Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.1 LAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC Being lowest and reasonable tender | |
| 2 | L2₹97.2 L+₹4.0 L (4.30%)Rejected-Finance | L2 | Rejected-Finance Being second lowest bidder | |
| 3 | L3₹1.1 Cr+₹18.6 L (20.0%)Rejected-Finance | L3 | Rejected-Finance Being third lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected since firm is not meeting requisite eligiblity criteria wrt value of works executed as per NIT being not enlisted in c(vi) category | |
| 5 | Rejected-Technical S 79 OKHLA INDUSTRIAL AREA PHASE II NEW DELHI 110020 | SOUTH EAST | DELHI | 110020 | - | Rejected-Technical Being three class below contractor and not meeting requisite criteria as per NIT |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
27 Jun 2023, 6:00 pmClosed
CWE AF PALAM
HQ CWE(AF) PALAM DELHI CANTT-110010
PROVN OF FIRE ALARM SYSTEM AT VARIOUS WINGS/SECTIONS OF AFCAO AT CAMERO COMPLEX UNDER GE (AF) SUBROTO PARK, DELHI CANTT-10
2023_MES_596669_1
CWE/PM/SP-09/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SUBROTO PARK
As per tender documents
10 documents required · 10 mandatory
₹1,000
GE AF SUBROTO PARK
₹1.9 L
25 Aug 2023
19 May 2023
30 Jun 2023
19 May 2023
27 Jun 2023
13 Jun 2023
Amount
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595 mmx 4mm thick any texture (Lake and Hill, oceanic cascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make at any height including dismantling complete all as specified and as directed.
M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square (size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls including PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling and dismantling complete all as specified and directed.
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc. including finished even and smooth without using extra cement including taking down cement plaster etc. on brick wall or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. and disposed off unserviceable materials to out side MOD land complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer including 3mm thick wall care putty on walls complete all as specified and directed.
M&L for preparation of old surface and applying two coat of oil bound distemper white or tinted on wall including repairing pot holes/cracks and 3mm thick wall care putty complete all as specified and directed.
Supply,Installation,Testing & Commissioning of UL/EN Listed Intelligent Addressable optical smoke detector having twin LED’s for 360 degree viewing angle & hard Addressable having rotary decade address which is from 01-99. LED on the detector shall blink each time the sensor is scanned by the FACP. If the FACP determines the sensor is in alarm, the FACP will command the sensor LED to remain on to indicate the same. Each Sensor will be capable of being tested for alarm via command from the FACP. Each sensor shall respond to FACPs can with the Information about its type for identification ,complete all as specified and directed.
Supply, Installation, Testing & Commissioning of UL/EN Listed Fault Isolator Module. This unit shall be placed on the loop preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring. All the other detectors shall remain functional because of the Class A wiring of the loop. The isolator shall not utilize an address and shall be built into the detector base wherever required complete all as specified and directed.
Supply, Installation, Testing & Commissioning of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting glass break type having Rotary Decade Switches for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standard sand Duly Approved by EN54 /LPCB /VDS /UL/ BSA complete all as specified and directed.
Supply,Installation,Testing & Commissioning of Response Indicator for above false ceiling detectors & detectors installed inside cabins.Response indicators with all accessories shall be as per technical specification complete all as specified and directed.
Supply,Installation,Testing & Commissioning of UL/EN Listed Intelligent addressable Output module having facility to activate AHU,Lifts etc.having option of RAIL or Surface Mounting withTri Color LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switches from 01-99 complete as required as per specification complete all as specified and as directed.
Supply,Installation,Testing & Commissioning of UL/EN Listed Intelligent addressable Input module for monitoring purpose having option of RAIL or Surface Mounting with Tri-Color LED status Indicator with Built in ShortCircuit Isolators having Visible Rotary Decade Address Switches from 01-99 dully approved to GEAGE1-082 conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed.
Supply,Installation,Testing & Commissioning of the Alarm Repeater /Annunciator Panel shall display fire /fault messages simultaneously with the FACP. It shall be capable of interfacing with the FACP on a single RS485Bus.The panel shall be capable of operating on 24V DC supply. The panel shall have a 2x40 character back light alphanumeric LCD display, which shall display date, time & description of alarm / trouble events that are displayed in the FACP with an inbuilt buzzer to indicate fault/fire alarm.It shall have control keys for Sound, Silence,Mute and to reset the FACP from the repeater station complete all as specified and as directed.
Supply,Installation,Testing & Commissioning of UL/EN Listed loop powered Sounder CUM Strobe complete all as required as per specification duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed . Note: No additional power supply and control module shall be required to trigger the sounder.
Supply,Installation,Testing & Commissioning of UL/EN Listed Analog addressable Fire Alarm system,having the capacity of 99 devices & 99 detectors per loop.The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 999 events. Further,the panel must be able to automatically switch ON/OFF respective control module whenever any alarm is triggered.The panel should have in built common Alarm,Fault and monitored sounder output. The panel shall have a alphanumeric LCD display and having minimum160 Characters in the display. A minimum of two on-board sounder circuits shall be provided.The sounder out puts shall be fully programmable, monitored and short-circuit protected.The panel shall have a built in power supply and battery charger, 24V SMF batteries sufficient for 24 hour in standby and 30 minutes in alarm condition and complete as required as per specification.The fire alarm panel should be network able upto 99 panel & repeater panel. A walk test option shall be provided for convenient testing of detectors and alarm initiating devices without continually having to reset the panel.The fire alarm panel shall be compatible for hardware / software integration of PA System.The panel shall provide a flexible way of performing complex cause-and-effect programming.The fire alarm control panel shall have the ability to automatically invoke different operating modes according to the time of day.The control panel shall be capable of expansion. Capacity of upto five analogue addressable detection loops,using five plug-in loop driver modules shall be available.The control panel shall support upto five analogue addressable loops with the capability to control 495 analogue sensors and 495 addressable modules giving the maximum capacity of 990 addresses in case of five loop panel. Each mode shall have adjustable startand finish times. 20number zonal fire indicators(LED’s) and 20 number zonal fault/test/disabled(LED’s) shall be provided.The fire alarm control panel shall have three user control levels. A dedicated RS232 port shall be available for both connections to a local printer and upload /download of configuration data via the manufacturer’s standard PC programming tool.
Ser item no 14.00 contd... The FACP shall have the provision to integrate with two way fire fighter control system.The FACP shall be able to supervise individual detectors for proper performance as well as to give pin point location of Fire or Fault alarm and initiate alarms as well as facility for cutting off of AHU’s and Electrical Power is also to be included.The panel shall be compatible with IBMS system with MODBUS protocol. EN54/UL/LPCB approved. NOTE:(a)The supplied fire alarm panel shall have the feature of soft integration with the existing fire alarm system & shall be able to network over RS485/Fiber/TCP/IP. (b) The FAS shall be able to control any output from any location. (c)The FAS shall be able to activate all output over network.(d)The supplied GUI software shall have the feature to monitor as well as control the entire system through software.
Supply and installation of Loop driver card complete all as specified and directed.
Supply and installation of RS 485 Communication module complete all as specified and directed.
Supply and installation of Modbus TCP/IP interface module, requires an RS485 card to be fitted in the control panel & MI-RJ-45 Cable complete all as specified and directed.
Supply,Installation,Testing & Commissioning of GUI software and regular licence to enable the display of key information from their analogue addressable fire detection and fire alarm system. Includeds Network Manager & Licence (Enable RMU devices:Smart Watch and Cube connection) Software should be able to connect 16 panel of any make. NOTE: (a)The supplied software shall be with all accessories including RS232/RS485 cards etc.(b) software should be integrated with existing FAS and all system shall be able to configured with SCADA
Supply,Installation,Testing & Commissioning of Intel core i5-1240 P processor, 8GB RAM, internal storage-512 GB, storage type ssd +1TB sata, windows 11 PRO, RS-232 port HDD, keyboard, mouse, wifi, bluetooth desktop with installation of GUI software complete all as specified and directed.
Supply,Installation,Testing & Commissioning of Smart signage 32'' FHD (1920x1080) – full hd display, 400 nit-brightness, 16.7 m colour-24 bits / pixel, 1.07 B (dithered 10 bit), RGB display port (1), video HDMI 2.0 (1) HDCP, HDCP 2.2, audio stereo min jack, HDMI USB 2.0 x 2, output RGB, HDMI 2.0, Built in speaker (10W + 10W), certification (safety 60950-1, EMC class-B, environment N/A, security 802.1x (WPA2 enterprise), EAP-TLS, EAP-TTLS, EAP-PEAP complete all as specified and directed (Make: Sony/LG/Samsung)
Supply,Installation,Testing & Commissioning of Single mode-unitube armoured 6 core outdoor fibre cable-HDPE. (A) Max tension-2000N (B) Crush resistance-4000N/ 10 cm (C) minimum bending radius – temporary -90mm, permanent – 180mm (D) max operating installation temperature -minus 30 degree celsius to plus 70 degree celsius complete all as specified and directed.
Supply,Installation,Testing & Commissioning of RS-232/422/485 to 100 BaseFX, fiber (single-mode or multi-mode),2KV(ICF-1150) Multi mode :2Km Single Mode:10Km C1D2,ATEX,IECEx complete all as specified and directed.
Supplying, drawing, connecting, testing & commissioning of 2 core, 1.5 sq. mm. stranded copper conductor, PVC insulated PVC sheathed,aluminium mylar tape shielded FRLS wire in draw through existing conduit complete all as specified and directed.
Supply and laying of 25mm Dia PVC conduits fixing on wall/roof/ceiling etc including concealed in wall and securing with proper saddle and making good disturbed surface and well finishing (For Fire Detection)with all accessories complete all as specified and directed.
M & L for point wiring with 1.5 sqmm (Nominal Area)PVC insulated un sheathed multi stranded copper conductor,FRLS 1100 Volts grade, with non metalic rigid PVC medium grade duty conduit/casing capping on wall/roof for surfacing wiring but not less than 20mm dia with accessories such as junction boxes, bends, tees etc. of suitable size including sunk cast iron or pressed steel terminal box for mounting switches, sockets fan regulators etc with 3 mm thick plastic laminated sheet top cover including continuous earth wire PVC insulated 1.50 Sq mm multi stranded copper conductor, FRLS 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed for the following :-
(a) One three pin switch socket 5 Amps plug point on independent board
Supply and fix of Switch Piano, Flush Button, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S&F of socket outlet 2 in 1, 3 pin 5 Amps flush type suitable for 240V AC complete all as specified and directed.
M & L for sheet metal enclosure with double door category of protection type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCB SPN 240 Volts, concealed in wall such that front cover shall be seen flush with the wall surface complete all as specified and directed for the following:- Make : Havells/L&T/Legrand
S&F MCB single pole and neutral 32 amps working on 240 volts 50 Hz AC supply,10 KA 'C' series including taking out old one complete all as specified and directed.. Make : Havells/L&T/C&S/Legrand
S&F MCB single pole 6 to 32 Amps working on 240 volts 50 Hz AC supply,10 KA 'C' series complete all as specified and directed.. Make : Havells/L&T/C&S/Legrand
S& F of sub main wiring with two single core PVC insulated unsheathed cable 1100 Volts FRLS grade with multi strand copper conductor and drawn through and including PVC conduit along with continuous earthing wire but in green colour complete on surface/concealed and connected to common earth dolly of the following size:- Note : Three run of PVC cable and one run of PVC conduit shall be measured as one unit length.
(a) 4 Sqmm ( 2 single run of 4 Sqmm and one run of 4 Sqmm as earth wire)
Satish Kumar Gupta
Malkit Singh and Bros
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .