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr Continuous Operation, 1980-2200 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect. Similar to PHILIPS RS271B LED40/ 830 PSU E MB WH / BAJAJ BXTAP 40W or Eq/Wipro/Havells (MR)
SITC of aviation lighting fitting complete with all respect. Make: Philips / Bajaj or Eq.Wipro, Havells (MR)
Supply, Instalation, connection, testing and commissioning of 3 Phase 4 wire 3 X 240 V (+20% to -40%, neutral solidly grounded) 50 Hz +/- 5% , 10 -60 amp. , energy meter Accuracy class 1.0 complete in all respect. Make : L & T or Eq.approved make (MR)
SUBHEAD- III: M.V. PANELS/ DISTRIBUTION BOARD
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required (DSR 2.2)
200 A, 35 KA,TPMCCB (DSR 2.2.12)
Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR 2.3)
12 way, Double Door (DSR 2.3.3)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR 2.4)
4 Way Double door (DSR 2.4.1)
6 way Double door (DSR 2.4.2)
8 way Double door (DSR 2.4.3)
12 way Double door (MR)
Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) (DSR 2.5)
4 way (4 + 12), Double door (DSR 2.5.1)
12 way (4 + 36), Double door (DSR 2.5.3)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2.12)
40 amps (DSR 2.12.1)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2.15)
40 amps (DSR 2.15.2)
63 amps (DSR 2.15.3)
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required (DSR 2.13)
40 amps (DSR 2.13.1)
63 amps (DSR 2.13.2)
Supplying and fixing following rating, Automatic Changeover With Current Limiter
SPN 30A MAIN 6A DG ACCL (MR)
SPN 30A MAIN 15A DG ACCL (MR)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2.10)
Single pole (DSR 2.10.1)
Supply installation testing and commissioning of wall / free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware, 3mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel, dully painted by 2 coat of zinc / Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU / Neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate MS base channel, hinged door with inter locking arrangement for equipment / switch gear.
Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3mm thick for separately cable alley to BBC from switch chember. Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection. (only outer area on all sides shall be measured). Size 1800x1300x450mm deep. (HSR 31.63)
Supplying and fixing of Copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending , cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation Complete in all respect. (HSR 31.64)
Supply & fixing of rotary handle for on / off operation of existing MCCB in the LT panel including fixing the same in position with all labour and material required to complete the job in all respect. (HSR 31.66)
up to 125A MCCB (i)
Above 125A MCCB (ii)
Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 31.69)
4 pole MCCB 6 amp to 63 amp
4 pole MCCB 100 amp
4 pole MCCB 200 amp
4 pole MCCB 300 amp to 400 amp
4 pole MCCB 500 amp
SITC of Nos ACB 1000A 4P EDO OL,SC,EF with display (minimum 03 line & maximum 04 line) with communication module for real data assessment like events,fault and all current parameters (MR)
SITC of Nos ACB 800A 4P EDO OL,SC,EF with display (minimum 03 line & maximum 04 line) with communication module for real data assessment like events,fault and all current parameters (MR)
SITC of Nos ACB 630A 4P EDO OL,SC,EF with display (minimum 03 line & maximum 04 line) with communication module for real data assessment like events,fault and all current parameters (MR)
SUB HEAD-IV : T.V. , TELEPHONE SYSTEM
Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: (DSR 2018 1.18)
2 Pair (4 core) (DSR 2018 1.18.2)
Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.63mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. (MR)
20 Pair telephone cable (MR)
10 Pair telephone cable (MR)
5 Pair telephone cable (MR)
Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. (MR)
5 Pair tag block (MR)
10 pair tag block (MR)
100 pair tag block (MR)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR 1.20)
20mm dia PVC conduit (DSR 1.20.1)
25mm dia PVC conduit (DSR 1.20.2)
32mm dia PVC conduit (DSR 1.20.3)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required (DSR 1.27)
1 or 2 Module (75mmX75mm) (DSR 1.27.1)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (DSR 1.24)
Supplying and fixing M.S. box with modular type telephone (RJ-11) outlet complete as required. (DSR 1.24.6)
Supplying and fixing M.S. box with modular type coaxial outlet for TV antenna complete as required. (DSR 1.24.7)
Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. (DSR 1.19)
SUBHEAD: - V - EARTHING
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each (DSR 2.21)
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. (DSR 5.4)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required (DSR 5.6)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) (DSR 5.8)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) (DSR 5.9)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required (DSR 5.10)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required (DSR 5.11)
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. (DSR 5.12)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. (DSR 5.14)
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. (DSR 5.15)
SUBHEAD-VI- LIGHTNING PROTECTION SYSTEM
Supply, Erection, Installation & Commissioning of External Lightning Wide Area Protection System based on pro-active Early Streamer Emission (ESE) Technology. No external power source required. Break down time not more than 245.5 Micro second. Wind Resistance up to 120miles/hours. Produces a leader of not less than 2x10E8 V/m/s in the lightning generated electromagnetic field with Level-I protection radius of 79 meters at 5 mtr. Mast including mast for supporting the device. Device confirming to NFC17-102 & UNE 21186 standards & CPRI Tested. (MR)
Supply, Erection, Installation & Commissioning of the Down Conductor which is a 70 Sq. mm flexibile, single core pvc insulated copper cable . (MR)
Supply, Erection, Installation & Commissioning of Lightning Event Counter (Model: LEC-IV) for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor and the triggering impulse should be > = 1.5 KA for 8/20µs. The Lightning Event Counter should be robust, non-resettable mechanical counter with IP65 rated enclosure suitable for external application. (MR)
Supply, Erection, Installation & Commissioning of the Earthing system which should cater for the Lightning Protection System earthing and should be maintenance free. Earth Enhancing Compounds should be used to treat the soil for lowering the effective ground impedance. Maintenance free earth pits made of ground enhancing material (GEM) - 3 or 4 bags of 11.3 Kg each and 250 microns copper bonded ground rods - 4 nos of size 5' length and 5/8" diameter connected with each other with 25 x 3 mm Copper Strip and high performance earth clamps. (MR)
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. (DSR 5.4)
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (DSR 6.2)
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. (DSR 6.4)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) (DSR 6.7)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) (DSR 6.8)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Each of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. (DSR 6.12)
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. (DSR 6.14)
SUB HEAD-VII : RISING MAIN
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
400 A 25kA SC for 1 sec (DSR 1.13.1)
500 A 30kA SC for 1 sec (DSR 1.13.2)
630 A 50kA SC for 1 sec (DSR 1.13.3)
800 A 50kA SC for 1 sec (DSR 1.13.4)
1000 A 50kA SC for 1 sec (DSR 1.13.6)
Supplying, installation, testing and commissioning of following ratings of tap-off boxes with MCCB for the above mentioned rising mains with indicating lamps etc., earthing, connections, as per specifications complete as required. (MR)
200 Amps TPN MCCB,36 KA (MR)
250 Amps TPN MCCB ,36 KA (MR)
Supplying, installation, testing and commissioning of following ratings of end termina boxes with ACB for the above mentioned rising mains with indicating lamps etc., earthing, connections, as per specifications complete as required. (DSR 3.11)
400 A 30kA SC for 1 sec (DSR 3.11.3)
500 A 35kA SC for 1 sec (DSR 3.11.4)
630 A 50kA SC for 1 sec (DSR 3.11.5)
800 A 50kA SC for 1 sec (DSR 3.11.6)
1000 A 50kA SC for 1 sec (DSR 3.11.7)
SUBHEAD - VIII - CABLE TRAY
Supply and fixing of perforated 2mm thick CRCA sheet steel power coated cable tray of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. including providing and fixing of M.S. painted hanger etc. as required.
150mm wide 50 mm depth (DSR 4.1.2)
300mm wide 62.5mm depth (DSR 4.1.8)
450mm wide 62.5mm depth (DSR 4.1.10)
600mm wide 75mm depth (DSR 4.1.14)
900mm wide 75mm depth (DSR 4.1.15)
SUBHEAD-IX : ELECTRICAL SUB STATION
AUTOMATIC FIRE DETECTION & SUPPRESSION SYSTEM in PANEL (B)
Supply, Installation, Testing & Commissioning of Automatic Direct pressure Release LPCB (LPS 1666) approved System for Electrical Panel application utilising 2.5 LB/ 5 LB/ 10 LB Novec 1230/ FK5-1-12/ FK5-1-12 clean agent for Electrical Panels panels. The tested system must be approved for Enclosed and Ventilated (Natural and Forced Airlflow) Electrical Panels. The cylinder made of mild steel TPED approved along with sturdy metal bracket having direct low pressure dual discharge valve having safety brust disc for over pressurization and ball valve with open and closed option. The DLP valve having push in connector for tube to be connected with double push mechanism. The pressure guage having integrated pressure switch for visual and automatic monitoring of system pressure . The clean agent Novec 1230/ FK5-1-12/ FK5-1-12 to be filled in approved filling plant. The heart of the system linear heat sensing tube made of special polymer red colour 4mm I.D. 6mm O.D. pressurized with Nitrogen to be installed as per the OEM Manual. All the tube fittings to be OEM supplied .The system to be designed,installed and commisioned as per system manual approved by LPCB. The system installer to be trained and certiifed by OEM of the system activation during gas discharge.
5 LB capacity Novec 1230 /FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, 5 LB Novec 1230/FK-5-1-12 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation. Make:-Tracefire/SafeFire/Firetrex (MR)
10 LB capacity Novec 1230 /FK-5-1-12, DLP Assembly with automatic valve, push in connector for tube, 10 LB Novec 1230/FK-5-1-12 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation. Make:-Tracefire/SafeFire/Firetrex (MR)
Linear pneumatic heat Detection Tube with all necessary fittings & supports. (Make: Firetrex/ SafeFire/ Tracefire) (MR)
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational . The control Panel should have provision for integration with fire Alarm /SCAD/BMS System. (MR)
SUB-HEAD - IV : LT CABLES
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . (HSR 31.26)
16 Sq. mm 2 Core Cable . (HSR 31.26 (v) Ard.)
25 Sq. mm 3.5 Core Cable . (HSR 31.26 (xxv) Ard.)
35 Sq. mm 3.5 Core Cable . (HSR 31.26 (xxvi) Ard.)
50 Sq. mm 3.5 Core Cable . (HSR 31.26 (xxvii) Ard.)
70 Sq. mm 3.5 Core Cable . (HSR 31.26 (xxviii) Ard.)
SUB-HEAD -XII- FIRE DETECTION SYSTEM
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required Approved Makes : Edwards /bosch/Seimens Firefinder (DSR 17.2.4)
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. Makes : Edwards / /bosch/Seimens carberus (DSR 17.2.9)
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required Makes : Edwards / bosch/Seimens carberus (DSR 17.2.13)
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. Makes : Edwards / /bosch/Seimens carberus (DSR 17.2.12)
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required (DSR 17.2.5)
MANUAL CALL POINT
Supplying, installation, testing & commissioning of addressable manual call point complete as required Makes : Edwards /bosch/Seimens carberus (DSR 17.2.14)
FAULT ISOLATOR
Supplying, installation, testing & commissioning of fault isolator complete with base as required (DSR 17.2.7)
MONITOR MODULES
Supply , Installation , Testing and Commissioning of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. Makes : Edwards / Notifier /bosch/Seimens Firefinder Approved Makes : Edwards / Wissenschaftler / Rux (MR)
CONTROL MODULES
Supplying, installation, testing & commissioning of addressable fire control module complete as required Makes : Edwards / Notifier /bosch/Seimens Firefinder Approved Makes : Edwards / Wissenschaftler / Rux (DSR 17.2.10)
Supplying, installation, testing & commissioning of addressable phone control module complete as required Makes : Edwards / /bosch/Seimens carberus (DSR 17.2.11)
Hooter cum strobe
Supplying, installation, testing & commissioning of addressable strobe complete as required (DSR 17.2.16)
FIRE ALARM CONTROL PANEL
Ten Loop Panel (DSR 17.2.1.1)
Two Loop Panel (DSR 17.2.1.2)
Supply , Installation , Testing and Commissioning of Addressable Fire Fighter's Telephone Jack with suitable module for two way communication between Remote Fire Fighter & Fire Command Center Approved Makes : Edwards / Wissenschaftler / Rux (DSR 17.2.19)
Supply , Installation , Testing and Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center. Approved Makes :Edwards / bosch/ Scimens carberus (DSR 17.2.17)
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required Makes :Edwards / / bosch/ Scimens carberus (DSR 17.2.18)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required Approved makes : Polycab/ RR Kabel/ Havells (MR)
SUB-HEAD -VII- PA SYSTEM
SPEAKERS
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required Approved Makes : Bosch / Honeywell / Ateis (DSR 17.3.3)
Ceiling Mounted Speakers (a)
Wall Mounted Speakers (b)
PA CONTROLLER
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required (DSR 17.3.1)
DIGITAL AMPLIFIERS
Supply, installing, testing and commissioning of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection Approved Makes : Bosch Praesedio / Honeywell - X618/ Ateis (DSR 17.3.7)
500 Watts
PAGING STATION
Supplying and Laying of 2 core twin twisted 48/0.2 ATC, Multi strand, over all armoured speaker cable as specified in the Tender Specifications Approved makes : Polycab / Falcon / RR Kabel (DSR 17.5.3.2)
SUBHEAD - XIII - LOCAL AREA NETWORK ( LAN )
STRUCTURED CABLING SYSTEM PASSIVE
Supply , Installtion , Testing and Comissioning of armoured 6 core Singlemode OFC cable for interfloor switches connectivity. Approved Make List :- Siemon/Panduit/ Rit (MR)
Supply , Installtion , Testing and Comissioning of 6 port loaded LIU with LC adaptor plates , pigtel cables etc complete as required. Approved Make List :- Siemon/Panduit/Rit (MR)
Supply , Installtion , Testing and Comissioning of 24 port loaded LIU for with LC adaptor plates , pigtel cables for core switch to access switch connectivity over fiber. Approved Make List :- Siemon/Panduit/Rit (MR)
Supply , Installtion , Testing and Comissioning of LC-LC singlemode fiber patch cord for LIU to switch connectivity. Approved Make List :- Siemon/Panduit/Rit (MR)
Supply , Installation , Testing and Commissioning of CAT 6 UTP cable 23 AWG solid copper conductors for Connectivity of Hub room to End Point. Approved Makes: Siemon/Panduit/Rit (MR)
Supply , Installation , Testing and Commissioning of CAT6 information outlet (I/O) for Data, Voice, Camera & Wi-Fi at user end. Approved Makes: Siemon/Panduit/Rit (MR)
Supply , Installation , Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end. Approved Makes: Siemon/Panduit/Rit (MR)
Supply , Installation , Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity. Approved Makes: Siemon/Panduit/Rit (MR)
Supply , Installation , Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity. Approved Makes: Siemon/Panduit/Rit (MR)
Supply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side. Approved Makes: Siemon/Panduit/Rit (MR)
Supply , Installation , Testing and Commissioning of 42 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Each of hardware pkts. Approved Makes: Poweride/MTS/Rittal/APC/APW (MR)
Supply , Installtion , Testing and Comissioning of 15U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Each of hardware pkts. Approved Makes: Poweride/MTS/Rittal/APC/APW (MR)
Supply, Installation, Testing & Commissioning of POE Acess Switch switch Should have min 48 10/100/1000 Gigabit Eathernet min 4 x1G/10G SFP port.Stacking port .Minimum operating temp. 5c to 40c.Must supprop 10 switch stacking .Must have common crieteria certification EA/NDPP or other Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routes from day 1 Approved Make : Cisco/ Juniper / Extreme (MR)
Supply, Installation, Testing & Commissioning of Core Switch Should have Min 48 Port /1G/10G/40G Gigabit Eathernet + 4x 40G Uplink. Operating Temperature 5C to 40C . with switching capacity of 1.4Tbps, forwarding performance of 1Bpps with 32x 1/10G SFP+ ports plus 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, 60K IPv6 routes and 48K IPv6 multicast routes. Should support advance layer 3 (RIPng, OSPF, BGP and MPLS) with 1 year support. Stack Module/40 Gig Optics and all other Cables should be included in Day 1. Approved Make : Cisco/ Juniper / Extreme (MR)
Supply, Installation, Testing & Commissioning of POE Acess Switch switch Should have min 24 10/100/1000 Gigabit Eathernet min 4 x1G/10G SFP port.Stacking port .Minimum operating temp. 5c to 40c.Must supprop 10 switch stacking .Must have common crieteria certification EA/NDPP or other Should support min 2GB internal DRAM, 2GB internal Flash memory,32K MAC address, 1K IPv6 Multicast Routes, Should have static Routes from day 1 Approved Make : Cisco/ Juniper / Extreme (MR)
Supply , Installation , Testing and Commissioning of fiber Modules 1G BASE Approved Make : Cisco/ Juniper / Extreme (MR)
Supply , Installation , Testing and Commissioning of Stacking Cable Approved Make : Cisco/ Impulse / Juniper / Extreme/ Arista (MR)
Wi-Fi SYSTEMS SECURITY
Supply , Installation , Testing and Commissioning of the WLAN solution should have comprehensive integrated security features that include layer 2-7 statefulpacket filtering firewall including for branch and remote offices. AP indoor 3x3 with 802.11 a/b/g/n/ac support and should have disaster recovery mechanism automatically by taking role of controller in terms of controller failure. Approved Make : Cisco/ Juniper / Extreme/ Arista (MR)
Supply , Installation , Testing and Commissioning of Wirelss controller to support Min 512 AP in future , ready to support min 120 AP from from Day1 .Min 2x USB ports , Min 16 K Wirelss client support , Min 4 GB RAM ,Min 32 GB Storage , Same make as switch.WLAN Controller should be Hardware appliance 1U Rack mountable . Approved Make : Cisco/ Juniper / Extreme/ Arista (MR)
Supply , Installation , Testing and Commissioning of Internet Web Security solution with minimum of 500 users from day one with 1 years of subscription / support and flexibility to scale up to 5000 users, having 99.9% uptime with each level redundancy, single pane of glass for reporting with minimum 6 months of logs and must be Leaders in Gartner Magic Quadrant in the last 1 consecutive years (2017) and includes following features as per detailed specification: a) Web Security b) Full SSL Inspection c) Next Generation Firewall d) Sandboxing e) Bandwidth Control f) Cloud Applications Visibility g) Mobility Approved Makes: Zscaler/ Checkpoint/Palo Alto/Cisco/Juniper
SUBHEAD - XIV - IP-PBX SYSTEM
Supply , Installation , Testing and Commissioning of IP Based voice Communication System with 08 Port Voicemail ,08 Port FXS ,08 Port FXO ,3 PRI Trunk lines (30x3Ch) Circuit with CLIP Facility, 907 IP users License ,02 Each IP based Operator Console, 120 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup. Approved Makes: Cisco /Alcatel/ Seimens (MR)
Supply , Installation , Testing and Commissioning of Type -1 IP phone with 1 VoIP accounts, graphical LCD. Approved Makes: Cisco /Alcatel/ Seimens (MR)
Supply , Installation , Testing and Commissioning of Type 2 IP Phone with 2 Voip accounts, 2 Lines , HD Voice,Graphic LCD display with backligh. Approved Makes: Cisco /Alcatel/ Seimens (MR)
SUB-HEAD -XV- IP CCTV SYSTEM
Supply , Installation , Testing and Commissioning of LC-LC singlemode fiber patch cord for LIU to switch connectivity. Approved Make List :- Siemon/Panduit/R & M/ Rit (MR)
Supply , Installation , Testing and Commissioning of CAT 6 UTP cable 23 AWG solid copper conductors for Connectivity of Hub room to End Point. Approved Makes: Siemon/Panduit/R & M/ Rit (NR)
Supply , Installation , Testing and Commissioning of CAT6 information outlet (I/O) for Data, Voice, Camera & Wi-Fi at user end. Approved Makes: Siemon/Panduit/R & M/Rit (MR)
Supply , Installation , Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end. Approved Makes: Siemon/Panduit/R & M/Rit (MR)
Supply , Installation , Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity. Approved Makes: Siemon/Panduit/R & M/Rit (MR)
Supply , Installation , Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity. Approved Makes: Siemon/Panduit/R & M /Rit (MR)
Supply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side. Approved Makes: Belden/Siemon/Panduit/R & M/ Rit (MR)
Supply , Installation , Testing and Commissioning of 2 MP Dome Camera , ONVIF profile S & G ,UL , CE , FCC Certified , 1/2.8" CMOS sensor ,3.to 9 mm varifocal , triple stream ,Min Illumination :0.01 Lux @ (F1.2, AGC ON), 0.028 Lux @(F2.0, AGC ON), 0 Lux with IR , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265 ,H.264 , frame rate 30 fps @ 2 MP ,Approved Makes : Avigilon / Pelco/ Axis/ Sony/ Bosch/ Cisco (MR)
Supply , Installation , Testing and Commissioning of 2 MP Bullet Camera , ONVIF profile S & G ,UL , CE ,FCC Certified , 1/2.8" CMOS sensor ,3 to 9 mm varifocal , triple stream , Min Illumination :0.05 Lux @ (F1.2, AGC ON), 0 Lux with IR , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265 , H.264 , frame rate 30 fps @ 2 MP , Approved Makes : Avigilon / Pelco/ Axis/ Sony/ Bosch/ (MR)
Supply , Installation , Testing and Commissioning of 5 MP Dome/ Bullet Camera , ONVIF profile S & G ,UL , CE , FCC Certified , 1/2.8" CMOS sensor ,3.to 9 mm varifocal , triple stream ,Min Illumination :0.01 Lux @ (F1.2, AGC ON), 0.028 Lux @(F2.0, AGC ON), 0 Lux with IR , Shutter Speed : 1/5 ̴ 1/100,000 s , Edge analytics : line crossing , perimeter intrusion , stationary object ,Video Compression : H.265 ,H.264 , frame rate 30 fps @ 5 MP Edage Analitic, line crossing , perimeter intrusion ,Face detection , cross counting , stationary object ,Inbuilt IR LED , IR distance upto 30 mtrs ,IP 66 , POE . Approved Makes: Avigilon / Pelco/ Axis/ Sony/ Bosch (MR)
Supply, installation, testing and commissioning of 64 Channel NVR upgradable to 128 Channel, H.264 Recording and Playback , Embedded Linux OS, Pre-Installed VMS with licenses,ONVIF profile S & G , Intel Based i7 Processor , 2x4GB, DDR3 RAM , Intel HD Graphics , Throughput Input: 640Mbps / Output: 640Mbps,Decoding Rate Up to 3840 PPS @ D1, 2.5” SATA x 1 (for OS) + 3.5” SATA x 8 ports , e-SATA Port for External Storage Device , RAID 0/1/5/6/10 Support , COM Port RS-232 x1 and RS-485 x 1, USB 3.0 x 2 + USB 2.0 x 3 , Digital Input : TTL-level x 4 , Digital Output : Relay NC/NO x2 (DC24V/1A) , 1 x WAN (10/100/1000 BaseT) , 1 x LAN (10/100/1000 BaseT), 1 x SFP Port (1 Gbps). Approved Makes : Avigilon / Pelco/ Axis/Bosch/Sony (MR)
Supply , Installation , Testing and Commissioning of 6TB Surviellance Hard Disk. Approved Makes: WD /segate /HP (MR)
Supply , Installation , Testing and Commissioning of Full HD 55" LED Professional Display Panel. Approved Makes: Panasonic / LG/ Sony/ Samsung (MR)
Supply , Installation , Testing and Commissioning of 24 port Fabric (SFP) switch with 20 Each of 20 100M/1G SFP Port , 4 Each of GbE RJ45/SFP Combo Port , 4 Each of 1G/10G SFP+ Port ,1 X Console , Switching bandwidth 128 Gbps , 32K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP server. Approved Make : Cisco/ Juniper / Extreme/ Alcatel (MR)
Supply , Installation , Testing and Commissioning of 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE+ ports , 2 Nos of GbE RJ45/SFP Combo Port , 1X console port , Available POE power 370 W , 52 Gbps switching bandwidth , 8K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP feature , Device Management system - topology view , floor view , map view , dashboard , traffic monitoring , cable diagnostics.CE,FCC certified. Approved Make : Cisco/ Impulse / Juniper / Extreme/ Arista (MR)
Supply , Installation , Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit or latest. Approved Makes: HP / DELL / LENOVO (MR)
Supply , Installation , Testing and Commissioning of fiber Modules 1G BASE Approved Make : Cisco / Juniper / Extreme/ Alcatel
SUBHEAD - XVI: ACCESS CONTROL SYSTEM:
Supply ,Installation ,Testing & Commissioning of 4 Door 4 reader access control panel with onboard 32 Bit RISC ARM CPU, 8MB flash memory, shall support up to 100000 card user, 400000 event transactions, TCP/IP, the panel should have inbuilt 4 GB SD memory card to take mirror image of device configuration. data shall support standard Wiegand readers, Access Control panel should have MODBUS connectivity to integrate the panel with BMS (Building Management System), with metal enclosure & inbuilt power supply, facility of din-rail mounting should available. capable to integrate with IP/CCTV & NVR for access event alerts, Inbuilt door interlocking facility, SNMP alerts facility, Low battery and AC fail alert facility & reader Tamper detection alert facility should available. Approved Makes :Cardex / Lenel / Impulse / Bosch / Smart i (MR)
Supply ,Installation ,Testing & Commissioning of 2 Door 2 reader access control panel with onboard 32 Bit RISC ARM CPU, 8MB flash memory, shall support up to 100000 card user, 400000 event transactions, TCP/IP, the panel should have inbuilt 4 GB SD memory card to take mirror image of device configuration. data shall support standard Wiegand readers, Access Control panel should have MODBUS connectivity to integrate the panel with BMS (Building Management System), with metal enclosure & inbuilt power supply, facility of din-rail mounting should available. capable to integrate with IP/CCTV & NVR for access event alerts, Inbuilt door interlocking facility, SNMP alerts facility, Low battery and AC fail alert facility & reader Tamper detection alert facility should available. Approved Makes : Bosch / Smart i/ HID (MR)
Power Supply- Supply, Installation , testing and commissioning of 12 V SMPS DC Power Supply Unit, highly regulated and spikes free terminal voltage and heavy sourcing current for regulated terminal voltage. Approved Makes : Bosch / Smart i/ HID (MR)
Supply & Installation of Cloud Compatible enterprise level Web based Modular Access Management and Time Attendance software with SQL Database and support up to desired number of users. Single GUI Plateform with complete modular software with provision to integrate with different application ie; Access Control, VMS, Alarm Management, etc. Employee Self Service - login module for Employee/HOD/MANAGER where they can view their attendance; they can apply for leave/manual punch/tour entry/outdoor entry though internet with their login ID & password. Same way manager can online approve all application sent by employee. Comprehensive Email and SMS module for to send various SMS & Email on the base of different events in Access Control & Time Attendance system. It should support Multi company, multi location, multi department, multi login with different rights, muti hierarchy of employee, Should support maker & checker facility - the local administrator should able to add the users but he should not able to authenticate/approve the User, Approval right of the added user should be with main Administrator. Dedicated output reports for Payroll integration, Duress Authentications, Email & SMS can be sent on every configured event ie; Leave Application/approval, Manaual Punch Application/Approval,Outdoor Application/Approval, Tour Application/Approval, Condone Application/Approval . Holiday restriction (Reader Wise), Device Configuration – Push/Pull, Dual Authentications, Easy Employee tracking as outdoor Employee Attendance should marked with their GPS Location, Employee can mark Offline attendance (If No Network) through Android Mobile App. Approved Makes :Cardex / Lenel / Impulse / Bosch / Smart i (MR)
Supply ,Installation ,Testing & Commissioning of Mifare smart Card Reader Technical Specs. Approved Makes :Cardex / Lenel / Impulse / Bosch / Smart I (MR)
Read Range -4-9 cms
Data Read CSN/Sector
Type Smart Card (Mifare Classic)
Transmit Frequency 13.56 MHz
Card (Transponder ) Mifare® Series (ISO14443-A)
Card Read Time 0.1 Sec
Output Interface Wiegand Format (32 Bits)
LED Indicator Bi Color LED
Power supply 12V DC @ 100mA
Material Abs Plastic
Card should be read in1 sec
A Wiegand output that easily interfaces with most existing Wiegand protocol access control panels.
Compact and Elegant. Easily installed on walls and doors.
Supply ,Installation ,Testing & Commissioning of Mifare Smart Card Contactless transmission of data and supply energy (No battery needed), Operating Distance: Upto 100mm (Depending on Antenna Geometry), Operating Frequency: 13.56 MHZ. Fast Data Transfer: 106 Kbit/s High Data Integrity: 16 Bit CRC, parity, bit coding, bit counting. 1 Kbyte, organized in 16 sectors with 4 blocks of 16bytes each (one block consists of 16 byte), User definable access conditions for each memory block. Data retention of 10 years. Mutual three pass authentication (ISO/IEC DIS9798-2), Data encryption on RF-Channel with replay attack protection. Individual set of two keys per sector (per application) to support multi-application with key hierarchy. Unique serial number for each device. Transport key protects access to EEPROM on chip delivery. Approved Makes :Cardex / Lenel / Impulse / Bosch / Smart i (MR)
Supply ,Installation ,Testing & Commissioning of Electromagnetic Lock 600 lbs, Single leaf, LED Status Display, Approved Makes :Cardex / Lenel / Impulse / Bosch / Smart I (MR)
Supply ,Installation ,Testing & Commissioning of Electromagnetic Lock 1200 lbs, double leaf, LED Status Display, Approved Makes :Cardex / Lenel / Impulse / Bosch / Smart I (MR)
Supply , Installation , Testing and commissioning of CAT 6 UTP cable 23 AWG solid copper conductors. Approved Makes: Siemon / Panduit / R & M/ Rit (MR)
Supply and Laying of 8 Core x 1.0 sq mm multi strand, copper, unarmoured shielded Cable as per specification (between the every card readers & the access controllers) Approved Makes : Polycab / RRKable / CMI / Paramount (MR)
Supply ,Installation ,Testing & Commissioning of U/L Clamp made of aluminium anodised for EM Lock. Approved Makes : Impulse / Bosch / Smart I / HID (MR)
Supply , Installation , Testing and commissioning of Exit push button as required. Approved Makes :Cardex / Lenel / Impulse / Bosch / Smart I (MR)
Supply & laying of Supply and drawing of 2 C X 1.5 Sq mm multi stranded twisted unshielded FRLS Copper cable for Access control system. Approved Makes : Polycab / RR Kabel / Havells (MR)
SUBHEAD - XVII : OXYGEN GAS SYSTEM
Fully automatic Oxygen Controls control panel(flow 1200 lpm) (MR)
SITC of fully Automatic pneumatically operated oxygen control panel. Visual indication of the manifold is provided by 3 guages within control panel, Indicating Pressure of the right & Left hand bank and the supply pressure from control panel to distribution system with sensing faciliteies to provide visual signals na other anciliary services such as heaters. Pannel should be fitted with audio alarm indication for changeover of empty cylinder. The entire manifold will be hydraulically tested at 130 Kg/Cm2 pressure, duly degreased foroxygen Service, and supplied in sealed cover, ready for assembly at site etc. complete as required. (Note : Excluding Supply of cylinder.)
Oxygen Manifold - 2 banks x 15 cylinders. (MR)
SITC of oxygen manifold of Size (15 working + 15 Standby) for Indian type bulk cylinders, high pressure copper annealed tail pipes complete with middle frame, chains for individual bulk oxygen cylinder, NRV's and 40 Each pig tail pipes. it should be suitable to withstand a working pressure of 145 kg/cm2 and should be tested at 300 kg/cm2. etc. complete as required.
Oxygen Manifold (Emergency) - 2 banksx 6 cylinder (MR)
SITC of oxygen manifold of Size (6 working + 6 Standby) for Indian type bulk cylinders, high pressure copper annealed tail pipes complete with middle frame, chains for individual bulk oxygen cylinder, NRV's and 12 Each pig tail pipes. it should be suitable to withstand a working pressure of 130 kg/cm2 and should be tested at 300 kg/cm2. etc. complete as required.
Gas Outlets with probes - Oxygen (MR)
SITC for Oxygen Outlets as Per standards, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate etc. complete as required.
Oxygen Flow meters (MR)
SITC for Oxygen flowmeter complete with humidifier bottle, The flow meter must be constructed with chromium plated brass body, extremely robust, to take care of the day to day usage demand. Flow meter cartridge type knob : easy to maintain, offers optimum adjustment quality and superior designing and engineering to provide high level of accuracy, with no significant affect from restrictions caused by down-stream equipments. The flow meters should be 0-15 LPM range for oxygen. etc complete as required.
NITROUS OXIDE SYSTEM
Fully automatic Nitrous Oxide Controls(500lpm) (MR)
SITC for Fully Automatic pneumatically operated N2O control panel. With heater, The entire manifold will be hydraulically tested at 250 Kg/Cm2 pressure, duly degreased , etc complete as required.
N2O Manifold - 2 banks X 6 Cylinder (MR)
SITC for (4 working + 4 Standby) size of N2O manifold complete with middle frame, chains, NRV's 8 Each pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Nitrous Oxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc. complete as required.
Nitrous oxide manifold - Emergency 2 Banks X 3 Cylinders (MR)
SITC for (2 working + 2 Standby) size of N2O manifold complete with middle frame, chains, NRV's 4 Each pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Nitrous Oxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc. complete as required.
Gas Outlets with probes - Nitrous Oxide (MR)
SITC for Nitrous Oxide outlets as Per standards, Terminal units shall be capable of single- handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc. complete as required.
CARBON DIOXIDE SYSTEM
Fully auto CO2 Controls (50lpm) (MR)
SITC for Fully Automatic pneumatically operated CO2 control panel. With heater, The entire manifold will be hydraulically tested at 250 Kg/Cm2 pressure, duly degreased , etc complete as required.
CO2 Manifold - 2 banks X 2Cylinders (MR)
SITC for (2 working + 2 Standby) size of CO2 manifold complete with middle frame, chains, NRV's 4 Each pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Carbon dioxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc. complete as required.
CO2 Manifold (Emergency) - 2 banks x 1 cyl (MR)
SITC for (1 working + 1 Standby) size of CO2 manifold complete with middle frame, chains, NRV's 2 Each pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Carbon dioxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc. complete as required.
Gas Outlets with probes - CO2 (MR)
SITC for Carbon diaoxide outlets as Per HTM 2022,Terminal units shall be capable of single- handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc. complete as required.
Triplex Compressed Air System: 5000 LPM (MR)
SITC for TRIPLEX Compressed air system complete with oil free air compressor (3 Each x 80 cfm) equipped with air receiver capacity of 3000 ltrs. And complete with Air Dryer of 75 cfm. It should be consist of oil-less, stationery air cooled silenced (Reciprocating) air compressor. It should be equipped with three electrical motors, one Air reservoir Tank, Air filters, Pressure Regulator-cum-filter, Air Dryer with moisture separator. Interconnecting pipes with necessary valves and fittings thereof. etc. complete as required.
Gas Outlets with probes - Medical Air ( 4 Bar) (MR)
SITC for Compressed M.Air- 4 Bar outlets as Per standards , Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc. complete as required.
Gas Outlets with probes - Surgical Air (7 Bar)
SITC for Compressed M.Air- 7 Bar outlets as Per HTM 2022/ NFPA, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc. complete as required. (MR)
Quadruplex Vacuum System: 7000 LPM , -450 Hg, (MR)
SITC for QUADRUPLEX Vacuum Central system complete with Vaccum pumps (4 Nos X 10 HP) Model - 15V each pump should be reciproting base frame mounted with motor and 1 No 4000 ltrs. Capacity vacuum reservoir, The Vaccum System should include three medical Vaccum pumps each with electrical motors, silencers, bacteria filters They should be capable of removing more than 99.9% of oil and smoke particles from the exhaust. etc. complete as required.
Outlets with probes - Vacuum (MR)
SITC for Vacuum outlets as per standards, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc. complete as required.
Ward Vacuum with regulator and jar (600 Ml) (MR)
Theater Suction jars with regulator (theatres,2*2000 ml) (MR)
Copper pipe:
SITC for Medical Grade copper pipe with required copper fittings, All pipes shall be drawn half hard temp., solid drawn, seamless, phosphorous deoxidised, non-arsenic and degreased copper pipe conforming to EN 1057:1996 (originally BS 2871-1971 Part 1 (Table X) and chemical composition as per BS-6017 of 1981 table 2, The supplies of copper pipe would be accompanied with manufacturers test certificate for the physical properties of copper pipes and their Chemical composition. The supply of pipes be further substantiated with inspection certificate from the third party like SGS/Lloyds Register. etc. complete as required.
Zonal Valve Service ( Valves with Box)
1gas+1Vac (MR)
2gas+1Vac (MR)
3gas+1Vac (MR)
4gas+1Vac (MR)
5gas+1Vac (MR)
Isolation Valve service
12 mm dia (MR)
15 mm dia (MR)
22 mm dia (MR)
28 mm dia (MR)
42 mm dia (MR)
54 mm dia (MR)
76 mm dia (MR)
Master Alarm service ( Digital ), post source (MR)
Area Alarm service ( Digital)
2 Gas ( 1 O2 + 1 Vac) (MR)
3 Gas ( 1 O2 + 1 Vac + 1 MA4) (MR)
4 Gas ( 1 O2 + 1 Vac + 1 MA4 + 1 n2o) (MR)
5 Gas ( 1 O2 + 1 Vac + 1 N2O + 1 CO2 + 1 SA7) (MR)
6 Gas ( 1 O2 + 1 Vac + 1 N2O + 1 CO2 + 1 SA7 + 1 ma4) (MR)
Antistatic Hose
High Pressure Antistatic Hose (MR)
Low pressure Antistatic Hose (MR)
Bed Head Panels (Size - 1500 X 300 X 110 mm)
SITC for pure extruded aluminium made with powder coat finish, having 5 Nos gas outlets, 2 Nos electric panels having 4 nos of 6/16 Amp switches and 4 Nos of electrical sockets ( 6/16 Amp) Make - Legrand or similer type, Provision for Nurse call display, SS IV pole with holder and utility basket etc. (MR)
Single arm OT pendant
SITC for Single arm swiveling pendant having 2 Nos of O2, 2 Nos of VAC, 1 No of Nitrous oxide, I No of medical air (4 Bar), 1 No Surgical Air (7 Bar)and 1 No of CO2 gas outlet points, 6 Nos of electrical switch and sockets( Legrand, 6/16 Amp). The pendant should have 2 Nos of IV poles ( SS 304) and 2 Nos of Monitor selves. (MR)
Kit conversion for Nitrous Oxide (MR)
Kit conversion for Oxygen (MR)
Combined electric control panel for Air compressor and Vacuum pumps
SUBHEAD - XVIII : MODULAR OT
Supply, Installation, Testing and commissioning of Wall & Ceiling Panels System for Modular Operation Theatre designed and constructed for exact size, easy field installation with a height of 3 mtrs. The pre fabricated OT should be free standing structure constructed from puff insulated Stainless Steel Panels. These panels are produced in double band laminator in which Stainless steel sheets of thickness of 0.80-1.0 mm is used on bothe sides. The core should consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3 .The construction shall be of single wall type. The Total thickness of Panels is 60mm. Sprayed with Antibacterial & Antifungal Paint to thickness of 300 microns Preferred make of Steel -Tata/Jindal/SAIL. All cablings within the Walls has to be supported by PVC conduits..Wall and Ceiling Panel System should be CE certified and in compliance under Class 1 Medical device (MR)
Ceiling Panel System using SS Puff Panels with Antibacterial Paint
Supply, Installation, Testing and commissioning of Ceiling Panels System for Modular Operation Theatre designed and constructed for exact size, easy field installation with a height of 3 mtrs. The pre fabricated OT should be free standing structure constructed from puff insulated Stainless Steel Panels. These panels are produced in double band laminator in which Stainless steel sheets of thickness of 0.80-1.0 mm is used on bothe sides. The core should consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3 .The construction shall be of single wall type. The Total thickness of Panels is 60mm. Sprayed with Antibacterial & Antifungal Paint to thickness of 300 microns Preferred make of Steel -Tata/Jindal/SAIL. All cablings within the Walls has to be supported by PVC conduits.Ceiling Panel System should be CE certified and in compliance under Class 1 Medical device (MR)
LAMINAR AIR FLOW SYSTEM WITH MINI PLEAT FILTERS
Supply, Installation, Testing and commissioning of LAMINAR AIR FLOW SYSTEM of size ( 2400 x 2400 mm) . The laminar should be constructed with Aluminium sheet Laminar system will introduce the highest air quality into the operation theatre. Air should be diffused into the room uniformly over the total area through perforated alumnium grills. .The air diffusers should be installed in a manner which allows them to be removed for easy maintenance of air filter. HEPA filters of H14 Grade 99.97% efficiency are used to ensure high quality clean air is supplied and under tight control of bacteria infection system. Laminar System should be CE certified and in compliance under Class 1 Medical devices/Equivalent . (2400mmx2400mm) (MR)
DIMMABLE PERIPHERAL LED LIGHTS
Supply, Installation, Testing and commissioning of PERIPHERAL LIGHTS (MR)
* Recess mounted luminaire with screwless design for easy maintenance
* Digital ballast with dimmer control
* Non-yellowing clear acrylic diffuser is sealed with bottom frame and specially design sealant to ensure dust proof
* Pre-anodized high purity specular finish aluminium reflector for precise light distribution
AUTOMATIC HERMETICALLY SEALED SLIDING DOOR
AUTOMATIC SLIDING DOOR IN HPL LAMINATE . Door Size - 1800 (W.) x 2100 (H.) mm WITH TOUCHLESS SENSOR , FOOT SWITCH. (MR)
AUTOMATIC SLIDING DOOR IN HPL LAMINATE . Door Size - 1000 (W.) x 2100 (H.) mm WITH TOUCHLESS SENSOR , FOOT SWITCH. (MR)
*The Door leaf made of extruded aluminium profiles . The door leaf panel should be finished in HPL .The Door Panel should not have any vertical joints on both sides. **For smooth sliding the door moves on nylon wheels within an single piece aluminium extruded track. The Door leaf will have one view window of size 500 x 700mm . Door controller should be microprocessor based electronic automation unit (CE Marked) for controlling door movement, the acceleration and speed of the door. Features such as full opening, half opening,permanent opening .It includes photocell for user's safety .Door opening and closing should be through Touchless Hand Sensor & Foot Switch .In case of power failure door shoould be manually openable. Automatic Door should be CE certified and in compliance under Class 1 Medical device /Equivalent .
SURGEON CONTROL PANEL
Supply, Installation, Testing and commissioning of TOUCHSCREEN OPERATING ROOM CONTROL PANEL (CE MARKED ) (MR)
* Time Elapsed Clock
* Time Day Clock
* Hands free telephone
* Medical Gas Alarm - 5 service with audio visual alarm with sensors
* Temp & Humidity display with controlling and sensors
* Peripheral Lighting On/Off with dimming control
* HEPA Filter status with alarm
TWO PLATE LED XRAY - DIMMABLE
Supply, Installation, Testing and Commissioning of Two Plate dimmable X-Ray viewing screen designed to provide a high level of control luminance without flicker. The dimming range should be from 3-100% . The Xray should have inbuilt sensor for Xray film . On/Off and dimming operation should be through integrated PCB. TWO PLATE XRAY should be CE certified and in compliance under Class 1 Medical devices /Equivalent . (MR)
PRESSURE RELIEF DAMPER
Supply and Installation and Commissioning of proper Pressure Relief Dampers having multi 304 graded stainless steel blades for maintaining the positive pressure inside the operation theatre PRESSURE RELIEF DAMPER should be CE certified /Equivalent . (MR)
CONDUCTIVE FLOORING WITH SELF LEVELLING
Supply and Installation and Commissioning of 2.00 mm thick CONDUCTIVE ESD tiles /roll as per EN 427.(Imported) The tiles/roll are manufactured from PVC chips coated with a conductive substance. The tiles/roll will offer guarantee a longlife conductivity independently from humidity and temperature. Tiles/roll should be highly compressed with a compact surface. These conductive tiles /roll should be completly free from volatile antistatic chemicals, and ensures a permanent and stable conductive performance of the floor over its entire life time. The welding / seaming shall be done using hot air welding machine. The Electrical Resistance offered by the tiles is as per IEC 61340-4-1, EN 1081(100v) ANSI/ESD 7.1. The laying of Copper tape and conductive addhesive has to be laid before the tiles are laid. (MR)
LIST BOARD
Supply and Installation ,Testing and commissioning of OPERATING WRITING LIST BOARD made out of Toughened Glass in 10mm thickness of size (948mm x 648mm) (MR)
HATCH BOX FOR DIRTY LINEN
Supply and Installation and Commissioning of HATCH BOX made out of Stainless Steel SS 304 grade for dispoasl of dirty linen /waste.Each Hatch will be equipped with two doors and the door will be operated electronically .The Hatch will be designed in such a way that only one door will be opened at one time.The UV light wiil be so installed that it is kept on while both the doors are closed ,this UV light has to be automatically turned off in case of opening of either of the doors. There shall be indicators on both sides of the OT so that door open/close status can be monitored from both ends.HATCH BOX should be CE certified and in compliance under Class 1 Medical devices /Equivalent . (MR)
PENDANTS - ANESTHESIA (Imported )
Supply and Installation and Commissioning of 'SINGLE ARM PENDANTS for Anesthesia (CE Marked) : Single Arm Pendant will have 1000mm arms with motorized Horizontal movement having load carrying capacity of 200kgs. The arm will be rotated upto 330degree to 340 degree . The Pendant will have electro magnetic brakes system which will be adaptable to variuos safety requirements and construction faciliteis. Brake indicators "Brake Guide" should be available with visual feedback (LED illumination). Anesthesia Pendant will have 1 arm with shelves as per points :- 1) 5/15 Amp Electrical sockets without switches - 8 to 10 Each, 2) shelfs with side rails - 4 Each with 1 drawer 3) Gas interface set for interface plate - 1 no., 4) Interface plate with electrical fittings- 1no. 5) Provision to fix 6 Nos Gas Outlets. (MR)
PENDANTS - SURGEON (Imported )
Supply and Installation and Commissioning of DOUBLE ARM PENDANTS for Surgeons ( CE Marked) : Double Arm Pendant will have (1000mm + 800mm) arms with Horizontal movement having load carrying capacity of 200kgs. The arm will be rotated upto340 degree . The Pendant will have electro magnetic brakes system which will be adaptable to variuos safety requirements and construction faciliteis. Brake indicators "Brake Guide" should be available with visual feedback (LED illumination). Surgeon Pendant will have 2 arms with shelves as per points :- 1) 5/15 Amp Electrical sockets without switches - 8 to 10 Each, 2) shelfs with side rails - 4 Each with 1 drawer 3) Gas interface set for interface plate - 1 no., 4) Interface plate with electrical fittings- 1no. 5) Provision to fix 6 Nos Gas Outlets. (MR)
OT LIGHT (Imported )
Supply and installation of OT light .160000x160000 LUX (MR)
VIEW WINDOW
Supply, Installation, Testing and commissioning of VIEW WINDOW with 6mm toughened glass on both sides. Motorized Blinds of reputed make sandwiched in both glasses . The window will be recessed into wall. View Window size : 1800 x 1500 mm. View Window should be CE certified and in compliance under Class 1 Medical device (MR)
ELECTRICAL CONDUITING & WIRRING INSIDE OT
Supply, Installation, Testing and commissioning of ELECTRICAL CONDUITING AND WIRRING INSIDE OT . All wires should run within PVC conduits of 25mm size . Electrical distribution board complete with all accessories. Internal wiring with FRLS wires of reputed brands such as Bonton /finolex etc ,Wires will be of size 2.5Sqmm,4sq.and 6sqmm..Electrical Switchsockets of 6/16amp of approved make min 4 nos on each walls. (MR)
Storage Unit
Supply and Installation of Storage unit as per specifications (MR)
SCRUB SINK
"The Scrub Sink should be made of 1.5mm thick Stainless Steel SS 304 grade . The scrub sink should be""provided with a front access panel which should be easily removed for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation should include infra-red sensors with built-in range of adjustment.""Thermostatic mixing, valve control should be located behind the access panel and maintain constant" "water temperature." "User defined time 1, 3,5,10 min. are available. This timing should be adjustable to meet individual"application requirements, provided with infrared sensors, thermostatic control taps with fail-safe temperature controls.""All units should have reduced anti splash front. It should have manual foot and operation mode. The station should also have inbuilt soap dispensers. (MR)
UPS UPS load per OT should be provided minimum 10 KVA with one 10 KVA backup for all OTs and reduntancy( n+1) should switch automatically. The battery bank may be common for UPS. For eg. there are 8 MOT, the USP should be 10KVAx8 and one 10 KVA as standby for all OTs. As per the specification (MR)
Aluminimum grill for return air approx Size- 300 x 450mm complete set (MR)
SUBHEAD - XIX : HIS, PFM & WEB PORTAL
HOSPITAL MANAGEMENT SYSTEM
Electronic Registration System with HIS Module for patient management/OPD which can expend from registration to other required module, including required Servers/Registration Workstation,Printer and other H/w equipments etc all complete.Apporved Make:- Wipro Limited, TCS, Tenwave Infotech Pvt Ltd (ETHER) (MR)
Patient Flow Management (EPFM)
SITC of Electronic Patient Flow Management (ePFM) Application as following specification. Make: Wipro/Inter system/ Tenwave /Q-nomy Inc (MR)
SITC of Integration with Electronic Management System ‘s Appointment module based on Mobile/Web Portal as per following specification. Make: Wipro/Inter system/ Tenwave /Q-nomy Inc (MR)
SITC of Server – Xeon Processor (quad core) with 16 GB channel DDR4 SDRAM memory, 1TB HDD , Integrated Intel® i219- V Ethernet LAN 10/100/1000; Make: DELL/ HP (MR)
SITC of full HD 55” LED smart T.V for Receptions Make: Sony, Samsung, Panasonic, LG (MR)
SITC of full HD 40” LED smart T.V for OPD Lobby Make: Sony, Samsung, Panasonic, LG (MR)
SITC of Small footprint. 18” Colored LED/LCD Display for Counters (MR)
SITC of 18" touch screen self-service Kiosks with Floor mounted/ePFM Kiosk , Thermal Printer with auto-cutter (80 mm X 58 mm) and required interfaces & power supply. Make: Wipro/ Inter System/ Tenware/ Q-Nomy (MR)
WEB PORTAL
SITC of Web Portal Development and Installation for Patient Management as following specification. Make: Wipro/ Tenwave/Inter system/ TCS (MR)
SITC of Mobile App ( Android and IOS Support) as per following specification. Make: Wipro/ Tenwave/Inter system/TCS (MR)
SITC of Integration with Electronic Management System as per following specification. (MR)
Technical Specification
2.1 Web Portal
· Provide secure portal accounts for patients
· Pre registration to entered demographic details and it should be available to the hospital registration staff when the patient visits the facility.
· Provide the Patient Registration online option
· View the medical records of the existing patients of the hospital.
· To book, reschedule and cancel appointments
· To view the past visit history
· To view active medications
· To view lab results and history.
· To make payment of registration ,tests, Student fees etc. throgh payment gate way.
2.2 Mobile App
· Provide Appointment booking/Rescheduling
· Provide the Laboratory Report download option
· Provide the Document Upload Option
· Provide On line payment option
· Mobile Application will be developed considering easy to use.
· Mobile Application flow shall be patient centric and provide user to maintain the full family record using single login.
· Mobile application will be provide the OTP /Password based login.
· Mobile based (compatible with iOS and Android) solution and Web Portal will be supported with Single application Server.
Healthcare Patient Engagement Solutions shall also be linked with Electronic Management System’s to fetch the Doctor Schedule, Appointment, Lab Reports etc.
· To make payment of registration ,tests, Student fees etc. throgh payment gate way.
SUBHEAD - XX : PNEUMATIC TUBE SYSTEM
SITC of Central controller with all hardware as per specs, zone controller and software, including statistic functions and user license as per specs (MR)
Stations (MR)
DST Trough Station (MR)
Multi Receive Station (MR)
Multi Send Station (MR)
Carrier receive Basket (MR)
Empty Carrier rack (MR)
Carriers – (MR)
3- way - DIVERTER 160 (MR)
Blower with all accessories - BLOWER SU8 noch anpasse (MR)
Tubes with clamps, support structure and all accessories (MR)
Communication and Low Voltage wiring with adapters, boosters and all accessories (MR)
Approved Make: SUMETZBERGER, AEROCON & LAMSON
SUBHEAD - XXI : UPS SYSTEM
Supply, unloading, installation , testing & commissiong of micro processor / DSP controlled 80 KVA, IGBT based rectifier to achieve THDI <3% and input power factor 0.99 at 50%-100% loading, Built-in Delta Star Isolation Transformer at inverter output before static switch, True Online Double Conversion (VFI as per IEC 62040-3) UPS using PWM IGBT technology , 3 Phase input and 3 phase 415 V output UPS system; and each comprising of the following:
100% rated Inbuilt static switch at the invertor output . 100% rated Inbuilt static switches at the static bypass line.
100% rated Inbuilt Maintenance Bypass.
Built-in Phase sequence protector & corrector ( UPS should not go on bypass/battery bank if the phase are reveresd) & Back feed Protection
Voltage Distotion - <1% on linear & <3% on Non linear load
Input Voltage Range- +/- 20%
Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments.
Supplying, unloading, installing , testing and commissioning of Lead Acid sealed maintenance free 12V, batteries for 80 KVA ystem, for providing 10-15 minutes backup to 80 KVA UPS The bank of batteries shall comprise required Nos of batteries. 12V/150AH/40 Nos
Supply, unloading, installation,testing & commissioning of matching cabinet/open racks to house SMF batteries for 80 KVA UPS system along with interconnecting links, MCCB etc. complete as required & as per specifications. (MR)
SUBHEAD - XXII :COLD ROOM WORKS FOR MORTUARY AND AUTOPSY
Supply ,Installation,Testing & Commissioning of cold storage facility with refrigeration units along with 60mm thick Poly Urethene Foam (PUF) panels inside the pre constructed stone masonary with RCC roof finished room ,to operate in temperature range +2 degre celcius to +8 degree celcius ,with design at ambient temperature of 43 degree celcius, with external dimensions of cold room as (2 NO IN AUTOPSY AND 1 NO IN MORTURY) , as per tender specifications: (MR)
PUF PANEL STRUCTURE
The walls and ceiling panel should be fabricated from 0.40 mm thick sheet with inner and outer finish of Pre Painted GI sheet having PUF thickness of 60mm.
Supply and installation of 60 mm thick Aluminium Cheq sheet with Marine Ply Floor for flooring inside Walk-in-Cold Room.
Supply & installation of 1 No. flush door with clear opening of 34" x 78" ,made of 60 mm PUF panel, inner & outer with Pre Painted GI. There should be high quality cam lock with metal plunger, hinges & handle on the door for automatic closure of the door with out any manual push.
1 number of Vapour proof LED light fittings with suitable switching and wiring in casing caping is inclusive .
All accessories required for installation of cold room facility is inclusive .
REFRIGERATION UNITS
Supply ,Installation,Testing & Commissioning refrigeration unit with hermetic Scroll Compressor is to be installed with 20,000 BTU/Hr capacity @ +4 deg C room temperature and +35 deg C ambient temperature to be operated on 440V, 3 ph, 50 HZ power supply with one no of machine as Standby with copper piping of manufacture recommended size and insulation . (MR)
APPROVED MAKES: BLUE STAR, VOLTAS, DAIKIN,
PUF PANEL : BLUE STAR/KOLPACK/VOLTAS/LLYODS.
EVAPORATING UNIT: BLUE STAR/ KOLPACK/BOHN/LLYODS/VOLTAS
CONDENSING UNIT: BLUE STAR/ KOLPACK/BOCK/VOLTAS/LLYODS
The Manufacturer should have inhouse facility of both PUF Panel and Refrigeration Units.
SUBHEAD - XXIII : Integrated Building Management System (IBMS)
Supply,Installation,testing and commissioning of IBMS & allied works as detailed below and as per specifications:
(approved vendors:Siemens/Honeywell/Schneider/Tridium/ EASYIO-JOHNSON)
Central Works Station :
Intel Pentium IV machine with 2.4 GHz speed, 16 GB RAM 160 GB HDD, Multimedia extenal modem as per specifications this should be server base suitable for data points as required
Colour Monitor SVGA - 22 inch
132 column 240 CPS printer (Alarm and report)
Mouse
UPS with 20 minutes battery backup
Software and System Interface Units :
Supply,Installation,testing and commissioning of the following Web Based software with built in protocols MODBUS/ BACNET/KNX/ OBIX/ SNMP-LON for BAS as per specifications. Developing,testing and commissioning of the software for the building automation system along with unlimited user license.
Providing all necessary software and hardware for the interface of the following system/equipment including providing necessary integrators/modules (RS-232/ RS-485modbus Bacnet/Lonworks output to be provided by other vendors)
Chilling Machines
DG sets (2no. 500 KVA + 3 Nos 1010 KVA)
Electric Pump
UPS system
LT -ACV Breakers
Lifts
Diesel Pump
Jocky Pump
Primary Pump
Secondary Pump with VFD
Condensor Pump
Transformer (2500 KVA)
Cooling Tower
Supply,Installation,testing and commissioning of Web
based energy auditing softwarware for data management
and analysis should have pre-designed reports ,accessible
from anywhere via an internet browser and able to seamlessly
integrate into the building automation system
Supply,Installation,testing and commissioning of
following controllers as per the specifications:
Standalone intelligent with built in protocols MODBUS/ BACNET/KNX/ OBIX/ SNMP-LON controllers with
32 bit microprocessor, real time clock and EEPROM as
per the specifications. The controller shall be housed in
a vandal proof, lockable and secure MS cabinets to be
supplied along with controllers.
Web Based system interface modules consisting of gateways,
other interface units as required as per specifications. The units
shall be housed in vandal proof lockable and secure wall mounted
MS cabinets to be supplied along with the controllers.
Hand Held Portable Operator Terminals / TABLET
Sensors and Field Devices
Supply,Installation,testing and commissioning of the following sensors/transmitters/transducers/ field devices as per the specifications
Immersion type temperaure sensors for measuring chilled water supply and return temperature in the Range 32F-160F
Duct type temperauture sensor for measuring supply air temperature at the AHUs of the (Range 45F-150F)
Out side air temperature and RH sensor for measuring the outside air temperature (35F-130F) and humidity
Pressure transmitter for measuring pressure in water supply and return headers (0-10Kg/m2)
Electromagnetic type flow meters for following chilled/hot water supply and return main header
600 mm dia pipe
450mm dia pipe
150mm dia pipe
Differential Pressure switch across the Air Handling Units indicating the filter status (pressure differential 2mm-15mm)
Differential Pressure switch across the AHU/Fan sections for indicating the fan status of pessure differential range 10mm-50mm.
Level switches for indicating water levels in sumps and tanks.
Differential Pressure switch for pumps status
Room Temperature + RH Sensor
Flame Proof Level Switches for DG Tanks
Modulating typer Damper Actuators - 5 Nm
CO2 Sensors
Occupancy Sensor for controlling of VAV Boxes
Supply,Installation,testing and commissioning of
the following Variable Frequency Drives for the Air
Handling Units and Cooling Towers as per specificationsIP/ RS 485 Protocol for seamless integration with IBMS-
15.0-20 HP motor
12.5 HP motor
10 HP motors
7.5 HP motors
5 HP motor
3 HP motor
(Approved Vendors : Danfoss/ABB/Siemens)
VAV Boxes
SUPPLY, Installation,TESTING & COMMISSIONING OF Variable Air Volume Boxes
VAVs shall be pressure independent type & low velocity type, cooling only
VAV Boxes shall be slow reacting type capable of delivering variable air
volume type by the action of opposed bade dampers.These shall be supplied
with end flanges for attachment to flanged duct ends and shall have internal
accoustic treatment shall be in double skin GSS construction and completely
sealed, easily removable. The access shall be provided in the bottom side only.
VAV shall be electronically controlled networkable controller type complete with
low leakage damper actuator,microprocessor unit,wall/ceiling mounted
temperature sensor with on/off switch control transformer unit handler bracket
VAV Boxes shall also be able to reset any air flow between zero and the max.
air quantity that the boxes can handle without changing orifices or other parts
Each VAV Shall be supplied with one operating switch in the related rooms,
which shall chnge the temperature setpoint of VAV including cost of wall switch.
The quoted price shall be inclusive of the temperature sensor for each VAV unit
& associated internal cable required for proper functioning of the VAV Boxes.
The temperature sensor and the entire control mechanism shall be fully
campatible with IBMS.Data like temperature,setpoint and damper position shall
be monitored thru IBMS system with Bacnet / Modbus IP protocol-
The capacities of the units as per specification are as follows
Differential Pressure Sensor
(Approved Vendors: Trox/Balcolair/Titus/Belimo)
Ventury Valves
Supply,Installation,testing and commissioning of
venturi valves based airflow as per air flows as mentioned
below.The system shall comprise of one supply and one
exhaust valve operating as tracking pair.The valves shall
have provision to communicate to IBMS over bacnet/lon/ Modbus IP
protocol.The valve shall control the airflow within 5% of desired
air flow The valve shall also monitor and control the temperature
as set from the room unit.To maintain a comfortable temp in the
room without compromising the air flow requirement of the room
The capacities of the units shall be as follows .
The room display shall provide to display the supply and
exhaust air in the room and also allow the change to offset
in the supply and exhaust air flow.The display shall also display
the temperature in the room.
1000-1200 cfm (for isolation ward)
3000 cfm (for Opration Theatre)
(Approved Vendors:Phoenix Control/Siemens/Honeywell)
Cable & Conduits
Supply,Installation,testing and commissioning of
the following cables as per specifications :
Signal cable ( 2 x 1.5 Sq. MM., stranded tinned
Cu conductor, flexible, PVC sheathed type
Communication cable ( 2 x 1.5 Sq. MM., stranded
tinned Cu conductor, flexible, PVC sheathed, Shielded type
Conduits :
Supply,Installation,testing and commissioning of
the following conduits for running cables as per specifications :
M.S. Conduit for signal cable (25 mm)
M.S. Conduit for communication cable ( 20 mm)
GS Trunking
Supply,Installation,testing and commissioning of
2 mm thick galvanised steel trunking of the following
complete with angle iron support/hangers etc. as per
the specifications.
SUBHEAD - XXIV : NURSE CALLING SYSTEM
Supply, Installation & commisioning of Head Nurse control panel as a central management : The all patient Bed or Nurse Station shall be connected to Head Nurse control panel central management system at Head Nurse office. The control panel shall comprises of touch screen LC colour graphic display for displaying all details such as call queue system , priority systems for emergency calls , texting between the panel , call orientation -Night service mode to redirect calls to another panel. The system shall able to build a priority depending on the call type and display them on monitor. All calls ,emergency calls , toilet-bathroom and visiting nurses, can be tracked on the panel and remote access. The system shall display the exact location of the calls. The system shll have facility to connect with smart phones so that one can track calls on their smart phone and even make Voip calls. Make:-Rauland borge/Ge/Hampton (MR)
Supply, Installation & commisioning of Nurse Station Terminal : Nurse Station shall comprises of touch screen LC colour graphic display for displaying all details , Querying receiver for speaking discretely, Microphone and loudspeaker for hands-free speech (incl. volume control), full duplex speaker phone in brilliant sound quality & inbuilt microphone . The Nurse station shall be able to communicate to room , other nurse station. The Nurse station shall have access to patient information , in case of emergency shall have facility to jump as many calls to other Nurse station.. All call indications follow the priority and must display the exact location of the calls. The system shall be able to configure with N number of bed for nurse station. In case of limitation for configuration , the system or its combination of system unit shall be able to configure atleast 40bed in any scenerio . The system shall be self sufficient to share data to central Nurse management station. Make:-Rauland borge/Ge/Hampton (MR)
Supply, Installation & commisioning of Room Control Terminal/Mini Nurse station : Room Control Terminal/Mini Nurse station shall comprises of touch screen LC colour graphic display for displaying all details (Active /offline call). The system shall able to do internal & external call or conference call , full duplex speaker phone in brilliant sound quality & inbuilt microphone . The Room control terminal / Mini Nurse station shall be able to communicate to own or other nurse station, hospital stff , code blue and other custom emergency codes through an on screen menu. Patient information from HIS (Hospital information system ) can be monitored on the server system through the corresponding bed icon on screen. If desired the information about the patient can be edited through the touchscreen. The system shall be self sufficient to share data to central Nurse management station. Make:-Rauland borge/Ge/Hampton (MR)
Supply Installation Testing & Commissioning of LED Indicators Module at Outside of each ward with ecofriendly Leds . It shall warn with three main colour red , green , blue, and combinations of these depending on the call status of the room complete as required. Make:-Rauland borge/Ge/Hampton (MR)
Bedside Call Cancel Button shall consist of: Supply Installation Testing & Commissioning of Bed side Call & Cancel Push Button , Call Reset, Call Indication in Nurse station for each Bed complete as required. Make:-Rauland borge/Ge/Hampton (MR)
Patient handset with speech shall consist of: Supply Installation Testing & Commissioning of Patient handset with sppech. The patient shall be able to speak directly to nurse assigned to them. The handset shall be full duplex and shall be able to control function within the room through BMS such as lighting , window blinds. the patient shall able to change TV channel and control volume. complete along with module & accesories as required for installation. Make:-Rauland borge/Ge/Hampton (MR)
Patient handset without speech shall consist of: Supply Installation Testing & Commissioning of Patient handset without sppech. The patient shall be able to inform to nurse . The handset shall be full duplex and shall be able to control function such ascontrol room light, reading lamp , window blinds . the patient shall able to change TV channel and control volume.complete along with module & accesories as required for installation. Make:-Rauland borge/Ge/Hampton (MR)
Pull cord for WC & Bathroom shall consist of: Supply Installation Testing & Commissioning of Toilet Call Push Button with LED indication and flexiable cord with button , Call Reset, Call Indication, station for each WC unit complete as required. Make:-Rauland borge/Ge/Hampton (MR)
Code Blue unit /Doctor call unit shall consist of: Supply Installation Testing & Commissioning of code blue unit consisit of Nurse call to Nurse station & code unit to call code blue team with Call Push Button with LED indication , Call Reset, Call Indication, station for each patient room complete as required. Make:-Rauland borge/Ge/Hampton (MR)
SUBHEAD - XXV : Lift
Supply , Installation , Engineering ,Testing And Commissioning of following items of complete Passenger / Bed / Service Lift system in multistorey blocks . All items to include providing all materials and it's assembly at site , labour, T&ps, consumales etc. required at " Jind Haryana" as per specification and drawings and directed by Engineer-in-Charge including transit insurance and storage insurance at site till handing over. Supplier shall provide NOC and inspection certificate from the Lift Safty Septt. of Govt. / Statutarry body (Confermingto IS -14665 Specifications)
Car Type - Stainless steel car in hair line finish 1.22 BG, ARD infrared curtain. Door Size - Maximun available in above category of lifts with Ceramic Flooring
Door operation - Automatic centre / Side opening (as requried) fire rated door with V3F drive.
Operator Door protection - Continuas full infrared Door Protection
Other Provisions to be made in each lift :-
1) Combined luminous hall button with digital hall position indicator at all floors.
2) Integral full height car operating panel with luminous braille buttons , digital car position indicator combined with direction arrows, overload warning indicator.
3) Standard Electrical fittings of Phillips, Havell’s, Bajaj, Crompton greaves or equivalent. Lux Level 150
4) Voice Floor Announcement System with background music
5) Battery operated alarm bell and emergency light.
6) Automatic Rescue Device.
7) Fireman's switch at main lobby.
8) All cables fittings of standard make from distribution board provided. Face plate finish - stainless steel in hairline finish 1.22 BG face plate shape – rectangular
9) Control - A.C. variable voltage variable frequency (with close loop) Operation - Independent IBMS Compatable
10) Machine - Gearless placed directly above the hoistway with regenaration.
11) Car panel - Stainless Steel Panels , SS car door, SS landing door (All Stainless Steel are in hair line finish 1.22 BG)
12) Hand Rail - SS hand rail at 900mm all three side.
13) Ventilation Fan / Blower
14) Fireman's switch for eachlift as tire law.
Above to include supply of mandatory spares & tools for free comprihasive maintenance of 12 months from the date of handing over and obtaining clearances from statutory bodies. Any extra steel structure as required at site.
Bed Lift for Hospital Building
Capacity - 20 Persons (Load 1360 Kg.) Speed - @ 1.0 mps
Travel (Max.) - Basement to 4th floor, (B+G+4). Stops - 6 stops, 6 opening
Shaft Size provided - 2750mm wide x 3000 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.8)
Passenger Lift for Hospital Building
Capacity - 20 Persons (Load 1360 Kg.) Speed - @ 1.5 mps
Travel (Max.) - Basement to 4th floor, (B+G+4). Stops - 6 stops, 6 opening
Shaft Size provided - 2750mm wide x 3000 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.9)
Passenger Lift for Hospital Building
Capacity - 13 Persons (Load 884 Kg.) Speed - @ 1.0 mps
Travel (Max.) - Basement to 4th floor, (B+G+4). Stops - 6 stops, 6 opening
Shaft Size provided - 2500mm wide x 2300 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.4)
Passenger Lift for Academic Block
Capacity - 16 Persons (Load 1088 Kg.) Speed - @ 1.0 mps
Travel (Max.) - Ground Floor to 3rd floor, (G+3). Stops - 4 stops, 4 opening
Shaft Size provided - 2350mm wide x 3000 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.5)
Passenger Lift for Academic Block
Capacity - 16 Persons (Load 1088 Kg.) Speed - @ 1.0 mps
Travel (Max.) - Ground Floor to 7rd floor, (G+7). Stops - 8 stops, 8 opening
Shaft Size provided - 2350mm wide x 3000 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.5)
Passenger Lift for Boy , Girls, Intern Male & Female Hostel
Capacity - 13 Persons (Load 884 Kg.) Speed - @ 1.5 mps
Travel (Max.) - Ground Floor to 19rd floor, (G+19). Stops - 20 stops, 20 opening
Shaft Size provided - 2500mm wide x 1900 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.4)
Passenger Lift for Jr. & Sr. Resident Doctor Hostel
Capacity - 13 Persons (Load 884 Kg.) Speed - @ 1.5 mps
Travel (Max.) - Stilt Floor to 11rd floor, (G+11). Stops - 12 stops, 12 opening
Shaft Size provided - 2500mm wide x 1950 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.4)
Passenger Lift for Type - III
Capacity - 13 Persons (Load 884 Kg.) Speed - @ 1.5 mps
Travel (Max.) - Stilt Floor to 14th floor, (G+14). Stops - 15 stops, 15 opening
Shaft Size provided - 2500mm wide x 1950 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.4)
Passenger Lift for Type - V
Capacity - 13 Persons (Load 884 Kg.) Speed - @ 1.5 mps
Travel (Max.) - Stilt Floor to 15th floor, (G+15). Stops - 16 stops, 16 opening
Shaft Size provided - 2500mm wide x 1950 mm deep, pit size provided - 1600mm deep (DSR PAR 3.1.4)
SUBHEAD - XXVI : FIRE FIGHTING SYSTEM
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (DSR 1)
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainlesssteel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S.fabricated Common base plate, coupling, coupling guard,foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2850 lpm at 88 m Head (DSR 1.1)
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump). (DSR 2)
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
2850 lpm at 88 m Head (DSR 2.1)
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) (DSR 3)
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 88 m Head (DSR 3.1)
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
INCOMING
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A
OUTGOING
Main Fire Pump
Jockey Pump
Diesel Engine Control
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps
Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication
PIPES & ACCESSORIES (DSR 6)
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
200 mm. dia (wall thickness = 6.3 mm) (DSR 6.1)
150 mm. Dia (DSR 6.2)
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (DSR 4)
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
450 lpm at 35 m Head (DSR 4.1)
900 lpm at 35 m Head (DSR 4.3)
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (DSR 7)
25 mm dia (DSR 7.1)
32 mm dia (DSR 7.2)
40 mm dia (DSR 7.3)
50 mm dia (DSR 7.4)
65 mm dia (DSR 7.5)
80 mm dia (DSR 7.6)
100 mm dia (DSR 7.7)
150 mm dia (DSR 7.8)
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : (DSR 9)
Single headed Stainless steel (DSR 9.2)
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : (DSR 10)
Single headed Stainless steel (DSR 10.2)
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : (DSR 11)
50mm dia (DSR 11.2)
80 mm dia (DSR 11.4)
100 mm dia (DSR 11.5)
150 mm dia (DSR 11.6)
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. (DSR 13)
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : (DSR 14)
100mm dia (DSR 14.5)
150mm dia (DSR 14.7)
250mm dia (DSR 14.9)
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. (DSR 15)
250mm dia (DSR 15.5)
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : (DSR 16)
Stainless Steel (Grade 304) (DSR 16.2)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (DSR 17)
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : (DSR 18)
Stainless Steel (Grade 304) (DSR 18.2)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : (DSR 19)
2 way-100 mm dia M.S. Pipe (DSR 19.1)
4 way-100 mm dia M.S. Pipe (DSR 19.2)
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (DSR 20)
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : (DSR 21)
Pendent Sprinkler (DSR 21.1)
Horizontal side wall sprinkler (DSR 21.3)
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. (DSR 25)
700mm (DSR 25.1)
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. (DSR 29)
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (DSR 22)
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. (DSR 23)
150 mm dia (DSR 23.2)
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : (DSR 24)
150mm dia (DSR 24.3)
Providing and fixining gun matel ball valve (RA-5)
Providing and fixining pressure gauge (RA-6)
Providing and fixing in position the industrial type pressure switch (RA-7)
Providing and fixing weather proof standard hose cabinet (900mm x 750 mm x 400 mm) out door type suitable for accommodating yard hydrants made of 1.5mm thick M.S. sheet having central opening glazed door including necessary locking arrangements, painting one coat of primer and two coats of postal red enamel paint and housing 2 Each canvas hose pipe and branch pipe as required. (The cabinet shall be floor mounted on suitable raised platform). The shutters are to be lockable type. The words “Fire Hose Cabinet” to be painted on the box. (RA-1)
Providing and fixing Fire hose cabinet glazed door shutter and frame with hold fasts ( frame fabricated from 40 x 40 x 5mm and shutter from 35x35x5mm M.S. angle) 1500 mm high x 1000 mm wide with locking arrangement, 4mm thick glass with M.S. flats including all accessories, painting with one coat of steel primer and two coats of postal red enamel paint. The words “Fire Hose Cabinet” to be painted on the box. (RA-2)
Providing and fixing air release valve (RA-3)
Fire Extinguisher (RA-4)
Providing and fixing ABC extinguisher with IS: 15683. (ISI marked) (B)
Providing and fixing 4.5 Kg CO2 extinguisher with IS:15683. (ISI marked) (C)
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required. (DSR 28)
SUBHEAD-I:-CHILLERS
Water Cooled Centrifugal chiller package
Supply, Installation, Testing & Commissioning of single/multi compressor centrifugal chiller as per specification & with following tech data:
Technical data:
Chilled Water Leaving Temperature : 44 °F
Chilled Water Entering Temperature : 54 °F
Evaporator Fouling factor : 0.0005 (British Unit)
Chilled Water Circulation Rate : 1920 USGPM
Maximum Permissible Pressure Drop across evaporator: 8 m WC
Condenser Water Leaving Temperature : 100 Deg F
Condenser Water Entering Temperature : 90 Deg F
Condenser Fouling factor : 0.001 (British Unit)
Condenser Water Circulation Rate : 2400 USGPM
Maximum Permissible Pressure Drop across condenser: 8 m WC
Suitable for Refrigerant : Ashrae safety class A1 Category R-134a/ R1233zde
COP Minimum 6.5 at AHRI condition at 800 TR Load Conditions.
IPLV less than 0.35 at AHRI condition at 800 TR Load Conditions.
IKW/TR less than 0.64 at Design condition at 800 TR Load Conditions.
NPLV less than 0.37 at Design condition at 800 TR Load Conditions.
Sound level shall not exceed 83 dba at 1 m distance.
Restrained spring vibration isolator of approved make required for following equipment & rating.
For chillers (MR)
Automatic Tube cleaning system
SITC of Automatic Tube Cleaning system for 3# Chillers (1:3) shall include Touch Screen Graphical PLC, one injection/collection pump, actuator based valves and complete with all accessories and Low side activities of piping connections from Ball traps to Ball collectors and Chillers. The actuator based valves shall give signals to PLC of their functioning and all process of injection and collection should be shown on the PLC while in operation. The ATCS Syetem can be individual to each chiller or may handel multiple chiller at a time with a coomin skid
Chiller Plant Manager
Supply, installation, testing & commissioning of Hand Held Module based chiller system manager to control all the equipment's and working mechanism specified. Synchronization shall be achieved for following Equipment's and to enable sequential operation to achieve equal operating time and take care of load patterns ,optimize plant room performance and electrical power consumption and shall be as per specification. All microprocessor should be BTL listed & UL certified. They should be able to work on BACnet/IP protocol. (MR)
Water Cooled Centrifugal Chiller: 800 TR - (2 # Working+1 # stand by )
Primary Pump : 1920 USGPM - (2 # Working+1 # stand by )
Secondary Pump : 1920 USGPM - (2 # Working+1 # stand by )
Condenser Pump : 2400 USGPM - (2 # Working+1 # stand by )
Cooling Tower : 800 TR - (2 # Working+1 # stand by )
Expansion & pressurization unit - 1 nos
SENSORS AND FIELD DEVICES
Supply, installation, testing, commissioning of necessary Input sensor transmitters/transducers comprising the following:
Immersion type temperature sensor (150mm length) with thermowell and matching sockets and welding job. (MR)
Water Differential Pressure Sensor and matching sockets and welding job. (MR)
Outside Temperature & RH Sensor (MR)
Differential Pressure Switch Across pump (MR)
Dual Level Switch for Cooling Tower Sump (MR)
Current Relay (MR)
Supply, Installation, Testing & Commissioning of Armoured Communication Cabling, 2Cx1.0 Sqmm flexible conductor multi-stranded shielded Insulated FRLS cable complete with erection accessories as required. (MR)
Supply, Installation, Testing & Commissioning of Armoured Signal Cabling, 2Cx1.0 Sqmm flexible conductor multi-stranded Insulated FRLS cable complete with erection accessories as required. (MR)
NOTE: Chiller must be compatible to connect with BMS.Interconnection between chiller & BMS will be in the scope of BMS vendor.
SUBHEAD-II:-PUMPS
Supply, Installation, Testing & Commissioning of End suction back pull out water circulation pump for different water application as under with drive, motor and coupling with following tech specifications :
PRIMARY PUMPS
(2 # Working +1 stand by) (MR)
Water Qty : 1920 USGPM
Static Head : 18 Mtrs
Impeller : Bronze
Speed : 950 Rpm
Seal : Mechanical
Efficiency: NLT 76%
SECONDARY PUMPS WITH VFD
(2 # Working +1 stand by) 1 set of control panel. (MR)
Water Qty : 1920 USGPM
Static Head : 40 Mtrs
Impeller : Bronze
Speed : 950 Rpm
Seal : Mechanical
Efficiency: NLT 76%
CONDENSOR PUMPS
Supply, installation, testing and commissioning of End suction back pull out water circulation pump in cast iron body & Bronze impeller, mechanical seals,complete driven with TEFC squirrel cage induction motor with class-F insulation & efficiency class IE3 suitable for operation on 415 + 10% volts, 3 phase, 50 Hz., AC supply, base plate, MS fabricated mounting channel frame, all required fittings & accessories including coupling, coupling guard, vibration isolation arrangement by means of rubber type mounting, foundation nuts, bolts complete as required & as per specification with following capacities
(2 # Working +1 stand by) (MR)
Water Qty : 2100 USGPM
Static Head : 25 Mtrs
Impeller : Bronze
Speed : less than 1450 Rpm
Seal : Mechanical
Efficiency: NLT 76%
SUBHEAD-III:-HOT WATER GENERTOR
The Pump VFD/ Controller shall be designed so that Head and Flow of the pumps in displayed on the screen so that the pump control curve can be adjusted and monitored as per site head and flow requirement.
Note:- Pump's motor should be BMS Compatible
The above mentioned pumps shall include following:
1 No.- Vertical inline split coupled / End suction pump with minimum 75 % Efficiency
1 No. - Suitable HP TEFC squirrel cage induction type IE3 motor with class 'F' insulation 1500 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply.
Rubber Below Flexible type with MS flanges at inlet & oulet connections of the pump/ Not required in Vibrationless pumps
Lot- RCC Foundation with Anivibration pads / Not require for vibrationless pumps
Water flow rate:\300 USGPM, Head : 27 mtrs (02 Working + 01 Standby ) (MR)
The above item Included with following inbuilt controller
Dedicated microprocessor based pump logic controller, parallel pumping software duly downloaded, sensorless logic, interfacing amongst all components and compatibility of I /O signals, BMS compatible etc complete with other accessories as required. It should be complete as per manufacturer's Specifications & as directed by Engineer-in-charge. multiple differential pressure sensor/ transmitters( Minimum 3 nos) as per the site requirement. VFD shall be capable to operate on Sensorless Control application along wth controller. Controller should have parallel pump logic to operate all set of the pumps with the following features: -Parallel pump operation for power savings. - Controller shall control pump VFD's as per building load variation. Microprocessor controller shall not be mounted on any of the VFD and should be standalone system to have equipments better performance/ Efficiency and reliability.
Electrical Hot Water Generator
Supplying, installation, testing and commissioning of 300 KW electrical hot water generator complete with electrical panel, controls, immersion heaters and insulation etc. as per specification and requirements.
Water inlet & outlet temp. = 50°C & 45°C
Water Flow Rate :- 300 GPM
Vertical Type( As per manufacturer standard)
M.S.Body 8 mm shell 10 mm Dish ends Top Openable with thick M.S. flat plate and sufficient number of Nut Bolts
Inlet out let 50 mm Pipe Flange Ends
Heating Elements should be Electric Resistance Immersion type, copper tube chromplated
Capacity in multiple steps i.e. in 4 bank
Test Pressure 17 KG / cm2
Internally inbuilt Electric Panel consist of 3 phase incomer MCB, steps controller, contactors for each heater with single pole MCB duly factory wired.
Conrols comprising of Step controller for heaters pressure Gauges with Ball Valves , Pressure relief valve, Low water Level cutout / high Temperature cutout ,sight Glass and Auto air vent.
Insulation 50 mm thick Resin Bounded Fiber Glass wool cladded with 0.5 mm Aluminim Sheet.
M.S. Frame welded to the Hot Water Generoator's Body (MR)
SUBHEAD-IV:-COOLING TOWER
COOLING TOWERS (MULTICELL) (CTI APPROVED)
Supply, installation, testing and commissioning of Multicell FRP induced draft cooling tower with FRP water basin, PVC fills with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically & dynamically balanced axial flow, gear/direct driven fans with TEFC induction motor of class F insulation, efficiency class IE-2 suitable for operation on 415 + 10% volts, 50 Hz. AC supply; suction screen, make up-quick fill arrangement, overflow and drain connections with all necessary valves & foot valves, suitable inspection ladder, access arrangement for cooling tower interior, steel /masonry supporting structure with proper design, anti-vibration mountings, suitable civil foundation as per manufacturer's standard with foundation nuts, bolts, painting etc. complete as required and as per specification with the following: (MR)
Capacity : 700 TR (2 #Working +1 Stand by)
Wet bulb temp (monsoon) : 27.5 ° C
Entering water temp : 30.00 ° C
Leaving water temp : 35.00 ° C
Flow rate : 2100 GPM per cooling tower
Each of fans per cooling tower : To be provided by vendor
Supply, Installation, Testing and Commissioning of On line, Non-Chemical Water Treatment Scale Preventer System : For 750 TR/ 2100 USGPM CDW flow rate (2W +1S) CHILLERS (MR)
SUBHEAD-V:-CONDENSER WATER PIPING
Supply, Installation, Testing ,Commissioning & Water-Balancing of Condenser water piping for piping outside the building
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.
Note:- The pipes sizes 150 mm & below shall be M.S. `C' class as per IS:1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS:3589, from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.
400 mm dia. (MR)
300 mm dia. (DSR 16.10.3)
Supplying, fixing, testing and commissioning of following valves,gauges and strainers for condenser water circulation as per specifications.
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
400 mm dia. (MR)
300 mm dia. (MR)
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required.
400 mm dia. (MR)
Balancing Valves WITH BUILTIN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled/hot water circulation as specified.
300 mm dia. (MR)
Wafer Swing Check Valves (Dual Plate) of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.
300 mm dia. (MR)
Y Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
300 mm dia. (MR)
Ball Valves (Manual) with brass body SS Ball, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified.
32 mm dia. (MR)
Pot Strainer for chilled / hot water circulation as specified.
400 mm dia. (MR)
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. (DSR 16.8)
Providing & fixing in position the mercury in glass industrial type thermometers. (DSR 16.9)
U PVC Drain Piping as per specifications ( For Drain) (MR)
100 mm dia (MR)
80 mm dia (MR)
32 mm dia (MR)
SUBHEAD-VI:-CHILLED WATER PIPING(PLANT ROOM)
Supply, Installation, Testing , Commissioning & Water-Balancing of Chilled water piping in plant room along with Insulation
Supplying, laying/ fixing, testing and commissioning of following necessary clamps, vibration isolators and fittings but excluding nominal sizes of chilled water piping inside the building (with valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.
Note:- The pipes size 150 mm & below shall be M.S. `C' class as per IS:1239 and pipes size above 150 mm shall be black steel pipe heavy class as per IS:3589, from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.
350 mm dia. (32 mm Thick) (DSR 16.2.3)
250 mm dia. (32 mm Thick) (DSR 16.2.4)
Supply, Installation, Testing , Commissioning & Water-Balancing of Valves & Fittings along with Insulation
Butterfly Valves (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified
350 mm dia. (MR)
250 mm dia. (MR)
Motorised Butterfly Valves with C I body SS Disc, Nitrile Rubber Seal & O- Ring minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 24 VAC and upto 20 mA electric signal and providing similar transduced feedback output to control system as required.
250 mm dia. (MR)
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
250 mm dia. (MR)
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
250 mm dia. (MR)
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
250 mm dia. (MR)
Ball Valves (Manual) with brass body SS Ball, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified.
32 mm dia. (MR)
Automatic Air Purge Valves @ 15 mm dia. (MR)
Providing & fixing in position the mercury in glass industrial type thermometers. (DSR 16.9)
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. (DSR 16.8)
Supply, Installation, Testing ,Commissioning of Expansion tank (Suitable upto 1000 ltr capacity ) with air & dirt separator unit. Closed type precharged steel Expansion tank with replaceable heavy duty butyl rubber bladder, mounting stand with all necessary system connection & charging valve connection to facilitate on site charging. Tank to meet ASME Section VII division 1, all valve mounting etc. System to be complete with pressurization unit & having two set of pumps(1W+1SB) IP 55 , control panel & accessories like pressure reducing valve , Pressure transmitter, flow meter , auto air purge & interconnecting piping ,cabling, wiring etc . Automatic Centrifugal air separator as shown in the drawing and specifications suitable for line size - 350 mm Dia. (PN16) (MR)
SUBHEAD-VIII:-CHILLED WATER PIPING
Supply, Installation, Testing , Commissioning & Water-Balancing of Chilled water piping in service block & external piping along with Nitrile Rubber Insulation.
Supplying, laying/ fixing, testing and commissioning of following necessary clamps, vibration isolators and fittings but excluding nominal sizes of chilled water piping inside the building (with valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.
Note:- The pipes size 150 mm & below shall be M.S. `C' class as per IS:1239 and pipes size above 150 mm shall be black steel pipe heavy class as per IS:3589, from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.
350 mm dia. (32 mm thick insulation) (DSR 16.2.2)
250 mm dia. (32 mm thick insulation) (DSR 16.2.4)
200 mm dia. (32 mm thick insulation) (DSR 16.2.5)
150 mm dia. (32 mm thick insulation) (DSR 16.2.6)
125 mm dia. (32 mm thick insulation) (DSR 16.2.7)
100 mm dia. (32 mm thick insulation) (DSR 16.2.8)
80 mm dia. (32 mm thick insulation) (DSR 16.2.9)
65 mm dia. (32 mm thick insulation) (DSR 16.2.10)
50 mm dia. (32 mm thick insulation) (DSR 16.2.11)
40 mm dia. (32 mm thick insulation) (DSR 16.2.12)
32 mm dia. (19 mm thick insulation) (DSR 16.2.13)
25 mm dia. (19 mm thick insulation) (DSR 16.2.14)
Supply, Installation, Testing , Commissioning & Water-Balancing of Valves & Fittings along with Nitrile Insultion
Butterfly Valves (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified
350 mm dia. (MR)
300 mm dia. (MR)
250 mm dia. (MR)
200 mm dia. (DSR 16.7.1.1)
150 mm dia. (DSR 16.7.1.2)
125 mm dia. (DSR 16.7.1.3)
100 mm dia. (DSR 16.7.1.4)
80 mm dia. (DSR 16.7.1.5)
65 mm dia. (DSR 16.7.1.6)
50 mm dia. (DSR 16.7.1.7)
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
250 mm dia. (MR)
200 mm dia. (DSR 16.7.2.1)
150 mm dia. (DSR 16.7.2.2)
125 mm dia. (DSR 16.7.2.3)
100 mm dia. (DSR 16.7.2.4)
80 mm dia. (DSR 16.7.2.5)
65 mm dia. (DSR 16.7.2.6)
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
100 mm dia. (DSR 16.7.4.4)
80 mm dia. (DSR 16.7.4.5)
65 mm dia. (DSR 16.7.4.6)
50 mm dia. (DSR 16.7.4.7)
40 mm dia. (DSR 16.7.4.8)
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.
80 mm dia (DSR 16.11.4.4)
65 mm dia (DSR 16.11.4.5)
50 mm dia (DSR 16.11.4.6)
40 mm dia (DSR 16.11.4.7)
32 mm dia (DSR 16.11.4.8)
25 mm dia - for FCUs and Chilled water cassettes (thermostat with 3 step fan speed control) (DSR 16.11.4.9)
Ball Valves with extended lever PN 16 rating
40 mm dia. (MR)
32 mm dia. (MR)
25 mm dia (MR)
Ball Valve with Y-strainer set for FCUs and chilled water cassettes
25 to 40 mm dia. (MR)
Automatic Air Purge Valves 20 mm dia. (MR)
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. (DSR 16.8)
Providing & fixing in position the mercury in glass industrial type thermometers. (DSR 16.9)
U PVC Drain Piping with 6 mm thick nitrile rubber insulation as per specifications ( For Drain)
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
SUBHEAD-IX:- AIR MOVING EQUIPMENT'S
Supply, Installation, Testing & Commissioning Air moving Equipment
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters,belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Each)and industrial type thermometers (2 Each) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following (DSR 16.26)
4300 CMH (DSR 16.26.1)
5100 CMH (DSR 16.26.2)
6800 CMH (DSR 16.26.3)
8500 CMH (DSR 16.26.4)
10200 CMH (DSR 16.26.6)
15300 CMH (DSR 16.26.8)
12.0 TR; 5000 CFM; 125 mm static (with 6 kW heater bank) (MR)
18.0 TR; 8000 CFM; 125 mm static (with 10 kW heater bank) (MR)
28900 CMH (DSR 16.26.13)
Supply, Installation, Testing & Commissioning OF DOUBLE SKIN TYPE FLOOR MOUNTED VERTICAL/HORIZONTAL Treated fresh air unit ( TFA ) As per approved dwg/ Site requirement.
4.0 TR; 600 CFM; 65 mm static (MR)
Supply, Installation, Testing & Commissioning of Ceiling Suspended low static fan coil units with equipped with adequate sized multi-row chilled water coil, 3 speed fan BLDC motor along with its accessories and factory fitted ball valve, ball valve with y strainer set & Control valve of PN 16 Rating duly insulated with Closed Cell Elastomeric Rubber insulation with Extended drain pan & inbuilt drain pump & Fire Retardant Quality Flexible Canvas connection between FCU & Duct suitable for following capacities of units. Complete as per specification & drawings. The unit shall be with 2-pipe connection. (ESP-3MM for Ducting length 1.1M- 3.0 M, noise level ≤ 38 Db at 2 M distance from unit , ESP-5 MM for More Ducting length ). The unit shall have the provision to be connected via BMS for both control and monitoring purposes, additional items required may be specified.
1.0 TR /400 CFM (MR)
1.5 TR /600 CFM (MR)
2.0 TR /800 CFM (MR)
2.5 TR /1000 CFM (MR)
3.0 TR /1200 CFM (MR)
Capacity: 1 TR; Flow Rate: 400 CFM (MR)
Capacity: 1.5 TR; Flow Rate: 600 CFM (MR)
Capacity: 2.0 TR; Flow Rate: 800 CFM (MR)
Capacity: 3.0 TR; Flow Rate: 1200 CFM (MR)
Capacity: 4.0 TR; Flow Rate: 1600 CFM (MR)
SUBHEAD-X:-DUCTING & AIR DBS
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (DSR 16.12.1)
Thickness 0.63 mm sheet (DSR 16.12.1.1)
Thickness 0.80 mm sheet (DSR 16.12.1.2)
Thickness 1.00 mm sheet (DSR 16.12.1.3)
Thickness 1.25 mm sheet (DSR 16.12.1.4)
Factory Fabricated Alumimnium Rectangular Ductwork as per SMACNA standard for following gauges ( OT area , sterile area ,MRI CT sacn & crtical area )
1 - 750 mm 24 (4 Bolt TDC (E) (MR)
750 - 1500 mm 22 (4 Bolt TDC (H) (MR)
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. (DSR 16.17)
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. (DSR 16.18)
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. (DSR 16.15)
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. (DSR 16.16)
Opposed blade Aluminium Grill/collar dampers. (MR)
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. (DSR 16.13)
Supply, installation, testing and commissioning of Alluminium volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. (MR)
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. (DSR 16.20.1)
Actuators (DSR 16.20.2)
Panel & Cabling (in FAS Scope)
Providing flow limiter suitable for fresh air.
100 CFM (MR)
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications.
150 MM Dia (MR)
100 mm dia (MR)
Supply, installation, testing and commissioning of Terminal mounted HEPA Tent with HEPA BOXES in 18 G SS304 construction duly powder coated and complete with volume control damper in 18G GI and Al powder coated perforated sheet. HEPA box should completed with all accessories like pressure plate, gear for damper operation along with HEPA FILTERS ( High efficiency particulate air) designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.97 %. The filter matrix comprises specially treated glass fibber media with machine pleated aluminium separators.
2440MM X 2440 MM (MR)
2440MM X 1830 MM (MR)
Supply, installation, testing and commissioning of powder coated GI Return air Riser for OT Area .
950x150 for OT AREA (MR)
Supply, installation, testing and commissioning of Multi -function room monitor (MIRM) ,With vertical type Panel . it shall work on 24VAC supply with +/- 10% variation.output being standard type. with an accuracy of +/- 3%. for measure temperature,humidity, & differential pressure & must be compatible to connect with BMS. For OT Area. Consist of SMPS & junction box to convert 24 VAC , Communication cable 2 core x1.0 sqmm shieled cable for each senser , 3core x1 sqmm shieled cable for concetivity BMS system with RS-485 port . (MR)
Validation Work
HEPA filter validation with the dop method with particle arrestance capacity of HEPA filter and to evaluate the class conditions in the room with at rest & at operational readings.the validating agency shall be third party and enough competent & capable to certify the testing. also the agency shall have all in house calibrated testing equipment's with following : a) HEPA filter integrity test ( DOP test ) b) air velocity measurement c) particle count at rest & at operation (MR)
DQ, IQ, OQ & PQ Documentation with making complete report with testing for temp,. humidity, pressure gradient, class conditions at rest & at operation with all required drawings, data sheets, design basis, technical specifications etc. to compete the report for the approval of competent third party authority. The work shall also includes the preparation of as built drawings as per the actual work execution at site. All above document along with test certificates, readings and as built drawing shall have to be submitted in 3 sets with soft copy of the same. (MR)
Insulation
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
25 MM THK for Expose supply air duct , OT/sterile Area SA duct . (DSR 16.23.2)
19 MM THK rest of All Supply air duct ,Exopse return air dcut OT /sterile return air duct (DSR 16.23.1)
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. (DSR 16.21)
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. (DSR 16.22)
SUBHEAD-XI:-DRY VENTILATION
LIFT WELL/LIFT LOBBY /STAIRCASE PRESSURIZATION
12000 CFM With 20 MM Static for lift well pressurization . (MR)
Floor Mounted Single skin Cabinet Type Exhaust air Units with DIDW type forward curved fan as per specification and of following capacities with Built-In Drive And Drive Package.
1500 CFM WITH 25 mm static for toilet exhaust (MR)
3000 CFM WITH 30 mm static for toilets on ground and first floor (MR)
3000 CFM WITH 25 mm static for toilets on second and third floor (MR)
Rigid PVC pipe for Toilet exhust with necessary fittings
Smoke fumigation fan
S/I/T/C of Single Skin cabinet fan for FUMIGATION as per specification and following capacities With Built-In Drive And Drive Package.
1000 CFM WITH 25 mm static for crtical area ( fumigation fans ).
Floor Mounted/Ceiling suspended Single skin Cabinet Type Fresh air Units with DIDW type forward curved fan as per specification along with 20 micron prefilter and of following capacities with Built-In Drive And Drive Package.
1500 CFM WITH 35 mm static (MR)
3000 CFM WITH 35 mm static (MR)
SUBHEAD-XII:-MECHANICAL VENTILATION
BASEMENT VENTILATION
Tube Axial Flow Exhuast Air Fans for car park ventilation
Supply, installation, testing and commissioning of dual speed Fire Rated Axial Fans, complete with TEFC motor, drive and vibration spring isolators, flexible connections, bird screen & back draft damper . Motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply and shall have high efficiency motors. Fan static pressure is mentioned below. The fans should be AMCA certified for air performance & sound ratings. To achieve specified DB levels, sound attenuators of suitable length shall be provided at inlet /outlet of the fans must be included in the cost). The fans ,motors and complete assembly shall be suitable for 300 Deg C for 2 hour fire rating.
22500/45000 CFM Dual Speed with 20 MM STATIC (Normal mode) FOR BASEMENT - I (MR)
SITC of CBRIL /UL approved CO Sensors (MR)
SITC of PLC Control Panel with logic card Master controler for each zone shall be separate and to be located in the main control room. Starters to be incorporated in separate starter panel (MR)
Computerised Flow Analysis for basement (MR)
Jet-vent fans- Dual speed
Supply, installing, testing and commissioning of Dual Speed Ductless Ventilation / Jet fans as per specifications for normal ventilation suitable for Normal ventilation and Smoke Extraction application. The complete fan assembly with all supporting, mounting structural frame, Casing, impeller, tranformer, starter & motor (the entire motor fan,controller etc., as a full package) shall need to be imported from manufacturer and certified as tested for 300 Deg C for 2 hours operation. The jet Impulse fans sutabile dia Fan is with mounting arrangements. Along with necessary protective grill & Structure work. Each fan shall be complete with Dual speed motor. Casing shall be made Galvanized Aluminum. The Motor shall be run on the electrical power suitable for 50Hz.
460 mm dia .FOR ZONE-I (MR)
460 mm dia .FOR ZONE-II (MR)
Ahluwalia Contracts India Ltd.
NCC LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid