Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹38.3 L+₹19,968.40 (0.52%)Rejected-Finance 1331 GENERAL GANJ OPP WATER TANK MATHURA 281001 | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹38.4 L+₹36,600.20 (0.96%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹40.5 L+₹2.5 L (6.45%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹40.6 L+₹2.5 L (6.50%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹48.2 L
EMD Value
₹96,500
Closing Date
25 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
SPECIAL REPAIR TO BLDG NO E-05 AND MINOR WORK (MTR/MINOR WK/16/2024) UNDER GE (E) MATHURA
2024_MES_677011_1
8200-1464/E8
Open Tender
Civil Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE EAST MATHURA
₹96,500
9 Dec 2024
27 Sept 2024
1 Nov 2024
27 Sept 2024
25 Oct 2024
11 Oct 2024
27 Sept 2024 - 18 Oct 2024
Amount
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for Brick work using old size fly ash Bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick walls and concrete surface including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L for rendering 15mm thick on other than fair face of brick work or concrete surface in cement mortar 1:4 finished even & fair complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even & fair complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls providing 1mm thick wall care putty and applying two coat of oil bound distemper over and including a coat of alklai resitant primer complete all as specified and as directed.
M&L for preparation of new plastered or un plastered surface of walls and applying two coat of cement based paint complete all as specified and as directed.
M&L for complete removal of existing treatment from old plastered surfaces of walls and applying two coats of distemper oil emulsion, white or tined complete all as specified and as directed.
M&L for preparation of old plastered surface of walls and applying two coat of cement based paint complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamal paint complete as specified and as directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamal paint over and including a coat of red oxide primer complete as specified and as directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamal paint complete as specified and as directed.
Dismantling of plain or corrugated steel sheeting of any gauge, thickness, including ridges, hips, valleys etc complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet AZ-150, 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet AZ-150, 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 as in ridges, hips, valley, gutters etc. fixed with self tapping screws complete all as specified and as directed.
S&F rolled mild steel joist, channel, angle or Tee section fixed independently without connecting plate etc cut to ordinary length i.e. within 20 mm of length indicated) of Fe 410 Gde E-250 quality complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping, benching etc complete all as directed and as specified.
S&F in repair for powder coated aluminium frame (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with dash fasteners of required dia and size including necessary fitting without the gaps at junctions, i.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling, C.P. brass/stainless steel screw,complete all as specified and as directed.
S&F in repair anodised aluminium grill, grill thickness not less than 6.0 mm, anodised transparent or dyed to requied shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the exsiting window frame with C.P brass/ stainless steel screws @ 200mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed
S &F in repair powder coated (minimum thickness of powder coating 50 micron) aluminium door shutter, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 nos in each door, hinges, tower bolt 2 Nos in each shutter anodised aluminium snap beading screws etc complete all as specified & directed.
S&F in repair Powder coated aluminium (thickness of powder coating not less than 50 micron) window and ventilator shutters, side hung type with sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised powder coated aluminium snap beading, screws, powder coated aluminium anodised fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
S&F 5.5mm thick, Sheet glass ordinary quality and glazing with aluminium beading exc 0.5 sqm in each pane complete all as specified and as directed.
S&F 5.0mm thick ACP Sheet (aluminium composite sheet) fixed with aluminium beading in each pane complete all as specified and as directed.
S&F 100mm mild steel mortice lock, verticale type, 2 levers complete as specified and as directed.
S&F Aluminium body (extruded section) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
S&F in replacement factory made steel window with side hung shutter including box type hinges with steel handle of MS flat 25 x 5 mm and 2 Nos 100 mm long steel tower bolt fixed to shutter complete with and including glazing bars, dovetailed or welded, complete all as specified and as directed.
S&F for 4mm thick, Sheet glass ordinary quality and glazing with oil putty in squares n ecx 0.5 sqm in each pane including punching or drilling out old glazing pins/spring clips, and providing & fixing new ones complete all as specified and as directed.
S&F in repair 4mm thick, Sheet glass ordinary quality and glazing with oil putty/wooden beading in square n exc 0.5 sqm in each pane complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed.
M&L for 25 mm (Average) thick cement concrete type- B0 1:2:4 (using 12.5 mm graded stone aggregate) as in floor/padding surface finished rough to received screed for tiling compete all as specified and as directed.
M&L for dark shade Vitrified Ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface of size 350x250x7mm/450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick rendering in cement motar 1:3 complete all as specified and as directed.
Roughening surfaces of old concrete floor/chajja/facia/ any type concrete projections by picking, sweeping clean and washing down with water to remove dust, etc, complete all as specified and as directed.
M&L for preparation of old concrete surface and brushing neat cement slurry @ 3 kg of cement per sqm complete all as specified and as directed.
M &L for granolithic concrete 1:1:2 surfaces topping 50 mm thick mixed with floor hardener as per manufacturer instructions, laid over cement concrete etc. and finished to an even and fair surface complete all as specified and as directed.
S&F in repair 200 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls with suitable MS clamps complete all as specified.
S&F in repair 200 mm dia PVC (Rain Water Pipe) bends any radius, complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (Below or above ground level) including removal of debris outside of MOD land complete all as specified and as directed.
M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for reinforced cement concrete B1 1:2:4 (using 20 mm graded aggregate) as in cover slabs for manholes etc including necessary form work complete all as specified and as directed. Note : Reinforcement shall be measured and paid separately.
M&L for 50 mm thick cement concrete 1:3:6 type C0 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and fair without using extra cement complete all as specified and as directed.
M&L 100 mm thick cement concrete 1:4:8 type D2 (using 40 mm graded aggregate) as in sub base complete all as specified and as directed.
M&L for Chequred Cement concrete coloured tiles glossy finish, rubber moulded with grey cement and pigments 20cm x 30cm x 25mm thick machine pressed set jointed and pointed in neat cement slurry in floors, laid over with and including 20 mm thick screed bed in CM 1:4 all as specified complete all as specified and as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed .
Dismantling timber scantlings (framed work) in fillets, rails, posts, rafters, purlin etc under 40 sqcm in section complete all as specified and as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed .
M&L for 4 mm thick asbestos cement plain building board fixed or laid on MS framework fixed in ceiling complete all as specified and as directed.
S&F MS Framed work such as grills gratings, door and cooler stand, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars and similar work confirming to Fe.290.Gde-E-165 complete all as specified and as directed.
Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc.) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fittings etc) and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as specified and as directed.
Taking down carefully by Submain wiring of any type making good the disturbed surface to match with existing surface complete all as specified and as directed.
Taking down old unserviceable existing SPN/TPN DB/enclousers any size and type/any descriptions as iron sheet scrap including MCB any type/size and making good disturbed surface/wall as per existing complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core PVC insulated (FRLS) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non metalic PVC conduit (not less than 20mm dia med grade and its all acessories complete concealed in walls/roof including cutting & chases (making good all to the disturbed surfaces as per existing) including earth wire of PVC Insulated FRLS copper conductor, multi standard of 1.5 sqmm size green in clour of complete all as specified and as directed the followngs:- Note :- Flush metal boxes, modular cover plate with frame shall be measured and paid separately under relevant items of this BOQ.
One light/fan/exhaust fan point controlled by one way switch 5 amp complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on same board complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on independent board complete all as specified and as directed.
All as per item No. 53.00 here-in-above but for 3pin/5pin 16Amps socket point controlled independently, with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent Point wiring complete all as specified and as directed.
Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete all as specified and as directed.
Supply and Fixing Modular switch 16 Amp single pole one way,1 Module complete all as specified and as directed.
Supply & Fixing Modular fan Regulator electronic step type 2M complete all as specified and as directed.
Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified and as directed.
Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified and as directed.
S&F ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
S&F lamp holder (angle), PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F modular white cover plate with frame, 1 module complete all as specified and as directed.
S&F modular white cover plate with frame, 3 module complete all as specified and as directed.
S&F modular white cover plate with frame, 4 module complete all as specified and as directed.
S&F modular white cover plate with frame, 6 module complete all as specified and as directed.
S&F modular white cover plate with frame, 8 module complete all as specified and as directed.
S&F Modular metal flush box 1/2 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F Modular metal flush box 3 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F Modular metal flush box 4 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F Modular metal flush box 6 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F Modular metal flush box 8 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and as directed.
S&F indoor decorative ultra slim surface/Wall mounted LED batten tube light fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired with and including 1 x 20 watt LED tube and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F intergrated Batten PC housing extruded T5 LED batten tube 2' light fitting complete with all accessories internally pre-wired with and including 1X9 watt LED Tube connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement of recess mounting LED light fitting 2x2, square shape 24W, 230V complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and as directed.
S&F LED retrofit lamp 9 Watt complete all as specified and as directed.
S&F of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V with and including 30W LED tube all connections complete all as specified and as directed.
S&F for building security light bracket made out of 40mm dia medium grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including applying two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
Taking down the ceiling fan/Exhuast fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearings, reassembling the fan and blades, painting of fans with synthetic enamel paint by spraying a single coat as per existing colour paint including provision of 3 core twisted flexible copper conductor cable 0.75 Sqmm from ceiling rose to connector of fan, hanging/fixing the fan in its original position and testing on completion complete all as specified and as directed.
M&L for Sub Main Wiring with two runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 6sqmm copper green colour earth wire complete all as specified and as directed. Note: Two runs 6sqmm, one run of 6sqmm earth wire & One run of PVC conduit shall be measured as one unit length.
M&L for Sub Main Wiring with four runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 6 sqmm copper green colour earth wire complete all as specified and as directed. Note: Two runs 4sqmm, one run of 6sqmm earth wire & One run of PVC conduit shall be measured as one unit length.
S&F TP&N Vertical Loadline distribution board, 8 Way, Double door, sheet steel, phosphatised, powder coated with Copper bus-bar 250Amp, two neutral link, earth bar with provision for 125Amps MCCB as incomer and SP/TP MCBs as outgoing, cable ties for cable management, 440 V, 8 way complete all as specified and as directed Note : - (i) MCBs/MCCB, DBs shall be of same make. (ii) DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as directed & rate shall be included in the items. (ii) MCB/MCCB's DBs shall be measured and paid separtely under relevant items of this BOQ.
S&F MCB distribution board, TPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F sheet metal enclosure MCB distribution board, SPN 8 Way, Double door, phosphatised, powder coated with 200Amp rated bus-bar, neutral link, earth bar and din rail , cable ties for cable management, 240 V complete all as specified and as directed.
S&F MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F SP enclosure modular type with a two pin and earth plug and socket complete with SP MCB of rating 20-32 Amps, 240V complete all as specified and as directed.
Supply and fixing MCCB 125Amp rating, 4-pole 415V, adjustable thermal and fixed megnetic type, 'C' series, breaking capacity 16KA complete all as specified and as directed.
S&F MCB TPN 40 to 100 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F in replacement MCB TP 40-63 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F MCB DP 40-63 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F MCB SP 6-32 Amps, 'B' series, breaking capacity 10KA, 240V complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor of size 50 Sqmm 3.5 core laid in trenches/duct/fixing on walls/poles connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole/Main Panel Box and testing complete all as specified and as directed. Note:- Excavation and earth work shall be measured and paid separately under relevant item(s) of this schedule.
Excavation in trenches in not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundations, laying of cables etc and getting out as in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
M&L for sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and as directed. Note : For payment punned depth shall be measured.
Supply and Laying in trenches reinforced precast concrete cable cover class LV type 1, flat, size 250mmx150mmx40mm for cable protection cover complete all as specified and as directed.
Supplying & fixing steel tubing ,galvanised, medium grade 40 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed.
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete.
Supply, installing, testing & commissioning of split type Air conditioner indoor/outdoor unit (compressor) complete 1.5TR capacity with cordless remote controler unit and with inbuilt air Ioniser and Plasma filter 5 star rated suitable for working on 230 Volts, single phase, 50 Hz supply, complete including cutting/drilling in wall for inserting cooling pipe & drain pipe including providing stand for outdoor unit and making good disturbed surface of walls to match the existing surface etc complete all as specified and directed.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed.
Supply & Fixing Sub main wiring with two run of single core 4 Sqmm cable PVC insulated unsheathed (FRLS) cable with multistrandard copper conductor, 1100 votls grade drawn through and including concealed PVC conduit 20 mm dia medium duty including all its acessories such as Tee, bend, elbow etc ISI marked with and concealed in wall/roof including necessary cutting/chase and making good distured surface including 4 Sqmm PVC insulated unsheathed stranded (FRLS) cable for earth wire complete all as specified and as directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire & 20mm PVC Conduit shall be measured as one unit length.
Supply and fixing MCCB 100 to 125Amp rating, 4-pole 415V, adjustable thermal and fixed megnetic type, breaking capacity 35KA complete all as specified and as directed.
Supply & Fixing Powder coated CRCA mild steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 200 Amps rated copper bus bar complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade 16 Sqmm 4 core cable with aluminium conductor laid in trenches/pipes, fixed to poles/walls, fixing with suitable saddle/clamps complete all as specified and as directed.
JWALA ELECTRIC CONTRACTORS (BID ID -3142232)
KALPAARAV CONSTRUCTION (BID ID -3143151)
Deepak Saxena (BID ID -3140819)
M/S ANIL KUMAR (BID ID -3142106)
KASHI NATH BANWARI LAL (BID ID -3147777)
BHARDWAJ CONSTRUCTIONS (BID ID -3139639)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .