| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L4₹38.8 L+₹32,623.10 (0.85%)Accepted-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Accepted-AOC Declared L1 bidder amongst bonafide bidders | |
| 2 | L1₹38.5 LRejected-Finance | L1 | Rejected-Finance Quoted less than min wages of labour | |
| 3 | L2₹38.8 L+₹32,300.70 (0.84%)Rejected-Finance WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Quoted less than min wages of labour | |
| 4 | L3₹38.8 L+₹32,421.60 (0.84%)Rejected-Finance FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L3 | Rejected-Finance Quoted less than min wages of labour | |
| 5 | L4₹38.8 L+₹32,623.10 (0.85%)Rejected-AOC | L4 | Rejected-AOC OK |
Tender Value
Refer Docs
EMD Value
₹95,400
Closing Date
11 Mar 2021, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
OUTSOURCING OF SERVICES FOR DG SETS, ELECTRICAL SUBSTATION AT DIPAS, CFEES, NMR AC PLANT 75 TR AND 40 TR AC PLANT AT INMAS, LIFT OPERATORS AT MAIN AND ADMIN BLDG INMAS AND DIPAS AT KWC AREA UNDER GE I RND DELHI
2021_MES_415711_1
GE/RND-61/DLI/2020-2021
Open Tender
Civil Works
Item Rate
330 days
DELHI
Class- D, Cat - d(v)
2 documents required · 2 mandatory
₹500
GE I RND DELH
₹95,400
Yes
30 Mar 2021
23 Jan 2021
13 Mar 2021
23 Jan 2021
11 Mar 2021
27 Feb 2021
Amount
PART-I: MANNING AND OPERATION WORK Outsourcing of services for manning & Operation of CFEES main receiving electric substation alongwith DG sets of capacity 20KVA and 75 KVA in round the clock (24 hrs) in three shifts per day Ist shift from 0600 Hrs to 1400 Hrs, 2nd shift from 1400 Hrs to 2200 Hrs and 3rd shift from 2200 Hrs to 0600 Hrs including sunday and holiday by deploying one skilled Electrician in every shift complete all as specified & directed. The installation comprising with the following equipments:-
(A) Vacuum Circuit breaker (VCB) HT 11 KV, 3 phase, 50 Hz rupturing capacity 630 Amps -05 Nos. (B) Potential transformer of capacity 11 KV/110 volts attached with main HT Panel complete. (C) Transformer step down 400 KVA,11 KV/433 volts indoor type natural oil cooled -01 No. (D) LT panel -01 No consisting of the following:- (i) Incoming ACB rating capacity 800 Amps - 01 No. (ii) Out going MCB 40 Amp 03 Nos. (iii) MCCB out going 100 Amps -05 Nos. (E) LT panel consisting of the following:- (i) MCCB 320 Amps-01 No. (ii) MCCB 225 Amps-01 No. (iii) MCCB 100 Amps-12 Nos. (F) Diesel engine 75 KVA -01 along with 12 Volt 180 AH battery including alternator. (G) Diesel engine 20 KVA -01 along with 12 volt 18 AH battery with alternator.
Outsourcing of services for manning, Operation & Maintenance of electric sub station at DIPAS,round the clock (24 hrs) in three shifts per day Ist shift from 0600 Hrs to 1400 Hrs, 2nd shift from 1400 Hrs to 2200 Hrs and 3rd shift from 2200 Hrs to 0600 Hrs including sunday and holiday by deploying one skilled Electrician in every shift including service, maintenance of earthing of installation, complete all as specified & directed. The installation mainly comprises of the following equipments/switch gears:-
(A) HT OCB 400 Amp - 04 Nos. (B) Transformer step down 11 KV/430 Volt of 1000 KVA – 02 Nos. (C) LT panel comprising of the following:– Incomer Air Circuit breaker 1600A – 1 No Out going MCCB 800A-4Nos MCCB 200A, 35 KA – 01 No. Incomer Air Circuit breaker 1600A – 1 No (incomer). Outgoing MCCB 800A-02 Nos MCCB 630A 50 KA-03 Nos MCCB 200A, 35 KA-01 No. (D) Transformer step down 11 KV/430 Volt of 750 KVA – 01 No. (E) LT panel comprising of the following:- Incomer Air Circuit breaker 1250A-1 No Outgoing MCCB 800A- 01 No MCCB 400 A 50 KA – 03 Nos MCCB 200A, 35 KA-01 No MCCB 100 A-02 Nos. (F) Capacitor Bank panel 225 KVAR complete with all accessories – 02 Nos.
Outsourcing of services for manning & operation of central AC plant 2x40TR capacity installed at CT Scan building of INMAS area to maintain inside ambient temperature conditions throughout running period by cooling or heating, in SINGLE SHIFT of 8 hours per day (0900 Hrs to 1700 Hrs) including Sundays and holidays, by providing and deployment of one skilled operator cum mechanic per shift, including routine and periodical check ups and attending minor repair for proper functioning of plant, components such as compressor, condenser electric motors, pumpsets, AHU, blower motor, water suctions and discharge pipelines, refrigeration piping system alongwith functioning of interlocking system LP/HP outlet etc, including upkeep of the installation in clean and tidy condition internally and surrounding areas externally by cutting of grass and bushes /wild plants complete all as specified & directed by Engineer-in-Charge. The plant mainly comprises the following:-
(a) Compressor of Make Blue Star - 02 Nos. (b) Condenser unit - 02 Nos. (c) AHU complete with electric panel, electric panel, electric motor - 03 Nos. (d) Condenser/chiller pump set complete with mono block and motor of capcity 12.5 HP-02 Nos. (e) Chiller water pump set with motor of capacity 20 HP - 02 Nos. (f) Chilled tank - 01 No. (g) Cooling tower complete with electric motor - 01 No. (h) Main electric panel with MCCB up to 300 Amps. (j) AC ducting complete set - 01 No. Note (i) The inside temperature conditions to be maintained in the building are as under:- Temperature 200C +/- 20C, Relative Humidity 50 % +/- 5%. (ii) Shift timing shall be followed as per user requirement with prior information.
Outsourcing of services for manning & operation of central AC plant 3 x 75 TR capacity installed at NMR building of INMAS area to maintain inside ambient temperature conditions throughout running period by cooling or heating, in THREE SHIFTS of 8 hours each per day (0600 hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 hrs 2nd Shift, 2200 hrs to 0600 hrs 3rd shift) including Sunday and holidays, by providing and deployment of one skilled operator cum mechanic per shift, including routine and periodical check ups and attending minor repair for proper functioning of plant, components such as compressor, condenser electric motors, pumpsets, AHU, blower motor, water suctions and discharge pipelines, refrigeration piping system alongwith functioning of interlocking system LP/HP outlet etc, including upkeep of the installation in clean and tidy condition internally and surrounding areas externally by cutting of grass and bushes /wild plants complete all as specified & directed by Engineer-in-Charge. The plant mainly comprises the following:- (a) Compressor of make Blue Star- 03 Nos. (b) Condenser unit - 03 Nos. (c) AHU complete with electric panel, electric panel, electric motor - 04 Nos. (d) Condenser pump set complete with motor of capacity 20HP - 02 Nos. (e) Chiller water pump set with motor of capacity 20 HP - 02 Nos. (f) Chilled tank - 01 No. (g) Cooling tower complete with electric motor - 01 No. (h) Main electric panel with MCCB up to 300 Amps. (j) AC ducting complete set - 01 No. Note: (i) The inside weather condition to be maintained in building are as under : Temperature 200C +/- 20C , Relative Humidity 50 % +/- 5%. (ii) Shift timings shall be followed as per user requirement with prior information.
Outsourcing for manning & operation of electrically operated lift of capacity 08 passangers - 01 No, suitable for G+3 (Ground+3 floors) installed at ADMIN building INMAS to be operated in one shift (0830hrs to 1730 hrs) from Monday to Friday, except Holidays as declared by SSPL Lab by deploying one skilled Operator cum Mechanic complete all as specified and as directed.
Outsourcing of services for mannning and operation of electrically operated lift of capacity 08 passangers - 01 No, suitable for G+2 (Ground+2 floors) installed at Main building at INMAS to be operated in one shift (0830hrs to 1730 hrs) from Monday to Friday, except Holidays as declared by INMAS Lab by deploying one skilled Operator cum Mechanic complete all as specified and as directed.
Outsourcing of services for manning and operation of electrically operated lift of capacity 08 passengers suitable for G+3 (Ground+03 floors) installed at Main building DIPAS to be operated in one shift of 08 hours per day( 0900 hrs to 1700 hrs) and five days in a week (from Monday to Friday, except holiday as declared by DIPAS) by deploying one skilled operator cum mechanic complete all as specified and as directed.
Rate required to be quoted for executing the work as described in Ser item No 1.00 to 7.00 above
Workers wage per person as per existing rules.
ESIC (Employees state insurance contribution) as mentioned in tender document.
Bonus as mentioned in tender documents
Overhead & Profit on Ser No 8.01 to 8.03
LWC as mentioned in tender documents.
GST as mentioned in tender documents.
Notes : Rate quoted by the contractor shall deemed to be included the following :- (i) Operator cum mechanic (skilled) shall be of Diploma/ITI passed with having training certificate in relevent trade not less than three year shall be employed for each shift.. (ii) It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/State Govt/Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC , Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable. (iii) In case the rates quoted by tenderer are less than the notified minimum wages as on bid submission end date including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable, his tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongst valid/bonafide bids only. (iv) The firm/contractor shall be solely and fully responsible to his reprsentative/personal for any accident/damage during maintenance/operation/health related liabilities/compensation, penelty etc on this account. (v) T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost.
(vi) Contractor shall be responsible to maintain log books, duty roster attendance register and spare for repair/renewal of parts register, earth register, serviceability register of lifts and as directed by Engr-in-charge. (vii) Shift Operator (reliever) shall neither leave the installations without prior permission of JE/Engineer-in-Charge. Proper handing/taking over to the next operator will be made. (viii) Two pairs of uniform with name plate of operator & firm and shoes shall be provided to each operator by the contractor. (ix) First Aid box will be provided by contractor at each installation. (x) Any increase in minimum wages of labour as fixed by the Govt of India/state Govt/ union Territory, whichever is higher shall be paid to the contractor in accordance with the provision made vide condition 63 of IAFW-2249. Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. no other claim whatsoever shall be addmissible on this account and the bidders shall consider this aspect while quoting their rates. It must be noted that in compliance of the statutory provisions, the increased will be passed over to the workers. (xi) Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt for this shall be maintained by the Engineer-in-Charge & contractor.
(xii) The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates. (xiii) Duty roster for detailement of operators shall be approved by Engr-in-charge within first three days of every month and the same shall be kept on record and properly displayed at each installation. (xiv) The contractor will arrange the earth tester, Megger & clamp meter for installation and will check all the earthings of lifts for its serviceability in presence of JE E/M, Engr-in-Charge and test report shall be submitted to the office of AGE E/M duly signed by the contractor on commencement of work for record. (xv) For any damage to the installations due to negligence of operator such as loose connections, improper routine check up/maintenance etc. the contractor shall be held fully responsible to replace the same damage at his own cost all as directed by Engr-in-charge. (xvi) Original certificates regarding qualifications of operators engaged in the work, police verification and identity proof shall be produced by the contractor to the Engineer-in-Charge for verification and approval.
PART-II: REPAIR/MAINT WORK Taking down carefully point wiring aluminium (light, fan, socket, and power) complete (including fittings such as switches ceiling roses, pendent regulators sockets etc except light fitting complete all as specified and as directed.
M&L for point wring for one light point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLSH in and in surface PVC conduit 20 mm dia medium duty ISI marked, including suitable new steel sunken boxes, modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface for one light point, fan point, controlled by one switch including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLSH connected to common earth duly complete all as specified and directed.
S&F modular switch 6 Amps 230V AC, one way complete all as specified and directed.
S&F in repair of LED 34W surface mounted panel light mounting which provides soft-light and glare free symmetrical illumination 2'X2', 230 volt, 50 Hz and cable for connecting to ceiling rose complete all as specified and directed.
S&F in repair of Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.trica batten 230 volt, 50 Hz, 20 watt and cable for connecting to ceiling rose complete all as specified and directed.
S&F in repair of light fitting to new ultra modern LED recess mounting luminaire enviromental friendly, new generation, aesthetically designed with high brightness, 2'×2' fitting 34W and making all electric connections all as specified and directed.
G M CONSTRUCTION COMPANY
HIND CONSTRUCTIONS
V r traders
M/S VEDHANT ASSOCIATES
Pradeep Bros
M/s Adhikari construction co.
M/s Wazer Enterprises
ENVIRO TECH SERVICES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .